Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
PLoS One ; 18(4): e0281811, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37036876

RESUMO

IMPORTANCE: Aortic stenosis (AS) is one of the most common heart valve conditions and its incidence and prevalence increases with age. With the introduction of transcatheter aortic valve replacement (TAVR), racial and ethnic disparities in AS diagnosis, treatment and outcomes is poorly understood. OBJECTIVE: In this study we assessed racial and ethnic disparities in AS diagnosis, treatment, and outcomes among Medicare beneficiaries. DESIGN: We conducted a population-based cohort study of inpatient, outpatient, and professional claims from a 20% sample of Medicare beneficiaries. MAIN OUTCOMES AND MEASURES: Incidence and Prevalence was determined among Medicare Beneficiaries. Outcomes in this study included management; the number of (non)-interventional cardiology and cardiothoracic surgery evaluation and management (E&M) visits, and number of transthoracic echocardiograms (TTE) performed. Treatment, which was defined as Surgical Aortic Valve Replacement and Transthoracic Aortic Valve Replacement. And outcomes described as All-cause Hospitalizations, Heart Failure Hospitalization and 1-year mortality. RESULTS: A total of 1,513,455 Medicare beneficiaries were diagnosed with AS (91.3% White, 4.5% Black, 1.1% Hispanic, 3.1% Asian and North American Native) between 2010 and 2018. Annual prevalence of AS diagnosis was lower for racial and ethnic minorities compared with White patients, with adjusted rate ratios of 0.66 (95% CI 0.65 to 0.68) for Black patients, 0.67 (95% CI 0.64 to 0.70) for Hispanic patients and 0.75 (95% CI 0.73 to 0.77) for Asian and North American Native patients as recent as 2018. After adjusting for age, sex and comorbidities, cardiothoracic surgery E&M visits and treatment rates were significantly lower for Black, Hispanic and Asian and North American Native patients compared with White patients. All-cause hospitalization rate was higher for Black and Hispanic patients compared with White patient. 1-year mortality was higher for Black patients, while Hispanic and Asian and North American Native patients had lower 1-year mortality compared with White patients. CONCLUSIONS AND RELEVANCE: We demonstrated significant racial and ethnic disparities in the diagnosis, management and outcomes of AS. The factors driving the persistence of these disparities in AS care need to be elucidated to develop an equitable health care system.


Assuntos
Estenose da Valva Aórtica , Etnicidade , Disparidades em Assistência à Saúde , Grupos Raciais , Idoso , Humanos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Medicare , Estados Unidos/epidemiologia
2.
Front Cardiovasc Med ; 9: 959517, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36267637

RESUMO

Objective: Focal intimal flaps (FIF) are a variety of defects of the aorta that result in a short, flap-like projection into the lumen, and are often encountered in asymptomatic patients undergoing computed tomography angiography (CTA) surveillance for aortic aneurysm, but the natural history and clinical significance of such lesions has not yet been studied. Methods: We retrospectively identified patients with an asymptomatic FIF and available imaging follow-up (>1 year). FIF was defined as flap-like intimal irregularity < 4 cm in length involving the thoracic aorta (TA), abdominal aorta (AA) or common iliac arteries (CIA). FIF characteristics included length and circumferential extent as well as the presence and size (width and depth) of associated penetrating aortic ulcers (PAUs). Patient characteristics, adverse events and history of surgical repair was determined by chart review. FIFs and associated PAUs were assessed for progression by comparing baseline and follow-up CTA studies. Results: A total of 84 FIFs were identified in 77 patients. Average age was 69.2 ± 10.1 years, and 81% were male (81%). Common co-morbidities included: hypertension (78%), hyperlipidemia (68%), smoking (60%), coronary artery disease (41%), aortic aneurysm (34%), type II diabetes mellitus (27%) and prior cardiovascular surgery (25%). FIFs were most commonly located in the abdominal aorta (n = 50, 60%). Nearly all FIFs were associated with local atherosclerotic plaque (93%). Mean follow-up interval was 3.5 ± 2.6 years (259 cumulative follow-up years). Change in FIF length and local aortic diameter over follow-up were 0.7 ± 2.3 mm and 0.8 ± 1.1 mm, respectively. Nearly half (47%) of FIFs were associated with penetrating aortic ulcers (PAU) with baseline depth of 7.3 mm (IQR: 6.1-10.2) and change in depth of 0.5 ± 1.4 mm. Only 12% of FIFs and 0% of associated PAUs demonstrated growth (≥3 mm) at follow-up. No acute pathology developed in the location of FIFs and no aortic interventions were performed specifically to treat FIFs. Conclusion: Focal intimal flaps identified in asymptomatic patients with aortic disease were co-localized with atherosclerotic plaque and PAUs, and demonstrated indolent behavior, not leading to significant growth or acute aortic events, supporting a conservative management approach.

3.
Ann Thorac Surg ; 114(6): 2163-2171, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34774492

RESUMO

BACKGROUND: Various surgical options have been described for the treatment of aberrant subclavian arteries and an associated Kommerell diverticulum. METHODS: Between 1999 and 2019, 43 patients underwent a repair, comprising 26 (61%) endovascular and 17 (39%) open approaches. The endovascular approach consisted of initial subclavian revascularization followed by thoracic endovascular aortic repair. The open approach included total arch replacement (12%) and reverse hemiarch repair with left thoracotomy (53%) or right thoracotomy (35%). The perioperative and long-term outcomes were retrospectively reviewed. RESULTS: No mortality occurred in the endovascular group, whereas there was 1 (6%) in the open approach group. Patients in the endovascular group demonstrated a shorter hospital stay (3.5 days vs 10.0 days; P = .001) and less frequent prolonged mechanical ventilation (0% vs 24%; P = .019), with a lower occurrence of pneumonia (0% vs 24%; P = .019). Among patients who had the endovascular approach, shrinkage of Kommerell diverticulum or aberrant vessel origin was seen in 96%. Furthermore, relief of dysphagia was confirmed in 92% (12/13), including patients without Kommerell diverticulum (n = 3) after endovascular repair. The cumulative incidence of treatment failure or aortic reintervention at 7 years was 21% and 14 % in the endovascular and open approach groups, respectively (P = .62). Two (8%) patients in the endovascular group required an open reintervention. One reintervention was performed for persistent dysphagia in the setting of an untreated complete vascular ring, and the other was for persistent false lumen flow associated with aortic dissection. CONCLUSIONS: The treatment approach should be individualized on the basis of the aortic disease and comorbidities. The endovascular approach is a viable and effective alternative in the presence of suitable landing zones.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Transtornos de Deglutição , Divertículo , Procedimentos Endovasculares , Cardiopatias Congênitas , Humanos , Artéria Subclávia/cirurgia , Transtornos de Deglutição/cirurgia , Transtornos de Deglutição/complicações , Estudos Retrospectivos , Divertículo/cirurgia , Divertículo/complicações , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Cardiopatias Congênitas/cirurgia , Resultado do Tratamento , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações
4.
PLoS Comput Biol ; 17(5): e1008881, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33970900

RESUMO

In this work, we describe the CRIMSON (CardiovasculaR Integrated Modelling and SimulatiON) software environment. CRIMSON provides a powerful, customizable and user-friendly system for performing three-dimensional and reduced-order computational haemodynamics studies via a pipeline which involves: 1) segmenting vascular structures from medical images; 2) constructing analytic arterial and venous geometric models; 3) performing finite element mesh generation; 4) designing, and 5) applying boundary conditions; 6) running incompressible Navier-Stokes simulations of blood flow with fluid-structure interaction capabilities; and 7) post-processing and visualizing the results, including velocity, pressure and wall shear stress fields. A key aim of CRIMSON is to create a software environment that makes powerful computational haemodynamics tools accessible to a wide audience, including clinicians and students, both within our research laboratories and throughout the community. The overall philosophy is to leverage best-in-class open source standards for medical image processing, parallel flow computation, geometric solid modelling, data assimilation, and mesh generation. It is actively used by researchers in Europe, North and South America, Asia, and Australia. It has been applied to numerous clinical problems; we illustrate applications of CRIMSON to real-world problems using examples ranging from pre-operative surgical planning to medical device design optimization.


Assuntos
Hemodinâmica/fisiologia , Modelos Cardiovasculares , Software , Síndrome de Alagille/fisiopatologia , Síndrome de Alagille/cirurgia , Vasos Sanguíneos/anatomia & histologia , Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/fisiologia , Biologia Computacional , Simulação por Computador , Análise de Elementos Finitos , Fatores de Risco de Doenças Cardíacas , Humanos , Imageamento Tridimensional , Transplante de Fígado/efeitos adversos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Modelos Anatômicos , Modelagem Computacional Específica para o Paciente , Complicações Pós-Operatórias/etiologia , Interface Usuário-Computador
5.
Interact Cardiovasc Thorac Surg ; 33(3): 434-441, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-33963411

RESUMO

OBJECTIVES: Differential luminal enhancement [between true lumen (TL) and false lumen (FL)] results from differential flow patterns, most likely due to outflow restriction in the FL. We aimed to assess the impact of differential luminal enhancement at baseline computed tomography angiography on the risk of adverse events in patients with acute type B aortic dissection (TBAD). METHODS: Baseline computed tomography angiographies of patients with acute TBAD between 2007 and 2016 (n = 48) were analysed using three-dimensional software at multiple sites along the descending thoraco-abdominal aorta. At each location, we measured contrast density in TL and FL [Houndsfield unit (HU)], maximal diameter (cm) and circumferential FL extent (°). Outcome data were collected via retrospective chart review. Multivariable logistic regression models were employed to determine the independent risk of TL-FL differential luminal enhancement on aneurysm formation (maximal diameter ≥55 mm) and medical treatment failure. RESULTS: Patients were predominately male (75%) and 52.8±12.9 years at diagnosis. The mean follow-up was 5.9±2.6 years, and 42% (n = 20/48) patients were diagnosed with thoraco-abdominal aortic aneurysm. The baseline absolute difference between FL and TL contrast density measured at 2 cm distal to primary entry tear (TL-FLabs-Tear) was significantly higher among patients who developed aneurysm (26 HU, IQR: 15-53 vs 13 HU, IQR: 4-24, P = 0.001). Aneurysm development during follow-up was predicted by TL-FLabs-Tear (odds ratio 1.07, P = 0.012) and baseline maximal aortic diameter (odds ratio 1.90, P < 0.001). High (≥18 HU) differential luminal enhancement was associated with lower rates of aneurysm-free survival and higher rates of medical treatment failure. CONCLUSIONS: Differential luminal enhancement may be a novel predictor of aneurysm formation among patients with acute TBAD.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Aortografia , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
6.
Eur J Cardiothorac Surg ; 60(3): 651-659, 2021 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-33779717

RESUMO

OBJECTIVES: Confident growth assessment during imaging follow-up is often limited by substantial variability of diameter measurements and the fact that growth does not always occur at standard measurement locations. There is a need for imaging-based techniques to more accurately assess growth. In this study, we investigated the feasibility of a three-dimensional aortic growth assessment technique to quantify aortic growth in patients following open aortic repair. METHODS: Three-dimensional aortic growth was measured using vascular deformation mapping (VDM), a technique which quantifies the localized rate of volumetric growth at the aortic wall, expressed in units of Jacobian (J) per year. We included 16 patients and analysed 6 aortic segments per patient (96 total segments). Growth was assessed by 3 metrics: clinically reported diameters, Jacobian determinant and targeted diameter re-measurements. RESULTS: VDM was able to clearly depict the presence or absence of localized aortic growth and allows for an assessment of the distribution of growth and its relation to anatomic landmarks (e.g. anastomoses, branch arteries). Targeted diameter change showed a stronger and significant correlation with J (r = 0.20, P = 0.047) compared to clinical diameter change (r = 0.15, P = 0.141). Among 20/96 (21%) segments with growth identified by VDM, growth was confirmed by clinical measurements in 7 and targeted re-measurements in 11. Agreement of growth assessments between VDM and diameter measurements was slightly higher for targeted re-measurements (kappa = 0.38) compared to clinical measurements (kappa = 0.25). CONCLUSIONS: Aortic growth is often uncertain and underappreciated when assessed via standard diameter measurements. Three-dimensional growth assessment with VDM offers a more comprehensive assessment of growth, allows for targeted diameter measurements and could be an additional tool to determine which post-surgical patients at high and low risk for future complications.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Aorta/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X
7.
J Card Surg ; 36(1): 268-279, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33169411

RESUMO

PURPOSE: Up to 10% of acute type A aortic dissection (TAAD) patients are deemed unfit for open surgical repair, exposing these patients to high mortality rates. In recent years, thoracic endovascular aortic repair has proven to be a promising alternative treatment modality in specific cases. This study presents a comprehensive overview of the current state of catheter-based interventions in the setting of primary TAAD. METHODS: A literature search was conducted, using MEDLINE and PubMed databases according to PRISMA guidelines, updated until January 2020. Articles were selected if they reported on the endovascular repair of DeBakey Type I and II aortic dissections. The exclusion criteria were retrograde type A dissection, hybrid procedures, and combined outcome reporting of mixed aortic pathologies (e.g., pseudoaneurysm and intramural hematoma). RESULTS: A total of 31 articles, out of which 19 were case reports and 12 case series, describing a total of 92 patients, were included. The median follow-up was 6 months for case reports and the average follow-up was 14 months for case series. Overall technical success was 95.6% and 30-day mortality of 9%. Stroke and early endoleak rates were 6% and 18%, respectively. Reintervention was required in 14 patients (15%). CONCLUSION: This review not only demonstrates that endovascular repair in the setting of isolated TAAD is feasible with acceptable outcomes at short-term follow-up, but also underlines a lack of mid-late outcomes and reporting consistency. Studies with longer follow-up and careful consideration of patient selection are required before endovascular interventions can be widely introduced.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Torácica/cirurgia , Dissecação , Humanos , Estudos Retrospectivos , Fatores de Risco , Stents , Resultado do Tratamento
8.
Eur J Cardiothorac Surg ; 55(2): 331-337, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30165590

RESUMO

OBJECTIVES: Surgical repair of coarctation of the aorta (CoA) is often possible through left thoracotomy and without the use of cardiopulmonary bypass. Recent studies reporting the outcome after CoA repair through left thoracotomy are limited. Therefore, the aim of this study is to evaluate the results of CoA repair through left thoracotomy in children who were operated on in our centre over the past 21 years. METHODS: From January 1995 to December 2016, 292 patients younger than 18 years underwent primary CoA repair through left thoracotomy at our 2 institutions. Peri- and postoperative data and follow-up data collected from our hospital and the referring hospitals were retrospectively reviewed. RESULTS: Median age at operation was 64 days (range 2 days-17 years). Most patients underwent the resection of the CoA followed by an (extended) end-to-end anastomosis (93%). Six patients died perioperatively and 2 more patients died during the follow-up, of which 7 patients had other major comorbidities. Actuarial survival was 97% at 5 years, 96% at 10 years and 96% at 15 years. Second arch interventions due to recoarctation were performed in 9.9% (n = 29) of patients, consisting of balloon dilatation in all but 2 patients. Recoarctation occurred significantly more often after initial repair in the neonatal period (21%) and could occur as late as 14 years after initial surgery. There were 7 re-recoarctations, and 14% of patients were on hypertensive medication during the follow-up. CONCLUSIONS: Repair of CoA through left thoracotomy is a safe procedure with low rates of mortality. The long-term follow-up is necessary due to the significant risk of recoarctation requiring reintervention.


Assuntos
Coartação Aórtica , Toracotomia , Coartação Aórtica/mortalidade , Coartação Aórtica/cirurgia , Pré-Escolar , Feminino , Humanos , Hipertensão , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias , Reoperação/efeitos adversos , Reoperação/mortalidade , Estudos Retrospectivos , Toracotomia/efeitos adversos , Toracotomia/mortalidade , Resultado do Tratamento
9.
Eur J Cardiothorac Surg ; 50(3): 456-63, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26984988

RESUMO

OBJECTIVES: In patients with congenitally corrected transposition of the great arteries (ccTGA) or after atrial (Mustard or Senning) correction for transposition of the great arteries (acTGA), the right ventricle (RV) supports the systemic circulation. The tricuspid valve (TV) (systemic atrioventricular valve) is prone to regurgitation in these patients and this is associated with impending RV failure and decreased survival. This study evaluates mid-term functional improvements, echocardiographic findings and survival after TV surgery in this patient group. METHODS: From July 1999 to November 2014, 26 patients (mean age 37.1 ± 12.3 years, 14 females) with ccTGA (n = 15) or acTGA (n = 11) had TV surgery. All patients had RV dysfunction and more-than-moderate TV regurgitation (TR); 14 underwent TV replacement (TVR) and 12 had valvuloplasty (TVP). Main outcomes were New York Heart Association (NYHA) functional class, TR and RV dysfunction at 1 year postoperatively and at latest follow-up. Complications and freedom from the composite end-point of death or recurrent TR were analysed. RESULTS: The median follow-up time was 5.9 years (range, 0-16.1 years). Mean NYHA functional class significantly improved to 1.7 [95% confidence interval (CI): 1.3-2.1] at 1 year (P= 0.004) and was 2.1 (95% CI: 1.7-2.6) at latest follow-up (P= 0.14). TV competence significantly improved to a mean TR grade of 1.1 (95% CI: 0.5-1.7) at latest follow-up (P< 0.001). The mean grade for RV function at latest follow-up was 2.7 (95% CI: 2.3-3.0). Most encountered postoperative complications were arrhythmias and temporary haemodynamic instability due to low cardiac output. Early mortality was 11.5% (n = 3); late mortality was 15.4% (n = 4). Estimated freedom from the composite end-point of death or recurrent TR was 76.9% (95% CI: 55.7-88.9%) at 1 year and 64.8% (95% CI: 43.2-79.9%) at 5 years. In TVP patients, TV function at 1 year and at latest follow-up was significantly worse than in TVR patients (P< 0.001 and P= 0.003, respectively). Also, TVP patients had a significantly lower composite end-point survival curve compared with TVR patients (P= 0.018). CONCLUSIONS: In this patient group, TV surgery showed stabilization of RV function and improvement of NYHA functional class for at least several years. In this series, TVR appears superior to TVP with respect to occurrence of recurrent TR. Early and late mortality after TV surgery is substantial, and we believe that patients with significant TR should be referred earlier for surgery for better outcome.


Assuntos
Valvuloplastia com Balão/métodos , Implante de Prótese de Valva Cardíaca/métodos , Transposição dos Grandes Vasos/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/cirurgia , Adulto , Valvuloplastia com Balão/efeitos adversos , Ecocardiografia , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
10.
Food Chem Toxicol ; 48(2): 549-52, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19932731

RESUMO

Six compounds, namely, Lupeol (1), Betulin (2), beta-Taraxerol (3), Taraxerone (4), Stigmasterol (5) and beta-Sitosterol (6) were isolated from the petroleum ether extract of the leaves of Sapium baccatum based on spectroscopic evidence. Lupeol (1), Betulin (2) and Stigmasterol (5) were isolated for the first time from this plant. The cytotoxic potential of the different solvent extracts (methanol, petroleum ether, carbon-tetrachloride and dichloromethane); six column fractions (F-4, F-7, F-10, F-12, F-18 and F-22) of petroleum ether extract and three pure compounds 1, 4 and 6 were determined by using brine shrimp lethality bioassay. The LC50 of all the tested samples were showed to be lethal to brine shrimp nauplii. However, petroleum ether, carbon-tetrachloride extract, column fractions F-4 and F-18 of petroleum ether extract and pure compound 6 showed quite potent activity in brine shrimp lethality bioassay with LC50 1.33, 1.35, 1.40, 1.58 and 1.58 microg/ml, respectively. These result suggested that they might be contain antitumor or pesticidal activity. Further, the methanol extract and four column fractions (F-7, F-12, F-18 and F-22) of petroleum ether showed significant activity against the tested microorganisms.


Assuntos
Antibacterianos/farmacologia , Citotoxinas/farmacologia , Extratos Vegetais/farmacologia , Sapium/química , Animais , Artemia/efeitos dos fármacos , Fracionamento Químico , Longevidade/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Folhas de Planta/química , Solventes/química , Testes de Toxicidade Aguda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA