Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.328
Filtrar
Más filtros











Intervalo de año de publicación
1.
F1000Res ; 13: 274, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38725640

RESUMEN

Background: The most recent advances in Computed Tomography (CT) image reconstruction technology are Deep learning image reconstruction (DLIR) algorithms. Due to drawbacks in Iterative reconstruction (IR) techniques such as negative image texture and nonlinear spatial resolutions, DLIRs are gradually replacing them. However, the potential use of DLIR in Head and Chest CT has to be examined further. Hence, the purpose of the study is to review the influence of DLIR on Radiation dose (RD), Image noise (IN), and outcomes of the studies compared with IR and FBP in Head and Chest CT examinations. Methods: We performed a detailed search in PubMed, Scopus, Web of Science, Cochrane Library, and Embase to find the articles reported using DLIR for Head and Chest CT examinations between 2017 to 2023. Data were retrieved from the short-listed studies using Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. Results: Out of 196 articles searched, 15 articles were included. A total of 1292 sample size was included. 14 articles were rated as high and 1 article as moderate quality. All studies compared DLIR to IR techniques. 5 studies compared DLIR with IR and FBP. The review showed that DLIR improved IQ, and reduced RD and IN for CT Head and Chest examinations. Conclusions: DLIR algorithm have demonstrated a noted enhancement in IQ with reduced IN for CT Head and Chest examinations at lower dose compared with IR and FBP. DLIR showed potential for enhancing patient care by reducing radiation risks and increasing diagnostic accuracy.


Asunto(s)
Algoritmos , Aprendizaje Profundo , Cabeza , Dosis de Radiación , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Cabeza/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Tórax/diagnóstico por imagen , Radiografía Torácica/métodos , Relación Señal-Ruido
2.
Med Phys ; 51(6): 4324-4339, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38710222

RESUMEN

BACKGROUND: Preclinical low-count positron emission tomography (LC-PET) imaging offers numerous advantages such as facilitating imaging logistics, enabling longitudinal studies of long- and short-lived isotopes as well as increasing scanner throughput. However, LC-PET is characterized by reduced photon-count levels resulting in low signal-to-noise ratio (SNR), segmentation difficulties, and quantification uncertainties. PURPOSE: We developed and evaluated a novel deep-learning (DL) architecture-Attention based Residual-Dilated Net (ARD-Net)-to generate standard-count PET (SC-PET) images from LC-PET images. The performance of the ARD-Net framework was evaluated for numerous low count realizations using fidelity-based qualitative metrics, task-based segmentation, and quantitative metrics. METHOD: Patient Derived tumor Xenograft (PDX) with tumors implanted in the mammary fat-pad were subjected to preclinical [18F]-Fluorodeoxyglucose (FDG)-PET/CT imaging. SC-PET images were derived from a 10 min static FDG-PET acquisition, 50 min post administration of FDG, and were resampled to generate four distinct LC-PET realizations corresponding to 10%, 5%, 1.6%, and 0.8% of SC-PET count-level. ARD-Net was trained and optimized using 48 preclinical FDG-PET datasets, while 16 datasets were utilized to assess performance. Further, the performance of ARD-Net was benchmarked against two leading DL-based methods (Residual UNet, RU-Net; and Dilated Network, D-Net) and non-DL methods (Non-Local Means, NLM; and Block Matching 3D Filtering, BM3D). The performance of the framework was evaluated using traditional fidelity-based image quality metrics such as Structural Similarity Index Metric (SSIM) and Normalized Root Mean Square Error (NRMSE), as well as human observer-based tumor segmentation performance (Dice Score and volume bias) and quantitative analysis of Standardized Uptake Value (SUV) measurements. Additionally, radiomics-derived features were utilized as a measure of quality assurance (QA) in comparison to true SC-PET. Finally, a performance ensemble score (EPS) was developed by integrating fidelity-based and task-based metrics. Concordance Correlation Coefficient (CCC) was utilized to determine concordance between measures. The non-parametric Friedman Test with Bonferroni correction was used to compare the performance of ARD-Net against benchmarked methods with significance at adjusted p-value ≤0.01. RESULTS: ARD-Net-generated SC-PET images exhibited significantly better (p ≤ 0.01 post Bonferroni correction) overall image fidelity scores in terms of SSIM and NRMSE at majority of photon-count levels compared to benchmarked DL and non-DL methods. In terms of task-based quantitative accuracy evaluated by SUVMean and SUVPeak, ARD-Net exhibited less than 5% median absolute bias for SUVMean compared to true SC-PET and lower degree of variability compared to benchmarked DL and non-DL based methods in generating SC-PET. Additionally, ARD-Net-generated SC-PET images displayed higher degree of concordance to SC-PET images in terms of radiomics features compared to non-DL and other DL approaches. Finally, the ensemble score suggested that ARD-Net exhibited significantly superior performance compared to benchmarked algorithms (p ≤ 0.01 post Bonferroni correction). CONCLUSION: ARD-Net provides a robust framework to generate SC-PET from LC-PET images. ARD-Net generated SC-PET images exhibited superior performance compared other DL and non-DL approaches in terms of image-fidelity based metrics, task-based segmentation metrics, and minimal bias in terms of task-based quantification performance for preclinical PET imaging.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Tomografía de Emisión de Positrones , Procesamiento de Imagen Asistido por Computador/métodos , Humanos , Animales , Ratones , Relación Señal-Ruido , Fluorodesoxiglucosa F18
3.
Biomed Phys Eng Express ; 10(4)2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38768575

RESUMEN

Background. Small field dosimetry presents unique challenges with source occlusion, lateral charged particle equilibrium and detector size. As detector volume decreases, signal strength declines while noise increases, deteriorating the signal-to-noise ratio (SNR). This issue may be compounded by triaxial cables connecting detectors to electrometers. However, effects of cables, critical for precision dosimetry, are often overlooked. There is a need to evaluate triaxial cable and detector impacts on SNR in small fields. The purpose of this study is to evaluate the influence of triaxial cables and microdetectors on signal-to-noise ratios in small-field dosimetry. This study also aims to establish the importance of cable quality assurance for measurement accuracy.Methods. Six 9.1 m length triaxial cables from different manufacturers were tested with six microdetectors (microDiamond, PinPoint, EDGE, Plastic scintillator, microSilicon, SRS-Diode). A 6 MV photon beam (TrueBeam) was used, with a water phantom at 5 cm depth with 0.5 × 0.5 cm2to 10 × 10 cm2fields at 600 MU min-1. Readings were acquired using cable-detector permutations with a dedicated electrometer (except the scintillator which has its own). Cables had differing connector types, conductor materials, insulation, and diameters. Detectors had various sensitive volumes, materials, typical signals, and bias voltages.Results. Normalized field output correction factors (FOFs) relative differences of 13.4% and 4.6% between the highest and lowest values across triaxial cables for 0.5 × 0.5 cm2and 1 × 1 cm2fields, respectively. The maximum difference in FOF between any cable-detector combinations was 0.2% for the smallest field size. No consistent FOF trend was observed across all detectors when increasing cable diameter. Additionally, the non-normalized FOF differences of 0.9% and 0.3% were observed between cables for 0.5 × 0.5 cm2and 1 × 1 cm2fields, respectively.Conclusions. Regular triaxial cable quality assurance is critical for precision small field dosimetry. A national protocol is needed to standardize cable evaluations/calibrations, particularly for small signals (

Asunto(s)
Diseño de Equipo , Fantasmas de Imagen , Radiometría , Relación Señal-Ruido , Radiometría/instrumentación , Radiometría/métodos , Fotones , Humanos
4.
Sci Transl Med ; 16(749): eadj3143, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38809965

RESUMEN

Visualization of human brain activity is crucial for understanding normal and aberrant brain function. Currently available neural activity recording methods are highly invasive, have low sensitivity, and cannot be conducted outside of an operating room. Functional ultrasound imaging (fUSI) is an emerging technique that offers sensitive, large-scale, high-resolution neural imaging; however, fUSI cannot be performed through the adult human skull. Here, we used a polymeric skull replacement material to create an acoustic window compatible with fUSI to monitor adult human brain activity in a single individual. Using an in vitro cerebrovascular phantom to mimic brain vasculature and an in vivo rodent cranial defect model, first, we evaluated the fUSI signal intensity and signal-to-noise ratio through polymethyl methacrylate (PMMA) cranial implants of different thicknesses or a titanium mesh implant. We found that rat brain neural activity could be recorded with high sensitivity through a PMMA implant using a dedicated fUSI pulse sequence. We then designed a custom ultrasound-transparent cranial window implant for an adult patient undergoing reconstructive skull surgery after traumatic brain injury. We showed that fUSI could record brain activity in an awake human outside of the operating room. In a video game "connect the dots" task, we demonstrated mapping and decoding of task-modulated cortical activity in this individual. In a guitar-strumming task, we mapped additional task-specific cortical responses. Our proof-of-principle study shows that fUSI can be used as a high-resolution (200 µm) functional imaging modality for measuring adult human brain activity through an acoustically transparent cranial window.


Asunto(s)
Encéfalo , Cráneo , Humanos , Encéfalo/diagnóstico por imagen , Animales , Cráneo/diagnóstico por imagen , Ultrasonografía/métodos , Ratas , Acústica , Fantasmas de Imagen , Polimetil Metacrilato/química , Relación Señal-Ruido , Masculino
5.
Nature ; 629(8014): 1062-1068, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38720082

RESUMEN

Most chemistry and biology occurs in solution, in which conformational dynamics and complexation underlie behaviour and function. Single-molecule techniques1 are uniquely suited to resolving molecular diversity and new label-free approaches are reshaping the power of single-molecule measurements. A label-free single-molecule method2-16 capable of revealing details of molecular conformation in solution17,18 would allow a new microscopic perspective of unprecedented detail. Here we use the enhanced light-molecule interactions in high-finesse fibre-based Fabry-Pérot microcavities19-21 to detect individual biomolecules as small as 1.2 kDa, a ten-amino-acid peptide, with signal-to-noise ratios (SNRs) >100, even as the molecules are unlabelled and freely diffusing in solution. Our method delivers 2D intensity and temporal profiles, enabling the distinction of subpopulations in mixed samples. Notably, we observe a linear relationship between passage time and molecular radius, unlocking the potential to gather crucial information about diffusion and solution-phase conformation. Furthermore, mixtures of biomolecule isomers of the same molecular weight and composition but different conformation can also be resolved. Detection is based on the creation of a new molecular velocity filter window and a dynamic thermal priming mechanism that make use of the interplay between optical and thermal dynamics22,23 and Pound-Drever-Hall (PDH) cavity locking24 to reveal molecular motion even while suppressing environmental noise. New in vitro ways of revealing molecular conformation, diversity and dynamics can find broad potential for applications in the life and chemical sciences.


Asunto(s)
Péptidos , Imagen Individual de Molécula , Difusión , Isomerismo , Luz , Péptidos/análisis , Péptidos/química , Péptidos/efectos de la radiación , Relación Señal-Ruido , Imagen Individual de Molécula/métodos , Soluciones , Conformación Proteica , Peso Molecular , Movimiento (Física)
6.
Nature ; 629(8013): 810-818, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38778234

RESUMEN

Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.


Asunto(s)
Velocidad del Flujo Sanguíneo , Encéfalo , Circulación Cerebrovascular , Ultrasonografía , Humanos , Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Circulación Cerebrovascular/fisiología , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Errores Médicos , Relación Señal-Ruido , Piel , Cráneo , Somnolencia/fisiología , Ultrasonografía/instrumentación , Ultrasonografía/métodos , Adulto
7.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38732804

RESUMEN

In general, it is difficult to visualize internal ocular structure and detect a lesion such as a cataract or glaucoma using the current ultrasound brightness-mode (B-mode) imaging. This is because the internal structure of the eye is rich in moisture, resulting in a lack of contrast between tissues in the B-mode image, and the penetration depth is low due to the attenuation of the ultrasound wave. In this study, the entire internal ocular structure of a bovine eye was visualized in an ex vivo environment using the compound acoustic radiation force impulse (CARFI) imaging scheme based on the phase-inverted ultrasound transducer (PIUT). In the proposed method, the aperture of the PIUT is divided into four sections, and the PIUT is driven by the out-of-phase input signal capable of generating split-focusing at the same time. Subsequently, the compound imaging technique was employed to increase signal-to-noise ratio (SNR) and to reduce displacement error. The experimental results demonstrated that the proposed technique could provide an acoustic radiation force impulse (ARFI) image of the bovine eye with a broader depth-of-field (DOF) and about 80% increased SNR compared to the conventional ARFI image obtained using the in-phase input signal. Therefore, the proposed technique can be one of the useful techniques capable of providing the image of the entire ocular structure to diagnose various eye diseases.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Ojo , Relación Señal-Ruido , Transductores , Animales , Bovinos , Ojo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía/métodos
8.
Biomed Phys Eng Express ; 10(4)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38781941

RESUMEN

Noise activity is known to affect neural networks, enhance the system response to weak external signals, and lead to stochastic resonance phenomenon that can effectively amplify signals in nonlinear systems. In most treatments, channel noise has been modeled based on multi-state Markov descriptions or the use stochastic differential equation models. Here we probe a computationally simple approach based on a minor modification of the traditional Hodgkin-Huxley approach to embed noise in neural response. Results obtained from numerous simulations with different excitation frequencies and noise amplitudes for the action potential firing show very good agreement with output obtained from well-established models. Furthermore, results from the Mann-Whitney U Test reveal a statistically insignificant difference. The distribution of the time interval between successive potential spikes obtained from this simple approach compared very well with the results of complicated Fox and Lu type methods at much reduced computational cost. This present method could also possibly be applied to the analysis of spatial variations and/or differences in characteristics of random incident electromagnetic signals.


Asunto(s)
Potenciales de Acción , Simulación por Computador , Modelos Neurológicos , Neuronas , Procesos Estocásticos , Potenciales de Acción/fisiología , Neuronas/fisiología , Humanos , Algoritmos , Cadenas de Markov , Campos Electromagnéticos , Modelos Estadísticos , Relación Señal-Ruido , Animales , Red Nerviosa/fisiología
9.
Med Phys ; 51(5): 3322-3333, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38597897

RESUMEN

BACKGROUND: The development of a new imaging modality, such as 4D dynamic contrast-enhanced dedicated breast CT (4D DCE-bCT), requires optimization of the acquisition technique, particularly within the 2D contrast-enhanced imaging modality. Given the extensive parameter space, cascade-systems analysis is commonly used for such optimization. PURPOSE: To implement and validate a parallel-cascaded model for bCT, focusing on optimizing and characterizing system performance in the projection domain to enhance the quality of input data for image reconstruction. METHODS: A parallel-cascaded system model of a state-of-the-art bCT system was developed and model predictions of the presampled modulation transfer function (MTF) and the normalized noise power spectrum (NNPS) were compared with empirical data collected in the projection domain. Validation was performed using the default settings of 49 kV with 1.5 mm aluminum filter and at 65 kV and 0.257 mm copper filter. A 10 mm aluminum plate was added to replicate the breast attenuation. Air kerma at the isocenter was measured at different tube current levels. Discrepancies between the measured projection domain metrics and model-predicted values were quantified using percentage error and coefficient of variation (CoV) for MTF and NNPS, respectively. The optimal filtration was for a 5 mm iodine disk detection task at 49, 55, 60, and 65 kV. The detectability index was calculated for the default aluminum filtration and for copper thicknesses ranging from 0.05 to 0.4 mm. RESULTS: At 49 kV, MTF errors were +5.1% and -5.1% at 1 and 2 cycles/mm, respectively; NNPS CoV was 5.3% (min = 3.7%; max = 8.5%). At 65 kV, MTF errors were -0.8% and -3.2%; NNPS CoV was 13.1% (min = 11.4%; max = 16.9%). Air kerma output was linear, with 11.67 µGy/mA (R2 = 0.993) and 19.14 µGy/mA (R2 = 0.996) at 49 and 65 kV, respectively. For iodine detection, a 0.25 mm-thick copper filter at 65 kV was found optimal, outperforming the default technique by 90%. CONCLUSION: The model accurately predicts bCT system performance, specifically in the projection domain, under varied imaging conditions, potentially contributing to the enhancement of 2D contrast-enhanced imaging in 4D DCE-bCT.


Asunto(s)
Mama , Medios de Contraste , Medios de Contraste/química , Mama/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Fantasmas de Imagen , Humanos , Mamografía/métodos , Mamografía/instrumentación , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido
10.
Acta Radiol ; 65(6): 654-662, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38623647

RESUMEN

BACKGROUND: Post-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time. PURPOSE: To evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients. MATERIAL AND METHODS: For evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratiolesion/parenchyma, and number of enhancing lesions for standard and accelerated T1-SPACE without ID. RESULTS: Although there was a significant difference in the overall image quality and mean contrast-to-noise ratiolesion/parenchyma between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size. CONCLUSION: Although accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.


Asunto(s)
Artefactos , Neoplasias Encefálicas , Medios de Contraste , Estudios de Factibilidad , Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Neoplasias Encefálicas/diagnóstico por imagen , Femenino , Estudios Retrospectivos , Masculino , Persona de Mediana Edad , Anciano , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Relación Señal-Ruido , Anciano de 80 o más Años , Aumento de la Imagen/métodos
11.
Artículo en Chino | MEDLINE | ID: mdl-38561257

RESUMEN

Objective: This study investigates the effect of signal-to-noise ratio (SNR), frequency, and bandwidth on horizontal sound localization accuracy in normal-hearing young adults. Methods: From August 2022 to December 2022, a total of 20 normal-hearing young adults, including 7 males and 13 females, with an age range of 20 to 35 years and a mean age of 25.4 years, were selected to participate in horizontal azimuth recognition tests under both quiet and noisy conditions. Six narrowband filtered noise stimuli were used with central frequencies (CF) of 250, 2 000, and 4 000 Hz and bandwidths of 1/6 and 1 octave. Continuous broadband white noise was used as the background masker, and the signal-to-noise ratio (SNR) was 0, -3, and -12 dB. The root-mean-square error (RMS error) was used to measure sound localization accuracy, with smaller values indicating higher accuracy. Friedman test was used to compare the effects of SNR and CF on sound localization accuracy, and Wilcoxon signed-rank test was used to compare the impact of the two bandwidths on sound localization accuracy in noise. Results: In a quiet environment, the RMS error in horizontal azimuth in normal-hearing young adults ranged from 4.3 to 8.1 degrees. Sound localization accuracy decreased with decreasing SNR: at 0 dB SNR (range: 5.3-12.9 degrees), the difference from the quiet condition was not significant (P>0.05); however, at -3 dB (range: 7.3-16.8 degrees) and -12 dB SNR (range: 9.4-41.2 degrees), sound localization accuracy significantly decreased compared to the quiet condition (all P<0.01). Under noisy conditions, there were differences in sound localization accuracy among stimuli with different frequencies and bandwidths, with higher frequencies performing the worst, followed by middle frequencies, and lower frequencies performing the best, with significant differences (all P<0.01). Sound localization accuracy for 1/6 octave stimuli was more susceptible to noise interference than 1 octave stimuli (all P<0.01). Conclusions: The ability of normal-hearing young adults to localize sound in the horizontal plane in the presence of noise is influenced by SNR, CF, and bandwidth. Noise with SNRs of ≥-3 dB can lead to decreased accuracy in narrowband sound localization. Higher CF signals and narrower bandwidths are more susceptible to noise interference.


Asunto(s)
Localización de Sonidos , Percepción del Habla , Masculino , Femenino , Humanos , Adulto Joven , Adulto , Ruido , Relación Señal-Ruido , Audición
12.
Biomed Phys Eng Express ; 10(3)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38579691

RESUMEN

Background.Modern radiation therapy technologies aim to enhance radiation dose precision to the tumor and utilize hypofractionated treatment regimens. Verifying the dose distributions associated with these advanced radiation therapy treatments remains an active research area due to the complexity of delivery systems and the lack of suitable three-dimensional dosimetry tools. Gel dosimeters are a potential tool for measuring these complex dose distributions. A prototype tabletop solid-tank fan-beam optical CT scanner for readout of gel dosimeters was recently developed. This scanner does not have a straight raypath from source to detector, thus images cannot be reconstructed using filtered backprojection (FBP) and iterative techniques are required.Purpose.To compare a subset of the top performing algorithms in terms of image quality and quantitatively determine the optimal algorithm while accounting for refraction within the optical CT system. The following algorithms were compared: Landweber, superiorized Landweber with the fast gradient projection perturbation routine (S-LAND-FGP), the fast iterative shrinkage/thresholding algorithm with total variation penalty term (FISTA-TV), a monotone version of FISTA-TV (MFISTA-TV), superiorized conjugate gradient with the nonascending perturbation routine (S-CG-NA), superiorized conjugate gradient with the fast gradient projection perturbation routine (S-CG-FGP), superiorized conjugate gradient with with two iterations of CG performed on the current iterate and the nonascending perturbation routine (S-CG-2-NA).Methods.A ray tracing simulator was developed to track the path of light rays as they traverse the different mediums of the optical CT scanner. Two clinical phantoms and several synthetic phantoms were produced and used to evaluate the reconstruction techniques under known conditions. Reconstructed images were analyzed in terms of spatial resolution, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), signal non-uniformity (SNU), mean relative difference (MRD) and reconstruction time. We developed an image quality based method to find the optimal stopping iteration window for each algorithm. Imaging data from the prototype optical CT scanner was reconstructed and analysed to determine the optimal algorithm for this application.Results.The optimal algorithms found through the quantitative scoring metric were FISTA-TV and S-CG-2-NA. MFISTA-TV was found to behave almost identically to FISTA-TV however MFISTA-TV was unable to resolve some of the synthetic phantoms. S-CG-NA showed extreme fluctuations in the SNR and CNR values. S-CG-FGP had large fluctuations in the SNR and CNR values and the algorithm has less noise reduction than FISTA-TV and worse spatial resolution than S-CG-2-NA. S-LAND-FGP had many of the same characteristics as FISTA-TV; high noise reduction and stability from over iterating. However, S-LAND-FGP has worse SNR, CNR and SNU values as well as longer reconstruction time. S-CG-2-NA has superior spatial resolution to all algorithms while still maintaining good noise reduction and is uniquely stable from over iterating.Conclusions.Both optimal algorithms (FISTA-TV and S-CG-2-NA) are stable from over iterating and have excellent edge detection with ESF MTF 50% values of 1.266 mm-1and 0.992 mm-1. FISTA-TV had the greatest noise reduction with SNR, CNR and SNU values of 424, 434 and 0.91 × 10-4, respectively. However, low spatial resolution makes FISTA-TV only viable for large field dosimetry. S-CG-2-NA has better spatial resolution than FISTA-TV with PSF and LSF MTF 50% values of 1.581 mm-1and 0.738 mm-1, but less noise reduction. S-CG-2-NA still maintains good SNR, CNR, and SNU values of 168, 158 and 1.13 × 10-4, respectively. Thus, S-CG-2-NA is a well rounded reconstruction algorithm that would be the preferable choice for small field dosimetry.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Radiometría/métodos , Relación Señal-Ruido , Algoritmos
13.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38588648

RESUMEN

Objective. Ultrasound-assisted orthopaedic navigation held promise due to its non-ionizing feature, portability, low cost, and real-time performance. To facilitate the applications, it was critical to have accurate and real-time bone surface segmentation. Nevertheless, the imaging artifacts and low signal-to-noise ratios in the tomographical B-mode ultrasound (B-US) images created substantial challenges in bone surface detection. In this study, we presented an end-to-end lightweight US bone segmentation network (UBS-Net) for bone surface detection.Approach. We presented an end-to-end lightweight UBS-Net for bone surface detection, using the U-Net structure as the base framework and a level set loss function for improved sensitivity to bone surface detectability. A dual attention (DA) mechanism was introduced at the end of the encoder, which considered both position and channel information to obtain the correlation between the position and channel dimensions of the feature map, where axial attention (AA) replaced the traditional self-attention (SA) mechanism in the position attention module for better computational efficiency. The position attention and channel attention (CA) were combined with a two-class fusion module for the DA map. The decoding module finally completed the bone surface detection.Main Results. As a result, a frame rate of 21 frames per second (fps) in detection were achieved. It outperformed the state-of-the-art method with higher segmentation accuracy (Dice similarity coefficient: 88.76% versus 87.22%) when applied the retrospective ultrasound (US) data from 11 volunteers.Significance. The proposed UBS-Net for bone surface detection in ultrasound achieved outstanding accuracy and real-time performance. The new method out-performed the state-of-the-art methods. It had potential in US-guided orthopaedic surgery applications.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Relación Señal-Ruido , Ultrasonografía , Humanos , Ultrasonografía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Huesos/diagnóstico por imagen , Redes Neurales de la Computación
14.
Phys Med Biol ; 69(10)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38604177

RESUMEN

Objective. To improve intravoxel incoherent motion imaging (IVIM) magnetic resonance Imaging quality using a new image denoising technique and model-independent parameterization of the signal versusb-value curve.Approach. IVIM images were acquired for 13 head-and-neck patients prior to radiotherapy. Post-radiotherapy scans were also acquired for five of these patients. Images were denoised prior to parameter fitting using neural blind deconvolution, a method of solving the ill-posed mathematical problem of blind deconvolution using neural networks. The signal decay curve was then quantified in terms of several area under the curve (AUC) parameters. Improvements in image quality were assessed using blind image quality metrics, total variation (TV), and the correlations between parameter changes in parotid glands with radiotherapy dose levels. The validity of blur kernel predictions was assessed by the testing the method's ability to recover artificial 'pseudokernels'. AUC parameters were compared with monoexponential, biexponential, and triexponential model parameters in terms of their correlations with dose, contrast-to-noise (CNR) around parotid glands, and relative importance via principal component analysis.Main results. Image denoising improved blind image quality metrics, smoothed the signal versusb-value curve, and strengthened correlations between IVIM parameters and dose levels. Image TV was reduced and parameter CNRs generally increased following denoising.AUCparameters were more correlated with dose and had higher relative importance than exponential model parameters.Significance. IVIM parameters have high variability in the literature and perfusion-related parameters are difficult to interpret. Describing the signal versusb-value curve with model-independent parameters like theAUCand preprocessing images with denoising techniques could potentially benefit IVIM image parameterization in terms of reproducibility and functional utility.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Relación Señal-Ruido , Humanos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia
15.
Clin Radiol ; 79(7): e908-e915, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38649313

RESUMEN

AIM: To compare the image quality of virtual noncontrast (VNC) and true noncontrast (TNC) CT images and to evaluate the clinical feasibility of VNC CT images for assessing osteochondral lesions of the talus (OLTs). MATERIALS AND METHODS: Forty-five OLT patients who underwent ankle CT arthrography (CTA) using dual-layer spectral detector CT were enrolled. Reconstruction of VNC and three-dimensional volume rendering images was performed. Afterward, image noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured. For the subjective evaluation, two board-certified musculoskeletal radiologists [R2-1] assessed spatial resolution, overall image quality, and lesion conspicuity. The accuracy rate for OLT grading was determined in 23 patients who underwent arthroscopic surgery. RESULTS: While VNC images showed significantly less noise than TNC images, TNC images showed better SNRs and CNRs (p<.01). In the subjective analysis, TNC images showed better overall image quality (p<.001). For the 3D volume rendering images, VNC images scored significantly higher for lesion conspicuity (p<.001). The accuracy rates of CTA and CTA with VNC images for OLT grading were 79.2% and 83.3%, respectively. Regarding confidence level, when CTA and VNC images were evaluated together, the confidence level was significantly higher than that when only CTA images were evaluated (p<.001). CONCLUSION: VNC imaging can provide better confidence level of OLT grading and evaluation of the integrity of the subchondral bone plate when combined with conventional CTA without additional radiation dose to the patient. In addition, VNC images-based 3D volume rendering reconstruction would be helpful for preoperative planning in OLT patients.


Asunto(s)
Artrografía , Estudios de Factibilidad , Astrágalo , Tomografía Computarizada por Rayos X , Humanos , Astrágalo/diagnóstico por imagen , Masculino , Femenino , Adulto , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Artrografía/métodos , Imagenología Tridimensional/métodos , Adulto Joven , Anciano , Adolescente , Relación Señal-Ruido , Estudios Retrospectivos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
16.
Phys Med Biol ; 69(11)2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38593815

RESUMEN

Objective. The primary objective of this study is to address the reconstruction time challenge in magnetic particle imaging (MPI) by introducing a novel approach named SNR-peak-based frequency selection (SPFS). The focus is on improving spatial resolution without compromising reconstruction speed, thereby enhancing the clinical potential of MPI for real-time imaging.Approach. To overcome the trade-off between reconstruction time and spatial resolution in MPI, the researchers propose SPFS as an innovative frequency selection method. Unlike conventional SNR-based selection, SPFS prioritizes frequencies with signal-to-noise ratio (SNR) peaks that capture crucial system matrix information. This adaptability to varying quantities of selected frequencies enhances versatility in the reconstruction process. The study compares the spatial resolution of MPI reconstruction using both SNR-based and SPFS frequency selection methods, utilizing simulated and real device data.Main results.The research findings demonstrate that the SPFS approach substantially improves image resolution in MPI, especially when dealing with a limited number of frequency components. By focusing on SNR peaks associated with critical system matrix information, SPFS mitigates the spatial resolution degradation observed in conventional SNR-based selection methods. The study validates the effectiveness of SPFS through the assessment of MPI reconstruction spatial resolution using both simulated and real device data, highlighting its potential to address a critical limitation in the field.Significance.The introduction of SPFS represents a significant breakthrough in MPI technology. The method not only accelerates reconstruction time but also enhances spatial resolution, thus expanding the clinical potential of MPI for various applications. The improved real-time imaging capabilities of MPI, facilitated by SPFS, hold promise for advancements in drug delivery, plaque assessment, tumor treatment, cerebral perfusion evaluation, immunotherapy guidance, andin vivocell tracking.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Relación Señal-Ruido , Procesamiento de Imagen Asistido por Computador/métodos , Factores de Tiempo , Fantasmas de Imagen , Imagen Molecular/métodos
17.
Anal Chim Acta ; 1303: 342530, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38609269

RESUMEN

MicroRNAs (miRNAs) are potential biomarkers for cancer diagnosis and prognosis, methods for detecting miRNAs with high sensitivity, selectivity, and stability are urgently needed. Various nucleic acid probes that have traditionally been for this purpose suffer several drawbacks, including inefficient signal-to-noise ratios and intensities, high cost, and time-consuming method establishment. Computing tools used for investigating the thermodynamics of DNA hybridization reactions can accurately predict the secondary structure of DNA and the interactions between DNA molecules. Herein, NUPACK was used to design a series of nucleic acid probes and develop a phosphorothioated-terminal hairpin formation and self-priming extension (PS-THSP) signal amplification strategy, which enabled the ultrasensitive detection of miR-200a in serum samples. The free and binding energies of the DNA detection probes calculated using NUPACK, as well as the biological experimental results, were considered synthetically to select the best sequence and experimental conditions. A unified dynamic programming framework, NUPACK analysis and the experimental data, were complementary and improved the designed model in all respects. Our study demonstrates the feasibility of using computer technology such as NUPACK to simplify the experimental process and provide intuitive results.


Asunto(s)
MicroARNs , Ácidos Nucleicos , Sondas de ADN/genética , MicroARNs/genética , Relación Señal-Ruido , Termodinámica
18.
Biomed Phys Eng Express ; 10(4)2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38608316

RESUMEN

Objectives: The aim of this study was to evaluate Cu-64 PET phantom image quality using Bayesian Penalized Likelihood (BPL) and Ordered Subset Expectation Maximum with point-spread function modeling (OSEM-PSF) reconstruction algorithms. In the BPL, the regularization parameterßwas varied to identify the optimum value for image quality. In the OSEM-PSF, the effect of acquisition time was evaluated to assess the feasibility of shortened scan duration.Methods: A NEMA IEC PET body phantom was filled with known activities of water soluble Cu-64. The phantom was imaged on a PET/CT scanner and was reconstructed using BPL and OSEM-PSF algorithms. For the BPL reconstruction, variousßvalues (150, 250, 350, 450, and 550) were evaluated. For the OSEM-PSF algorithm, reconstructions were performed using list-mode data intervals ranging from 7.5 to 240 s. Image quality was assessed by evaluating the signal to noise ratio (SNR), contrast to noise ratio (CNR), and background variability (BV).Results: The SNR and CNR were higher in images reconstructed with BPL compared to OSEM-PSF. Both the SNR and CNR increased with increasingß, peaking atß= 550. The CNR for allß, sphere sizes and tumor-to-background ratios (TBRs) satisfied the Rose criterion for image detectability (CNR > 5). BPL reconstructed images withß= 550 demonstrated the highest improvement in image quality. For OSEM-PSF reconstructed images with list-mode data duration ≥ 120 s, the noise level and CNR were not significantly different from the baseline 240 s list-mode data duration.Conclusions: BPL reconstruction improved Cu-64 PET phantom image quality by increasing SNR and CNR relative to OSEM-PSF reconstruction. Additionally, this study demonstrated scan time can be reduced from 240 to 120 s when using OSEM-PSF reconstruction while maintaining similar image quality. This study provides baseline data that may guide future studies aimed to improve clinical Cu-64 imaging.


Asunto(s)
Algoritmos , Teorema de Bayes , Radioisótopos de Cobre , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Relación Señal-Ruido , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Funciones de Verosimilitud , Humanos
19.
Comput Biol Med ; 174: 108448, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38626508

RESUMEN

BACKGROUND AND OBJECTIVE: Magnetic resonance imaging (MRI) has emerged as a noninvasive clinical tool for assessment of hepatic steatosis. Multi-spectral fat-water MRI models, incorporating single or dual transverse relaxation decay rate(s) (R2*) have been proposed for accurate fat fraction (FF) estimation. However, it is still unclear whether single- or dual-R2* model accurately mimics in vivo signal decay for precise FF estimation and the impact of signal-to-noise ratio (SNR) on each model performance. Hence, this study aims to construct virtual steatosis models and synthesize MRI signals with different SNRs to systematically evaluate the accuracy of single- and dual-R2* models for FF and R2* estimations at 1.5T and 3.0T. METHODS: Realistic hepatic steatosis models encompassing clinical FF range (0-60 %) were created using morphological features of fat droplets (FDs) extracted from human liver biopsy samples. MRI signals were synthesized using Monte Carlo simulations for noise-free (SNRideal) and varying SNR conditions (5-100). Fat-water phantoms were scanned with different SNRs to validate simulation results. Fat water toolbox was used to calculate R2* and FF for both single- and dual-R2* models. The model accuracies in R2* and FF estimates were analyzed using linear regression, bias plot and heatmap analysis. RESULTS: The virtual steatosis model closely mimicked in vivo fat morphology and Monte Carlo simulation produced realistic MRI signals. For SNRideal and moderate-high SNRs, water R2* (R2*W) by dual-R2* and common R2* (R2*com) by single-R2* model showed an excellent agreement with slope close to unity (0.95-1.01) and R2 > 0.98 at both 1.5T and 3.0T. In simulations, the R2*com-FF and R2*W-FF relationships exhibited slopes similar to in vivo calibrations, confirming the accuracy of our virtual models. For SNRideal, fat R2* (R2*F) was similar to R2*W and dual-R2* model showed slightly higher accuracy in FF estimation. However, in the presence of noise, dual-R2* produced higher FF bias with decreasing SNR, while leading to only marginal improvement for high SNRs and in regions dominated by fat and water. In contrast, single-R2* model was robust and produced accurate FF estimations in simulations and phantom scans with clinical SNRs. CONCLUSION: Our study demonstrates the feasibility of creating virtual steatosis models and generating MRI signals that mimic in vivo morphology and signal behavior. The single-R2* model consistently produced lower FF bias for clinical SNRs across entire FF range compared to dual-R2* model, hence signifying that single-R2* model is optimal for assessing hepatic steatosis.


Asunto(s)
Hígado Graso , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Hígado Graso/diagnóstico por imagen , Relación Señal-Ruido , Hígado/diagnóstico por imagen , Hígado/metabolismo , Simulación por Computador , Método de Montecarlo , Masculino , Modelos Biológicos , Tejido Adiposo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Femenino
20.
Eur Radiol Exp ; 8(1): 45, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38472565

RESUMEN

BACKGROUND: Phase-contrast magnetic resonance imaging (PC-MRI) quantifies blood flow and velocity noninvasively. Challenges arise in neurovascular disorders due to small vessels. We evaluated the impact of voxel size, number of signal averages (NSA), and velocity encoding (VENC) on PC-MRI measurement accuracy and precision in a small-lumen vessel phantom. METHODS: We constructed an in vitro model with a constant flow rate using a 2.2-mm inner diameter plastic tube. A reservoir with a weight scale and timer was used as standard reference. Gradient-echo T1 weighted PC-MRI sequence was performed on a 3-T scanner with varying voxel size (2.5, 5.0, 7.5 mm3), NSA (1, 2, 3), and VENC (200, 300, 400 cm/s). We repeated measurements nine times per setting, calculating mean flow rate, maximum velocity, and least detectable difference (LDD). RESULTS: PC-MRI flow measurements were higher than standard reference values (mean ranging from 7.3 to 9.5 mL/s compared with 6.6 mL/s). Decreased voxel size improved accuracy, reducing flow rate measurements from 9.5 to 7.3 mL/s. The LDD for flow rate and velocity varied between 1 and 5%. The LDD for flow rate decreased with increased voxel size and NSA (p = 0.033 and 0.042). The LDD for velocity decreased with increased voxel size (p < 10-16). No change was observed when VENC varied. CONCLUSIONS: PC-MRI overestimated flow. However, it has high precision in a small-vessel phantom with constant flow rate. Improved accuracy was obtained with increasing spatial resolution (smaller voxels). Improved precision was obtained with increasing signal-to-noise ratio (larger voxels and/or higher NSA). RELEVANCE STATEMENT: Phase-contrast MRI is clinically used in large vessels. To further investigate the possibility of using phase-contrast MRI for smaller intracranial vessels in neurovascular disorders, we need to understand how acquisition parameters affect phase-contrast MRI-measured flow rate and velocity in small vessels. KEY POINTS: • PC-MRI measures flow and velocity in a small lumen phantom with high precision but overestimates flow rate. • The precision of PC-MRI measurements matches the precision of standard reference for flow rate measurements. • Optimizing PC-MRI settings can enhance accuracy and precision in flow rate and velocity measurements.


Asunto(s)
Imagen por Resonancia Magnética , Velocidad del Flujo Sanguíneo/fisiología , Imagen por Resonancia Magnética/métodos , Relación Señal-Ruido , Fantasmas de Imagen , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA