Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.387
Filtrar
Más filtros











Intervalo de año de publicación
2.
Langenbecks Arch Surg ; 409(1): 170, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38822883

RESUMEN

PURPOSE: Perioperative decision making for large (> 2 cm) rectal polyps with ambiguous features is complex. The most common intraprocedural assessment is clinician judgement alone while radiological and endoscopic biopsy can provide periprocedural detail. Fluorescence-augmented machine learning (FA-ML) methods may optimise local treatment strategy. METHODS: Surgeons of varying grades, all performing colonoscopies independently, were asked to visually judge endoscopic videos of large benign and early-stage malignant (potentially suitable for local excision) rectal lesions on an interactive video platform (Mindstamp) with results compared with and between final pathology, radiology and a novel FA-ML classifier. Statistical analyses of data used Fleiss Multi-rater Kappa scoring, Spearman Coefficient and Frequency tables. RESULTS: Thirty-two surgeons judged 14 ambiguous polyp videos (7 benign, 7 malignant). In all cancers, initial endoscopic biopsy had yielded false-negative results. Five of each lesion type had had a pre-excision MRI with a 60% false-positive malignancy prediction in benign lesions and a 60% over-staging and 40% equivocal rate in cancers. Average clinical visual cancer judgement accuracy was 49% (with only 'fair' inter-rater agreement), many reporting uncertainty and higher reported decision confidence did not correspond to higher accuracy. This compared to 86% ML accuracy. Size was misjudged visually by a mean of 20% with polyp size underestimated in 4/6 and overestimated in 2/6. Subjective narratives regarding decision-making requested for 7/14 lesions revealed wide rationale variation between participants. CONCLUSION: Current available clinical means of ambiguous rectal lesion assessment is suboptimal with wide inter-observer variation. Fluorescence based AI augmentation may advance this field via objective, explainable ML methods.


Asunto(s)
Colonoscopía , Neoplasias del Recto , Humanos , Neoplasias del Recto/patología , Neoplasias del Recto/cirugía , Neoplasias del Recto/diagnóstico por imagen , Pólipos Intestinales/patología , Pólipos Intestinales/cirugía , Aprendizaje Automático , Masculino , Fluorescencia , Femenino , Variaciones Dependientes del Observador
3.
Sci Rep ; 14(1): 12133, 2024 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-38802436

RESUMEN

Epithelial ovarian cancer is mostly discovered at the stage of peritoneal carcinosis. Complete cytoreductive surgery improves overall survival. The Fagotti score is a predictive score of resectability based on peritoneal laparoscopic exploratory. Our aim was to study the inter-observer concordance in an external validation of the Fagotti score. An observational, prospective, multicenter study was conducted using the Francogyn research network. The primary outcome was inter-observer concordance of the Fagotti score. 15 patients in which an ovarian mass was discovered were included. For each patient, the first exploratory laparoscopy before any treatment/chemotherapy was recorded. This bank of 15 videos was subject to blind review accompanied by a Fagotti score rating by 11 gynecological surgeons specializing in oncology. A total of 165 blind reviews were performed. Inter-observer concordance was very good for the Fagotti score with an intraclass correlation coefficient (ICC) of 0.83 [95% CI 0.71; 0.93]. Inter-observer concordance for the adjusted Fagotti score, which accounts for unexplorable areas with extensive carcinomatosis, resulted in an ICC of 0.64 [95% CI 0.46; 0.82]. According to the reviewers, the three least explorable parameters were mesentery involvement, stomach infiltration and liver damage. The ICC of the explorable Fagotti score, i.e. score with deletion of the parameters most often unexplored by laparoscopy, was 0.86 [0.75-0.94]. This study confirms the reproducibility of the Fagotti score during first assessment laparoscopies in cases of advanced ovarian cancer. The explorable Fagotti score has an equivalent or better inter-observer concordance than the Fagotti score.


Asunto(s)
Neoplasias Ováricas , Humanos , Femenino , Neoplasias Ováricas/patología , Neoplasias Ováricas/mortalidad , Neoplasias Ováricas/cirugía , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Laparoscopía , Variaciones Dependientes del Observador , Procedimientos Quirúrgicos de Citorreducción , Carcinoma Epitelial de Ovario/patología , Carcinoma Epitelial de Ovario/mortalidad , Adulto , Reproducibilidad de los Resultados
4.
Jt Dis Relat Surg ; 35(2): 324-329, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38727111

RESUMEN

OBJECTIVES: This study aims to evaluate the inter-observer reliability of fibula-condyle-patella angle measurements and to compare it with other measurement techniques. PATIENTS AND METHODS: Between January 01, 2023 and January 31, 2023, a total of 108 patients (20 males, 88 females; mean age: 47.5±12.0 years; range, 18 to 72 years) who underwent X-rays using the fibula-condyle-patella angle, Insall-Salvati, Caton-Deschamps, Blackburne-Pell, and plateau-patella angle (PPA) methods were retrospectively analyzed. Knee lateral radiographs taken in at least 30 degrees of flexion and appropriate rotation were scanned. All measurements were made by two orthopedic surgeons who were blinded to measurement methods. RESULTS: Right knee patellar height measurements were conducted in 56 patients, while left knee patellar heights were assessed in 52 patients. The highest inter-observer concordance was found in the fibula-condyle-patella angle. The second highest concordance was found in the Insall-Salvati. The highest concordance correlation was found with PPA in the measurements of both researchers. CONCLUSION: The fibula-condyle-patella angle is a reliable technique with a good inter-observer reliability for measuring patellar height. We believe that this study will inspire future research to establish comprehensive reference values for clinical applications.


Asunto(s)
Peroné , Variaciones Dependientes del Observador , Rótula , Humanos , Femenino , Masculino , Peroné/diagnóstico por imagen , Peroné/anatomía & histología , Adulto , Rótula/diagnóstico por imagen , Rótula/anatomía & histología , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Adolescente , Adulto Joven , Reproducibilidad de los Resultados , Radiografía/métodos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/anatomía & histología
5.
Pathol Res Pract ; 257: 155311, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38636444

RESUMEN

The Silva pattern-based classification of HPV-associated endocervical adenocarcinoma has become an integral part of the histologic assessment of these tumors. Unfortunately, the Silva system reproducibility has had mixed results in past studies, and clinical practice still favors the FIGO stage assessment in directing therapeutic interventions for patients. In our study, we aimed to assess our institution's concordance including not only gynecologic pathologists, but also pathology trainees through a series of 69 cases. The grouped total kappa concordance from all participants was 0.439 (Moderate), with an overall trainee kappa of 0.417 (moderate) and an overall pathologist kappa of 0.460 (moderate). Perfect concordance among all 10 study participants was seen in 8/69 cases (11.6 %), corresponding to 5/22 Pattern A cases (22.7 %), 0/16 Pattern B cases (0 %), and 3/31 Pattern C cases (9.7 %), with similar findings between trainees and pathologists when compared within their own cohorts. Recurrence was identified in 2 Pattern A cases, indicating a potential issue with limited excisional specimens which may not fully appreciate the true biologic aggressiveness of the lesions.


Asunto(s)
Adenocarcinoma , Infecciones por Papillomavirus , Patólogos , Neoplasias del Cuello Uterino , Humanos , Femenino , Neoplasias del Cuello Uterino/virología , Neoplasias del Cuello Uterino/patología , Adenocarcinoma/virología , Adenocarcinoma/patología , Infecciones por Papillomavirus/patología , Infecciones por Papillomavirus/virología , Infecciones por Papillomavirus/complicaciones , Adulto , Persona de Mediana Edad , Ginecología/educación , Reproducibilidad de los Resultados , Variaciones Dependientes del Observador , Anciano
6.
Hum Pathol ; 146: 75-85, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38640986

RESUMEN

INTRODUCTION: Semi-quantitative scoring of various parameters in renal biopsy is accepted as an important tool to assess disease activity and prognostication. There are concerns on the impact of interobserver variability in its prognostic utility, generating a need for computerized quantification. METHODS: We studied 94 patients with renal biopsies, 45 with native diseases and 49 transplant patients with index biopsies for Polyomavirus nephropathy. Chronicity scores were evaluated using two methods. A standard definition diagram was agreed after international consultation and four renal pathologists scored each parameter in a double-blinded manner. Interstitial fibrosis (IF) score was assessed with five different computerized and AI-based algorithms on trichrome and PAS stains. RESULTS: There was strong prognostic correlation with renal function and graft outcome at a median follow-up ranging from 24 to 42 months respectively, independent of moderate concordance for pathologists scores. IF scores with two of the computerized algorithms showed significant correlation with estimated glomerular filtration rate (eGFR) at biopsy but not at the end of follow-up. There was poor concordance for AI based platforms. CONCLUSION: Chronicity scores are robust prognostic tools despite interobserver reproducibility. AI-algorithms have absolute precision but are limited by significant variation when different hardware and software algorithms are used for quantification.


Asunto(s)
Inteligencia Artificial , Riñón , Variaciones Dependientes del Observador , Humanos , Biopsia , Reproducibilidad de los Resultados , Riñón/patología , Masculino , Femenino , Pronóstico , Persona de Mediana Edad , Microscopía/métodos , Interpretación de Imagen Asistida por Computador/métodos , Adulto , Algoritmos , Tasa de Filtración Glomerular , Fibrosis/patología , Valor Predictivo de las Pruebas , Enfermedades Renales/patología , Enfermedades Renales/diagnóstico , Trasplante de Riñón , Anciano , Infecciones por Polyomavirus/patología
7.
Acta Radiol ; 65(5): 506-512, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38591942

RESUMEN

BACKGROUND: Apparent diffusion coefficient (ADC) value is an important part of bladder cancer magnetic resonance imaging (MRI) assessment and can predict the aggressive and invasive potentials. There is growing interest in whole tumor volume measurements. PURPOSE: To investigate if the volumetric ADC measurement method will significantly exceed the diagnostic performance of the selected region of interest (ROI) method in everyday practice. MATERIAL AND METHODS: A prospective evaluation was carried out of 50 patients with bladder cancer by two radiologists. The mean and the minimum ADC values were measured using both methods. The inter-reader agreement was determined by the intraclass correlation coefficient. The ADC values were compared between different grades, states of muscle invasion, and lympho-vascular invasion (LVI); then, validity was evaluated using receiver operating characteristic (ROC) curves. Areas under the curve (AUC) were then compared for the level of statistical significance. RESULTS: The inter-observer agreement was excellent for the ADC values using both methods. The volumetric measurement provides higher mean and lower minimum ADC values with statistically significant differences (P <0.00001). The highest diagnostic accuracy for differentiating tumor grade and predicting muscle invasion was for the minimum ADC by a selected ROI. However, the differences between the achieved AUCs were of no statistical significance. None of the ADC values predicted LVI with statistical significance. CONCLUSION: The selected ROI and volumetric measurement methods of mean and minimum ADC in bladder cancer yield different values, still having comparable diagnostic performance with accurate ROI sampling. The minimum ADC value by ROI is preferred in everyday clinical practice.


Asunto(s)
Neoplasias de la Vejiga Urinaria , Humanos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Femenino , Masculino , Anciano , Persona de Mediana Edad , Estudios Prospectivos , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Adulto , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Carga Tumoral , Variaciones Dependientes del Observador , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/patología , Invasividad Neoplásica/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos
8.
Knee Surg Sports Traumatol Arthrosc ; 32(6): 1548-1556, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38613184

RESUMEN

PURPOSE: Accurate assessment of the knee joint line is essential for surgeries involving the knee. The knee joint line obliquity (KJLO) is a radiological measurement that evaluates the position of the knee joint relative to the ground and is frequently used in preoperative planning and clinical follow-up. On the other hand, coronal plane alignment of the knee (CPAK) classifications assesses the joint line as the summation of the medial proximal tibial angle (MPTA) and mechanical lateral distal femoral angle (mLDFA). The purpose of this study is to determine the concordance of these two measurement techniques. METHODS: This cross-sectional study evaluated the long-leg standing radiographs (LSRs) of 164 healthy knees. The extremity KJLO and CPAK classification JLO were measured twice by two observers at 8-week intervals. The knee joint line apex positions (proximal, neutral and distal) of the two measurement techniques are compared (concordance or discordant). The intraobserver and interobserver reliability were examined using the intraclass correlation coefficient (ICC). Possible causes of the discordant were evaluated with univariate and multivariate logistic regression analysis. RESULTS: CPAK classification detected the KJLO apex position in 70 extremities (42.7%) only. Subgroups CPAK JLO detected 13.6% of the proximal apex, 20.4% of the neutral, and 90.7% of the distal apex (p < 0.01). Upon multivariate logistic regression analysis, the variable KJLO apex position (proximal, neutral vs. distal, odds ratio (OR) = 10.291, 95% confidence interval [CI] = 2.225-25.656, and (p < 0.01) was determined as a risk factor for discordant. CONCLUSION: The CPAK JLO measurement technique can be misleading in defining the KJLO apex position and the concordance between them is less than 50%. It has a high tendency to misleadingly predict proximal and neutral apex positions, which can potentially have negative implications for assessing the joint line. LEVEL OF EVIDENCE: Level I.


Asunto(s)
Articulación de la Rodilla , Radiografía , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Estudios Transversales , Masculino , Femenino , Adulto , Reproducibilidad de los Resultados , Persona de Mediana Edad , Tibia/diagnóstico por imagen , Tibia/anatomía & histología , Adulto Joven , Fémur/diagnóstico por imagen , Fémur/anatomía & histología , Variaciones Dependientes del Observador
9.
Knee Surg Sports Traumatol Arthrosc ; 32(6): 1462-1469, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38629758

RESUMEN

PURPOSE: The aim of this study was to investigate whether malrotation of lateral knee radiographs influences posterior tibial slope (PTS) measurements. METHODS: Lateral knee radiographs of all patients who underwent knee surgery at a single institution between June 2022 and January 2023 and received multiple lateral knee radiographs were included. Radiographs were categorised as malrotated lateral knee radiographs or lateral knee radiographs based on the radiographic distance between the medial and lateral posterior femoral condyles. Medial PTS (MPTS) and lateral PTS (LPTS) were evaluated on malrotated lateral knee radiographs and lateral knee radiographs and compared using the paired t test. Intra- and interrater reliability between four raters were assessed for MPTS and LPTS measurements. RESULTS: A total of 92 lateral knee radiographs (46 pairs of malrotated lateral knee radiographs and lateral knee radiographs; 50.0% right side) from 46 patients (33.2 ± 12.4 years, 69.6% male) were included. Mean posterior femoral condyle distance in malrotated lateral knee radiographs was 8.1 ± 4.4 mm. Overall, MPTS and LPTS were significantly higher on malrotated lateral knee radiographs versus lateral knee radiographs (medial: 10.5 ± 3.2° vs. 9.7 ± 3.5°, p < 0.05; lateral: 10.6 ± 3.4° vs. 9.7 ± 3.3°, p < 0.05). Mean absolute difference between MPTS and LPTS on malrotated lateral knee radiographs versus lateral knee radiographs were |1.9| ± |1.5|° and |2.0| ± |1.8|°, respectively. Intrarater reliability was 'moderate' and interrater reliability was 'good' for both MPTS and LPTS. CONCLUSION: Malrotation of lateral knee radiographs led to a significant distortion of both the MPTS and LPTS. In clinical practice, attention should be placed on the (mal)rotation of lateral knee radiographs, especially in patients for whom a slope-correcting osteotomy is being discussed. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Articulación de la Rodilla , Radiografía , Tibia , Humanos , Masculino , Femenino , Adulto , Tibia/diagnóstico por imagen , Tibia/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Reproducibilidad de los Resultados , Estudios Retrospectivos , Persona de Mediana Edad , Adulto Joven , Variaciones Dependientes del Observador
10.
Am J Surg Pathol ; 48(6): 708-718, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38590014

RESUMEN

Next-generation sequencing (NGS) is increasingly being utilized as an ancillary tool for diagnostically challenging melanocytic neoplasms. It is incumbent upon the pathology community to perform studies assessing the benefits and limitations of these tools in specific diagnostic scenarios. One of the most challenging diagnostic scenarios faced by skin pathologists involves accurate diagnosis of desmoplastic melanocytic neoplasms (DMNs). In this study, 20 expert melanoma pathologists rendered a diagnosis on 47 DMNs based on hematoxylin and eosin sections with demographic information. After submitting their diagnosis, the experts were given the same cases, but this time with comprehensive genomic sequencing results, and asked to render a diagnosis again. Identification of desmoplastic melanoma (DM) improved by 7%, and this difference was statistically significant ( P <0.05). In addition, among the 15 melanoma cases, in the pregenomic assessment, only 12 were favored to be DM by the experts, while after genomics, this improved to 14 of the cases being favored to be DM. In fact, some cases resulting in metastatic disease had a substantial increase in the number of experts recognizing them as DM after genomics. The impact of the genomic findings was less dramatic among benign and intermediate-grade desmoplastic tumors (BIDTs). Interobserver agreement also improved, with the Fleiss multirater Kappa being 0.36 before genomics to 0.4 after genomics. NGS has the potential to improve diagnostic accuracy in the assessment of desmoplastic melanocytic tumors. The degree of improvement will be most substantial among pathologists with some background and experience in bioinformatics and melanoma genetics.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento , Melanoma , Variaciones Dependientes del Observador , Neoplasias Cutáneas , Humanos , Melanoma/genética , Melanoma/diagnóstico , Melanoma/patología , Neoplasias Cutáneas/genética , Neoplasias Cutáneas/patología , Neoplasias Cutáneas/diagnóstico , Femenino , Masculino , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Persona de Mediana Edad , Adulto , Anciano , Patólogos , Biomarcadores de Tumor/genética
11.
Eur J Radiol ; 175: 111463, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38615502

RESUMEN

PURPOSE: To investigate inter-reader agreement, and diagnostic performance of the Prostate Imaging after Focal Ablation (PI-FAB) score applied to multiparametric MRI (mpMRI) in patients who underwent focal high-intensity focused ultrasound (HIFU) therapy for localized prostate cancer. METHODS: In this retrospective, IRB-approved, single-center study, 73 men, who underwent focal HIFU treatment and received follow-up mpMRIs with subsequent prostate biopsies, were included. The PI-FAB score was applied to follow-up MRIs at 6, 12, and 36 months post-HIFU by two radiologists with different experience levels. Inter-reader agreement was assessed using Gwet's AC1, and the diagnostic performance of the PI-FAB score was assessed in relation to histopathologic results of subsequent prostate biopsies for each reader. RESULTS: PI-FAB scores showed substantial to almost perfect inter-reader agreement (AC1: 0.80-0.95) and demonstrated high specificity (Reader 1: 90-98 %, Reader 2: 87-98 %) and NPVs (Reader 1: 91-100 %, Reader 2: 88-97 %) in ruling out residual or recurrent in-field prostate cancer post-HIFU. Sensitivity (Reader 1: ≥43 %, Reader 2: ≥14 %) and PPVs (Reader 1: ≥33 %, Reader 2: ≥14 %) were mostly relatively lower, with notable disparities between the two readers, indicating the potential influence of radiologist experience. CONCLUSIONS: The PI-FAB score provides a consistent and reliable tool for post-HIFU monitoring of prostate cancer using mpMRI. It demonstrates substantial to almost perfect inter-reader agreement and is particularly effective in excluding in-field residual or recurrent prostate cancer post-HIFU treatment. Its application can potentially enhance post-treatment patient care, emphasizing its value as a non-invasive MRI-based monitoring approach after focal ablative therapy of the prostate.


Asunto(s)
Variaciones Dependientes del Observador , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/terapia , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Sensibilidad y Especificidad , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Resultado del Tratamiento , Reproducibilidad de los Resultados
12.
Arch Orthop Trauma Surg ; 144(5): 2267-2271, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38587669

RESUMEN

The symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer. The objective was to determine the detection threshold and interobserver reliability of this technique. In an in vitro setting with a human cadaveric knee, gap asymmetries were simulated by different medially and laterally applied forces. Using an optical measurement system, the pivot point of the spacer was calculated as a function of the gap symmetry in the first part of the experiment. In the second part, the detection threshold and interobserver reliability of 4 surgeons were determined. For this purpose, gap asymmetries were adjusted to between 0 and 120N in a blinded trial. With a symmetrical gap, the centre of rotation of the spacer was located in the centre of the tibia. With increasing gap asymmetry, the centre of rotation of the spacer shifted to the tight side. This shift was approximately linearly dependent on the force difference. A perfectly balanced gap was detected by the examiners in 50% of the cases. From a force difference of 40N, all examiners identified the gap asymmetry in all cases (ICC = 1.0). The method of spacer rotation described is suitable for reliably detecting gap differences at ≥ 40N, independently of the examiner.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Cadáver , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Rotación , Prótesis de la Rodilla , Rango del Movimiento Articular , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/fisiopatología , Fenómenos Biomecánicos , Variaciones Dependientes del Observador
13.
PLoS One ; 19(4): e0302252, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38683770

RESUMEN

OBJECTIVE: Reproducible diagnoses of endometrial hyperplasia (EH) remains challenging and has potential implications for patient management. This systematic review aimed to identify pathologist-specific factors associated with interobserver variation in the diagnosis and reporting of EH. METHODS: Three electronic databases, namely MEDLINE, Embase and Web of Science, were searched from 1st January 2000 to 25th March 2023, using relevant key words and subject headings. Eligible studies reported on pathologist-specific factors or working practices influencing interobserver variation in the diagnosis of EH, using either the World Health Organisation (WHO) 2014 or 2020 classification or the endometrioid intraepithelial neoplasia (EIN) classification system. Quality assessment was undertaken using the QUADAS-2 tool, and findings were narratively synthesised. RESULTS: Eight studies were identified. Interobserver variation was shown to be significant even amongst specialist gynaecological pathologists in most studies. Few studies investigated pathologist-specific characteristics, but pathologists were shown to have different diagnostic styles, with some more likely to under-diagnose and others likely to over-diagnose EH. Some novel working practices were identified, such as grading the "degree" of nuclear atypia and the incorporation of objective methods of diagnosis such as semi-automated quantitative image analysis/deep learning models. CONCLUSIONS: This review highlighted the impact of pathologist-specific factors and working practices in the accurate diagnosis of EH, although few studies have been conducted. Further research is warranted in the development of more objective criteria that could improve reproducibility in EH diagnostic reporting, as well as determining the applicability of novel methods such as grading the degree of nuclear atypia in clinical settings.


Asunto(s)
Hiperplasia Endometrial , Variaciones Dependientes del Observador , Patólogos , Humanos , Femenino , Hiperplasia Endometrial/diagnóstico , Hiperplasia Endometrial/patología , Neoplasias Endometriales/diagnóstico , Neoplasias Endometriales/patología
14.
Virchows Arch ; 484(4): 597-608, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38570364

RESUMEN

Assessing programmed death ligand 1 (PD-L1) expression on tumor cells (TCs) using Food and Drug Administration-approved, validated immunoassays can guide the use of immune checkpoint inhibitor (ICI) therapy in cancer treatment. However, substantial interobserver variability has been reported using these immunoassays. Artificial intelligence (AI) has the potential to accurately measure biomarker expression in tissue samples, but its reliability and comparability to standard manual scoring remain to be evaluated. This multinational study sought to compare the %TC scoring of PD-L1 expression in advanced urothelial carcinoma, assessed by either an AI Measurement Model (AIM-PD-L1) or expert pathologists. The concordance among pathologists and between pathologists and AIM-PD-L1 was determined. The positivity rate of ≥ 1%TC PD-L1 was between 20-30% for 8/10 pathologists, and the degree of agreement and scoring distribution for among pathologists and between pathologists and AIM-PD-L1 was similar both scored as a continuous variable or using the pre-defined cutoff. Numerically higher score variation was observed with the 22C3 assay than with the 28-8 assay. A 2-h training module on the 28-8 assay did not significantly impact manual assessment. Cases exhibiting significantly higher variability in the assessment of PD-L1 expression (mean absolute deviation > 10) were found to have patterns of PD-L1 staining that were more challenging to interpret. An improved understanding of sources of manual scoring variability can be applied to PD-L1 expression analysis in the clinical setting. In the future, the application of AI algorithms could serve as a valuable reference guide for pathologists while scoring PD-L1.


Asunto(s)
Inteligencia Artificial , Antígeno B7-H1 , Biomarcadores de Tumor , Variaciones Dependientes del Observador , Humanos , Antígeno B7-H1/análisis , Antígeno B7-H1/metabolismo , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/metabolismo , Reproducibilidad de los Resultados , Carcinoma de Células Transicionales/patología , Carcinoma de Células Transicionales/metabolismo , Carcinoma de Células Transicionales/diagnóstico , Neoplasias de la Vejiga Urinaria/patología , Neoplasias de la Vejiga Urinaria/metabolismo , Neoplasias Urológicas/patología , Neoplasias Urológicas/metabolismo , Inmunohistoquímica/métodos , Patólogos , Urotelio/patología , Urotelio/metabolismo
15.
Ann Diagn Pathol ; 70: 152288, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38452457

RESUMEN

CONTEXT: Recent clinical trials indicate that HER2-targeted therapy may benefit HER2-low breast cancer patients including HER2 score 1+ or 2+ and no gene amplification. Concordance between pathologists and between core biopsy and surgical excision in establishing HER2-low status was evaluated. DESIGN: 57 patients with HER2 negative breast cancer (IHC 0, 1+, or 2+, no gene amplification) by core biopsy were included. Core biopsy and representative tumor from corresponding surgical excision was immunostained for HER2. Original HER2 IHC scores were interpreted using 2018 guidelines. Three pathologists independently interpreted again under 2023 guidelines. Kappa statistic evaluated agreement of HER2 IHC scores. RESULTS: Applying 2023 guidelines, HER2 IHC scores were concordant among study pathologists in 46 of 57 (81 %) core biopsy and 50 of 57 (88 %) surgical resections. Kappa statistics were 0.78 and 0.85 (substantial agreement), for inter-pathologist agreement of core biopsy and surgical resections under 2023 guidelines; 0.55 (moderate agreement) for agreement between first interpretation by 2018 guidelines and second interpretation by 2023 guidelines; and 0.13 (slight agreement) for agreement in HER2 consensus scores between outside core and surgical resection and 0.49 (moderate agreement) for inside core and surgical resection. Low HER2 expression was found in 28 of 57 (49 %) core biopsy and in 25 of 57 (44 %) surgical excisions. CONCLUSIONS: Interobserver agreement among study pathologists was good in core biopsy and surgical excisions, applying updated 2023 guidelines. Intratumoral heterogeneity in protein expression and preanalytical factors may result in variable identification of HER2-low status in core biopsy and surgical excision specimens.


Asunto(s)
Neoplasias de la Mama , Inmunohistoquímica , Patólogos , Receptor ErbB-2 , Humanos , Neoplasias de la Mama/patología , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/diagnóstico , Receptor ErbB-2/metabolismo , Femenino , Inmunohistoquímica/métodos , Biomarcadores de Tumor/metabolismo , Persona de Mediana Edad , Biopsia con Aguja Gruesa/métodos , Variaciones Dependientes del Observador , Adulto , Anciano
16.
Breast Cancer Res Treat ; 205(2): 403-411, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38441847

RESUMEN

PURPOSE: The recent findings from the DESTINY-Breast04 trial highlighted the clinical importance of distinguishing between HER2 immunohistochemistry (IHC) scores 0 and 1 + in metastatic breast cancer (BC). However, pathologist interpretation of HER2 IHC scoring is subjective, and standardized methodology is needed. We evaluated the consistency of HER2 IHC scoring among pathologists and the accuracy of digital image analysis (DIA) in interpreting HER2 IHC staining in cases of HER2-low BC. METHODS: Fifty whole-slide biopsies of BC with HER2 IHC staining were evaluated, comprising 25 cases originally reported as IHC score 0 and 25 as 1 +. These slides were digitally scanned. Six pathologists with breast expertise independently reviewed and scored the scanned images, and DIA was applied. Agreement among pathologists and concordance between pathologist scores and DIA results were statistically analyzed using Kendall coefficient of concordance (W) tests. RESULTS: Substantial agreement among at least five of the six pathologists was found for 18 of the score 0 cases (72%) and 15 of the score 1 + cases (60%), indicating excellent interobserver agreement (W = 0.828). DIA scores were highly concordant with pathologist scores in 96% of cases (47/49), indicating excellent concordance (W = 0.959). CONCLUSION: Although breast subspecialty pathologists were relatively consistent in evaluating BC with HER2 IHC scores of 0 and 1 +, DIA may be a reliable supplementary tool to enhance the standardization and quantification of HER2 IHC assessment, especially in challenging cases where results may be ambiguous (i.e., scores 0-1 +). These findings hold promise for improving the accuracy and consistency of HER2 testing.


Asunto(s)
Neoplasias de la Mama , Inmunohistoquímica , Variaciones Dependientes del Observador , Receptor ErbB-2 , Humanos , Neoplasias de la Mama/patología , Neoplasias de la Mama/metabolismo , Receptor ErbB-2/metabolismo , Femenino , Inmunohistoquímica/métodos , Reproducibilidad de los Resultados , Biomarcadores de Tumor/metabolismo , Biomarcadores de Tumor/análisis , Procesamiento de Imagen Asistido por Computador/métodos
17.
Knee Surg Sports Traumatol Arthrosc ; 32(6): 1363-1369, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38532466

RESUMEN

PURPOSE: Trochlear dysplasia is one of the main risk factors for recurrent patellar dislocation. The Dejour classification identifies four categories that can be used to classify trochlear dysplasia. The purpose of this study is to evaluate the inter- and intraobserver reliability of the Dejour classification for trochlear dysplasia. The hypothesis was that both intra- and interobserver reliability would be at least moderate. METHODS: This is a cross-sectional, reliability study. Twenty-eight examiners from the International Patellofemoral Study Group 2022 meeting evaluated lateral radiographs of the knee and axial magnetic resonance images from 15 cases of patellofemoral instability with trochlear dysplasia. They classified each case according to Dejour's classification for trochlear dysplasia (A-D). There were three rounds: one with only computed radiograph (CR), one with only magnetic resonance imaging (MRI) and one with both. Inter- and intraobserver reliability were calculated using κ coefficient (0-1). RESULTS: The mean age of patients was: 14.6 years; 60% were female and 53% had open physis. The interobserver reliability κ probabilities were 0.2 (CR), 0.13 (MRI) and 0.12 (CR and MRI). The intraobserver reliability κ probabilities were 0.45 (CR), 0.44 (MRI) and 0.65 (CR and MRI). CONCLUSION: The Dejour classification for trochlear dysplasia has slight interobserver reliability and substantial intraobserver reliability. LEVEL OF EVIDENCE: Level I.


Asunto(s)
Imagen por Resonancia Magnética , Variaciones Dependientes del Observador , Articulación Patelofemoral , Humanos , Estudios Transversales , Femenino , Reproducibilidad de los Resultados , Adolescente , Masculino , Articulación Patelofemoral/diagnóstico por imagen , Articulación Patelofemoral/patología , Luxación de la Rótula/diagnóstico por imagen , Luxación de la Rótula/clasificación , Inestabilidad de la Articulación/clasificación , Inestabilidad de la Articulación/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Fémur/diagnóstico por imagen , Fémur/patología , Niño
18.
Magn Reson Imaging ; 110: 17-22, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38452829

RESUMEN

PURPOSE: To compare the image quality of multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) and single-shot echo-planar imaging (SS-EPI-DWI) techniques in uterine MRI. METHODS: Eighty-eight eligible patients underwent MUSE-DWI and SS-EPI-DWI examinations simultaneously using a 3.0 T MRI system. Two radiologists independently performed quantitative and qualitative analysis of the two groups of images using a double-blind method. The weighted Kappa test was used to evaluate the interobserver agreement. Wilcoxon's rank sum test was used for qualitative parameters, and paired t-test was used for quantitative parameters. Spearman rank correlation analysis was used to obtained correlation between pathological results and mean apparent diffusion coefficient (ADC) value. RESULTS: The qualitative and quantitative analysis of the images by the two radiologists were in good or excellent agreement, with weighted kappa value ranging from 0.636 to 0.981. The scores of total subjective image quality (15.4 ± 0.99) and signal-to-noise ratio (158.99 ± 60.71) of MUSE-DWI were significantly higher than those of SS-EPI-DWI (12.93 ± 1.62 P < 0.001; 130.23 ± 48.29 P < 0.05). It effectively reduced image distortion and artifact, and had better lesion conspicuity. There was no significant difference in contrast-to-noise ratio score and average ADC values between the two DWI sequences. The average ADC values of the two DWI sequences were highest in the normal uterus group and lowest in the endometrial cancer group, with statistically significant differences among groups (P < 0.01). In addition, the average ADC values of the two DWI sequences were negatively correlated with the type of lesions, decreasing with the malignancy of the lesions (r = -0.805 P < 0.01, r = -0.815 P < 0.01). CONCLUSION: Compared to SS-EPI-DWI, MUSE-DWI can significantly reduce distortion, artifacts, and fuzziness in MRI of uterine lesions, which is more conducive to lesion detection.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Relación Señal-Ruido , Neoplasias Uterinas , Útero , Humanos , Femenino , Imagen de Difusión por Resonancia Magnética/métodos , Persona de Mediana Edad , Adulto , Neoplasias Uterinas/diagnóstico por imagen , Imagen Eco-Planar/métodos , Útero/diagnóstico por imagen , Útero/patología , Variaciones Dependientes del Observador , Anciano , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interpretación de Imagen Asistida por Computador/métodos , Método Doble Ciego , Procesamiento de Imagen Asistido por Computador/métodos , Aumento de la Imagen/métodos
19.
Eur J Radiol ; 175: 111406, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38490129

RESUMEN

PURPOSE: To compare image quality, assess inter-reader variability, and evaluate the diagnostic efficacy of routine clinical lumbar spine sequences at 0.55T compared with those collected at 1.5/3T to assess common spine pathology. METHODS: 665 image series across 70 studies, collected at 0.55T and 1.5/3T, were assessed by two neuroradiology fellows for overall imaging quality (OIQ), artifacts, and accurate visualization of anatomical features (intervertebral discs, neural foramina, spinal cord, bone marrow, and conus / cauda equina nerve roots) using a 4-point Likert scale (1 = non-diagnostic to 4 = excellent). For the 0.55T scans, the most appropriate diagnosis(es) from a picklist of common spine pathologies was selected. The mean ± SD of all scores for all features for each sequence and reader at 0.55T and 1.5/3T were calculated. Paired t-tests (p ≤ 0.05) were used to compare ratings between field strengths. The inter-reader agreement was calculated using linear-weighted Cohen's Kappa coefficient (p ≤ 0.05). Unpaired VCG analysis for OIQ was additionally employed to represent differences between 0.55T and 1.5/3T (95 % CI). RESULTS: All sequences at 0.55T were rated as acceptable (≥2) for diagnostic use by both readers despite significantly lower scores for some compared to those at 1.5/3T. While there was low inter-reader agreement on individual scores, the agreement on the diagnosis was high, demonstrating the potential of this system for detecting routine spine pathology. CONCLUSIONS: Clinical lumbar spine imaging at 0.55T produces diagnostic-quality images demonstrating the feasibility of its use in diagnosing spinal pathology, including osteomyelitis/discitis, post-surgical changes with complications, and metastatic disease.


Asunto(s)
Vértebras Lumbares , Imagen por Resonancia Magnética , Enfermedades de la Columna Vertebral , Humanos , Vértebras Lumbares/diagnóstico por imagen , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados , Femenino , Persona de Mediana Edad , Adulto , Variaciones Dependientes del Observador , Artefactos , Sensibilidad y Especificidad , Anciano
20.
Ultrasound Q ; 40(2): 132-135, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38470608

RESUMEN

ABSTRACT: This study aimed to assess the detection rate of small (<10 mm) pancreas cyst and intrareader reliability for cyst size measurements on transabdominal ultrasonography (US). From 2020 to 2022, 194 pancreas cysts in 173 patients, incidentally detected on computed tomography or magnetic resonance imaging, were evaluated on US by 1 of 2 radiologists (readers 1 and 2). Intrareader agreements of cyst size measurements on US were assessed by intraclass correlation coefficient (ICC). Bland-Altman plot was used to visualize the differences between the first and second size measurements in each reader. In this study, readers 1 and 2 evaluated 86 cysts in 76 patients and 108 cysts in 97 patients, respectively. Most of the cysts (191 of 194) were located in the nontail portion of the pancreas. Overall detection rate of pancreas cysts by US was 92.3% (179 of 194). The mean size of measured 179 pancreas cysts was 4.7 ± 1.5 mm. The readers showed excellent intrareader agreements (ICC = 0.925 and 0.960) for cyst size measurements, except for the cysts with size ≤5 mm, where both readers showed good intrareader agreements (ICC = 0.848 and 0.873). The 95% limits of agreement of readers 1 and 2 were 13.8% and 14.9% of the mean, respectively. Therefore, transabdominal US could be a reliable follow-up imaging modality for small (<10 mm) nontail pancreas cysts incidentally detected on computed tomography or magnetic resonance imaging, especially for the cysts with size between 5 and 10 mm. Size changes of the pancreas cysts approximately less than 15% may be within the measurement error.


Asunto(s)
Páncreas , Quiste Pancreático , Ultrasonografía , Humanos , Quiste Pancreático/diagnóstico por imagen , Ultrasonografía/métodos , Femenino , Masculino , Reproducibilidad de los Resultados , Persona de Mediana Edad , Páncreas/diagnóstico por imagen , Anciano , Adulto , Tomografía Computarizada por Rayos X/métodos , Variaciones Dependientes del Observador , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Anciano de 80 o más Años
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA