Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int Ophthalmol ; 44(1): 199, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662017

RESUMO

PURPOSE: To explore whether differences in choroidal thickness arise from nicotine consumption in healthy young individuals, specifically comparing the effects of nicotine gum to electronic cigarette (vaping), while maintaining a consistent 4 mg nicotine dosage. METHODS: In a randomized double-blinded prospective cross-sectional study, 20 healthy participants (mean age ± standard deviation: 23 ± 2.36 years) were randomly assigned to either the nicotine gum or vaping group. Choroidal thickness (ChT) measurements were conducted using optical coherence tomography (OCT) (Topcon 3D OCT-1 Maestro System) at baseline, 30, and 60 min after ingesting 4 mg of nicotine, with ChT measurements taken from five different horizontal areas. RESULTS: Neither the nicotine delivery method (gum or vaping) demonstrated a statistically significant impact on ChT mean scores among subjects in the five measured areas at baseline, 30, and 60 min (p > 0.05). However, significant differences were observed in ChT mean scores within subjects across the five areas (F (1.83, 72) = 36.43, p < 0.001), regardless of other study factors such as group, time, and visit (p > 0.05). A statistically significant interaction was identified between the factors of area and time concerning participants' ChT mean scores when stratified by the type of smoking (tobacco, vaping, and dual) (p = 0.003). CONCLUSION: The results of this study revealed that nicotine, up to particular concentration of 4 mg, does not have a statistically significant vasoconstrictive effect on choroidal thickness, regardless of the delivery method, within the examined group. These findings offer valuable insights into the relationship between nicotine intake and choroidal dynamics in young adults.


Assuntos
Corioide , Sistemas Eletrônicos de Liberação de Nicotina , Nicotina , Tomografia de Coerência Óptica , Humanos , Corioide/patologia , Corioide/diagnóstico por imagem , Corioide/efeitos dos fármacos , Masculino , Método Duplo-Cego , Feminino , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Estudos Transversais , Adulto Jovem , Adulto , Nicotina/administração & dosagem , Nicotina/efeitos adversos , Abandono do Hábito de Fumar/métodos , Dispositivos para o Abandono do Uso de Tabaco , Goma de Mascar de Nicotina
2.
Int J Ophthalmol ; 17(2): 247-256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38371246

RESUMO

AIM: To investigate the impact of multifocal gas permeable contact lens (MFGPCL) in various add power and distance/near area allocation on short-term changes of choroidal thickness (ChT), axial length (AL), and retinal defocus profile in young adults. METHODS: Seventeen young adults (2 males and 15 females; age 23.17±4.48y) were randomly assigned to wear two designs binocularly with a one-week washout period in between. Total of four MFGPCL designs were assessed. All designs were distance-center that varied in two add power (+1.50 and 3.00 D) and/or two distance zone (DZ) diameters (1.50 and 3.00 mm; design A: DZ 1.5/add 3.0, B: DZ 1.5/add 1.5, C: DZ 3.0/add 3.0, D: DZ 3.0/add 1.5). ChT, AL, and peripheral refraction data were collected on each subject at baseline, on days 1 and 7 of MFGPCL daily wear. ChT was assessed in four quadrants using a spectral-domain optical coherence tomography. RESULTS: AL was shortened by -26±44 µm with lens C, -18±27 µm with lens D, -13±29 µm with lens A, and -8±30 µm with lens B (all P<0.05). A significant overall increase in ChT was observed with all 4 designs (lens A: +6±6 µm, B: +3±7 µm, C: +8±7 µm, and D: +8±7 µm). Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL. All designs induced significant relative peripheral myopia (RPM) beyond the central 20° across the horizontal meridian in both nasal and temporal fields (P<0.05). CONCLUSION: MFGPCLs show a significant influence on ChT and AL, which are associated with significant increase in RPM after short-term wear. The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.

3.
J Ophthalmol ; 2022: 9970388, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36339726

RESUMO

Purpose: Smoking has a negative effect on health and ocular tear film. The purpose of the current study is to investigate the correlation between the TearLab and I-Pen osmolarity scores in smokers and compare them with those of non-smoking healthy males. Methods: Thirty male smokers (25.3 ± 2.2 years) participated in the study. An age-matched (22.9 ± 2.0 years) control group of non-smoking healthy males (N = 30) was also recruited for comparison purposes. The ocular surface disease index (OSDI) was completed first, followed by the TearLab and I-Pen osmolarity measurements. Results: The median TearLab osmolarity score was lower (P < 0.001) than that obtained using the I-Pen in both the study and the control groups. The OSDI scores and osmolality measurements were higher (P < 0.001) in smokers than in the control subjects. In the smoker group, there were moderate correlations between the OSDI scores and the measurements obtained using the TearLab (Spearman's correlation coefficient, r = 0.463; P = 0.010) and I-Pen (r = 0.449; P = 0.013) systems. In addition, there was a strong correlation between the osmolarity scores obtained from the TearLab and I-Pen systems in smokers (r = 0.911; P < 0.001). Conclusion: The I-Pen scores in smokers were significantly higher than those obtained using TearLab. The TearLab scores showed small variations compared with those obtained using I-Pen. A strong correlation was found between the TearLab and I-Pen scores in smokers. The osmolarity TearLab and I-Pen scores were significantly higher in smokers compared with normal eye subjects.

4.
Pharmaceuticals (Basel) ; 15(11)2022 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-36422540

RESUMO

Breast cancer represents the most frequently occurring cancer globally among women. As per the recent report of the World Health Organization (WHO), it was documented that by the end of the year 2020, approximately 7.8 million females were positively diagnosed with breast cancer and in 2020 alone, 685,000 casualties were documented due to breast cancer. The use of standard chemotherapeutics includes the frontline treatment option for patients; however, the concomitant side effects represent a major obstacle for their usage. Carbazole alkaloids are one such group of naturally-occurring bioactive compounds belonging to the Rutaceae family. Among the various carbazole alkaloids, 3-Methoxy carbazole or C13H11NO (MHC) is obtained from Clausena heptaphylla as well as from Clausena indica. In this study, MHC was investigated for its anti-breast cancer activity based on molecular interactions with specific proteins related to breast cancer, where the MHC had predicted binding affinities for NF-κB with −8.3 kcal/mol. Furthermore, to evaluate the biological activity of MHC, we studied its in vitro cytotoxic effects on MCF-7 cells. This alkaloid showed significant inhibitory effects and induced apoptosis, as evidenced by enhanced caspase activities and the cellular generation of ROS. It was observed that a treatment with MHC inhibited the gene expression of NF-kB in MCF-7 breast cancer cells. These results suggest that MHC could be a promising medical plant for breast cancer treatment. Further studies are needed to understand the molecular mechanisms behind the anticancer action of MHC.

5.
ACS Omega ; 7(38): 33651-33665, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36164411

RESUMO

SARS-CoV-2 is a novel infectious contagion leading to COVID-19 disease. The virus has affected the lives of millions of people across the globe with a high mortality rate. It predominantly affects the lung (respiratory system), but it also affects other organs, including the cardiovascular, psychological, and gastrointestinal (GIT) systems. Moreover, elderly and comorbid patients with compromised organ functioning and pre-existing polypharmacy have worsened COVID-19-associated complications. Microbiota (MB) of the lung plays an important role in developing COVID-19. The extent of damage mainly depends on the predominance of opportunistic pathogens and, inversely, with the predominance of advantageous commensals. Changes in the gut MB are associated with a bidirectional shift in the interaction among the gut with a number of vital human organs, which leads to severe disease symptoms. This review focuses on dysbiosis in the gut-lung axis, COVID-19-induced worsening of comorbidities, and the influence of polypharmacy on MB.

6.
J Optom ; 15(4): 305-312, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35120873

RESUMO

OBJECTIVES: To evaluate the performance of four experimental multifocal gas permeable contact lens (MFGPCL) designs and their impact on visual function in young adults. METHODS: Seventeen young adults (age, 23.17 ± 4.48 years) enrolled in the study. Each participant was randomly assigned to wear two of four MFGPCL designs. They wore the first type of the assigned lens binocularly for one week and, after one week of washout period, wore another design on both eyes for another week. The four MFGPCL designs were as follows: design A (distance zone [DZ] 1.5 mm / add 3.0 D), B (DZ 1.5 mm / add 1.5 D), C (DZ 3.0 mm / add 3.0 D), and D (DZ 3.0 mm / add 1.5 D). Baseline visual acuity, contrast sensitivity function, and accommodation data were collected at baseline and repeated after one week of MFGPCL daily wear. RESULTS: Distance and near visual acuities were not significant affected with the four MFGPCL designs. Contrast sensitivity was significantly lower in design A across all measured spatial frequencies (p < 0.05), with no significant impact from other designs on all frequencies. No significant effect was observed on accommodation measured at 33 cm (p > 0.05). CONCLUSIONS: Three of the investigated MFGPCL designs preserve satisfactory visual performance. Lens design A incorporated with higher add and smaller center zone diameter had a stronger impact on the visual performance.


Assuntos
Lentes de Contato , Acomodação Ocular , Adulto , Sensibilidades de Contraste , Humanos , Projetos Piloto , Acuidade Visual , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA