Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Anal Bioanal Chem ; 416(12): 2969-2981, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38488952

RESUMEN

Oral endocrine therapies (OET) for breast cancer treatment need to be taken over a long period of time and are associated with considerable side effects. Therefore, adherence to OET is an important issue and of high clinical significance for breast cancer patients' caregivers. We hypothesized that a new bioanalytical strategy based on liquid chromatography and high-resolution mass spectrometry might be suitable for unbiased adherence monitoring (AM) of OET. Four different biomatrices (plasma, urine, finger prick blood by volumetric absorptive microsampling (VAMS), oral fluid (OF)) were evaluated regarding their suitability for AM of the OET abemaciclib, anastrozole, exemestane, letrozole, palbociclib, ribociclib, tamoxifen, and endoxifen. An analytical method was developed and validated according to international recommendations. The analytical procedures were successfully validated in all sample matrices for most analytes, even meeting requirements for therapeutic drug monitoring. Chromatographic separation of analytes was achieved in less than 10 min and limits of quantification ranged from 1 to 1000 ng/mL. The analysis of 25 matching patient samples showed that AM of OET is possible using all four matrices with the exception of, e.g., letrozole and exemestane in OF. We were able to show that unbiased bioanalytical AM of OET was possible using different biomatrices with distinct restrictions. Sample collection of VAMS was difficult in most cases due to circulatory restraints and peripheral neuropathy in fingers and OF sampling was hampered by dry mouth syndrome in some cases. Although parent compounds could be detected in most of the urine samples, metabolites should be included when analyzing urine or OF. Plasma is currently the most suitable matrix due to available reference concentrations.


Asunto(s)
Antineoplásicos Hormonales , Neoplasias de la Mama , Monitoreo de Drogas , Humanos , Femenino , Neoplasias de la Mama/tratamiento farmacológico , Antineoplásicos Hormonales/sangre , Antineoplásicos Hormonales/uso terapéutico , Antineoplásicos Hormonales/orina , Monitoreo de Drogas/métodos , Cromatografía Liquida/métodos , Administración Oral , Espectrometría de Masas/métodos , Letrozol/sangre , Cumplimiento de la Medicación , Límite de Detección , Tamoxifeno/uso terapéutico , Tamoxifeno/sangre , Tamoxifeno/análisis , Tamoxifeno/orina , Saliva/química , Androstadienos/orina , Androstadienos/análisis , Androstadienos/administración & dosificación , Androstadienos/uso terapéutico , Androstadienos/sangre , Anastrozol , Reproducibilidad de los Resultados
2.
Drug Des Devel Ther ; 15: 2417-2430, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34113081

RESUMEN

INTRODUCTION: In this research, we used a volumetric absorptive microsampling (VAMS) technique to collect blood samples from the patients. A rapid and simple sample preparation method and LC-MS.MS assay was then developed and validated for the simultaneous analysis of tamoxifen and its three active metabolites. METHODS: VAMS extraction was performed in methanol by sonication-assisted extraction method for 25 min after 2 hof VAMS drying. Separation was carried out using Acquity UPLC BEH C18 column (2.1 x 100 mm; 1.7 µm), with a flow rate of 0.2 mL/min, and the mobile phase gradient of formic acid 0.1% and formic acid 0.1% in acetonitrile for 5 min. The multiple reaction monitoring (MRM) values were set at m/z 358.31>58.27 for N-desmethyltamoxifen, m/z 372.33>72.28 for tamoxifen, m/z 388.22>72.28 for 4-hydroxytamoxifen, m/z 374.25>58.25 for endoxifen, and m/z 260.26>116.12 for propranolol. RESULTS AND DISCUSSION: The lower limit of quantification value (LLOQ) was 2.50 ng/mL for tamoxifen, 2.50 ng/mL for endoxifen, 1.50 ng/mL for 4-hydroxitamoxifen, and 2.00 ng/mL for N-desmethyltamoxifen. Accuracy (%bias) and precision (%CV) were within 20% for LLOQ and 15% for other concentrations. There were no interference responses >20% of the LLOQ and 5% of the internal standard. The level of ion suppression in all analytes was less than 7%. The preparation system developed in this study successfully extracted more than 90% of analytes from the matrix with precision below 15%. Carryover was shown to be below 6% in all analytes. Stability of analytes in VAMS was demonstrated for up to 30 days, under room temperature storage in a sealed plastic bag with desiccant. This method was successfully applied to analyze tamoxifen and the metabolites level in 30 ER+ breast cancer patients.


Asunto(s)
Antineoplásicos Hormonales/análisis , Neoplasias de la Mama/tratamiento farmacológico , Tamoxifeno/análisis , Antineoplásicos Hormonales/administración & dosificación , Antineoplásicos Hormonales/farmacocinética , Cromatografía Líquida de Alta Presión/métodos , Monitoreo de Drogas/métodos , Femenino , Humanos , Reproducibilidad de los Resultados , Tamoxifeno/administración & dosificación , Tamoxifeno/análogos & derivados , Tamoxifeno/farmacocinética , Espectrometría de Masas en Tándem/métodos , Factores de Tiempo
3.
Environ Sci Pollut Res Int ; 27(2): 1339-1347, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31832963

RESUMEN

Water contamination with pharmaceutical products is a well-studied problem. Numerous studies have demonstrated the presence of anticancer drugs in different water resources that failed to be eliminated by conventional wastewater treatment plants. The purpose of this report was to conduct a systematic review of anticancer drugs in the aquatic environment. The methodology adopted was carried out in compliance with the PRISMA guidelines. From the 75 studies that met the specific requirements for inclusion, data extracted showed that the most common anticancer drugs studied are cyclophosphamide, tamoxifen, ifosfamide and methotrexate with concentrations measured ranging between 0.01 and 86,200 ng/L. There was significant variation in the methodologies employed due to lack of available guidelines to address sampling techniques, seasonal variability and analytical strategy. The most routinely used technique for quantitative determination was found to be solid-phase extraction followed by LC-MS analysis. The lowest reported recovery percentage was 11%, and the highest limit of detection was 1700 ng/L. This indicated the inadequacy of some methods to analyse anticancer drugs and the failure to obtain reliable results. The significant heterogeneity within methodologies made it difficult to compare results and draw conclusions, nevertheless, this study aids in the extrapolation of proposed recommendations to guide future studies and reviews. Graphical abstract.


Asunto(s)
Antineoplásicos/análisis , Monitoreo del Ambiente/métodos , Preparaciones Farmacéuticas/análisis , Extracción en Fase Sólida/métodos , Aguas Residuales/química , Contaminantes Químicos del Agua/análisis , Cromatografía Liquida/métodos , Ciclofosfamida/análisis , Humanos , Ifosfamida/análisis , Metotrexato/análisis , Tamoxifeno/análisis
4.
Breast Cancer ; 26(5): 535-543, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30734152

RESUMEN

BACKGROUND: An association between CYP2D6 polymorphisms and tamoxifen (TAM) efficacy has not been confirmed, partly due to unreliable prediction of active metabolite exposure solely by CYP2D6 activity. The efficacy of TAM dose escalation appears limited in poor TAM metabolizers. Since the chlorine atom on the side chain of toremifene (TOR) prevents 4-hydroxylation by CYP2D6, its contribution to active conversion of TOR is minor. We examined the role of TOR and its dose escalation among poor TAM metabolizers. METHODS: The pharmacokinetics (PK) and pharmacogenomics (PGx) of TAM and TOR were studied. Correlation between PK and CYP2D6 inhibitor use, smoking status, and PGx were examined by regression analysis. For patients showing low endoxifen levels, an intra-patient dose escalation of TOR was conducted, and TOR was increased from 40 to 120 mg for ≥ 24 weeks with PK sampling. Total activity was calculated as the sum of the concentration of each active metabolite adjusted by their respective in vitro activities. RESULTS: Fifty and 11 of the 273 participating patients had endoxifen levels < 15 and < 7.5 ng/mL, respectively. The CYP2D6 genotype was the major determinant for TAM activity (p < 0.01). Smoking status (p = 0.07) and the CYP2C19 phenotype (p = 0.07), but not the CYP2D6 genotype (p = 0.61), showed marginally significant effects on TOR activity. TOR activity increased significantly with dose escalation, even among poor TAM metabolizers, and was maintained for ≥ 24 weeks. CONCLUSION: TOR might be a valid alternative to TAM in patients predicted to be poor TAM metabolizers.


Asunto(s)
Neoplasias de la Mama/metabolismo , Citocromo P-450 CYP2D6/genética , Citocromo P-450 CYP2D6/metabolismo , Genotipo , Moduladores Selectivos de los Receptores de Estrógeno/farmacocinética , Tamoxifeno/análogos & derivados , Toremifeno/farmacocinética , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/tratamiento farmacológico , Citocromo P-450 CYP2C19/genética , Inhibidores del Citocromo P-450 CYP2D6/uso terapéutico , Femenino , Sofocos/etiología , Humanos , Hidroxilación , Persona de Mediana Edad , Fenotipo , Polimorfismo Genético , Moduladores Selectivos de los Receptores de Estrógeno/administración & dosificación , Moduladores Selectivos de los Receptores de Estrógeno/efectos adversos , Moduladores Selectivos de los Receptores de Estrógeno/uso terapéutico , Fumar , Tamoxifeno/análisis , Toremifeno/administración & dosificación , Toremifeno/efectos adversos , Toremifeno/uso terapéutico
5.
Anal Chem ; 91(4): 2710-2718, 2019 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-30664349

RESUMEN

Monitoring drug uptake, its metabolism, and response on the single-cell level is invaluable for sustaining drug discovery efforts. In this study, we show the possibility of accessing the information about the aforementioned processes at the single-cell level by monitoring the anticancer drug tamoxifen using live single-cell mass spectrometry (LSC-MS) and Raman spectroscopy. First, we explored whether Raman spectroscopy could be used as a label-free and nondestructive screening technique to identify and predict the drug response at the single-cell level. Then, a subset of the screened cells was isolated and analyzed by LSC-MS to measure tamoxifen and its metabolite, 4-Hydroxytamoxifen (4-OHT) in a highly selective, sensitive, and semiquantitative manner. Our results show the Raman spectral signature changed in response to tamoxifen treatment which allowed us to identify and predict the drug response. Tamoxifen and 4-OHT abundances quantified by LSC-MS suggested some heterogeneity among single-cells. A similar phenomenon was observed in the ratio of metabolized to unmetabolized tamoxifen across single-cells. Moreover, a correlation was found between tamoxifen and its metabolite, suggesting that the drug was up taken and metabolized by the cell. Finally, we found some potential correlations between Raman spectral intensities and tamoxifen abundance, or its metabolism, suggesting a possible relationship between the two signals. This study demonstrates for the first time the potential of using Raman spectroscopy and LSC-MS to investigate pharmacokinetics at the single-cell level.


Asunto(s)
Antineoplásicos/análisis , Espectrometría de Masas/métodos , Análisis de la Célula Individual/métodos , Espectrometría Raman/métodos , Tamoxifeno/análisis , Antineoplásicos/metabolismo , Antineoplásicos/farmacocinética , Células Hep G2 , Humanos , Análisis Multivariante , Prueba de Estudio Conceptual , Reproducibilidad de los Resultados , Tamoxifeno/análogos & derivados , Tamoxifeno/metabolismo , Tamoxifeno/farmacocinética
6.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1106-1107: 26-34, 2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-30639947

RESUMEN

A liquid chromatography-mass spectrometry assay was developed and validated for simultaneous quantification of anti-hormonal compounds abiraterone, anastrozole, bicalutamide, Δ(4)-abiraterone (D4A), N-desmethyl enzalutamide, enzalutamide, Z-endoxifen, exemestane and letrozole for the purpose of therapeutic drug monitoring (TDM). Plasma samples were prepared with protein precipitation. Analyses were performed with a triple quadrupole mass spectrometer operating in the positive and negative ion-mode. The validated assay ranges from 2 to 200 ng/mL for abiraterone, 0.2-20 ng/mL for D4A, 10-200 ng/mL for anastrozole and letrozole, 1-20 ng/mL for Z-endoxifen, 1.88-37.5 ng/mL for exemestane and 1500-30,000 ng/mL for enzalutamide, N-desmethyl enzalutamide and bicalutamide. Due to low sensitivity for exemestane, the final extract of exemestane patient samples should be concentrated prior to injection and a larger sample volume should be prepared for exemestane patient samples and QC samples to obtain adequate sensitivity. Furthermore, we observed a batch-dependent stability for abiraterone in plasma at room temperature and therefore samples should be shipped on ice. This newly validated method has been successfully applied for routine TDM of anti-hormonal drugs in cancer patients.


Asunto(s)
Antineoplásicos Hormonales , Monitoreo de Drogas/métodos , Administración Oral , Anastrozol/administración & dosificación , Anastrozol/análisis , Androstadienos/administración & dosificación , Androstadienos/análisis , Androstenos/administración & dosificación , Androstenos/análisis , Anilidas/administración & dosificación , Anilidas/análisis , Antineoplásicos Hormonales/administración & dosificación , Antineoplásicos Hormonales/análisis , Benzamidas , Cromatografía Líquida de Alta Presión , Humanos , Nitrilos/administración & dosificación , Nitrilos/análisis , Feniltiohidantoína/administración & dosificación , Feniltiohidantoína/análogos & derivados , Feniltiohidantoína/análisis , Feniltiohidantoína/metabolismo , Tamoxifeno/administración & dosificación , Tamoxifeno/análogos & derivados , Tamoxifeno/análisis , Espectrometría de Masas en Tándem , Compuestos de Tosilo/administración & dosificación , Compuestos de Tosilo/análisis
7.
Anal Bioanal Chem ; 408(7): 1855-61, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26862049

RESUMEN

A signalling molecularly imprinted polymer was synthesised for easy detection of tamoxifen and its metabolites. 6-Vinylcoumarin-4-carboxylic acid (VCC) was synthesised from 4-bromophenol to give a fluorescent monomer, designed to switch off upon binding of tamoxifen. Clomiphene, a chlorinated analogue, was used as the template for the imprinting, and its ability to quench the coumarin fluorescence when used in a 1:1 ratio was demonstrated. Tamoxifen and 4-hydroxytamoxifen were also shown to quench coumarin fluorescence. Imprinted and non-imprinted polymers were synthesised using VCC, methacrylic acid as a backbone monomer and ethylene glycol dimethacrylate as cross-linker, and were ground and sieved to particle sizes ranging between 45 and 25 µm. Rebinding experiments demonstrate that the imprinted polymer shows very strong affinity for both clomiphene and tamoxifen, while the non-imprinted polymer shows negligible rebinding. The fluorescence of the imprinted polymer is quenched by clomiphene, tamoxifen and 4-hydroxytamoxifen. The switch off in fluorescence of the imprinted polymer under these conditions could also be detected under a UV lamp with the naked eye, making this matrix suitable for applications when coupled with a sample preparation system.


Asunto(s)
Cumarinas/química , Colorantes Fluorescentes/química , Impresión Molecular/métodos , Polímeros/química , Moduladores Selectivos de los Receptores de Estrógeno/análisis , Tamoxifeno/análisis , Compuestos de Vinilo/química , Cumarinas/síntesis química , Colorantes Fluorescentes/síntesis química , Espectrometría de Fluorescencia/métodos , Compuestos de Vinilo/síntesis química
8.
Electrophoresis ; 37(9): 1166-9, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26873060

RESUMEN

Micelle to solvent stacking was implemented for the recently established NACE-C(4) D method to determine tamoxifen and its metabolites in standard samples and human plasma of breast cancer patients. For stacking, the standard samples and extract after liquid-liquid extraction (LLE) were prepared in methanol and the resulting sample solution was pressure injected after a micellar plug of SDS. Factors that affected the stacking such as SDS concentration, micelle, and sample plug length were examined. The sensitivity enhancement factor (peak height from stacking/peak height from typical injection of sample in BGE) was 15-22. The method detection limits with LLE were in the range of 5-10 ng/mL, which was lower than the established method (where the LLE extract was also prepared in methanol) with reported method detection limits of 25-40 ng/mL. The intraday and interday repeatability were in the range of 1.0-3.4% and 3.8-6.5%, respectively.


Asunto(s)
Electroforesis Capilar/métodos , Micelas , Tamoxifeno/análisis , Humanos , Límite de Detección , Modelos Lineales , Reproducibilidad de los Resultados , Tamoxifeno/sangre
9.
Environ Res ; 144(Pt A): 43-59, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26555843

RESUMEN

Methotrexate (MTX) and tamoxifen (TMX) cancer therapeutic drugs have been detected within the aquatic environment. Nevertheless, MTX and TMX research is essentially bio-medically orientated, with few studies addressing the question of its toxicity in fresh water organisms, and none to its' effect in the marine environment. To the authors' knowledge, Environmental Risk Assessments (ERA) for pharmaceuticals has mainly been designed for freshwater and terrestrial environments (European Medicines Agency-EMEA guideline, 2006). Therefore, the purpose of this research was (1) to assess effect of MTX and TMX in marine organism using the EMEA guideline, (2) to develop an ERA methodology for marine environment, and (3) to evaluate the suitability of including a biomarker approach in Phase III. To reach these aims, a risk assessment of MTX and TMX was performed following EMEA guideline, including a 2-tier approach during Phase III, applying lysosomal membrane stability (LMS) as a screening biomarker in tier-1 and a battery of biochemical biomarkers in tier-2. Results from Phase II indicated that MTX was not toxic for bacteria, microalgae and sea urchin at the concentrations tested, thus no further assessment was required, while TMX indicated a possible risk. Therefore, Phase III was performed for only TMX. Ruditapes philippinarum were exposed during 14 days to TMX (0.1, 1, 10, 50 µg L(-1)). At the end of the experiment, clams exposed to environmental concentration indicated significant changes in LMS compared to the control (p<0.01); thus a second tier was applied. A significant induction of biomarkers (activity of Ethoxyresorufin O-deethylase [EROD], glutathione S-transferase [GST], glutathione peroxidase [GPX], and lipid peroxidation [LPO] levels) was observed in digestive gland tissues of clams compared with control (p<0.01). Finally, this study indicated that MTX was not toxic at an environmental concentration, whilst TMX was potentially toxic for marine biota. This study has shown the necessity to create specific guidelines in order to evaluate effects of pharmaceuticals in marine environment which includes sensitive endpoints. The inadequacy of current EMEA guideline to predict chemotherapy agents toxicity in Phase II was displayed whilst the usefulness of other tests were demonstrated. The 2-tier approach, applied in Phase III, appears to be suitable for an ERA of cancer therapeutic drugs in the marine environment.


Asunto(s)
Antineoplásicos/toxicidad , Metotrexato/toxicidad , Medición de Riesgo/métodos , Tamoxifeno/toxicidad , Contaminantes Químicos del Agua/toxicidad , Acetilcolinesterasa/metabolismo , Animales , Antineoplásicos/análisis , Biomarcadores/metabolismo , Bivalvos/efectos de los fármacos , Bivalvos/genética , Bivalvos/metabolismo , Citocromo P-450 CYP1A1/metabolismo , Daño del ADN , Fertilización/efectos de los fármacos , Glutatión Peroxidasa/metabolismo , Glutatión Transferasa/metabolismo , Haptophyta/efectos de los fármacos , Haptophyta/crecimiento & desarrollo , Peroxidación de Lípido/efectos de los fármacos , Luminiscencia , Lisosomas/metabolismo , Metotrexato/análisis , Paracentrotus/efectos de los fármacos , Paracentrotus/fisiología , Proteobacteria/efectos de los fármacos , Proteobacteria/metabolismo , Agua de Mar , Tamoxifeno/análisis , Contaminantes Químicos del Agua/análisis
10.
Sci Rep ; 5: 16126, 2015 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-26530625

RESUMEN

Tamoxifen is used in clinical practice for breast cancer patients and to prevent osteoporosis. Red clover (Trifolium pratense) preparations are consumed worldwide as dietary supplements for relieving postmenopausal symptoms. In the present study we investigated the possible herb-drug interaction between red clover and tamoxifen in rats. 15 days pre-treatment with red clover did not alter the tamoxifen and its active metabolite 4-hydroxytamoxifen pharmacokinetics significantly (p > 0.05). Therefore the therapeutic efficacy of the tamoxifen may not be compromised by the co-administration with red clover. Tamoxifen metabolism is primarily mediated by CYP2D6, CYP3A4 with minor contribution from CYP2C9, CYP2E1 and CYP1A2 isoforms. Although, red clover pre-treatment significantly (p < 0.05) decreased the mRNA expression and activity of CYP3a2, no effect on CYP2d4 and increased expression and activity of CYP2c11 could be the plausible reasons for lack of effect on tamoxifen and its metabolite pharmacokinetics in rats. CYP1a1 and CYP2b2 mRNA expression and activity were also significantly reduced by red clover. To extend the clinical utility of the present study, effect of red clover extract on major CYPs using human liver microsomes and HepG2 cell lines were also determined. Similar finding were observed in the human liver preparations as in rats.


Asunto(s)
Extractos Vegetales/farmacología , Tamoxifeno/análogos & derivados , Tamoxifeno/farmacocinética , Trifolium/química , Animales , Área Bajo la Curva , Hidrocarburo de Aril Hidroxilasas/genética , Hidrocarburo de Aril Hidroxilasas/metabolismo , Citocromo P-450 CYP1A1/genética , Citocromo P-450 CYP1A1/metabolismo , Citocromo P-450 CYP2D6/genética , Citocromo P-450 CYP2D6/metabolismo , Citocromo P-450 CYP3A/genética , Citocromo P-450 CYP3A/metabolismo , Femenino , Semivida , Células Hep G2 , Humanos , Microsomas Hepáticos/metabolismo , Extractos Vegetales/análisis , Extractos Vegetales/química , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , ARN Mensajero/metabolismo , Curva ROC , Ratas , Ratas Sprague-Dawley , Esteroide Hidroxilasas/genética , Esteroide Hidroxilasas/metabolismo , Tamoxifeno/análisis , Trifolium/metabolismo
11.
Water Res ; 85: 199-207, 2015 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-26320721

RESUMEN

The selective estrogen receptor modulator tamoxifen is the most commonly used drug for the treatment and prevention of breast cancer. Tamoxifen is considered as a pro-drug since it is known to exert its pharmacological effect through its major active metabolites, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen, which are mainly excreted in the urine in the days following administration. In the present work, the reactivity of tamoxifen and its major active metabolites in free chlorine-containing water was investigated for the first time. Under the studied chlorination conditions, tamoxifen was fairly stable whereas its metabolites were quickly degraded. A total of thirteen chlorinated byproducts were tentatively identified by ultra-high performance liquid chromatography coupled to high-resolution hybrid quadrupole-Orbitrap tandem mass spectrometry. Time-course profiles of the identified byproducts were followed in real wastewater samples under conditions that simulate wastewater disinfection. A preliminary assessment of their acute aquatic toxicity at two trophic levels by means of quantitative structure-activity relationship models showed that the identified byproducts were up to 110-fold more toxic than the parent compounds.


Asunto(s)
Tamoxifeno/análogos & derivados , Tamoxifeno/toxicidad , Contaminantes Químicos del Agua/toxicidad , Purificación del Agua , Cromatografía Líquida de Alta Presión , Desinfección , Halogenación , Relación Estructura-Actividad Cuantitativa , Tamoxifeno/análisis , Tamoxifeno/química , Espectrometría de Masas en Tándem , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/química
12.
J Pharm Biomed Anal ; 114: 416-25, 2015 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-26119504

RESUMEN

The aim of this study was to validate an earlier developed high-performance highly sensitive ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for quantification of tamoxifen and its three main metabolites (N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen) in scalp hair. This non-invasive method might, by segmental analysis of hair, be useful in the determination of the concentration of drugs and its metabolites over time, which can be used to study a wide variety of clinical relevant questions. Hair samples (150-300 hair strands, cut as close to the scalp as possible from the posterior vertex region of the head) were collected from female patients taking tamoxifen 20mg daily (n=19). The analytes were extracted using a liquid-liquid extraction procedure with carbonate buffer at pH 8.8 and a mixture of n-hexane/isopropranol method, followed by UPLC-MS/MS chromatography, based on an earlier validated method. The calibration curves were linear in the range of 1.00-200 pmol for tamoxifen and N-desmethyl-tamoxifen, with lower limit of quantitation of 1.00 pmol and 0.100-20.0 pmol with lower limit of quantitation of 0.100 pmol for endoxifen and 4-hydroxy-tamoxifen. Assay performance was fair with a within-run and between-run variability less than 9.24 at the three quality control samples and less than 15.7 for the lower limit of quantitation. Importantly, a steep linear decline was observed from distal to proximal hair segments. Probably, this is due to UV exposure as we showed degradation of tamoxifen and its metabolites after exposure to UV-light. Furthermore, higher concentrations of tamoxifen were found in black hair samples compared to blond and brown hair samples. We conclude that measurement of the concentration of tamoxifen and its main metabolites in hair is possible, with the selective, sensitive, accurate and precise UPLC-MS/MS method. However, for tamoxifen, it seems not possible to determine exposure over time with segmental analysis of hair, probably largely due to the effect of UV irradiation. Further research should therefore focus on quantification of other anticancer drugs, in segmented scalp hair, that are less sensitive to UV irradiation.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cabello/efectos de los fármacos , Cuero Cabelludo/efectos de los fármacos , Tamoxifeno/análisis , Espectrometría de Masas en Tándem/métodos , Adulto , Anciano , Calibración , Femenino , Cabello/química , Humanos , Concentración de Iones de Hidrógeno , Luz , Límite de Detección , Persona de Mediana Edad , Control de Calidad , Reproducibilidad de los Resultados , Cuero Cabelludo/química , Tamoxifeno/análogos & derivados , Rayos Ultravioleta
13.
Analyst ; 140(12): 4068-75, 2015 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-25884046

RESUMEN

An electronic nanoswitch is described based on the conformational change of the DNA sequence in the presence of stabilizing ligands. The new electrochemical biosensor was prepared by modifying a screen-printed graphite electrode (SPE) with functionalized SiO2 nanoparticles [(SiO2-N-propylpiperazine-N-(2-mercaptopropane-1-one) (SiO2@NPPNSH)] and Au nanoparticles (AuNPs). These nanoparticles are able to immobilize thiolated G-quadruplex DNA structures (SH-G4DNA). The SH groups on the SiO2@NPPNSH nanoparticles provide a good platform for stabilizing AuNPs on the surface of the electrode. This is due to the fact that AuNPs are able to bind to the organic SH groups on the SiO2@NPPNSH. The SH-G4DNA binds to the modified electrode by a AuNPs-S bond. The structure of SiO2@NPPNSH was characterized by scanning electron microscopy (SEM), thermo-gravimetric analysis (TGA) and infrared (IR) spectroscopy. The morphology of the modified electrode was characterized by SEM. The interaction between G4DNA and the anticancer drug, Tamoxifen (Tam), was studied in Tris-HCl buffer and [Fe(CN)6](3-) using cyclic (CV) and square wave voltammetry (SWV). The G-quadruplex formation and the interaction mechanism were identified by circular dichroism (CD) measurements. The CV current was seen to decrease with increasing concentration of Tam due to interaction between G4DNA and Tam. This biosensor is a simple and useful tool for selecting G-quadruplex-binding ligands.


Asunto(s)
Antineoplásicos/análisis , Técnicas Biosensibles/métodos , G-Cuádruplex , Nanopartículas/química , Nanotecnología/métodos , Telómero/química , Antineoplásicos/química , Secuencia de Bases , Técnicas Biosensibles/instrumentación , Electroquímica , Electrodos , Ferricianuros/química , Oro/química , Grafito/química , Humanos , Nanotecnología/instrumentación , Piperazina , Piperazinas/química , Dióxido de Silicio/química , Tamoxifeno/análisis , Tamoxifeno/química , Telómero/genética
14.
Anal Sci ; 30(9): 925-30, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25213822

RESUMEN

This paper describes a micellar liquid chromatographic method used to analyze tamoxifen (TAMO) in pharmaceutical formulations, while focusing in its interesting features. Solid samples were solved in a micellar solution, irradiated at 254 nm, filtered and injected. Extraction steps were avoided and thus expediting the procedure. Tamoxifen was resolved in <5 min, using a mobile phase containing 0.15 M sodium dodecyl sulfate-7% pentanol at pH 3, running at 1.5 mL/min under an isocratic mode at 40°C through a C18 column. Detection was achieved by fluorescence by excitation at 260 nm and emission at 380 nm. The validation was performed following the requirements of the International Conference on Harmonization (ICH) Tripartite Guidelines in terms of: specificity, sensitivity, calibration range (0.2 - 20 mg/L), accuracy (98.8 - 101.7%), precision (<1.5%) and robustness (<6.2%). The method was applied to quantify TAMO in TAMO citrate tablets supplied in Spain, and was found appropriate for the quality control of TAMO formulations.


Asunto(s)
Cromatografía Liquida/métodos , Preparaciones Farmacéuticas/química , Moduladores Selectivos de los Receptores de Estrógeno/análisis , Tamoxifeno/análisis , Cromatografía Liquida/instrumentación , Límite de Detección , Preparaciones Farmacéuticas/normas , Comprimidos
15.
Sensors (Basel) ; 14(5): 7647-54, 2014 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-24776936

RESUMEN

We present an electrochemical MIP sensor for tamoxifen (TAM)-a nonsteroidal anti-estrogen-which is based on the electropolymerisation of an O-phenylenediamine‒resorcinol mixture directly on the electrode surface in the presence of the template molecule. Up to now only "bulk" MIPs for TAM have been described in literature, which are applied for separation in chromatography columns. Electro-polymerisation of the monomers in the presence of TAM generated a film which completely suppressed the reduction of ferricyanide. Removal of the template gave a markedly increased ferricyanide signal, which was again suppressed after rebinding as expected for filling of the cavities by target binding. The decrease of the ferricyanide peak of the MIP electrode depended linearly on the TAM concentration between 1 and 100 nM. The TAM-imprinted electrode showed a 2.3 times higher recognition of the template molecule itself as compared to its metabolite 4-hydroxytamoxifen and no cross-reactivity with the anticancer drug doxorubucin was found. Measurements at +1.1 V caused a fouling of the electrode surface, whilst pretreatment of TAM with peroxide in presence of HRP generated an oxidation product which was reducible at 0 mV, thus circumventing the polymer formation and electrochemical interferences.


Asunto(s)
Técnicas Biosensibles/instrumentación , Conductometría/instrumentación , Electrodos , Impresión Molecular/métodos , Polímeros/química , Tamoxifeno/análisis , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Moduladores Selectivos de los Receptores de Estrógeno/análisis , Moduladores Selectivos de los Receptores de Estrógeno/química , Sensibilidad y Especificidad , Tamoxifeno/química
17.
Anal Bioanal Chem ; 405(18): 5937-52, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23462977

RESUMEN

In the present work, the development, optimization, and validation (including a whole stability study) of a fast, reliable, and comprehensive method for the analysis of ten anticancer drugs in hospital and urban wastewater is described. Extraction of these pharmaceutical compounds was performed using automated off-line solid-phase extraction followed by their determination by ultra-performance liquid chromatography coupled to a triple quadrupole-linear ion trap mass spectrometer. Target compounds include nine cytotoxic agents: cyclophosphamide, ifosfamide, docetaxel, paclitaxel, etoposide, vincristine, tamoxifen, methotrexate, and azathioprine; and the cytotoxic quinolone, ciprofloxacin. Method detection limits (MDL) ranged from 0.8 to 24 ng/L. Levels found of cytostatic agents in the hospital and wastewater influents did not differ significantly, and therefore, hospitals cannot be considered as the primary source of this type of contaminants. All the target compounds were detected in at least one of the influent samples analyzed: Ciprofloxacin, cyclophosphamide, tamoxifen, and azathioprine were found in most of them and achieving maximum levels of 14.725, 0.201, 0.133, and 0.188 µg/L, respectively. The rest of target cancer drugs were less frequently detected and at values ranging between MDL and 0.406 µg/L. Furthermore, a feasible, useful, and advantageous approach based on information acquisition tool (information-dependent acquisition) was used for the screening of human metabolites in hospital effluents, where the hydroxy tamoxifen, endoxifen, and carboxyphosphamide were detected.


Asunto(s)
Antineoplásicos/análisis , Antineoplásicos/metabolismo , Hospitales , Aguas del Alcantarillado/análisis , Espectrometría de Masas en Tándem/métodos , Contaminantes Químicos del Agua/análisis , Calibración , Cromatografía Liquida/métodos , Ciprofloxacina/análisis , Estabilidad de Medicamentos , Humanos , Procesamiento de Imagen Asistido por Computador , Límite de Detección , Eliminación de Residuos Sanitarios/métodos , Mostazas de Fosforamida/análisis , Mostazas de Fosforamida/metabolismo , Reproducibilidad de los Resultados , Programas Informáticos , Extracción en Fase Sólida/métodos , España , Tamoxifeno/análogos & derivados , Tamoxifeno/análisis , Espectrometría de Masas en Tándem/instrumentación
18.
Electrophoresis ; 34(3): 463-70, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23161341

RESUMEN

A selective and low-cost CD-MEKC method under acidic conditions was developed for investigating the N-oxygenation of tamoxifen (TAM) by flavin-containing monooxygenases (FMOs). The inhibitory effects of methimazole (MMI), nicotine and 5,6-dimethylxanthenone-4-acetic acid (DMXAA) on the given FMO reaction were also evaluated; 100 mM phosphate buffer (pH 8.6) was used for performing the enzymatic reaction and the separation of TAM and its metabolite tamoxifen N-oxide (TNO) was obtained with a BGE consisting of 100 mM phosphoric acid solution adjusted to pH 2.5 with triethanolamine containing 50 mM sodium taurodeoxycholate, 20 mM carboxymethyl ß-CD and 20% ACN. The proposed method was applied for the kinetics study of FMO1 using TAM as a substrate probe. A Michaelis-Menten constant (K(m)) of 164.1 µM was estimated from the corrected peak area of the product, TNO. The calculated value of the maximum reaction velocity (V(max)) was 3.61 µmol/min/µmol FMO1; 50% inhibitory concentration and inhibition constant (K(i)) of MMI, the most common alternate substrate FMO inhibitor, were evaluated and the inhibitory effects of two other important FMO substrates, nicotine and DMXAA, a novel anti-tumour agent, were investigated.


Asunto(s)
Cromatografía Capilar Electrocinética Micelar/métodos , Metimazol/farmacología , Nicotina/farmacología , Oxigenasas/antagonistas & inhibidores , Oxigenasas/metabolismo , Tamoxifeno/análisis , Xantonas/farmacología , Ciclodextrinas/farmacología , Humanos , Reproducibilidad de los Resultados , Tamoxifeno/metabolismo
19.
Mater Sci Eng C Mater Biol Appl ; 33(2): 583-7, 2013 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-25427459

RESUMEN

Amperometric biosensor based on horseradish peroxidase immobilized via glutaraldehyde on the polyaniline modified platinum electrode shows evidenced promising characteristics in detecting anticancer drug tamoxifen. The sensor was fabricated simply by adsorbing horseradish peroxidase enzyme on the electrode surface for which Cyclic Voltammetry was used to monitor the electro-catalytic reduction of tamoxifen under diffusion-adsorption controlled conditions. Fourier Transform Infrared Spectroscopy, Cyclic Voltammetry and Electrochemical Impedance Spectroscopic techniques are used to characterize the electrochemical interfacial properties of surface modified electrodes. The first-hand effort on modified biosensor within Platinum/Polyaniline/Horseradish peroxidase biosensor system has demonstrated excellent electro-analytical properties with biosensor sensitivity of 1.6 µA ng mL(-1). The optimum limit of detection and limit of quantification are 0.07 ng mL(-1) and 0.29 ng mL(-1) respectively for the determination of anticancer drug tamoxifen. It is felt that the present study will help in improving our knowledge of cost-effective quantitative determination of tamoxifen in metabolized biological fluids and other pharmaceutical formulations.


Asunto(s)
Compuestos de Anilina/química , Antineoplásicos/análisis , Técnicas Biosensibles/métodos , Enzimas Inmovilizadas/química , Peroxidasa de Rábano Silvestre/química , Tamoxifeno/análisis , Enzimas Inmovilizadas/metabolismo , Peroxidasa de Rábano Silvestre/metabolismo , Límite de Detección , Análisis de Regresión , Reproducibilidad de los Resultados
20.
J Environ Sci (China) ; 23(2): 301-6, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21517005

RESUMEN

Environmental chemicals in drinking water can impact human health through nuclear receptors. Additionally, estrogen-related receptors (ERRs) are vulnerable to endocrine-disrupting effects. To date, however, ERR disruption of drinking water potency has not been reported. We used ERRgamma two-hybrid yeast assay to screen ERRgamma disrupting activities in a drinking water treatment plant (DWTP) located in north China and in source water from a reservoir, focusing on agonistic, antagonistic, and inverse agonistic activity to 4-hydroxytamoxifen (4-OHT). Water treatment processes in the DWTP consisted of pre-chlorination, coagulation, coal and sand filtration, activated carbon filtration, and secondary chlorination processes. Samples were extracted by solid phase extraction. Results showed that ERRgamma antagonistic activities were found in all sample extracts, but agonistic and inverse agonistic activity to 4-OHT was not found. When calibrated with the toxic equivalent of 4-OHT, antagonistic effluent effects ranged from 3.4 to 33.1 microg/L. In the treatment processes, secondary chlorination was effective in removing ERRgamma antagonists, but the coagulation process led to significantly increased ERRgamma antagonistic activity. The drinking water treatment processes removed 73.5% of ERRgamma antagonists. To our knowledge, the occurrence of ERRgamma disruption activities on source and drinking water in vitro had not been reported previously. It is vital, therefore, to increase our understanding of ERRy disrupting activities in drinking water.


Asunto(s)
Receptores de Estrógenos/análisis , Contaminantes Químicos del Agua/análisis , Abastecimiento de Agua , Calibración , Cromatografía Líquida de Alta Presión , Receptores de Estrógenos/antagonistas & inhibidores , Tamoxifeno/análogos & derivados , Tamoxifeno/análisis , Tamoxifeno/farmacología , Técnicas del Sistema de Dos Híbridos , Contaminantes Químicos del Agua/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA