Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Cancers (Basel) ; 16(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38893193

RESUMO

HERMES is a phase II trial of MRI-guided daily-adaptive radiotherapy (MRIgART) randomising men with localised prostate cancer to either 2-fractions of SBRT with a boost to the tumour or 5-fraction SBRT. In the context of this highly innovative regime the dose delivered must be carefully considered. The first ten patients recruited to HERMES were analysed in order to establish the dose received by the targets and organs at risk (OARS) in the context of intrafraction motion. A regression analysis was performed to measure how the volume of air within the rectum might further impact rectal dose secondary to the electron return effect (ERE). One hundred percent of CTV target objectives were achieved on the MRI taken prior to beam-on-time. The post-delivery MRI showed that high-dose CTV coverage was achieved in 90% of sub-fractions (each fraction is delivered in two sub-fractions) in the 2-fraction cohort and in 88% of fractions the 5-fraction cohort. Rectal D1 cm3 was the most exceeded constraint; three patients exceeded the D1 cm3 < 20.8 Gy in the 2-fraction cohort and one patient exceeded the D1 cm3 < 36 Gy in the 5-fraction cohort. The volume of rectal gas within 1 cm of the prostate was directly proportional to the increase in rectal D1 cm3, with a strong (R = 0.69) and very strong (R = 0.90) correlation in the 2-fraction and 5-fraction cohort respectively. Dose delivery specified in HERMES is feasible, although for some patients delivered doses to both target and OARs may vary from those planned.

2.
Front Oncol ; 14: 1379596, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38894866

RESUMO

Introduction: We aimed to establish if stereotactic body radiotherapy to the prostate can be delivered safely using reduced clinical target volume (CTV) to planning target volume (PTV) margins on the 1.5T MR-Linac (MRL) (Elekta, Stockholm, Sweden), in the absence of gating. Methods: Cine images taken in 3 orthogonal planes during the delivery of prostate SBRT with 36.25 Gray (Gy) in 5 fractions on the MRL were analysed. Using the data from 20 patients, the percentage of radiotherapy (RT) delivery time where the prostate position moved beyond 1, 2, 3, 4 and 5 mm in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) and any direction was calculated. Results: The prostate moved less than 3 mm in any direction for 90% of the monitoring period in 95% of patients. On a per-fraction basis, 93% of fractions displayed motion in all directions within 3 mm for 90% of the fraction delivery time. Recurring motion patterns were observed showing that the prostate moved with shallow drift (most common), transient excursions and persistent excursions during treatment. Conclusion: A 3 mm CTV-PTV margin is safe to use for the treatment of 5 fraction prostate SBRT on the MRL, without gating. In the context of gating this work suggests that treatment time will not be extensively lengthened when an appropriate gating window is applied.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38831996

RESUMO

Technological advances in radiation therapy impact on the role and scope of practice of the radiation therapist. The European Society of Radiotherapy and Oncology (ESTRO) recently held two workshops on this topic and this position paper reflects the outcome of this workshop, which included radiation therapists from all global regions. Workflows, quality assurance, research, IGRT and ART as well as clinical decision making are the areas of radiation therapist practice that will be highly influenced by advancing technology in the near future. This position paper captures the opportunities that this will bring to the radiation therapist profession, to the practice of radiation therapy and ultimately to patient care.

4.
Adv Radiat Oncol ; 9(6): 101490, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38681895

RESUMO

Purpose: Swallow-related motion of the larynx is most significant in the cranio-caudal directions and of` short duration. Conventional target definition for radical radiation therapy includes coverage of the whole larynx. This study longitudinally examined respiration- and swallow-related laryngeal motions using cine-magnetic resonance imaging. We further analyzed the dosimetry to organs at risk by comparing 3D-conformal radiation therapy (3D-CRT), volumetric modulated arc therapy (VMAT), and intensity modulated radiation therapy (IMRT) techniques. Methods: Fifteen patients with T1-2 N0 glottic squamous cell carcinomas were prospectively recruited for up to 3 cine-MRI scans on the Elekta Unity MR-Linear accelerator, at the beginning, middle, and end of a course of radical radiation therapy. Swallow frequency and motion of the hyoid bone, cricoid and thyroid cartilages, and vocal cords were recorded during swallow and rest. Adapted treatment volumes consisted of gross tumor volume + 0.5-1 cm to a clinical target volume with an additional internal target volume (ITV) for personalized resting-motion. Swallow-related motion was deemed infrequent and was not accounted for in the ITV. We compared radiation therapy plans for 3D-CRT (whole larynx), VMAT (whole larynx), and VMAT and IMRT (ITV for resting motion). Results: Resting- and swallow-related motions were most prominent in the cranio-caudal plane. There were no significant changes in the magnitude of motion over the course of radiation therapy. There was a trend of a progressive reduction in the frequency of swallow. Treatment of partial larynx volumes with intensity modulated methods significantly reduced the dose to carotid arteries, compared with treatment of whole larynx volumes. Robustness analysis demonstrated that when accounting for intrafraction swallow, the total dose delivered to the ITV/planning target volume was maintained at above 95%. Conclusions: Swallow-related motions are infrequent and accounting for resting motion in an ITV is sufficient. VMAT/IMRT techniques that treat more conformal targets can significantly spare critical organs at risk such as the carotid arteries and thyroid gland, potentially reducing the risk of carotid artery stenosis-related complications and other long-term complications.

5.
Int J Radiat Oncol Biol Phys ; 118(3): 682-687, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37776979

RESUMO

PURPOSE: Ultrahypofractionated radiation therapy (UHRT) is an effective treatment for localized prostate cancer with an acceptable toxicity profile; boosting the visible intraprostatic tumor has been shown to improve biochemical disease-free survival with no significant effect on genitourinary (GU) and gastrointestinal (GI) toxicity. METHODS AND MATERIALS: HERMES is a single-center noncomparative randomized phase 2 trial in men with intermediate or lower high risk prostate cancer. Patients were allocated (1:1) to 36.25 Gy in 5 fractions over 2 weeks or 24 Gy in 2 fractions over 8 days with an integrated boost to the magnetic resonance imaging (MRI) visible tumor of 27 Gy in 2 fractions. A minimization algorithm with a random element with risk group as a balancing factor was used for participant randomization. Treatment was delivered on the Unity MR-Linac (Elekta AB) with daily online adaption. The primary endpoint was acute GU Common Terminology Criteria for Adverse Events version 5.0 toxicity with the aim of excluding a doubling of the rate of acute grade 2+ GU toxicity seen in PACE. Analysis was by treatment received and included all participants who received at least 1 fraction of study treatment. This interim analysis was prespecified (stage 1 of a 2-stage Simon design) for when 10 participants in each treatment group had completed the acute toxicity monitoring period (12 weeks after radiation therapy). RESULTS: Acute grade 2 GU toxicity was reported in 1 (10%) patient in the 5-fraction group and 2 (20%) patients in the 2-fraction group. No grade 3+ GU toxicities were reported. CONCLUSIONS: At this interim analysis, the rate of GU toxicity in the 2-fraction and 5-fraction treatment groups was found to be below the prespecified threshold (5/10 grade 2+) and continuation of the study to complete recruitment of 23 participants per group was recommended.


Assuntos
Gastroenteropatias , Neoplasias da Próstata , Humanos , Masculino , Imageamento por Ressonância Magnética , Pelve , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Sistema Urogenital/efeitos da radiação , Ensaios Clínicos Controlados Aleatórios como Assunto , Ensaios Clínicos Fase II como Assunto
6.
Front Endocrinol (Lausanne) ; 14: 1231043, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38027197

RESUMO

Congenital hyperinsulinism (CHI) is a condition characterised by severe and recurrent hypoglycaemia in infants and young children caused by inappropriate insulin over-secretion. CHI is of heterogeneous aetiology with a significant genetic component and is often unresponsive to standard medical therapy options. The treatment of CHI can be multifaceted and complex, requiring multidisciplinary input. It is important to manage hypoglycaemia in CHI promptly as the risk of long-term neurodisability arising from neuroglycopaenia is high. The UK CHI consensus on the practice and management of CHI was developed to optimise and harmonise clinical management of patients in centres specialising in CHI as well as in non-specialist centres engaged in collaborative, networked models of care. Using current best practice and a consensus approach, it provides guidance and practical advice in the domains of diagnosis, clinical assessment and treatment to mitigate hypoglycaemia risk and improve long term outcomes for health and well-being.


Assuntos
Hiperinsulinismo Congênito , Criança , Lactente , Humanos , Pré-Escolar , Consenso , Hiperinsulinismo Congênito/diagnóstico , Hiperinsulinismo Congênito/genética , Hiperinsulinismo Congênito/terapia , Pancreatectomia , Reino Unido
7.
Phys Imaging Radiat Oncol ; 27: 100481, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37655122

RESUMO

Hybrid systems that combine Magnetic Resonance Imaging (MRI) and linear accelerators are available clinically to guide and adapt radiotherapy. Vendor-approved MRI sequences are provided, however alternative sequences may offer advantages. The aim of this study was to develop a systematic approach for non-vendor sequence evaluation, to determine safety, accuracy and overall clinical application of two potential sequences for bladder cancer MRI guided radiotherapy. Non-vendor sequences underwent and passed clinical image qualitative review, phantom quality assurance, and radiotherapy planning assessments. Volunteer workflow tests showed the potential for one sequence to reduce workflow time by 27% compared to the standard vendor sequence.

8.
Br J Radiol ; 96(1146): 20220852, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37001054

RESUMO

OBJECTIVES: To measure the magnitude of intra-fraction prostate motion (IFPM) during stereotactic radiotherapy (SBRT) delivered without intra-fraction tracking.To assess if current margins adequately cover IFPM.To derive margins using new guidelines. METHODS: IFPM was determined in 20 patients receiving 36.25 Gy in 5 fractions using 97 pairs of pre- and post-treatment cone beam CT (CBCT) scans. Correlation of time between CBCT acquisitions and motion was determined. The magnitude of IFPM was compared to current margins (6 mm isotropic, 3 mm posterior). Margins were calculated using IFPM alone and updated guidelines. RESULTS: The averaged 3D root mean square IFPM was 2.5 mm (4.2 mm). Independent prostate motion was predominantly posterior (70%) and inferior (63%). There was weak correlation between posterior (ρ = 0.38) and inferior (ρ = 0.36) IFPM and time. IFPM greater than current margins occurred in 8 of 97 fractions, six in the posterior direction. Margins were ≤3.5 mm using IFPM alone and ≤3.3 mm Left 3.5 mm Right, 7.0 mm inferior, 3.7 mm superior, 4.4 mm anterior and 3.3 mm posterior using new guidelines, compensating for motion in 92% of fractions. CONCLUSIONS: Our current SBRT margins account for 92% of IFPM, predominantly posterior and inferior. Although updated guidelines suggest an increase in margins inferiorly, any increase must be balanced against the possibility of increased toxicity, particularly if biochemical control and side-effects are favourable with current practice. ADVANCES IN KNOWLEDGE: The difference between current clinical margins and those determined using updated guidance is demonstrated. The implications must be considered against clinical outcomes.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Radioterapia Guiada por Imagem , Masculino , Humanos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Incerteza , Movimento (Física) , Tomografia Computadorizada de Feixe Cônico , Planejamento da Radioterapia Assistida por Computador
9.
Artigo em Inglês | MEDLINE | ID: mdl-36654720

RESUMO

The implementation of MRI-guided online adaptive radiotherapy has enabled extension of therapeutic radiographers' roles to include contouring. An offline interobserver variability study compared five radiographers' and five clinicians' contours on 10 MRIs acquired on a MR-Linac from 10 patients. All contours were compared to a "gold standard" created from an average of clinicians' contours. The median (range) DSC of radiographers' and clinicians' contours compared to the "gold standard" was 0.91 (0.86-0.96), and 0.93 (0.88-0.97) respectively illustrating non-inferiority of the radiographers' contours to the clinicians. There was no significant difference in HD, MDA or volume size between the groups.

10.
Radiother Oncol ; 180: 109457, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36608770

RESUMO

BACKGROUND AND PURPOSE: The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers' roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. MATERIALS AND METHODS: 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. RESULTS: Comparison of the radiographers' and clinicians' contours resulted in a median (range) DSC of 0.92 (0.86 - 0.99), median (range) MDA of 0.98 mm (0.2-1.7) and median (range) HD of 6.3 mm (2.5-11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians' offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88-1.0), median (range) MDA was 0.8 mm (0.04-1.18) and HD was 5.15 mm (2.09-8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians' offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. CONCLUSION: Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Masculino , Humanos , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Glândulas Seminais , Pelve , Radioterapia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
11.
Pract Radiat Oncol ; 13(2): 132-147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36481683

RESUMO

PURPOSE: Radiation therapy is the key treatment for locally advanced cervical cancer. Organ motion presents a challenge to accurate targeting of external beam radiation therapy. The plan-of-the-day (PotD) adaptive approach is therefore an attractive option. We present our experience and the procedural steps required to implement PotD for cervix cancer. METHODS AND MATERIALS: We reviewed relevant studies on organ motion and adaptive radiation therapy identified through a literature search and cross referencing. These included 10 dosimetric and 3 quality of life studies directly assessing the PotD approach to radiation therapy in cervix cancer. RESULTS: Studies show improvements in target coverage and reduction of dose received by normal tissues and suggest improved toxicity. Clinical implementation of PotD has been slow because of a number of difficulties and uncertainties, which we discuss with the aim of helping teams to implement PotD at their center. CONCLUSIONS: The PotD approach improves dosimetry and may improve toxicity. We describe a framework to assist with practical implementation.


Assuntos
Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Qualidade de Vida , Colo do Útero , Dosagem Radioterapêutica
12.
Clin Transl Radiat Oncol ; 30: 31-37, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34307911

RESUMO

INTRODUCTION: With the implementation of new radiotherapy technology, it is imperative that patient experience is investigated alongside efficacy and outcomes. This paper presents the development of a specifically designed validated questionnaire and a first report of international multi-institutional preliminary patient experience of MRI-guided adaptive radiotherapy (MRgART) on the 1.5 T MR-Linac (MRL). METHODS: A patient experience questionnaire was developed and validated before being distributed to the Elekta MRL Consortium, to gather first patient-reported experience from participating centres worldwide. The final version of the questionnaire contains 18 questions covering a range of themes and was scored on a Likert scale of 0-3. Responses were post-processed so that a score of 0 represents a negative response and 3 represents the most favourable response. These results were analysed for patient-reported experience of treatment on the MRL. Results were also analysed for internal consistency of the questionnaire using Chronbach's Alpha and the questionnaire contents were validated for relevance using content validity indexes (CVI). RESULTS: 170 responses were received from five centres, representing patients with a wide range of tumour treatment sites from four different countries. MRgART was well tolerated with an 84% favourable response across all questions and respondents. When analysed by theme, all reported the highest percentage of results in the favourable categories (2 and 3). Internal consistency in the questionnaire was high (Cronbach's α = 0.8) and the item-level CVI for each question was 0.78 or above and the Scale-level CVI was 0.93, representing relevant content. CONCLUSION: The developed questionnaire has been validated as relevant and appropriate for use in reporting experience of patients undergoing treatment on the MRL. The overall patient-reported experience and satisfaction from multiple centres within the Elekta MRL Consortium was consistently high. These results can reinforce user confidence in continuing to expand and develop MRL use in adaptive radiotherapy.

13.
Int J Radiat Oncol Biol Phys ; 104(3): 685-693, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30872145

RESUMO

PURPOSE: Adaptive radiation therapy strategies could account for interfractional uterine motion observed in patients with cervix cancer, but the current cone beam computed tomography (CBCT)-based treatment workflow is limited by poor soft-tissue contrast. The goal of the present study was to determine if ultrasound (US) could be used to improve visualization of the uterus, either as a single modality or in combination with CBCT. METHODS AND MATERIALS: Interobserver uterine contour agreement and confidence were compared on 40 corresponding CBCT, US, and CBCT-US-fused images from 11 patients with cervix cancer. Contour agreement was measured using the Dice similarity coefficient (DSC) and mean contour-to-contour distance (MCCD). Observers rated their contour confidence on a scale from 1 to 10. Pairwise Wilcoxon signed-rank tests were used to measure differences in contour agreement and confidence. RESULTS: CBCT-US fused images had significantly better contour agreement and confidence than either individual modality (P < .05), with median (interquartile range [IQR]) values of 0.84 (0.11), 1.26 (0.23) mm, and 7 (2) for the DSC, MCCD, and observer confidence ratings, respectively. Contour agreement was similar between US and CBCT, with median (IQR) DSCs of 0.81 (0.17) and 0.82 (0.14) and MCCDs of 1.75 (1.15) mm and 1.62 (0.74) mm. Observers were significantly more confident in their US-based contours than in their CBCT-based contours (P < .05), with median (IQR) confidence ratings of 7 (2.75) versus 5 (4). CONCLUSIONS: CBCT and US are complementary and improve uterine segmentation precision when combined. Observers could localize the uterus with a similar precision on independent US and CBCT images.


Assuntos
Colo do Útero/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Imagem Multimodal/métodos , Radioterapia Guiada por Imagem/métodos , Ultrassonografia , Neoplasias do Colo do Útero/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Planejamento da Radioterapia Assistida por Computador/métodos , Padrões de Referência , Autoimagem , Estatísticas não Paramétricas , Bexiga Urinária/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia
14.
BMC Public Health ; 19(1): 80, 2019 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-30654774

RESUMO

BACKGROUND: Incidence and mortality rates of cervical cancer in Bolivia are the highest in Latin America. Vaginal cell self-sampling can improve screening coverage. Information on common reasons for low screening coverage and preferences for future screening are essential to reduce cervical cancer incidence. We aimed to evaluate the knowledge about human papillomavirus (HPV) and cervical cancer of Bolivian women from urban, peri-urban and rural areas of Cochabamba and to determine their degree of acceptability and confidence towards vaginal HPV self-sampling. In addition, we assessed the impact of self-sampling on cervical cancer screening coverage in a selected peri-urban area. METHODS: We gathered information from women living in urban, peri-urban and rural areas of Cochabamba province in Bolivia using two different structured questionnaires. In Survey1, we collected information from 222 women about their knowledge on HPV and cervical cancer. In Survey 2, the acceptance and confidence towards vaginal HPV self-sampling compared to the physician-sampling was assessed in 221 women. A non-probabilistic stratified sampling by areas was carried out for the two questionnaires. In the third phase of the study, we determined the impact of HPV self-sampling collection on screening coverage in a peri-urban area of Cochabamba. RESULTS: Bolivian women knew little or nothing about cervical cancer and HPV infection in all areas. They all found self-sampling collection easier to perform (86.9 to 93.2%) and more comfortable (79.4 to 83.3%) compared to physician sampling. Sampling accuracy to detect cervical cancer was probably higher in their point of view when it was taken by physician (35.1 to 63.5%). However in rural areas women preferred self-sampling. Accordingly, the campaign of vaginal HPV self-sampling in this peri-urban area increased screening coverage, reaching in three months the annual rate average. CONCLUSIONS: The knowledge about cervical cancer and HPV infection is poor in Bolivia. Despite greater acceptance of the vaginal HPV self-sampling in all areas, women kept greater confidence in the screening performed by the gynecologist although HPV self-sampling improved coverage rate.


Assuntos
Detecção Precoce de Câncer/métodos , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Autocuidado , Manejo de Espécimes/métodos , Neoplasias do Colo do Útero/prevenção & controle , Adulto , Bolívia/epidemiologia , Estudos Transversais , Detecção Precoce de Câncer/estatística & dados numéricos , Feminino , Pesquisas sobre Atenção à Saúde , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Pessoa de Meia-Idade , Papillomaviridae/isolamento & purificação , Infecções por Papillomavirus , Inquéritos e Questionários , Neoplasias do Colo do Útero/epidemiologia , Vagina/virologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA