1.
Magn Reson Med ; 87(4): 1938-1951, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34904726

RESUMO

PURPOSE: Restriction spectrum imaging (RSI) decomposes the diffusion-weighted MRI signal into separate components of known apparent diffusion coefficients (ADCs). The number of diffusion components and optimal ADCs for RSI are organ-specific and determined empirically. The purpose of this work was to determine the RSI model for breast tissues. METHODS: The diffusion-weighted MRI signal was described using a linear combination of multiple exponential components. A set of ADC values was estimated to fit voxels in cancer and control ROIs. Later, the signal contributions of each diffusion component were estimated using these fixed ADC values. Relative-fitting residuals and Bayesian information criterion were assessed. Contrast-to-noise ratio between cancer and fibroglandular tissue in RSI-derived signal contribution maps was compared to DCE imaging. RESULTS: A total of 74 women with breast cancer were scanned at 3.0 Tesla MRI. The fitting residuals of conventional ADC and Bayesian information criterion suggest that a 3-component model improves the characterization of the diffusion signal over a biexponential model. Estimated ADCs of triexponential model were D1,3 = 0, D2,3 = 1.5 × 10-3 , and D3,3 = 10.8 × 10-3 mm2 /s. The RSI-derived signal contributions of the slower diffusion components were larger in tumors than in fibroglandular tissues. Further, the contrast-to-noise and specificity at 80% sensitivity of DCE and a subset of RSI-derived maps were equivalent. CONCLUSION: Breast diffusion-weighted MRI signal was best described using a triexponential model. Tumor conspicuity in breast RSI model is comparable to that of DCE without the use of exogenous contrast. These data may be used as differential features between healthy and malignant breast tissues.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Teorema de Bayes , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade
2.
NMR Biomed ; 34(7): e4508, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33738878

RESUMO

Diffusion-weighted MRI (DWI) is an important tool for oncology research, with great clinical potential for the classification and monitoring of breast lesions. The utility of parameters derived from DWI, however, is influenced by specific analysis choices. The purpose of this study was to critically evaluate repeatability and curve-fitting performance of common DWI signal representations, for a prospective cohort of patients with benign breast lesions. Twenty informed, consented patients with confirmed benign breast lesions underwent repeated DWI (3 T) using: sagittal single-shot spin-echo echo planar imaging, bipolar encoding, TR/TE: 11,600/86 ms, FOV: 180 x 180 mm, matrix: 90 x 90, slices: 60 x 2.5 mm, iPAT: GRAPPA 2, fat suppression, and 13 b-values: 0-700 s/mm2 . A phase-reversed scan (b = 0 s/mm2 ) was acquired for distortion correction. Voxel-wise repeat-measures coefficients of variation (CoVs) were derived for monoexponential (apparent diffusion coefficient [ADC]), biexponential (intravoxel incoherent motion: f, D, D*) and stretched exponential (α, DDC) across the parameter histograms for lesion regions of interest (ROIs). Goodness-of-fit for each representation was assessed by Bayesian information criterion. The volume of interest (VOI) definition was repeatable (CoV 13.9%). Within lesions, and across both visits and the cohort, there was no dominant best-fit model, with all representations giving the best fit for a fraction of the voxels. Diffusivity measures from the signal representations (ADC, D, DDC) all showed good repeatability (CoV < 10%), whereas parameters associated with pseudodiffusion (f, D*) performed poorly (CoV > 50%). The stretching exponent α was repeatable (CoV < 12%). This pattern of repeatability was consistent over the central part of the parameter percentiles. Assumptions often made in diffusion studies about analysis choices will influence the detectability of changes, potentially obscuring useful information. No single signal representation prevails within or across lesions, or across repeated visits; parameter robustness is therefore a critical consideration. Our results suggest that stretched exponential representation is more repeatable than biexponential, with pseudodiffusion parameters unlikely to provide clinically useful biomarkers.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/estatística & dados numéricos , Adulto , Teorema de Bayes , Biópsia com Agulha de Grande Calibre , Doenças Mamárias/patologia , Neoplasias da Mama/patologia , Estudos de Coortes , Feminino , Fibroadenoma/patologia , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
3.
Clin Cancer Res ; 27(4): 1094-1104, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33148675

RESUMO

PURPOSE: Diffusion-weighted MRI (DW-MRI) is a contrast-free modality that has demonstrated ability to discriminate between predefined benign and malignant breast lesions. However, how well DW-MRI discriminates cancer from all other breast tissue voxels in a clinical setting is unknown. Here we explore the voxelwise ability to distinguish cancer from healthy breast tissue using signal contributions from the newly developed three-component multi-b-value DW-MRI model. EXPERIMENTAL DESIGN: Patients with pathology-proven breast cancer from two datasets (n = 81 and n = 25) underwent multi-b-value DW-MRI. The three-component signal contributions C 1 and C 2 and their product, C 1 C 2, and signal fractions F 1, F 2, and F 1 F 2 were compared with the image defined on maximum b-value (DWI max), conventional apparent diffusion coefficient (ADC), and apparent diffusion kurtosis (K app). The ability to discriminate between cancer and healthy breast tissue was assessed by the false-positive rate given a sensitivity of 80% (FPR80) and ROC AUC. RESULTS: Mean FPR80 for both datasets was 0.016 [95% confidence interval (CI), 0.008-0.024] for C 1 C 2, 0.136 (95% CI, 0.092-0.180) for C 1, 0.068 (95% CI, 0.049-0.087) for C 2, 0.462 (95% CI, 0.425-0.499) for F 1 F 2, 0.832 (95% CI, 0.797-0.868) for F 1, 0.176 (95% CI, 0.150-0.203) for F 2, 0.159 (95% CI, 0.114-0.204) for DWI max, 0.731 (95% CI, 0.692-0.770) for ADC, and 0.684 (95% CI, 0.660-0.709) for K app. Mean ROC AUC for C 1 C 2 was 0.984 (95% CI, 0.977-0.991). CONCLUSIONS: The C 1 C 2 parameter of the three-component model yields a clinically useful discrimination between cancer and healthy breast tissue, superior to other DW-MRI methods and obliviating predefining lesions. This novel DW-MRI method may serve as noncontrast alternative to standard-of-care dynamic contrast-enhanced MRI.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/patologia , Neoplasias da Mama/patologia , Conjuntos de Dados como Assunto , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Adulto Jovem
5.
MAGMA ; 33(2): 317-328, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31562584

RESUMO

OBJECTIVES: To investigate the reliability of simultaneous positron emission tomography and magnetic resonance imaging (PET/MRI)-derived biomarkers using semi-automated Gaussian mixture model (GMM) segmentation on PET images, against conventional manual tumor segmentation on dynamic contrast-enhanced (DCE) images. MATERIALS AND METHODS: Twenty-four breast cancer patients underwent PET/MRI (following 18F-fluorodeoxyglucose (18F-FDG) injection) at baseline and during neoadjuvant treatment, yielding 53 data sets (24 untreated, 29 treated). Two-dimensional tumor segmentation was performed manually on DCE-MRI images (manual DCE) and using GMM with corresponding PET images (GMM-PET). Tumor area and mean apparent diffusion coefficient (ADC) derived from both segmentation methods were compared, and spatial overlap between the segmentations was assessed with Dice similarity coefficient and center-of-gravity displacement. RESULTS: No significant differences were observed between mean ADC and tumor area derived from manual DCE segmentation and GMM-PET. There were strong positive correlations for tumor area and ADC derived from manual DCE and GMM-PET for untreated and treated lesions. The mean Dice score for GMM-PET was 0.770 and 0.649 for untreated and treated lesions, respectively. DISCUSSION: Using PET/MRI, tumor area and mean ADC value estimated with a GMM-PET can replicate manual DCE tumor definition from MRI for monitoring neoadjuvant treatment response in breast cancer.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Neoplasias da Mama/tratamento farmacológico , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Imagem Multimodal , Distribuição Normal , Reconhecimento Automatizado de Padrão , Estudos Prospectivos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
6.
J Magn Reson Imaging ; 47(5): 1205-1216, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29044896

RESUMO

BACKGROUND: Diffusion-weighted MRI (DWI) is currently one of the fastest developing MRI-based techniques in oncology. Histogram properties from model fitting of DWI are useful features for differentiation of lesions, and classification can potentially be improved by machine learning. PURPOSE: To evaluate classification of malignant and benign tumors and breast cancer subtypes using support vector machine (SVM). STUDY TYPE: Prospective. SUBJECTS: Fifty-one patients with benign (n = 23) and malignant (n = 28) breast tumors (26 ER+, whereof six were HER2+). FIELD STRENGTH/SEQUENCE: Patients were imaged with DW-MRI (3T) using twice refocused spin-echo echo-planar imaging with echo time / repetition time (TR/TE) = 9000/86 msec, 90 × 90 matrix size, 2 × 2 mm in-plane resolution, 2.5 mm slice thickness, and 13 b-values. ASSESSMENT: Apparent diffusion coefficient (ADC), relative enhanced diffusivity (RED), and the intravoxel incoherent motion (IVIM) parameters diffusivity (D), pseudo-diffusivity (D*), and perfusion fraction (f) were calculated. The histogram properties (median, mean, standard deviation, skewness, kurtosis) were used as features in SVM (10-fold cross-validation) for differentiation of lesions and subtyping. STATISTICAL TESTS: Accuracies of the SVM classifications were calculated to find the combination of features with highest prediction accuracy. Mann-Whitney tests were performed for univariate comparisons. RESULTS: For benign versus malignant tumors, univariate analysis found 11 histogram properties to be significant differentiators. Using SVM, the highest accuracy (0.96) was achieved from a single feature (mean of RED), or from three feature combinations of IVIM or ADC. Combining features from all models gave perfect classification. No single feature predicted HER2 status of ER + tumors (univariate or SVM), although high accuracy (0.90) was achieved with SVM combining several features. Importantly, these features had to include higher-order statistics (kurtosis and skewness), indicating the importance to account for heterogeneity. DATA CONCLUSION: Our findings suggest that SVM, using features from a combination of diffusion models, improves prediction accuracy for differentiation of benign versus malignant breast tumors, and may further assist in subtyping of breast cancer. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1205-1216.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos , Máquina de Vetores de Suporte , Adulto , Idoso , Algoritmos , Mama/diagnóstico por imagem , Difusão , Imagem Ecoplanar , Receptor alfa de Estrogênio/metabolismo , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Pessoa de Meia-Idade , Movimento (Física) , Estudos Prospectivos , Receptor ErbB-2/metabolismo , Reprodutibilidade dos Testes
7.
Radiology ; 281(2): 373-381, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27128662

RESUMO

Purpose To evaluate the relative change of the apparent diffusion coefficient (ADC) at low- and medium-b-value regimens as a surrogate marker of microcirculation, to study its correlation with dynamic contrast agent-enhanced (DCE) magnetic resonance (MR) imaging-derived parameters, and to assess its potential for differentiation between malignant and benign breast tumors. Materials and Methods Ethics approval and informed consent were obtained. From May 2013 to June 2015, 61 patients diagnosed with either malignant or benign breast tumors were prospectively recruited. All patients were scanned with a 3-T MR imager, including diffusion-weighted imaging (DWI) and DCE MR imaging. Parametric analysis of DWI and DCE MR imaging was performed, including a proposed marker, relative enhanced diffusivity (RED). Spearman correlation was calculated between DCE MR imaging and DWI parameters, and the potential of the different DWI-derived parameters for differentiation between malignant and benign breast tumors was analyzed by dividing the sample into equally sized training and test sets. Optimal cut-off values were determined with receiver operating characteristic curve analysis in the training set, which were then used to evaluate the independent test set. Results RED had a Spearman rank correlation of 0.61 with the initial area under the curve calculated from DCE MR imaging. Furthermore, RED differentiated cancers from benign tumors with an overall accuracy of 90% (27 of 30) on the test set with 88.2% (15 of 17) sensitivity and 92.3% (12 of 13) specificity. Conclusion This study presents promising results introducing a simplified approach to assess results from a DWI protocol sensitive to the intravoxel incoherent motion effect by using only three b values. This approach could potentially aid in the differentiation, characterization, and monitoring of breast pathologies. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Microvasos/patologia , Adulto , Idoso , Biomarcadores Tumorais/análise , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Meglumina , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos , Sensibilidade e Especificidade
8.
J Magn Reson Imaging ; 43(5): 1111-21, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26494124

RESUMO

BACKGROUND: To compare "standard" diffusion weighted imaging, and diffusion tensor imaging (DTI) of 2(nd) and 4(th) -order for the differentiation of malignant and benign breast lesions. METHODS: Seventy-one patients were imaged at 3 Tesla with a 16-channel breast coil. A diffusion weighted MRI sequence including b = 0 and b = 700 in 30 directions was obtained for all patients. The image data were fitted to three different diffusion models: isotropic model - apparent diffusion coefficient (ADC), 2(nd) -order tensor model (the standard model used for DTI) and a 4(th) -order tensor model, with increased degrees of freedom to describe anisotropy. The ability of the fitted parameters in the different models to differentiate between malignant and benign tumors was analyzed. RESULTS: Seventy-two breast lesions were analyzed, out of which 38 corresponded to malignant and 34 to benign tumors. ADC (using any model) presented the highest discriminative ability of malignant from benign tumors with a receiver operating characteristic area under the curve (AUC) of 0.968, and sensitivity and specificity of 94.1% and 94.7% respectively for a 1.33 × 10(-3) mm(2) /s cutoff. Anisotropy measurements presented high statistical significance between malignant and benign tumors (P < 0.001), but with lower discriminative ability of malignant from benign tumors than ADC (AUC of 0.896 and 0.897 for fractional anisotropy and generalized anisotropy respectively). Statistical significant difference was found between generalized anisotropy and fractional anisotropy for cancers (P < 0.001) but not for benign lesions (P = 0.87). CONCLUSION: While anisotropy parameters have the potential to provide additional value for breast applications as demonstrated in this study, ADC exhibited the highest differentiation power between malignant and benign breast tumors.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mama/diagnóstico por imagem , Mama/patologia , Imagem de Difusão por Ressonância Magnética , Adolescente , Adulto , Anisotropia , Área Sob a Curva , Imagem de Tensor de Difusão , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Modelos Estatísticos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
9.
Magn Reson Med ; 74(4): 1138-44, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25323982

RESUMO

PURPOSE: To evaluate the performance of an advanced method for correction of inhomogeneous static magnetic field induced distortion in echo-planar imaging (EPI), applied to diffusion-weighted MRI (DWI) of the breast. METHODS: An algorithm for distortion correction based on the symmetry of the distortion induced by static field inhomogeneity when the phase encoding polarity is reversed was evaluated in 36 data sets of patients who received an MRI examination that included DWI (b = 0 and 700 s/mm(2) ) and an extra b = 0 s/mm(2) sequence with opposite phase encoding polarity. The decrease of the L2 -square norm after correction between opposed phase encoding b = 0 images was calculated. Mattes mutual information between b = 0 images and fat-suppressed T2 -weighted images was calculated before and after correction. RESULTS: The L2 -square norm between different phase encoding polarities for b = 0 images was reduced 94.3% on average after distortion correction. Furthermore, Mattes mutual information between b = 0 images and fat-suppressed T2 -weighted images increased significantly after correction for all cases (P < 0.001). CONCLUSION: Geometric distortion correction in DWI of the breast results in higher similarity of DWI to anatomical non-EPI T2 -weighted images and would potentially allow for a more reliable lesion segmentation mapping among different MRI modalities.


Assuntos
Neoplasias da Mama/patologia , Mama/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA