Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 15(14): 833-843, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37584364

RESUMO

Aim: Aur0101 is a cytotoxic and small-molecule microtubule depolymerizing agent, and is the payload conjugated to antibody-drug conjugate PYX-201. Developing and validating a sensitive bioanalytical method to quantitate Aur0101 was novel and crucial in preclinical PYX-201 studies. Materials & methods: Reference standard Aur0101 and its stable isotope labelled internal standard Aur0101-d8 were used in this LC-MS/MS method. Results: This sensitive assay was validated at a lower limit of quantitation of 15 pg/ml and successfully applied to support preclinical rat and monkey toxicology studies. Preclinical plasma toxicokinetic parameters were presented. Conclusion: A sensitive and robust LC-MS/MS assay was validated for Aur0101 in rat and monkey plasma.


Assuntos
Antineoplásicos , Imunoconjugados , Ratos , Animais , Cromatografia Líquida/métodos , Haplorrinos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes
2.
Artigo em Inglês | MEDLINE | ID: mdl-37579604

RESUMO

A hybrid immunoaffinity LC-MS/MS assay was developed and validated for the quantitation of total antibody (TAb) from an antibody drug conjugate (ADC) PYX-201 in human plasma. PYX-201 was proteolyzed using trypsin, and a characteristic peptide fragment PYX-201 P1 with ten amino acids IPPTFGQGTK from the complementarity-determining regions (CDRs) was used as a surrogate for the quantitation of the TAb from PYX-201. Stable isotope labelled (SIL) peptide I(13C6, 15N)PPTFG(13C9, 15N)QGTK was used as the internal standard (IS). We performed chromatographic analysis using a Waters Acquity BEH Phenyl column (2.1 mm × 50 mm, 1.7 µm). Quantification of PYX-201 TAb was carried out on a Sciex triple quadrupole mass spectrometer API 6500 using multiple reaction monitoring (MRM) mode with positive electrospray ionization. To validate PYX-201 TAb, a concentration range of 0.0500 µg/mL to 20.0 µg/mL was used, yielding a correlation coefficient (r) of ≥ 0.9947. For intra-assay measurements, the percent relative error (%RE) ranged from -23.2% to 1.0%, with a coefficient of variation (%CV) of ≤ 14.2%. In terms of inter-assay measurements, the %RE was between -10.5% and -5.7%, with a %CV of ≤ 12.7%. The average recovery of the analyte was determined to be 81.4%, while the average recovery of the internal standard (IS) was 97.2%. Furthermore, PYX-201 TAb demonstrated stability in human plasma and human whole blood under various tested conditions. This assay has been successfully applied to human sample analysis to support a clinical study.


Assuntos
Fragmentos de Peptídeos , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes
3.
Artigo em Inglês | MEDLINE | ID: mdl-37352642

RESUMO

PYX-201 is an investigational antibody drug conjugate (ADC) with an engineered, fully human IgG1 antibody, a cleavable chemical linker, and a toxin (Aur0101) with an average drug-antibody ratio (DAR) of âˆ¼ 4. A sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and fully validated to determine the presence in human plasma, of free payload Aur0101 from PYX-201 to assess drug safety and efficacy. Aur0101 and its deuterated internal standard (IS), Aur0101_d8, were extracted from 25 µL of human plasma using a solid liquid extraction (SLE) method. Chromatographic analysis was carried out on a Waters Acquity UPLC BEH C18 (2.1 mm × 50 mm, 1.7 µm, 130 A) column. Quantitation of free Aur0101 was conducted on a Sciex triple quadrupole mass spectrometer API 6500 + using multiple reaction monitoring (MRM) mode via positive electrospray ionization. The calibration curve was linear over the concentration range of 25.0 to 12,500 pg/mL with correlation coefficient, r2 ≥ 0.9988. The intra-assay %RE was between -4.3% to 14.3% with % CV was ≤ 6.2%. The inter-assay %RE was between -0.2% to 9.5% with % CV was ≤ 6.1%. The average analyte recovery was 89.7% and the average IS recovery was 88.7%. Aur0101 was found to be stable in human plasma and human whole blood under various tested conditions with and without the presence of PYX-201. To our knowledge, this is the first published fully validated assay for free, unconjugated Aur0101 in any matrix, from any species. This assay has been successfully applied to clinical sample analysis to support clinical studies.


Assuntos
Imunoconjugados , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray
4.
J Pharm Biomed Anal ; 233: 115452, 2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37167766

RESUMO

PYX-201 is an investigative ADC oncology drug composed of a monoclonal human immunoglobulin G (IgG) antibody targeting the extra domain B splice variant of fibronectin (EDB + FN) conjugated to an auristatin payload through a cleavable linker. Effective measurement of PYX-201 tAb is the key to ADC drug PYX-201 preclinical pharmacokinetics (PK) assessment. PYX-201 monoclonal antibody (mAb) was used as the reference standard, goat anti-human IgG polyclonal antibody (pAb) or rabbit anti-human Kappa light chain mAb was employed as the capture antibody, and mouse mAb or goat pAb anti-human IgG the crystallizable fragment (Fc) (horseradish peroxidase (HRP)) was utilized as the detection antibody in this ELISA. This assay was validated with a dynamic range 250 - 10,000 ng/mL and 250 - 6000 ng/mL in rat and monkey K2EDTA plasma, respectively. PYX-201 tAb bioanalytical ELISA assay was reported for the first time in any biological matrix. This is the first time for a bioanalytical method to be validated for a tAb from an ADC drug targeting EDB + FN in any biological matrix.


Assuntos
Imunoconjugados , Camundongos , Ratos , Animais , Coelhos , Ensaio de Imunoadsorção Enzimática , Anticorpos Monoclonais , Peroxidase do Rábano Silvestre , Imunoglobulina G
5.
Artigo em Inglês | MEDLINE | ID: mdl-37094503

RESUMO

PYX-201 is an anti-extra domain B splice variant of fibronectin (EDB + FN) antibody drug conjugate (ADC) composed of a fully human IgG1 antibody, a cleavable mcValCitPABC linker, and four Auristatin 0101 (Aur0101, PF-06380101) payload molecules. To better understand the pharmacokinetic (PK) profile of PYX-201 after it is administered to cancer patients, the development of a reliable bioanalytical assay to accurately and precisely quantitate PYX-201 in human plasma is required. In this manuscript, we present a hybrid immunoaffinity LC-MS/MS assay used to successfully analyze PYX-201 in human plasma. PYX-201 was enriched by MABSelect beads coated with protein A in human plasma samples. The bound proteins were subjected to "on-bead" proteolysis with papain to release the payload Aur0101. The stable isotope labelled internal standard (SIL-IS) Aur0101-d8 was added and the released Aur0101 was quantified as a surrogate for the total ADC concentration. The separation was performed on a UPLC C18 column coupled with tandem mass spectrometry. The LC-MS/MS assay was validated over the range 0.0250 to 25.0 µg/mL with excellent accuracy and precision. The overall accuracy (%RE) was between -3.8% and -0.1% and the inter-assay precision (%CV) was <5.8%. PYX-201 was found to be stable in human plasma for at least 24 h on ice, 15 days after being stored at -80 °C, as well as after five freeze/thaw cycles of being frozen at -25 °C or -80 °C and thawed on ice. The assay this paper reports on, has been successfully applied to human sample analysis to support clinical studies.


Assuntos
Imunoconjugados , Humanos , Cromatografia Líquida/métodos , Imunoconjugados/química , Espectrometria de Massas em Tandem/métodos , Gelo/análise
6.
Bioanalysis ; 15(1): 43-52, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36876967

RESUMO

Aim: PYX-201 is a novel antibody-drug conjugate targeting the extra domain B splice variant of fibronectin in the tumor microenvironment. Accurate quantification of PYX-201 is critical for PYX-201 pharmacokinetics profiling in preclinical studies. Materials & methods: ELISA was performed using reference standard PYX-201, mouse monoclonal anti-monomethyl auristatin E antibody, mouse IgG1, mouse monoclonal anti-human IgG horseradish peroxidase and donkey anti-human IgG horseradish peroxidase. Results: This assay was validated at 50.0-10,000 ng/ml in rat dipotassium EDTA plasma and 250-10,000 ng/ml in monkey dipotassium EDTA plasma. Conclusion: This is the first time for a PYX-201 bioanalytical assay in any matrix to be reported.


Assuntos
Imunoconjugados , Ratos , Camundongos , Animais , Ácido Edético , Ensaio de Imunoadsorção Enzimática , Imunoglobulina G
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA