Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Oral Dis ; 29(5): 2272-2276, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35467064

RESUMO

This study aimed to evaluate the effectiveness of oral amoxicillin/clavulanate (AMX-CL) for the prevention of bacteremia following dental extractions. The study group (AMX-CLG) comprised 40 adults requiring dental extractions under general anesthesia who were administered a prophylactic regimen of 1875/125 mg of AMX-CL orally 1-2 h prior to the surgery. Venous blood samples were collected from each patient at baseline and at 30 s and 15 min after dental extractions. Samples were inoculated into BACTEC Plus culture bottles and processed in the BACTEC 9240. Conventional microbiological techniques were used for subcultures and further identification of the isolated bacteria. The results for the AMX-CLG were compared with those of a control group (CG; no prophylaxis) and an amoxicillin group (AMXG; 2 g of amoxicillin orally), consisting of randomly selected patients from among those participating in two clinical trials that we have previously published. The prevalence of bacteremia in the CG, AMXG, and AMX-CLG was 97%, 50%, and 15%, respectively, at 30 s after completing the extractions, and 67%, 10%, and 4% at 15 min, respectively, after the last extraction. The prevalence of bacteremia in the AMXG and the AMX-CLG at 30 s and at 15 min after completing the extractions was significantly lower than that in the CG (p < 0.001 and p < 0.001, respectively; Fisher's exact test). The prevalence of bacteremia in the AMX-CLG at 30 s after completing the extractions was significantly lower than that in the AMXG (p < 0.001; Fisher's exact test). Based in the results of this preliminary study, oral AMX-CL could be an excellent option for preventing bacteremia secondary to dental procedures in patients at risk.


Assuntos
Bacteriemia , Extração Dentária , Adulto , Humanos , Extração Dentária/efeitos adversos , Amoxicilina/uso terapêutico , Combinação Amoxicilina e Clavulanato de Potássio/uso terapêutico , Bacteriemia/prevenção & controle , Bacteriemia/epidemiologia , Bactérias , Antibacterianos/uso terapêutico
2.
Respiration ; 92(4): 274-278, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27627819

RESUMO

BACKGROUND: Endoscopes represent the medical devices most commonly linked to health care-associated outbreaks and pseudo-outbreaks. Most of the recent outbreaks and pseudo-outbreaks have resulted from contaminated automated endoscope reprocessors (AER) or the use of damaged or malfunctioning bronchoscopes or contaminated equipment. OBJECTIVES: We investigated a pseudo-outbreak of Pseudomonas putida and Stenotrophomonas maltophilia recovered from bronchial washing (BW) specimens obtained during bronchoscopy in a bronchoscopy unit. METHODS: Samples were obtained from environmental surfaces in the endoscopy suite, bronchoscopes, and bronchoscopic dispensable material, and specimens of cleaning solutions, cleaning brushes, the AER, and the ultrasound system were sent for bacterial culture. Medical records were reviewed to identify possible infections after a bronchoscopy. RESULTS: P. putida and S. maltophilia were isolated from BW samples of 39 patients. The bronchoscopy models Olympus BF-1T160 and BF-160 were contaminated. Both bronchoscopes and other contaminated material (cleaning brushes, diluted cleaning solutions, and the sink) were isolated, but new cases continued to appear. The AER was recently installed, and new connections were used for the water lines and new tubes were connected to the AER. Initially, specimens were obtained from the external circuits and the internal walls of the AER. Finally, cultures were made from the filters on the water lines, and growth of P. putida and S. maltophilia was found. The investigation revealed that the BW specimens were contaminated because sterile saline was injected by means of the biopsy port of the bronchoscope and was recovered through the same channel by means of the proximal suction port. No patients developed clinical signs or symptoms of infection, but the positive cultures did lead to treatment of 21 patients. CONCLUSIONS: We described a pseudo-outbreak related to a contaminated bronchoscope because of inadequate installation of the AER for used new water lines and because the new tubes were connected to the AER. The antibacterial filters of the AER used tap water, and this may have contained low levels of microorganisms. No serious clinical complications derived from this pseudo-outbreak.


Assuntos
Líquido da Lavagem Broncoalveolar/microbiologia , Broncoscópios/microbiologia , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Contaminação de Equipamentos , Infecções por Bactérias Gram-Negativas/epidemiologia , Infecções por Pseudomonas/epidemiologia , Idoso , Broncoscopia , Infecção Hospitalar/diagnóstico , Erros de Diagnóstico , Feminino , Infecções por Bactérias Gram-Negativas/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Infecções por Pseudomonas/diagnóstico , Pseudomonas putida/isolamento & purificação , Espanha/epidemiologia , Stenotrophomonas maltophilia/isolamento & purificação