Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Gland Surg ; 12(2): 140-151, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36915822

RESUMO

Background: Some studies suggested that the patients included in the Z0011 trial may represent patients with ultrasound-negative axillary nodes and axillary invasion diagnosed by sentinel node (SN) biopsy. Nevertheless, the National Comprehensive Cancer Network (NCCN) guidelines recommend SN mapping if 1 or 2 suspicious lymph nodes are identified on axillary ultrasound (AU). The aim of this preliminary phase of the Multimodal Targeted Axillary Surgery (MUTAS) trial was to establish the accuracy of SN mapping in patients with axillary involvement undergoing upfront surgery. Methods: Between September 2019 and March 2022, we recruited patients with biopsy-proven metastatic axillary nodes and upfront surgery from a single center. We performed SN mapping in these patients before the surgical intervention, which included axillary lymph node dissection. The biopsy-proven metastatic node, SNs and the remaining axillary nodes were excised separately. SN status was considered representative of the status of the remaining axillary nodes. We calculated the sensitivity, specificity, negative predictive value and positive predictive value of the SN, overall and in patients with palpable nodes, in those with non-palpable nodes and an AU leading to diagnosis of axillary involvement, in those with 1 or 2 suspicious nodes on AU, and in patients with a single suspicious node on AU. We evaluated clinical, imaging and pathology features as predictors of the status of the remaining axillary nodes, false-negatives, and false-positives. Results: We included 25 patients in this phase. The false-negative rate of SN mapping was 28% overall, 21.42% for patients with palpable nodes, 36.36% for patients with non-palpable nodes and an AU diagnosis of axillary involvement, 28.75% for those with 1 or 2 suspicious nodes on AU, and 15.38% in patients with a single suspicious node on AU. The negative predictive value was highest in patients with a single suspicious node on AU (75%). The only significant predictive factor was that FN showed a higher Ki67 index score. Conclusions: In this study, SN mapping was not reliable in patients with biopsy-proven metastatic axillary nodes and upfront surgery for any of the subgroups studied. Further research should elucidate the best staging pathways in these patients to avoid premature de-escalation.

2.
Eur Radiol ; 32(11): 7480-7487, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35536390

RESUMO

OBJECTIVES: We compared the compression force, breast thickness, and glandular dose, as well as the severity of discomfort and women's experience between the patient-assisted compression (PAC) and standard compression (SC) modes. MATERIALS AND METHODS: We conducted a prospective randomized controlled study at Hospital del Mar in Barcelona, Spain. We included 448 asymptomatic women aged 50 to 69 years old, attending their screening round from December 2017 to December 2019. Mammograms included the two bilateral views. In each woman, one breast was studied with SC and the other with PAC. The mode used in each breast was selected following a randomized list. Compression force, breast thickness, and average glandular dose were obtained for each of the 1792 images. We also recorded the degree of discomfort and women's experience, after mammogram acquisitions, using a predefined survey. RESULTS: Higher compression forces were obtained with PAC than with SC (99.27 N vs 83.25 N, p < 0.001). Breast thickness mode (56.11 mm vs 57.52 mm, p = 0.015) and glandular dose (1.34 mGy vs 1.37 mGy, p = 0.018) were lower in PAC. The discomfort score was slightly higher with PAC (mean 3.94 vs 3.69, p = 0.042), but in the satisfaction survey, more women reported that PAC caused less discomfort. Additionally, 63.2% of women (289/448) preferred PAC. CONCLUSION: PAC achieved higher compression forces without impairing the other technical imaging parameters and enhanced women's experience of screening mammography. We believe there were no clinically significant differences in the severity of discomfort between the two modes. KEY POINTS: • Self-compression allows higher compression forces than the standard compression mode. • Self-compression does not affect technical imaging parameters. • Self-compression improved women's experience of screening mammography when standard compression was used on one breast and self-compression on the other.


Assuntos
Neoplasias da Mama , Mamografia , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Mamografia/métodos , Detecção Precoce de Câncer , Método Simples-Cego , Estudos Prospectivos , Neoplasias da Mama/diagnóstico por imagem
3.
Eur Radiol ; 32(11): 7470-7479, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35536391

RESUMO

OBJECTIVES: Evaluate the image quality of a mammography screening device using the patient-assisted compression (PAC) compared with the standard compression (SC) mode. METHODS: This prospective within-woman, randomized controlled trial was conducted between September 2017 and December 2019. Participants were asymptomatic women aged 50 to 69 years attending their second or subsequent screening mammography round. By random assignment, one breast underwent the SC and the other breast, the PAC. Image quality was evaluated as perfect, good, moderate, or inadequate (PGMI) on 10 criteria for the craniocaudal (CC) view and 8 criteria for the mediolateral oblique (MLO) view. Pearson's chi-square test, with Yates' correction if pertinent, was performed to compare image quality between compression modes. RESULTS: A total of 444 participants were included (mean [± standard deviation] age, 60 [± 4.9] years). There were no differences in the percentages of PGMI between the PAC and SC modes for the CC view (perfect, 37% [162/444] vs 37% [163/444]; good, 1% [5/444] vs 2% [9/444]; moderate, 62% [277/444] vs 61% [271/444]; inadequate, 0% vs 0.2% [1/444]; p = .88) or for the MLO view (perfect, 53% [237/444] vs 56% [247/444]; good, 22% [99/444] vs 22% [97/444]; moderate, 23% [102/444] vs 22% [98/444]; inadequate, 1% [6/444] vs 0.5% [2/444]; p = .72). No differences were found when we stratified by laterality or when analyzed by PGMI criteria. CONCLUSION: PAC does not seem to impair mammographic image quality. Future research should focus in a daily practice setting. KEY POINTS: No differences were found in the distribution of the PGMI classification, a tool for quality assessment, between patient-assisted compression and standard compression. Similar results were found on stratification of image quality by mammographic view and breast laterality for both types of compression. None of the PGMI criteria had significantly more errors in patient-assisted compression than in standard compression.


Assuntos
Neoplasias da Mama , Mamografia , Feminino , Humanos , Pessoa de Meia-Idade , Mamografia/métodos , Estudos Prospectivos , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer , Mama/diagnóstico por imagem , Hiperplasia
4.
Artigo em Inglês | MEDLINE | ID: mdl-35270331

RESUMO

Assessing the long-term risk of breast cancer after diagnosis of benign breast disease by mammography is of utmost importance to design personalised screening strategies. We analysed individual-level data from 778,306 women aged 50-69 years with at least one mammographic screening participation in any of ten breast cancer screening centers in Spain from 1996 to 2015, and followed-up until 2017. We used Poisson regression to compare the rates of incident breast cancer among women with and without benign breast disease. During a median follow-up of 7.6 years, 11,708 (1.5%) women had an incident of breast cancer and 17,827 (2.3%) had a benign breast disease. The risk of breast cancer was 1.77 times higher among women with benign breast disease than among those without (95% CI: 1.61 to 1.95). The relative risk increased to 1.99 among women followed for less than four years, and remained elevated for two decades, with relative risk 1.96 (95% CI: 1.32 to 2.92) for those followed from 12 to 20 years. Benign breast disease is a long-term risk factor for breast cancer. Women with benign breast disease could benefit from closer surveillance and personalized screening strategies.


Assuntos
Neoplasias da Mama , Doença da Mama Fibrocística , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Detecção Precoce de Câncer , Feminino , Humanos , Mamografia , Programas de Rastreamento , Fatores de Risco
5.
Eur Radiol ; 32(1): 621-629, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34156554

RESUMO

OBJECTIVES: To evaluate the mammographic features in women with benign breast disease (BBD) and the risk of subsequent breast cancer according to their mammographic findings. METHODS: We analyzed data from a Spanish cohort of women screened from 1995 to 2015 and followed up until December 2017 (median follow-up, 5.9 years). We included 10,650 women who had both histologically confirmed BBD and mammographic findings. We evaluated proliferative and nonproliferative BBD subtypes, and their mammographic features: architectural distortion, asymmetries, calcifications, masses, and multiple findings. The adjusted hazard ratios (aHR) and 95% confidence intervals (95% CI) for breast cancer were estimated using a Cox proportional hazards model. We plotted the adjusted cumulative incidence curves. RESULTS: Calcifications were more frequent in proliferative disease with atypia (43.9%) than without atypia (36.8%) or nonproliferative disease (22.2%; p value < 0.05). Masses were more frequent in nonproliferative lesions (59.1%) than in proliferative lesions without atypia (35.1%) or with atypia (30.0%; p value < 0.05). Multiple findings and architectural distortion were more likely in proliferative disease (16.1% and 4.7%) than in nonproliferative disease (12.8% and 1.9%). Subsequent breast cancer occurred in 268 (2.5%) women. Compared with women who had masses, the highest risk of subsequent breast cancer was found in those with architectural distortions (aHR, 2.21; 95% CI, 1.16-4.22), followed by those with multiple findings (aHR, 1.89; 95% CI, 1.34-2.66), asymmetries (aHR, 1.66; 95% CI, 0.84-3.28), and calcifications (aHR, 1.60; 95% CI, 1.21-2.12). CONCLUSION: BBD subtypes showed distinct mammographic findings. The risk of subsequent breast cancer was high in those who have shown architectural distortion, multiple findings, asymmetries, and calcifications than in women with masses. KEY POINTS: • The presence of mammographic findings in women attending breast cancer screening helps clinicians to assess women with benign breast disease (BBD). • Calcifications were frequent in BBDs with atypia, which are the ones with a high breast cancer risk, while masses were common in low-risk BBDs. • The excess risk of subsequent breast cancer in women with BBD was higher in those who showed architectural distortion compared to those with masses.


Assuntos
Neoplasias da Mama , Doença da Mama Fibrocística , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Estudos de Coortes , Detecção Precoce de Câncer , Feminino , Humanos , Mamografia , Fatores de Risco
6.
BJR Open ; 3(1): 20210034, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34877457

RESUMO

Contrast-enhanced mammography (CEM) is a combination of standard mammography and iodinated contrast material administration. During the last decade, CEM has found its place in breast imaging protocols: after i.v. administration of iodinated contrast material, low-energy and high-energy images are retrieved in one acquisition using a dual-energy technique, and a recombined image is constructed enabling visualisation of areas of contrast uptake. The increased incorporation of CEM into everyday clinical practice is reflected in the installation of dedicated equipment worldwide, the (commercial) availability of systems from different vendors, the number of CEM examinations performed, and the number of scientific articles published on the subject. It follows that ever more radiologists will be confronted with this technique, and thus be required to keep up to date with the latest developments in the field. Most importantly, radiologists must have sufficient knowledge on how to interpret CEM images and be acquainted with common artefacts and pitfalls. This comprehensive review provides a practical overview of CEM technique, including CEM-guided biopsy; reading, interpretation and structured reporting of CEM images, including the accompanying learning curve, CEM artefacts and interpretation pitfalls; indications for CEM; disadvantages of CEM; and future developments.

7.
Eur Radiol ; 31(7): 4839-4847, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33409776

RESUMO

OBJECTIVES: Assessing the combined effect of mammographic density and benign breast disease is of utmost importance to design personalized screening strategies. METHODS: We analyzed individual-level data from 294,943 women aged 50-69 years with at least one mammographic screening participation in any of four areas of the Spanish Breast Cancer Screening Program from 1995 to 2015, and followed up until 2017. We used partly conditional Cox models to assess the association between benign breast disease, breast density, and the risk of breast cancer. RESULTS: During a median follow-up of 8.0 years, 3697 (1.25%) women had a breast cancer diagnosis and 5941 (2.01%) had a benign breast disease. More than half of screened women had scattered fibroglandular density (55.0%). The risk of breast cancer independently increased with the presence of benign breast disease and with the increase in breast density (p for interaction = 0.84). Women with benign breast disease and extremely dense breasts had a threefold elevated risk of breast cancer compared with those with scattered fibroglandular density and without benign breast disease (hazard ratio [HR] = 3.07; 95%CI = 2.01-4.68). Heterogeneous density and benign breast disease was associated with nearly a 2.5 elevated risk (HR = 2.48; 95%CI = 1.66-3.70). Those with extremely dense breast without a benign breast disease had a 2.27 increased risk (95%CI = 2.07-2.49). CONCLUSIONS: Women with benign breast disease had an elevated risk for over 15 years independently of their breast density category. Women with benign breast disease and dense breasts are at high risk for future breast cancer. KEY POINTS: • Benign breast disease and breast density were independently associated with breast cancer. • Women with benign breast disease had an elevated risk for up to 15 years independently of their mammographic density category.


Assuntos
Neoplasias da Mama , Doença da Mama Fibrocística , Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Feminino , Humanos , Mamografia , Fatores de Risco
8.
Breast ; 54: 343-348, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33023825

RESUMO

INTRODUCTION: We aimed to assess differences in breast cancer risk across benign breast disease diagnosed at prevalent or incident screens. MATERIALS AND METHODS: We conducted a retrospective cohort study with data from 629,087 women participating in a long-standing population-based breast cancer screening program in Spain. Each benign breast disease was classified as non-proliferative, proliferative without atypia, or proliferative with atypia, and whether it was diagnosed in a prevalent or incident screen. We used partly conditional Cox hazard regression to estimate the adjusted hazard ratios of the risk of breast cancer. RESULTS: Compared with women without benign breast disease, the risk of breast cancer was significantly higher (p-value = 0.005) in women with benign breast disease diagnosed in an incident screen (aHR, 2.67; 95%CI: 2.24-3.19) than in those with benign breast disease diagnosed in a prevalent screen (aHR, 1.87; 95%CI: 1.57-2.24). The highest risk was found in women with a proliferative benign breast disease with atypia (aHR, 4.35; 95%CI: 2.09-9.08, and 3.35; 95%CI: 1.51-7.40 for those diagnosed at incident and prevalent screens, respectively), while the lowest was found in women with non-proliferative benign breast disease (aHR, 2.39; 95%CI: 1.95-2.93, and 1.63; 95%CI: 1.32-2.02 for those diagnosed at incident and prevalent screens, respectively). CONCLUSION: Our study showed that the risk of breast cancer conferred by a benign breast disease differed according to type of screen (prevalent or incident). To our knowledge, this is the first study to analyse the impact of the screening type on benign breast disease prognosis.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/epidemiologia , Detecção Precoce de Câncer/estatística & dados numéricos , Doença da Mama Fibrocística/diagnóstico por imagem , Mamografia/estatística & dados numéricos , Idoso , Neoplasias da Mama/etiologia , Detecção Precoce de Câncer/métodos , Feminino , Doença da Mama Fibrocística/complicações , Humanos , Incidência , Mamografia/métodos , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Medição de Risco/métodos , Fatores de Risco , Espanha/epidemiologia
9.
J Obstet Gynaecol Res ; 44(2): 331-336, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29027318

RESUMO

AIM: We investigated if imaging and pathology features could help to identify a high axillary tumor burden (ATB) in breast cancer patients, in order to individualize decisions on axillary lymph node (ALN) dissection (ALND). METHODS: We retrospectively analyzed patients primarily treated with surgery in our unit between 2011 and 2014. We divided the patients in two groups: low ATB (LATB) if ≤ 2 ALN were infiltrated and high ATB (HATB) if > 2 ALN were infiltrated. RESULTS: Data of 105 patients was included in the study. Axillary ultrasound (AUS) features associated with HATB were any sign of ALN infiltration (76 vs 24%, P = 0.027) and > 2 suspicious ALNs (73% vs 27%, P = 0.018); however, when AUS revealed ≤ 2 suspicious ALNs, 39% of these patients had HATB. Any sign of ALN infiltration on magnetic resonance imaging was associated with HATB (48% vs 52%, P = 0.031). Positive preoperative ALN cytology or biopsy was associated with HATB (53% vs 47%, P = 0.008), while p53 positivity (80% vs 20%) and high histological grade (68% vs. 32%) correlated with LATB (P = 0.05 and P = 0.02, respectively). In multivariate analysis, only positive preoperative ALN cytology or biopsy was associated with HATB (P = 0.038). CONCLUSIONS: AUS was useful for detecting HATB but was not as effective in patients with LATB. Proving axillary infiltration with AUS-directed cytology or biopsy is the most effective method to predict HATB.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Adulto , Idoso , Axila/diagnóstico por imagem , Axila/patologia , Neoplasias da Mama/patologia , Citodiagnóstico , Feminino , Humanos , Linfonodos/patologia , Metástase Linfática/patologia , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Retrospectivos , Carga Tumoral , Ultrassonografia
10.
Appl Spectrosc ; 70(7): 1128-36, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27279504

RESUMO

This study applied a classic method involving Raman spectroscopy and the use of Stokes and anti-Stokes peaks to measure the temperature of TiO2 thin films found in dye-sensitized solar cells (DSSCs). In addition, three mathematical formulae were used and analyzed to estimate the increase in temperature generated solely by the effect of the radiation. The tests and calculations performed showed an increase in the temperature of the TiO2 film. That is, the films were heated by the radiation they were exposed to. A temperature increase of up to 30 K was detected for the sample with a single layer of TiO2, and over 40 K for the sample with three layers for the highest radiation powers used, and greater increases in temperature were observed in the thicker films.

11.
Phys Chem Chem Phys ; 17(37): 23886-96, 2015 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-26308377

RESUMO

This paper presents the synthesis of organic-inorganic hybrid perovskite CH3NH3Pb1-xCdxI3. The effect of incorporating Cd(2+) or Pb(2+) on the stability of the perovskite structure was analysed from a theoretical and experimental viewpoint. The XRD results showed that the tetragonal perovskite structure was formed for x values of up to 0.5, which seems to indicate that the presence of a considerable amount of Pb(2+) is necessary to stabilise the structure. In turn, UV-Vis spectroscopy showed how the presence of Cd(2+) led to a reduction in the optical band gap of the perovskite structure of up to 9% for CH3NH3Pb0.5Cd0.5I3 with regard to the MAPbI3 structure. Moreover, periodic-DFT calculations were performed to understand the effect of the increased concentration of Cd on the structural and electronic properties of MAPbI3 perovskites. The analysis of both the ELF and the non-covalent interaction (NCI) index show the important role played by the Pb(2+) ions in stabilizing this kind of hybrid perovskite structures. Finally, the DOS analysis confirmed the experimental results obtained using UV-Vis spectroscopy. The theoretical band gap values decreased as the concentration of Cd increased.

12.
Nanoscale ; 7(14): 6216-29, 2015 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-25779372

RESUMO

This paper presents the synthesis of the organic-inorganic hybrid perovskite, CH3NH3PbI3, doped in the Pb(2+) position with Sn(2+), Sr(2+), Cd(2+) and Ca(2+). The incorporation of the dopants into the crystalline structure was analysed, observing how the characteristics of the dopant affected properties such as the crystalline phase, emission and optical properties. XRD showed how doping with Sn(2+), Sr(2+) and Cd(2+) did not modify the normal tetragonal phase. When doping with Ca(2+), the cubic phase was obtained. Moreover, DR-UV-Vis spectroscopy showed how the band gap decreased with the dopants, the values following the trend Sr(2+) < Cd(2+) < Ca(2+) < CH3NH3PbI3 ≈ Sn(2+). The biggest decrease was generated by Sr(2+), which reduced the CH3NH3PbI3 value by 4.5%. In turn, cathodoluminescence (CL) measurements confirmed the band gap obtained. Periodic-DFT calculations were performed to understand the experimental structures. The DOS analysis confirmed the experimental results obtained using UV-Vis spectroscopy, with the values calculated following the trend Sn(2+) ≈ Pb(2+) > Cd(2+) > Sr(2+) for the tetragonal structure and Pb(2+) > Ca(2+) for the cubic phase. The electron localization function (ELF) analysis showed similar electron localizations for undoped and Sn(2+)-doped tetragonal structures, which were different from those doped with Sr(2+) and Cd(2+). Furthermore, when Cd(2+) was incorporated, the Cd-I interaction was strengthened. For Ca(2+) doping, the Ca-I interaction had a greater ionic nature than Cd-I. Finally, an analysis based on the non-covalent interaction (NCI) index is presented to determine the weak-type interactions of the CH3NH3 groups with the dopant and I atoms. To our knowledge, this kind of analysis with these hybrid systems has not been performed previously.

13.
Chemphyschem ; 15(11): 2267-80, 2014 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-24840394

RESUMO

This study presents the experimental and theoretical study of highly internally Al-doped TiO2 nanoparticles. Two synthesis methods were used and detailed characterization was performed. There were differences in the doping and the crystallinity, but the nanoparticles synthesized with the different methods share common features. Anatase to rutile transformation occurred at higher temperatures with Al doping. X-ray photoelectron spectroscopy showed the generation of oxygen vacancies, which is an interesting feature in photocatalysis. In turn, the band-gap energy and the valence band did not change appreciably. Periodic density functional calculations were performed to model the experimentally doped structures, the formation of the oxygen vacancies, and the band gap. Calculation of the density of states confirmed the experimental band-gap energies. The theoretical results confirmed the presence of Ti(4+) and Al(3+) . The charge density study and electron localization function analysis indicated that the inclusion of Al in the anatase structure resulted in a strengthening of the TiO bonds around the vacancy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA