Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Heart Rhythm ; 19(7): 1084-1096, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35341994

RESUMO

BACKGROUND: Electrical stimulation during ventricular tachycardia resulting in tachycardia termination without global propagation (TWGP) is a well-recognized phenomenon. However, there is a paucity of literature showing a similar phenomenon in atrial arrhythmias. OBJECTIVE: The purpose of the study was to evaluate the significance of TWGP in atrial arrhythmias. METHODS: Electrophysiological studies performed from 2000 to 2019 at Methodist Hospital, Indiana University were reviewed retrospectively. Thirty-four patients were identified in whom stimulation during atrial tachycardia/flutter resulted in TWGP. RESULTS: Of the 34 patients, 12 (29%) had cavotricuspid isthmus (CTI)-dependent atrial flutter and 22 (71%) had other atrial arrhythmias during which TWGP was seen. Mean age of the population was 53 ± 13 years; and 68% were male. Previous catheter ablation for atrial fibrillation, atrial flutter, or other atrial tachyarrhythmias had been performed in 70.5%, and 44% previously had undergone cardiac surgery involving the atria. Congenital heart disease was present in 20.5%; 3 patients were status post lung transplant. Mean cycle length of atrial arrhythmia in which TWGP was seen was 317 ± 76 ms. The sites at which TWGP was seen reproducibly were highly specific for successful termination of the arrhythmias with radiofrequency energy. The arrhythmia circuits were 12 CTI-dependent atrial flutter, 11 left atrial macroreentrant atrial tachycardia (MRAT), 1 involving both left and right atria, and 8 were other right atrial MRAT. CONCLUSION: Termination of macroreentrant atrial arrhythmias by pacing stimuli without global propagation identifies a narrow diastolic isthmus at which catheter ablation is highly effective.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Taquicardia Supraventricular , Adulto , Idoso , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia , Taquicardia Supraventricular/cirurgia
2.
J Interv Card Electrophysiol ; 62(3): 531-538, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33415707

RESUMO

PURPOSE: Catheter ablation is considered the mainstay treatment for drug-refractory atrial fibrillation (AF). The aims of our study were to compare the efficacy and safety of the most two currently approved approaches (point-by-point radiofrequency ablation (RFA), either with contact force (CF) or without contact force (nCF) catheters, and cryoballoon ablation (CBA)) in the Veterans Healthcare System. METHODS: We performed a retrospective study of patients who underwent ablation for treatment of AF at the veterans affairs healthcare system between 2013 and 2018. Only the first reported ablation procedure was included. RESULTS: We included 956 patients in the study (97.4% males, 91.5% Caucasians, 67% paroxysmal AF), with 682 patients in RFA-nCF, 139 in RFA-CF, and 135 in CBA. Thirty-day complication rates were comparable between the three groups with the exception of higher incidence of phrenic nerve injury in CBA group when compared to RFA-nCF (2.2% vs 0.0%, p < 0.01). Long-term recurrence rate of AF was significantly lower in the CBA group when compared to RFA-nCF (33.3% vs 47.7%, adjusted HR 0.60, 95% CI 0.44-0.83, p < 0.01). On the other hand, it was similar between RFA-CF and RFA-nCF groups (43.9% vs 47.7%, adjusted HR 1.01, 95% CI 0.76-1.33, p 0.97). After stratifying patients based on AF type, these findings were only present in patients with paroxysmal AF. CONCLUSION: CBA for paroxysmal AF, in male dominant patients' population, was associated with lower incidence of AF recurrence rate while having a comparable safety profile to RFA independent of the use of CF catheters.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Ablação por Radiofrequência , Veteranos , Fibrilação Atrial/cirurgia , Atenção à Saúde , Feminino , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
3.
Am J Cardiol ; 125(2): 282-288, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31757354

RESUMO

Evidence linking cocaine to the risk of pulmonary hypertension (PH) is limited and inconsistent. We examined whether cocaine use, in the absence of other known causes of PH, was associated with elevated systolic pulmonary artery pressure (sPAP) and increased probability of PH. We compared patients with documented cocaine use to a randomly selected age, sex, and race-matched control group without history of cocaine use. All participants had no known causes of PH and underwent echocardiography for noninvasive estimation of sPAP. We used routinely reported echocardiographic parameters and contemporary guidelines to grade the probability of PH. In 88 patients with documented cocaine use (mean age ± standard deviation 51.7 ± 9.5 years), 33% were women and 89% were of Black race. The commonest route of cocaine use was smoking (74%). Cocaine users compared with the control group had significantly higher sPAP (mean ± standard deviation, 30.1 ± 13.1 vs 22.0 ± 9.8 mm Hg, p <0.001) and greater likelihood of PH (25% vs 10%, p = 0.012). In multivariable analyses adjusted for potential confounders including left ventricular diastolic dysfunction, cocaine use conferred a fivefold greater odds of echocardiographic PH (p = 0.006). Additionally, a stepwise increase in the likelihood of PH was noted across cocaine users with negative or no drug screen on the day of echocardiography to cocaine users with a positive drug screen (multivariable p for trend = 0.008). In conclusion, cocaine use was associated with a higher sPAP and an increased likelihood of echocardiographic PH with a probable acute-on-chronic effect.


Assuntos
Transtornos Relacionados ao Uso de Cocaína/complicações , Cocaína/efeitos adversos , Ecocardiografia Doppler/métodos , Ventrículos do Coração/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Artéria Pulmonar/diagnóstico por imagem , Pressão Propulsora Pulmonar/efeitos dos fármacos , Cateterismo Cardíaco , Inibidores da Captação de Dopamina/efeitos adversos , Feminino , Seguimentos , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/fisiopatologia , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sístole
4.
EuroIntervention ; 13(14): 1680-1687, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-28606887

RESUMO

AIMS: Intracoronary adenosine (ICA) yields similar fractional flow reserve (FFR) results to the "gold standard" of intravenous adenosine (IVA). Whether they have similar prognostic significance is unknown. We therefore sought to study the prognostic value of the route of adenosine administration for the measurement of FFR in deferred coronary lesions in a large, real-world cohort. METHODS AND RESULTS: Five hundred and seventy-six patients with 787 lesions in whom PCI was deferred based on FFR >0.75 were studied. The primary outcome was the first major adverse cardiovascular event (MACE; defined as death, myocardial infarction [MI], or target vessel revascularisation [TVR]), and the secondary outcome was a composite of MI and target vessel failure (TVF). FFR was measured with ICA in 426 lesions and IVA in 361 lesions. Median follow-up duration was 3.2 years (interquartile range: 1.7- 4.6). Propensity-matched cohorts of ICA and IVA were well matched for baseline clinical, angiographic and haemodynamic characteristics. In the propensity-matched cohort, MACE occurred in 23.5% of the ICA group and in 22.3% of the IVA group (p=0.29). On multivariate analysis, acute coronary syndrome, FFR and prior MI/revascularisation were independent predictors of MACE and MI/TVF. The route of adenosine administration was not predictive of MACE or MI/TVF. CONCLUSIONS: ICA and IVA yield similar FFR values and show comparable long-term prognostic utility in a deferred population. These findings provide confirmation that non-ischaemic FFR using a simpler ICA protocol provides prognostic data similar to the gold standard IVA.


Assuntos
Adenosina/administração & dosagem , Reserva Fracionada de Fluxo Miocárdico , Administração Intravenosa , Idoso , Angiografia Coronária , Feminino , Hemodinâmica , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA