RESUMO
PURPOSE: To identify key dosimetric parameters that have close associations with tumor treatment response and body weight change in SFRT treatments with a large range of spatial-fractionation scale at dose rates of several Gy/min. METHODS: Six study arms using uniform tumor radiation, half-tumor radiation, 2mm beam array radiation, 0.3mm minibeam radiation, and an untreated arm were used. All treatments were delivered on a 320kV x-ray irradiator. Forty-two female Fischer 344 rats with fibrosarcoma tumor allografts were used. Dosimetric parameters studied are peak dose and width, valley dose and width, peak-to-valley-dose-ratio (PVDR), volumetric average dose, percentage volume directly irradiated, and tumor- and normal-tissue EUD. Animal survival, tumor volume change, and body weight change (indicative of treatment toxicity) are tested for association with the dosimetric parameters using linear regression and Cox Proportional Hazards models. RESULTS: The dosimetric parameters most closely associated with tumor response are tumor EUD (R2 = 0.7923, F-stat = 15.26*; z-test = -4.07***), valley (minimum) dose (R2 = 0.7636, F-stat = 12.92*; z-test = -4.338***), and percentage tumor directly irradiated (R2 = 0.7153, F-stat = 10.05*; z-test = -3.837***) per the linear regression and Cox Proportional Hazards models, respectively. Tumor response is linearly proportional to valley (minimum) doses and tumor EUD. Average dose (R2 = 0.2745, F-stat = 1.514 (no sig.); z-test = -2.811**) and peak dose (R2 = 0.04472, F-stat = 0.6874 (not sig.); z-test = -0.786 (not sig.)) show the weakest associations to tumor response. Only the uniform radiation arm did not gain body weight post-radiation, indicative of treatment toxicity; however, body weight change in general shows weak association with all dosimetric parameters except for valley (minimum) dose (R2 = 0.3814, F-stat = 13.56**), valley width (R2 = 0.2853, F-stat = 8.783**), and peak width (R2 = 0.2759, F-stat = 8.382**). CONCLUSIONS: For a single-fraction SFRT at conventional dose rates, valley, not peak, dose is closely associated with tumor treatment response and thus should be used for treatment prescription. Tumor EUD, valley (minimum) dose, and percentage tumor directly irradiated are the top three dosimetric parameters that exhibited close associations with tumor response.
Assuntos
Fracionamento da Dose de Radiação , Fibrossarcoma/radioterapia , Animais , Peso Corporal/efeitos da radiação , Modelos Animais de Doenças , Feminino , Fibrossarcoma/patologia , Radiometria , Ratos , Ratos Endogâmicos F344 , Resultado do Tratamento , Carga Tumoral/efeitos da radiaçãoRESUMO
BACKGROUND: The electronic cigarette industry is growing, with youth using e-cigarettes at higher rates than they are using cigarettes, and retail and online sales projected to reach $10 billion in 2017. Minimal regulation of the production and marketing of e-cigarettes exists to date, which has allowed companies to promote unsupported claims. We assessed the shipping, product features and packaging of a wide variety of e-cigarettes purchased online by adults and youth. METHODS: The most popular internet e-cigarette vendors were identified from a larger study of internet tobacco vendors. Between August 2013 and June 2014, adults made 56 purchase attempts from online vendors, and youth made 98 attempts. Packages received were assessed for exterior and internal packaging features, including product information, health warnings and additional materials. RESULTS: We analysed a total of 125 orders featuring 86 unique brands of e-cigarettes. The contents were rarely indicated on package exteriors. Product information came with just 60% of orders and just 38.4% included an instruction manual. Only 44.6% of products included a health warning, and some had unsupported claims, such as lack of secondhand smoke exposure. Additionally, some products were leaking e-liquid and battery fluid on arrival. CONCLUSIONS: A large variety of e-cigarette products are manufactured and marketed to consumers. Many products do not include instructions for use, and unsupported claims are being presented to consumers. Effective federal regulation of the manufacturing, packaging, product information and health claims surrounding e-cigarettes is necessary to ensure consumers are presented with accurate e-cigarette use information.