Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 11(3)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35160149

RESUMO

With the demographic evolution of the population, patients undergoing surgery today are older and have an increasing number of sometimes complex comorbidities. Cardiac implantable electronic devices (CIED) are also getting more and more complex with very sophisticated programming algorithms. It may be generally assumed that magnet application reverts pacing to an asynchronous mode in pacemakers and disables tachycardia detection/therapy in internal cardioverter-defibrillators. However, depending on device type, manufacturer and model, the response to magnet application may differ substantially. For these reasons, perioperative management of CIED patients is getting more and more challenging. With this review article we provide an overview of optimal perioperative management of CIED patients with a detailed description of CIED response to magnet application depending on manufacturer and device-type, which may help in providing a safe perioperative management plan for the CIED patient.

2.
J Am Heart Assoc ; 10(2): e018572, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33410337

RESUMO

Background Short ECG P-wave duration has recently been demonstrated to be associated with higher risk of atrial fibrillation (AF). The aim of this study was to assess the rate of AF recurrence after pulmonary vein isolation in patients with a short P wave, and to mechanistically elucidate the observation by computer modeling. Methods and Results A total of 282 consecutive patients undergoing a first single-pulmonary vein isolation procedure for paroxysmal or persistent AF were included. Computational models studied the effect of adenosine and sodium conductance on action potential duration and P-wave duration (PWD). About 16% of the patients had a PWD of 110 ms or shorter (median PWD 126 ms, interquartile range, 115 ms-138 ms; range, 71 ms-180 ms). At Cox regression, PWD was significantly associated with AF recurrence (P=0.012). Patients with a PWD <110 ms (hazard ratio [HR], 2.20; 95% CI, 1.24-3.88; P=0.007) and patients with a PWD ≥140 (HR, 1.87, 95% CI, 1.06-3.30; P=0.031) had a nearly 2-fold increase in risk with respect to the other group. In the computational model, adenosine yielded a significant reduction of action potential duration 90 (52%) and PWD (7%). An increased sodium conductance (up to 200%) was robustly accompanied by an increase in conduction velocity (26%), a reduction in action potential duration 90 (28%), and PWD (22%). Conclusions One out of 5 patients referred for pulmonary vein isolation has a short PWD which was associated with a higher rate of AF after the index procedure. Computer simulations suggest that shortening of atrial action potential duration leading to a faster atrial conduction may be the cause of this clinical observation.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Complicações Pós-Operatórias , Potenciais de Ação/efeitos dos fármacos , Potenciais de Ação/fisiologia , Adenosina/farmacologia , Antiarrítmicos/farmacologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Simulação por Computador , Feminino , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/cirurgia , Recidiva , Canais de Sódio/fisiologia
3.
Int J Cardiol ; 270: 136-142, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29929934

RESUMO

BACKGROUND: Unrecognized incomplete pulmonary vein isolation (PVI), as opposed to post-PVI pulmonary vein reconnection, may be responsible for clinical recurrences of atrial fibrillation (AF). To date, no data are available on the use of high-resolution mapping (HRM) during cryoballoon (CB) ablation for AF as the index procedure. The aims of this study were: - to assess the value of using a HRM system during CB ablation procedures in terms of ability in acutely detecting incomplete CB lesions; - to compare the 8-pole circular mapping catheter (CMC, Achieve) and the 64-pole mini-basket catheter (Orion) with respect to pulmonary vein (PV) signals detection at baseline and after CB ablation; - to characterize the extension of the lesion produced by CB ablation by means of high-density voltage mapping. METHODS: Consecutive patients with drug-resistant paroxysmal or early-persistent AF undergoing CB ablation as the index procedure, assisted by a HRM system, were retrospectively included in this study. RESULTS: A total of 33 patients (25 males; mean age: 59 ±â€¯18 years, 28 paroxysmal AF) were included. At baseline, CMC catheter revealed PV activity in 102 PVs (77%), while the Orion documented PV signals in all veins (100%). Failure of complete CB-PVI was more frequently revealed by atrial re-mapping with the Orion as compared to the Achieve catheter (24% vs 0%, p < 0.05). A repeat ablation was performed in 8 patients (24%). In 9% of cases, the Orion catheter detected far-field signals originating from the right atrium. Quantitative assessment of the created lesion revealed a significant reduction of the left atrial area having voltage >0.5 mV. A total of 29 patients (88%) remained free of symptomatic AF during a mean follow-up of 13.2 ±â€¯3.7 months. CONCLUSION: Atrial re-mapping after CB ablation by means of a HRM system improves the detection of areas of incomplete ablation, characterizes the extension of the cryo-ablated tissue and can identify abolishment of potential non-PVI related sources of AF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/normas , Criocirurgia/normas , Ecocardiografia Transesofagiana/normas , Adulto , Idoso , Ablação por Cateter/métodos , Criocirurgia/métodos , Ecocardiografia/métodos , Ecocardiografia/normas , Ecocardiografia Transesofagiana/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia
4.
Europace ; 20(11): 1827-1832, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29672695

RESUMO

Aims: Phrenic nerve palsy (PNP) after mechanical transvenous lead extraction (TLE) was recently described for the first time. We aimed to analyse our TLE database for the presence of PNP. Methods and results: All consecutive patients referred to our institution were included in this study. Every available post-procedural chest X-ray was compared to the routinely performed pre-procedural radiographs. A newly elevated hemidiaphragm ipsilateral to TLE was considered indicative of PNP. Altogether 255 TLE procedures with extraction of 364 leads were performed. Most common TLE indication was lead malfunction (63%). Complete radiographic success rate was 97.3% with an in-hospital procedure-related major complication rate of 2.4%, including one intra-procedural death (0.4%). We identified five cases with PNP (2%), all occurring after laser-assisted TLE. Clinical presentation varied from subtle and aspecific chest pain/discomfort to severe and acute dyspnoea, with time to diagnosis varying from immediate to several weeks after the procedure. In 80% of cases, the explanted lead was a defibrillator electrode and the median lead dwelling time was 70.2 months (29.3; 1084.9). In four cases, the extraction was performed using high-energy laser (pulse repetition rate 80 Hz). Conclusion: The present study reports the incidence of PNP after laser-assisted TLE. We postulate that the thermal energy generated by laser is not dissipated quickly enough in occluded or heavily calcified lesions, injuring the ipsilateral phrenic nerve. Our findings advise to carefully consider to increase pulse repetition rate at the subclavian level. Larger, possibly prospective studies are needed to evaluate the real incidence through systematic radiological assessment after TLE.


Assuntos
Remoção de Dispositivo , Diafragma/inervação , Terapia a Laser/efeitos adversos , Lasers , Traumatismos dos Nervos Periféricos , Nervo Frênico/lesões , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Desfibriladores Implantáveis , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Incidência , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/epidemiologia , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Traumatismos dos Nervos Periféricos/diagnóstico , Traumatismos dos Nervos Periféricos/epidemiologia , Traumatismos dos Nervos Periféricos/etiologia , Radiografia Torácica/métodos , Risco Ajustado , Suíça
5.
Cardiol J ; 25(6): 714-721, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29341061

RESUMO

BACKGROUND: Hemodynamically irrelevant pericardial effusion (PeEf) is a predictor of adverse outcome in heart failure patients. The clinical relevance of a PeEf unrelated to surgery in heart transplant patients remains unknown. This study assesses the prognostic value of PeEf occurring later than 1 year after transplantation. METHODS: All patients undergoing heart transplantation in Zurich between 1989 and 2012 were screened. Cox proportional hazard models were used to analyze mortality (primary) and hospitalization (secondary endpoint). PeEf time points were compared to baseline for rejection, immunosuppressants, tumors, inflam-mation, heart failure, kidney function, hemodynamic, and echocardiographic parameters. RESULTS: Of 152 patients (mean age 48.3 ± 11.9), 25 developed PeEf. Median follow-up period was 11.9 (IQR 5.8-17) years. The number of deaths was 6 in the PeEf group and 46 in the non-PeEf group. The occurrence of PeEf was associated with a 2.5-fold increased risk of death (HR 2.49, 95% CI 1.02-6.13, p = 0.046) and hospitalization (HR 2.53, 95% CI 1.57-4.1, p = 0.0002). CONCLUSIONS: This study reveals that the finding of hemodynamically irrelevant PeEf in heart trans-plant patients is a predictor of adverse outcome, suggesting that a careful clinical assessment is war-ranted in heart transplant patients exhibiting small PeEf.


Assuntos
Previsões , Insuficiência Cardíaca/cirurgia , Transplante de Coração/mortalidade , Hemodinâmica/fisiologia , Derrame Pericárdico/mortalidade , Transplantados , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/etiologia , Estudos Retrospectivos , Suíça/epidemiologia
6.
World J Cardiol ; 8(6): 375-8, 2016 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-27354895

RESUMO

A 78-year-old asymptomatic woman was referred to our clinic for a second opinion regarding indication for mitral valve surgery. An echocardiogram showed a moderate mitral stenosis with a concomitant severe regurgitation. The most striking feature, however, was a giant left atrium with a parasternal anteroposterior diameter of 79 mm and a left atrial volume index of 364 mL/m². There are various echocardiographic definitions of a giant left atrium, which are mainly based on measurements of the anteroposterior diameter of the left atrium using M-mode in the parasternal long axis view. Since the commonly accepted method for echocardiographic evaluation of left atrial size is left atrial volume index, we propose a cut-off value of 140 mL/m(2) for the definition of a "giant left atrium".

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA