Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Med Invest ; 71(1.2): 141-147, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38735710

RESUMO

CapeOX is a regimen used as postoperative adjuvant chemotherapy for the treatment of advanced recurrent colorectal cancer. If early adverse events occur, treatment may not progress as planned and further dose reduction may be necessary. In this study, we investigated whether pre-treatment medical records could be used to predict adverse events in order to prevent adverse events caused by CapeOX treatment. The 178 patients were classified into two groups (97 in the adverse event positive group and 81 in the adverse event-negative group) based on withdrawal or postponement of four or fewer courses. In univariate analysis, age, height, weight, body surface area (BSA), creatinine clearance, muscle mass, and lean body mass were associated with early adverse events (P<0.05). The area under the receiver operating characteristic curve obtained by Stepwise logistic regression analysis using the Akaike information criterion method was 0.832. For nested k-fold cross validation, the accuracy rates of the support vector machine, random forest, and logistic regression algorithms were 0.71, 0.70, and 0.75, respectively. The results of the present study suggest that a logistic regression prediction model may be useful in predicting early adverse events caused by CapeOX therapy in patients with colorectal cancer. J. Med. Invest. 71 : 141-147, February, 2024.


Assuntos
Neoplasias Colorretais , Humanos , Neoplasias Colorretais/tratamento farmacológico , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Capecitabina/efeitos adversos , Capecitabina/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Idoso de 80 Anos ou mais , Adulto , Estudos Retrospectivos
2.
Radiat Prot Dosimetry ; 199(19): 2391-2395, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37609988

RESUMO

In recent years, radiochromic films have begun to be used for dosimetry in mammography; however, the most sensitive GAFCHROMIC XR-QA2 (XR-QA2) film is no longer available owing to its discontinuation. In this study, we evaluated the sensitivity characteristics of GAFCHROMIC LD-V1 (LD-V1) as an alternative to XR-QA2 in the field of mammography, at a low dose and low energy. Our results show that the average ratio of the concentration change of LD-V1 divided by the concentration change of XR-QA2 at each absorbed dose was 53.7%, indicating the sensitivity of LD-V1 to be approximately half of XR-QA2. In addition, the linearity of the concentration change is sufficient even within a dose range of 0.59-14.52 mGy, which is lower than the manufacturer's recommended dose range. Therefore, the LD-V1 is capable of accurate dose assessment even with a low dose and the low level of energy used in mammography.


Assuntos
Dosimetria Fotográfica , Radiometria , Doses de Radiação , Dosimetria Fotográfica/métodos , Calibragem , Mamografia
3.
Radiat Prot Dosimetry ; 199(8-9): 1007-1011, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37225196

RESUMO

Mammography is one of the most effective diagnostic methods for the early detection of breast cancer; however, it poses the risk of radiation exposure. To date, mammography dosimetry has been performed according to the mean glandular dose; however, the actual exposure in the breast has not been assessed. Here, we have measured dose distributions and depth doses using both radiochromic films and mammographic phantoms, and a three-dimensional intra-mammary dose assessment was conducted. The absorbed dose distribution at the surface was markedly higher on the chest wall side but lower on the nipple side. The absorbed doses in the depth direction exponentially decreased. The glandular tissue near the surface may be irradiated with an absorbed dose of 7.0 mGy or higher. Since LD-V1 could be placed inside the phantom, the absorbed dose inside the breast could also be evaluated in three dimensions.


Assuntos
Mamografia , Exposição à Radiação , Radiometria , Tórax , Imagens de Fantasmas
4.
Radiat Prot Dosimetry ; 199(8-9): 1002-1006, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37225197

RESUMO

The effects of lead equivalent and lens area of radiation-protective eyewear on lens exposure control were examined. The simulated patient underwent 10-min X-ray fluoroscopy, and the lens dose of the simulated surgeon wearing radiation protection glasses was measured using lens dosemeters attached to the corner of the eye and eyeball. In total, 10 types of radiation protection glasses were selected for measurement. Correlation analysis of the equivalent dose in the lens of the eye with lead equivalence and lens area was performed. The equivalent dose in the lens of the eye of the corner of the eye was negatively correlated with the area of the lens. The equivalent dose in the lens of the eye and the eyeball showed a strong negative correlation with lead equivalence. Lens dosemeters worn at the corner of the eye may overestimate the equivalent dose in the lens of the eye. Moreover, the reduction in exposure of the lens was significantly influenced by the lead equivalent.


Assuntos
Cristalino , Proteção Radiológica , Cirurgiões , Humanos , Olho
5.
Radiat Prot Dosimetry ; 196(3-4): 226-233, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34668552

RESUMO

This study developed a phantom with a shape similar to that of the breast and use GAFCHROMIC films that can be placed inside the phantom to measure the detailed breast dose distribution in mammography. GAFCHROMIC EBT3 was placed on the block cube breast phantom and irradiated with a mammography device to measure the absorbed dose distribution inside the phantom in the horizontal and depth directions. The dose distribution in the horizontal plane was the highest in the centre on the chest wall side, and it decreased in a fan shape. Along the depth of the phantom, the doses absorbed across the entire cross-section were 16.15 mGy at the surface and 7.51, 3.25 and 1.68 mGy at depths of 10, 20 and 30 mm, respectively. Compared with the mean glandular dose, the proposed method can measure breast dose distributions in greater detail and is applicable to various breast shapes.


Assuntos
Dosimetria Fotográfica , Radiometria , Mama/diagnóstico por imagem , Mamografia , Imagens de Fantasmas
6.
Cardiovasc Intervent Radiol ; 42(1): 69-77, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30039504

RESUMO

PURPOSE: To evaluate the accuracy of the virtual liver parenchymal perfusion area using a commercially available workstation and liver analysis software in conventional transarterial chemoembolization (cTACE) for hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This method was retrospectively applied to 29 treated HCCs in 23 patients. The virtual embolic area (VEA) was estimated based on cone beam computed tomography during hepatic arteriography using a commercially available workstation and liver analysis software by two observer groups (group A: experts; group B: semi-experts). The real embolic area (REA) was defined as the area where iodized oil accumulated on computed tomography at 1 week after cTACE. The REA was estimated by each of the two groups, and the mean REA between the groups (mREA) was used as a standard reference. Agreement of volume and cross-sectional area in three orthogonal planes between the VEA and mREA were analyzed using intraclass correlation coefficients (ICCs) and Bland-Altman plots. RESULTS: The ICCs for volume between VEA and mREA were 0.97 and 0.88 for groups A and B, respectively, and those for cross-sectional area were 0.94 and 0.88 for the axial plane, 0.95 and 0.83 for the coronal plane, and 0.87 and 0.74 for the sagittal plane, respectively. Thus, the overall agreement was excellent, except for the sagittal imaging plane in group B. CONCLUSION: This method using a commercially available workstation and liver analysis software can be useful for estimating the embolic area in cTACE.


Assuntos
Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/terapia , Terapia Assistida por Computador , Interface Usuário-Computador , Idoso , Angiografia , Angiografia Digital , Tomografia Computadorizada de Feixe Cônico/métodos , Óleo Etiodado , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/irrigação sanguínea , Recidiva Local de Neoplasia/terapia , Proibitinas , Estudos Retrospectivos , Software
7.
J Appl Clin Med Phys ; 17(3): 41-51, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167258

RESUMO

This study investigates an X-ray dose measurement method for computed tomography using Gafchromic films. Nonuniformity of the active layer is a major problem in Gafchromic films. In radiotherapy, nonuniformity error is reduced by applying the double-exposure technique, but this is impractical in diagnostic radiology because of the heel effect. Therefore, we propose replacing the X-rays in the double-exposure technique with ultraviolet (UV)-A irradiation of Gafchromic EBT2 and EBT3. To improve the reproducibility of the scan position, Gafchromic EBT2 and EBT3 films were attached to a 3-mm-thick acrylic plate. The samples were then irradiated with a 10 W UV-A fluorescent lamp placed at a distance of 72cm for 30, 60, and 90 minutes. The profile curves were evaluated along the long and short axes of the film center, and the standard deviations of the pixel values were calculated over large areas of the films. Paired t-test was performed. UV-A irradiation exerted a significant effect on Gafchromic EBT2 (paired t-test; p = 0.0275) but not on EBT3 (paired t-test; p = 0.2785). Similarly, the homogeneity was improved in Gafchromic EBT2 but not in EBT3. Therefore, the double-exposure technique under UV-A irradiation is suitable only for EBT2 films.


Assuntos
Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Humanos , Doses de Radiação , Reprodutibilidade dos Testes , Raios Ultravioleta , Raios X
8.
Asian J Endosc Surg ; 9(3): 179-85, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27122447

RESUMO

INTRODUCTION: We evaluated 3-D CT imaging for preoperative classification of the left gastric artery and vein in patients with early gastric cancer and estimated its clinical benefit. METHODS: Between April 2009 and March 2014, 279 patients underwent preoperative 3-D CT using a 64-row multi-detector CT scanner, followed by laparoscopy-assisted distal gastrectomy. The 3-D CT images of the arterial and portal phases were reconstructed and fused. The operative outcomes were compared between patients who had not undergone 3-D CT (2007-2008) and who had undergone 3-D CT (2009-2011). RESULTS: According to Adachi's classification, the numbers of type I, II, III, IV, V, and VI arterial patterns were 253, 15, 1, 3, 3, and 1, respectively. Three cases could not be classified. According to the Douglass classification, the left gastric vein flowed into the portal vein, splenic vein, junction of the portal vein and splenic vein, and left branch of the portal vein in 119, 111, 36, and 5 patients, respectively. The left gastric vein could not be visualized in six patients, and two patients could not be classified. In addition, the relation was absent for an Adachi type I vein and one of the "other" types of veins. The total operative time was significantly shorter with 3-D CT than without it (P = 0.01), and the degree of lymph-node dissection was significantly higher (P = 0.01). Inflammatory parameters and operative morbidity tended to decrease with 3-D CT. CONCLUSION: Three-dimensional CT is a useful modality to visualize the vessel anatomy around the stomach, and it improves clinical effectiveness and reduces the invasiveness of surgery.


Assuntos
Gastrectomia , Imageamento Tridimensional , Laparoscopia , Tomografia Computadorizada Multidetectores/métodos , Cuidados Pré-Operatórios/métodos , Neoplasias Gástricas/cirurgia , Estômago/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Artéria Celíaca/diagnóstico por imagem , Feminino , Gastrectomia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estômago/diagnóstico por imagem , Estômago/cirurgia , Resultado do Tratamento , Veias/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA