Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Hernia ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38874659

RESUMO

PURPOSE: To investigate the differences in the visibility and size of abdominal wall hernias in computed tomography (CT) with and without Valsalva maneuver. METHODS: This single-center retrospective study included consecutive patients who underwent abdominal CTs with Valsalva maneuver between January 2018 and January 2022. Inclusion criteria was availability of an additional non-Valsalva CT within 6 months. A combined reference standard including clinical and surgical findings was used. Two independent, blinded radiologists measured the hernia sac size and rated hernia visibility on CTs with and without Valsalva. Differences were tested with a Wilcoxon signed rank test and McNemar's test. RESULTS: The final population included 95 patients (16 women; mean age 46 ± 11.6 years) with 205 hernias. Median hernia sac size on Valsalva CT was 31 mm compared with 24 mm on non-Valsalva CT (p < 0.001). In 73 and 82% of cases, the hernias were better visible on CT with Valsalva as compared to that without. 14 and 17% of hernias were only visible on the Valsalva CT. Hernia visibility on non-Valsalva CT varied according to subtype, with only 0 and 3% of umbilical hernias not being visible compared with 43% of femoral hernias. CONCLUSIONS: Abdominal wall hernias are larger and better visible on Valsalva CT compared with non-Valsalva CT in a significant proportion of patients and some hernias are only visible on the Valsalva CT. Therefore, this method should be preferred for the evaluation of abdominal wall hernias.

3.
Hernia ; 27(5): 1253-1261, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37410196

RESUMO

PURPOSE: Inguinal hernias are mainly diagnosed clinically, but imaging can aid in equivocal cases or for treatment planning. The purpose of this study was to evaluate the diagnostic performance of CT with Valsalva maneuver for the diagnosis and characterization of inguinal hernias. METHODS: This single-center retrospective study reviewed all consecutive Valsalva-CT studies between 2018 and 2019. A composite clinical reference standard including surgery was used. Three blinded, independent readers (readers 1-3) reviewed the CT images and scored the presence and type of inguinal hernia. A fourth reader measured hernia size. Interreader agreement was quantified with Krippendorff's α coefficients. Sensitivity, specificity, and accuracy of Valsalva-CT for the detection of inguinal hernias was computed for each reader. RESULTS: The final study population included 351 patients (99 women) with median age 52.2 years (interquartile range (IQR), 47.2, 68.9). A total of 381 inguinal hernias were present in 221 patients. Sensitivity, specificity, and accuracy were 85.8%, 98.1%, and 91.5% for reader 1, 72.7%, 92.5%, and 81.8% for reader 2, and 68.2%, 96.3%, and 81.1% for reader 3. Hernia neck size was significantly larger in cases correctly detected by all three readers (19.0 mm, IQR 13, 25), compared to those missed by all readers (7.0 mm, IQR, 5, 9; p < 0.001). Interreader agreement was substantial (α = 0.723) for the diagnosis of hernia and moderate (α = 0.522) for the type of hernia. CONCLUSION: Valsalva-CT shows very high specificity and high accuracy for the diagnosis of inguinal hernia. Sensitivity is only moderate which is associated with missed smaller hernias.


Assuntos
Hérnia Inguinal , Humanos , Feminino , Pessoa de Meia-Idade , Hérnia Inguinal/diagnóstico por imagem , Hérnia Inguinal/cirurgia , Estudos Retrospectivos , Manobra de Valsalva , Herniorrafia , Tomografia Computadorizada por Raios X/métodos
4.
J Cardiovasc Comput Tomogr ; 15(2): 161-166, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32798185

RESUMO

PURPOSE: To determine the reliability of subjective and objective quantification of mitral annular calcification (MAC) in elderly patients with severe aortic stenosis, to define quantitative sex- and age-related reference values of MAC, and to correlate quantitative MAC with mitral valve disease. METHODS: In this retrospective, IRB-approved study, we included 559 patients (268 females, median age 81 years, inter-quartile range 77-85 years) with severe aortic stenosis undergoing CT. Four independent readers performed subjective MAC categorization as follows: no, mild, moderate, and severe MAC. Two independent readers performed quantitative evaluation of MAC using the Agatston score method (AgatstonMAC). Mitral valve disease was determined by echocardiography. RESULTS: Subjective MAC categorization showed high inter-reader agreement for no (k â€‹= â€‹0.88) and severe MAC (k â€‹= â€‹0.75), whereas agreement for moderate (k â€‹= â€‹0.59) and mild (k â€‹= â€‹0.45) MAC was moderate. Intra-reader agreement for subjective MAC categorization was substantial (k â€‹= â€‹0.69 and 0.62). Inter- and intra-reader agreement for AgatstonMAC were excellent (ICC â€‹= â€‹0.998 and 0.999, respectively), with minor inconsistencies in MAC involving the left ventricular outflow tract/aortic valve. There were significantly more women than men with MAC (n â€‹= â€‹227, 85% versus n â€‹= â€‹209, 72%; p â€‹< â€‹0.001), with a significantly higher AgatstonMAC (median 597, range 81-2055 versus median 244; range 0-1565; p â€‹< â€‹0.001), particularly in patients ≥85 years of age. AgatstonMAC showed an area-under-the-curve of 0.84 to diagnose mitral stenosis, whereas there was no association of AgatstonMAC with mitral regurgitation (p â€‹> â€‹0.05). CONCLUSIONS: Our study in elderly patients with severe aortic stenosis shows that quantitative MAC scoring is more reliable than subjective MAC assessment. Women show higher AgatstonMAC scores than men, particularly in the elderly population. AgatstonMAC shows high accuracy to diagnose mitral stenosis.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores Sexuais
5.
Int J Cardiol ; 310: 108-115, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31982162

RESUMO

BACKGROUND: Studies indicate no clear impact of intracoronary injection of bone-marrow unselected mononuclear cells (BM-MNC) after acute myocardial infarction (AMI) on left-ventricular function (LVEF). Strain parameters by cardiovascular magnetic resonance (CMR) have been proposed to be more sensitive to functional changes of the heart. The aim of the present study was to assess changes of global longitudinal (GLS) and circumferential strain (GCS) in a group of patients treated with BM-MNC after AMI. METHODS: One-hundred and forty-nine patients with successfully reperfused AMI and LV dysfunction (LVEF<45%) were retrospectively included into this sub-study of the SWISS-AMI multicentre trial. Patients were divided into control (N = 54), early (5-7 days after AMI, N = 51) and late BM-MNC treatment groups (3-4 weeks, N = 44). The endpoint was the change of GLS and GCS as obtained from cine sequences 4 and 12 months after AMI using feature tracking algorithm. RESULTS: In unadjusted analyses, the absolute change of GLS for the early treatment group from baseline to 4 months was 2.5 ± 4.3 (p < 0.01), to 12 months 2.7 ± 5.7% (p = 0.004). For late treatment, it was 1.5 ± 4.0% (p = 0.039, 4 months) and 2.5 ± 5.6% (p = 0.015, 12 months). For controls 0.7 ± 4.7% (p = 0.378), 0.8 ± 3.9% (p = 0.253) respectively. Adjusting for different baseline values, neither an overall treatment effect (both time-points) of BM-MNC nor a treatment time-related (only early or late) effect could be shown for all functional parameters. CONCLUSIONS: Among patients after AMI with successful reperfusion and LV dysfunction, intracoronary infusion of BM-MNC early or late after AMI did not improve global strain parameters at 4- or 12-months follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00355186.


Assuntos
Medula Óssea , Infarto do Miocárdio , Transplante de Medula Óssea , Humanos , Espectroscopia de Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda
6.
J Cardiovasc Comput Tomogr ; 13(2): 92-98, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30665879

RESUMO

BACKGROUND: To investigate whether aortic valve calcification (AVC) scoring performed with different workstation platforms generates comparable and thus software-independent results. METHODS: In this IRB-approved retrospective study, we included 100 consecutive patients with symptomatic aortic stenosis undergoing CT prior to transcatheter aortic valve implantation. Two independent observers performed AVC scoring on non-enhanced images with commercially available software platforms of four vendors (GE, Philips, Siemens, 3mensio). Gender-specific Agatston score cut-off values were applied according to current recommendations to assign patients to different likelihood categories of aortic stenosis (unlikely to very likely). Comparative analysis of Agatston scores between the four platforms were performed by using Kruskal-Wallis analysis, Spearman rank correlation, linear regression analysis, and Bland-Altman analysis. Differences in category assignment were compared using Fisher's exact test and Cohen's kappa. RESULTS: For both observers, each workstation platform produced slightly different numeric AVC Agatston scores, however, without statistical significance (p = 0.96 and p = 0.98). Excellent correlation was found between platforms, with r = 0.991-0.996 (Spearman) and r2 = 0.981-0.992 (regression analysis) for both observers. Bland-Altman analyses revealed small mean differences with narrow limits of agreement between platforms (mean differences: 6 ±â€¯128 to 100 ±â€¯179), for inter-observer (mean differences: 1 ±â€¯43 to 12 ±â€¯70), and intra-observer variability (mean differences: 9 ±â€¯42 to 20 ±â€¯96). Observer 1 assigned 11 (kappa: 0.85-0.97) and observer 2 assigned 10 patients (kappa: 0.88-0.95) to different likelihood groups of severe aortic stenosis with at least one platform. Overall, there was no significant difference of likelihood assignment between platforms (p = 0.98 and p = 1.0, respectively). CONCLUSION: While absolute values differ slightly, common commercially available software platforms produce comparable results for AVC scoring, which indicates software-independence of the method.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
7.
Eur Radiol ; 28(10): 4111-4121, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29713770

RESUMO

OBJECTIVES: We aimed to assess the diagnostic performance of a combined protocol with coronary computed tomography angiography (CCTA) and stress CT perfusion imaging (CTP) in heart transplant patients for comprehensive morphological and functional imaging. METHODS: In this prospective study, 13 patients undergoing routine follow-up 8±6 years after heart transplantation underwent CCTA and dynamic adenosine stress CTP using a third-generation dual-source CT scanner, cardiac magnetic resonance (MR) adenosine stress perfusion imaging at 1.5 T, and catheter coronary angiography. In CCTA stenoses >50% luminal diameter narrowing were noted. Myocardial perfusion deficits were documented in CTP and MR. Quantitative myocardial blood flow (MBF) was calculated with CTP. Left ventricular ejection fraction was determined on cardiac MR cine images. Radiation doses of CT were determined. RESULTS: One of the 13 patients had to be excluded because of severe motion artifacts. CCTA identified three patients with stenosis >50%, which were confirmed with catheter coronary angiography. CTP showed four patients with stress-induced myocardial hypoperfusion, which were confirmed by MR stress perfusion imaging. Quantitative analysis of global MBF showed lower mean values as compared to known reference values (MBF under stress 125.5 ± 34.5 ml/100 ml/min). Average left ventricular ejection fraction was preserved (56 ± 5%). CONCLUSIONS: In heart transplant patients, a comprehensive CT protocol for the assessment of morphology and function including CCTA and CTP showed good concordance to results from MR perfusion imaging and catheter coronary angiography. KEY POINTS: • Stress CT perfusion imaging enables the detection of myocardial ischemia • CT myocardial perfusion imaging can be combined with coronary computed tomography angiography • Combining perfusion and coronary CT imaging is accurate in heart transplant patients • CT myocardial perfusion imaging can be performed at a reasonable radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Transplante de Coração , Imagem de Perfusão do Miocárdio/métodos , Adulto , Idoso , Estenose Coronária/fisiopatologia , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
8.
Clin Radiol ; 71(9): 905-11, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27234434

RESUMO

AIM: To demonstrate the feasibility and accuracy of automatic radiation dose monitoring software for computed tomography (CT) of trauma patients in a clinical setting over time, and to evaluate the potential of radiation dose reduction using iterative reconstruction (IR). MATERIALS AND METHODS: In a time period of 18 months, data from 378 consecutive thoraco-abdominal CT examinations of trauma patients were extracted using automatic radiation dose monitoring software, and patients were split into three cohorts: cohort 1, 64-section CT with filtered back projection, 200 mAs tube current-time product; cohort 2, 128-section CT with IR and identical imaging protocol; cohort 3, 128-section CT with IR, 150 mAs tube current-time product. Radiation dose parameters from the software were compared with the individual patient protocols. Image noise was measured and image quality was semi-quantitatively determined. RESULTS: Automatic extraction of radiation dose metrics was feasible and accurate in all (100%) patients. All CT examinations were of diagnostic quality. There were no differences between cohorts 1 and 2 regarding volume CT dose index (CTDIvol; p=0.62), dose-length product (DLP), and effective dose (ED, both p=0.95), while noise was significantly lower (chest and abdomen, both -38%, p<0.017). Compared to cohort 1, CTDIvol, DLP, and ED in cohort 3 were significantly lower (all -25%, p<0.017), similar to the noise in the chest (-32%) and abdomen (-27%, both p<0.017). Compared to cohort 2, CTDIvol (-28%), DLP, and ED (both -26%) in cohort 3 was significantly lower (all, p<0.017), while noise in the chest (+9%) and abdomen (+18%) was significantly higher (all, p<0.017). CONCLUSION: Automatic radiation dose monitoring software is feasible and accurate, and can be implemented in a clinical setting for evaluating the effects of lowering radiation doses of CT protocols over time.


Assuntos
Exposição à Radiação/análise , Proteção Radiológica/métodos , Radiometria/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Ferimentos e Lesões/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Doses de Radiação , Exposição à Radiação/prevenção & controle , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Interface Usuário-Computador , Adulto Jovem
9.
Int J Cardiol ; 217: 167-73, 2016 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-27183453

RESUMO

BACKGROUND: This study aims to determine whether the quantification of myocardial fibrosis in patients with Fabry disease (FD) and hypertrophic cardiomyopathy (HCM) using a late gadolinium enhancement (LGE) singlebreath-hold three-dimensional (3D) inversion recovery magnetic resonance (MR) imaging sequence is comparable with a clinically established two-dimensional (2D) multi-breath-hold sequence. METHODS: In this retrospective, IRB-approved study, 40 consecutive patients (18 male; mean age 50±17years) with Fabry disease (n=18) and HCM (n=22) underwent MR imaging at 1.5T. Spatial resolution was the same for 3D and 2D images (field-of-view, 350×350mm(2); in-plane-resolution, 1.2×1.2mm(2); section-thickness, 8mm). Datasets were analyzed for subjective image quality; myocardial and fibrotic mass, and total fibrotic tissue percentage were quantified. RESULTS: There was no significant difference in subjective image quality between 3D and 2D acquisitions (P=0.1 and P=0.3) for either disease. In patients with Fabry disease there were no significant differences between 3D and 2D acquisitions for myocardial mass (P=0.55), fibrous tissue mass (P=0.89), and total fibrous percentage (P=0.67), with good agreement between acquisitions according to Bland-Altman analyses. In patients with HCM there were also no significant differences between acquisitions for myocardial mass (P=0.48), fibrous tissue mass (P=0.56), and total fibrous percentage (P=0.67), with good agreement according to Bland-Altman analyses. Acquisition time was significantly shorter for 3D (25±5s) as compared to the 2D sequence (349±62s, P<0.001). CONCLUSIONS: In patients with Fabry disease and HCM, 3D LGE imaging provides equivalent diagnostic information in regard to quantification of myocardial fibrosis as compared with a standard 2D sequence, but at superior acquisition speed.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Doença de Fabry/diagnóstico por imagem , Gadolínio/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
10.
Eur J Radiol ; 85(2): 360-5, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26781141

RESUMO

PURPOSE: To compare prospectively, in patients undergoing chest computed tomography (CT) for pulmonary-nodules or infection, image-quality and accuracy of standard dose (SD) and reduced dose (RD) CT with tin-filtration. MATERIAL AND METHODS: This IRB-approved study included 100 consecutive patients (36 female;median age 56 years) referred for follow-up of pulmonary-nodules (n=43) or suspicion of infection (n=57) undergoing single-energy CT with SD and RD using tin-filtration at 100 kVp (CTDIvol 2.47 mGy and 0.07 mGy, respectively). Images were reconstructed with advanced modeled iterative reconstruction (ADMIRE) at strength 3 and 5. Image-noise was measured. Two independent readers evaluated nodules and pulmonary-infection. SD CT served as reference standard. RESULTS: No significant difference was found in noise between RD with ADMIRE5 and SD with ADMIRE3 (118HU ± 14 vs. 120HU ± 17; p=0.08). Sensitivity for detection of atelectasis and interstitial lung changes was higher in images reconstructed with ADMIRE5 (93% and 88%; respectively) than in those reconstructed with ADIMRE3 (77% and 78%; respectively). Sensitivity for detection of consolidations was 90% for ADMIRE3 and 89% for ADMIRE5. Sensitivity for nodule detection was 71% for ADMIRE3 and 81% for ADMIRE5. Specificity for detection of atelectasis and interstitial lung changes was 99% and 96% with ADMIRE5 and 99% and 96% with ADMIRE3. Specificity for detection of consolidations was 99% for ADMIRE3 and 5. Specificity for detection of nodules was 87% for both ADMIRE3 and 5. CONCLUSION: Chest CT with a radiation dose equivalent to conventional radiography is feasible and allows for detection of pulmonary infection with high sensitivity, whereas the accuracy for detecting nodules is only moderate.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Doses de Radiação , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade
11.
Clin Radiol ; 70(11): 1244-51, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26231468

RESUMO

AIM: To investigate the value of advanced virtual monoenergetic image reconstruction (mono-plus) from dual-energy computed tomography (CT) for improving the contrast of CT pulmonary angiography (CTPA). MATERIALS AND METHODS: Forty consecutive patients (25 women, mean 62.5 years, range 28-87 years) underwent 192-section dual-source CTPA with dual-energy CT (90/150 SnkVp) after the administration of 60 ml contrast media (300 mg iodine/ml). Conventional virtual monochromatic images at 60 keV and 17 mono-plus image datasets from 40-190 keV (in 10 keV steps) were reconstructed. Subjective image quality (artefacts, subjective noise) was rated. Attenuation was measured in the pulmonary trunk and in the right lower lobe pulmonary artery; noise was measured in the periscapular musculature. The signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated for each patient and dataset. Comparisons between monochromatic images and mono-plus images were performed by repeated measures analysis of variance (ANOVA) with post-hoc Bonferroni correction. RESULTS: Interreader agreement was good to excellent for subjective image quality (ICC: 0.616-0.889). As compared to conventional 60 keV images, artefacts occurred less (p=0.001) and subjective noise was rated lower (p<0.001) in mono-plus 40 keV images. Noise was lower (p<0.001), and the SNR and CNR in the pulmonary trunk and right lower lobe pulmonary artery were higher (both, p<0.001) in mono-plus 40 keV images compared to conventional monoenergetic 60 keV images. Transient interruption of contrast (TIC) was found in 14/40 (35%) of patients, with subjective contrast being similar 8/40 (20%) or higher 32/40 (80%) in mono-plus 40 keV as compared to conventional monoenergetic 60 keV images. CONCLUSIONS: Compared to conventional virtual monoenergetic imaging, mono-plus images at 40 keV improve the contrast of dual-energy CTPA.


Assuntos
Processamento de Imagem Assistida por Computador/normas , Artéria Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Artefatos , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Iodo , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas
12.
Eur J Radiol ; 84(10): 1879-87, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26194029

RESUMO

PURPOSE: To determine MR-imaging features for the differentiation between hepatocellular carcinoma (HCC) and benign hepatocellular tumors in the non-cirrhotic liver. MATERIAL AND METHODS: 107 consecutive patients without liver cirrhosis (46 male; 45 ± 14 years) who underwent liver resection due to suspicion of HCC were included in this multi-center study. The following imaging features were assessed: lesion diameter and demarcation, satellite-lesions, central-scar, capsule, fat-content, hemorrhage, vein-infiltration and signal-intensity (SI) on native T1-, T2- and dynamic-enhanced T1-weighted images (center versus periphery). In addition, contrast-media (CM) uptake in the liver specific phase was analyzed in a sub-group of 42 patients. RESULTS: Significant differences between HCC (n=55) and benign lesions (n=52) were shown for native T1-, T2- and dynamic-enhanced T1-SI, fat-content, and satellite-lesions (all, P<.05). Independent predictors for HCC were T1-hypointensity (odds-ratio, 4.81), T2-hypo-/hyperintensity (5.07), lack of central tumor-enhancement (3.36), and satellite-lesions (5.78; all P<0.05). Sensitivity and specificity of HCC was 91% and 75% respectively for two out-of four independent predictors, whereas specificity reached 98% for all four predictors. Sub-analysis, showed significant differences in liver specific CM uptake between HCC (n=18) and benign lesions (n=24; P<0.001) and revealed lack of liver specific CM uptake (odds-ratio, 2.7) as additional independent feature for diagnosis of HCC. CONCLUSION: Independent MRI features indicating HCC are T1-hypointensity, T2-hypo- or hyperintensity, lack of central tumor-enhancement, presence of satellite-lesions and lack of liver specific CM-uptake. These features may have the potential to improve the diagnosis of HCC in the non-cirrhotic liver.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adenoma de Células Hepáticas/diagnóstico , Adenoma de Células Hepáticas/patologia , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Meios de Contraste/administração & dosagem , Diagnóstico Diferencial , Feminino , Hiperplasia Nodular Focal do Fígado/diagnóstico , Hiperplasia Nodular Focal do Fígado/patologia , Seguimentos , Gadolínio DTPA/administração & dosagem , Hepatectomia/métodos , Hepatite C/complicações , Humanos , Fígado/patologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
Clin Radiol ; 70(4): 366-72, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25554541

RESUMO

AIM: To compare low-contrast detectability, and qualitative and quantitative image parameters on standard and reduced radiation dose abdominal CT reconstructed with filtered back projection (FBP) and model-based iterative reconstruction (MBIR). MATERIALS AND METHODS: A custom built liver phantom containing 43 lesions was imaged at 120 kVp and four radiation dose levels (100% = 188 mAs, 50%, 25%, and 10%). Image noise and contrast-to-noise ratios (CNR) were assessed. Lesion detection and qualitative image analysis (five-point Likert scale with 1 = worst, 5 = best for confidence) was performed by three independent radiologists. RESULTS: CNR on MBIR images was significantly higher (mean 246%, range 151-383%) and image noise was significantly lower (69%, 59-78%) than on FBP images at the same radiation dose (both p < 0.05). On MBIR 10% images, CNR (3.3 ± 0.3) was significantly higher and noise (15 ± 1HU) significantly lower than on FBP 100% images (2.5 ± 0.1; 21 ± 1 HU). On 100% images, lesion attenuation was significantly lower with MBIR than with FBP (mean difference -2 HU). Low-contrast detectability and qualitative results were similar with MBIR 50% and FBP 100%. CONCLUSION: Low-contrast detectability with MBIR 50% and FBP 100% were equal. Quantitative parameters on even lower dose MBIR images are superior to 100%-dose FBP images. Some attenuation values differ significantly with MBIR compared with FBP.


Assuntos
Fígado/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes
14.
Br J Radiol ; 88(1047): 20140616, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25594105

RESUMO

OBJECTIVE: To determine the number of imaging examinations, radiation dose and the time to complete trauma-related imaging in multiple trauma patients before and after introduction of whole-body CT (WBCT) into early trauma care. METHODS: 120 consecutive patients before and 120 patients after introduction of WBCT into the trauma algorithm of the University Hospital Zurich were compared regarding the number and type of CT, radiography, focused assessment with sonography for trauma (FAST), additional CT examinations (defined as CT of the same body regions after radiography and/or FAST) and the time to complete trauma-related imaging. RESULTS: In the WBCT cohort, significantly more patients underwent CT of the head, neck, chest and abdomen (p < 0.001) than in the non-WBCT cohort, whereas the number of radiographic examinations of the cervical spine, chest and pelvis and of FAST examinations were significantly lower (p < 0.001). There were no significant differences between cohorts regarding the number of radiographic examinations of the upper (p = 0.56) and lower extremities (p = 0.30). We found significantly higher effective doses in the WBCT (29.5 mSv) than in the non-WBCT cohort (15.9 mSv; p < 0.001), but fewer additional CT examinations for completing the work-up were needed in the WBCT cohort (p < 0.001). The time to complete trauma-related imaging was significantly shorter in the WBCT (12 min) than in the non-WBCT cohort (75 min; p < 0.001). CONCLUSION: Including WBCT in the initial work-up of trauma patients results in higher radiation doses, but fewer additional CT examinations are needed, and the time for completing trauma-related imaging is shorter. ADVANCES IN KNOWLEDGE: WBCT in trauma patients is associated with a high radiation dose of 29.5 mSv.


Assuntos
Algoritmos , Diagnóstico Precoce , Traumatismo Múltiplo/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
15.
Pathologe ; 35(1): 83-7, 2014 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-23732632

RESUMO

Thyroid-like follicular carcinoma of the kidney is postulated as a potentially new entity of renal tumor based on nine previously published case reports. This tumor entity is not yet integrated into the classification of tumors of the World Health Organization (WHO). In this article a new case of thyroid-like follicular carcinoma of kidney is described which was incidentally detected at autopsy. The 58-year-old patient died of complications of acute myeloid leukemia after chemotherapy and also had prostatic adenocarcinoma. The renal tumor in the left kidney had a diameter of 3 cm and showed a grey-brown cut surface. Histologically, the tumor presented with a typical thyroid-like microfollicular and macrofollicular structure filled with eosinophilic, colloid-like material with calcification. Immunohistologically the renal tumor was CD 10 positive and negative for thyroid transcription factor 1 (TTF1) and thyroglobulin. A synopsis of the published case reports indicates that thyroid-like follicular carcinoma of the kidney has a low risk of metastasis. More experience with further cases of thyroid-like follicular renal carcinoma is necessary before a recommendation of a separate tumor entity in the next WHO classification is justified.


Assuntos
Adenocarcinoma Folicular/patologia , Carcinoma de Células Renais/patologia , Neoplasias Renais/patologia , Adenocarcinoma/patologia , Adenocarcinoma Folicular/classificação , Biomarcadores Tumorais/análise , Carcinoma de Células Renais/classificação , Humanos , Achados Incidentais , Rim/patologia , Neoplasias Renais/classificação , Leucemia Aguda Bifenotípica/patologia , Leucemia Mieloide Aguda/patologia , Masculino , Pessoa de Meia-Idade , Neoplasias Primárias Múltiplas/classificação , Neoplasias Primárias Múltiplas/patologia , Neprilisina/análise , Proteínas Nucleares/análise , Neoplasias da Próstata/patologia , Tireoglobulina/análise , Fator Nuclear 1 de Tireoide , Fatores de Transcrição/análise
16.
Radiologe ; 53(10): 864-71, 2013 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-24002182

RESUMO

CLINICAL/METHODICAL ISSUE: Cardiac computed tomography (CT) is the first-line modality for coronary assessment. In addition valvular morphology and function can be evaluated. STANDARD RADIOLOGICAL METHODS: The method of choice for the evaluation of cardiac valves is echocardiography, followed by magnetic resonance imaging. METHODICAL INNOVATIONS: Recent technical improvements and advances in temporal resolution allow a detailed anatomical and functional evaluation of the cardiac valves. PERFORMANCE: Cardiac CT provides an excellent image quality of the aortic and mitral valve thus enabling an evaluation of the morphology. In addition, cardiac CT allows an assessment of aortic valve function with respect to the grading of stenosis and regurgitation. ACHIEVEMENTS: Cardiac CT is not considered the first-line modality for the evaluation of cardiac valves; however, beyond coronary assessment CT provides important information on the morphology and function of cardiac valves. PRACTICAL RECOMMENDATIONS: Cardiac CT can be a useful imaging alternative for patients in whom other more commonly used methods, such as echocardiography and magnetic resonance imaging fail to provide the necessary information.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos
17.
Clin Radiol ; 68(2): e79-86, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23219454

RESUMO

AIM: To assess the effect of an automatic tube voltage selection technique on image quality and radiation dose in abdominal computed tomography (CT) angiography of various body sizes. MATERIALS AND METHODS: An abdominal aortic phantom was filled with iodinated contrast medium and placed into three different cylindrical water containers, which simulated a small, intermediate-sized, and large patient. The phantom was scanned with a standard 120 kVp abdominal CT angiography protocol and with an optimized tube voltage protocol that was modulated by an automatic tube voltage technique. The attenuation of the aorta, background, and image noise was measured, and the contrast-to-noise ratio (CNR) was calculated. Three independent readers assessed the overall image quality. RESULTS: The automatic tube voltage technique selected 70 kVp as the optimal tube voltage for the small phantom, 80 kVp for the intermediate phantom, and 100 kVp for the large phantom. Compared to the standard 120 kVp protocol, the automatic tube voltage selection yielded significantly increased CNR values in the small phantom (15.8 versus 19.4, p < 0.001), intermediate phantom (8.4 versus 8.7, p < 0.05), and large phantom (4.3 versus 4.6, p < 0.01). The automatic tube voltage selection resulted in a 55%, 49%, and 39% reduction in the volume CT dose index (CTDI(vol)) in the small, intermediate, and large phantoms, respectively. The subjective overall image quality of the three phantom sizes at different tube voltages ranged between poor and good. CONCLUSION: Compared to a standard 120 kVp abdominal CT angiography protocol, the automatic tube voltage selection substantially reduced the radiation dose without compromising image quality in various simulated patient sizes.


Assuntos
Angiografia/métodos , Aorta Abdominal/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Automação , Tamanho Corporal , Humanos , Lesões por Radiação/prevenção & controle , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Sensibilidade e Especificidade
18.
J Invasive Cardiol ; 24(5): 196-201, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22562911

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) provides information regarding lesion morphology and three-dimensional coronary anatomy incremental to coronary angiography. We addressed the question whether preprocedural CCTA bears potential for guiding percutaneous coronary interventions (PCI). METHODS AND RESULTS: Sixty-six coronary lesions attempted with PCI within 6 months of preprocedural CCTA were retrospectively assessed. Lesion parameters from unenhanced computed tomography (CT) for calcium scoring and CCTA were analyzed and compared with PCI complexity. Complex PCI was defined as use of buddy wire, kissing balloon, necessity of high pressure balloons, or rotablator. Complex PCIs were observed in 32 interventions (48%). Median Agatston score and Hounsfield units were higher in lesions with complex as compared to those with non-complex interventions with 130 (interquartile range, 23-276) vs 29 (0-158; P=.01), and 493 (245-631) vs 341 (68-520 Hounsfield Units; P=.04), respectively. Median local plaque volume and plaque mass were higher in complex PCI with 17 (2-39) vs 5 (0-19.5 mm³; P=.007), and 48 (15-99) vs. 16 (1.5-63 mg hydroxyapatite/mm³; P=.03), respectively. Lesions leading to complex PCI were longer [1.8 (1.2-2.8) vs 1.3 (0.8-1.7) cm; P=.03], and had a higher rate of calcified plaques (23% vs 3%; P=.03). There was a significant correlation between CCTA- and angiography-derived local SYNTAX Scores (P<.001); the CCTA-derived score seems to be predictive for failed and complex PCI (area under curve = 0.75 ± 0.13 and 0.66 ± 0.08, respectively). CONCLUSIONS: Preprocedural lesion assessment by CCTA indicates complexity of PCI. In patients with suspected complex coronary anatomy, prior CCTA adds important information for planning PCI.


Assuntos
Angioplastia Coronária com Balão/métodos , Angiografia Coronária/métodos , Doença das Coronárias/terapia , Tomografia Computadorizada por Raios X/métodos , Idoso , Calcinose/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Placa Aterosclerótica/terapia , Curva ROC , Intensificação de Imagem Radiográfica , Radiografia Intervencionista/métodos , Estudos Retrospectivos
19.
AJNR Am J Neuroradiol ; 33(6): 1014-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22300930

RESUMO

BACKGROUND AND PURPOSE: CT protocols should aim for radiation doses being as low as reasonably achievable. The purpose of our study was to assess the image quality and radiation dose of neck CT at a tube potential of 70 kVp. MATERIALS AND METHODS: Twenty patients (7 female, mean age 51.4 years, age range 19-81 years) underwent contrast-enhanced 64-section CT of the neck at 70 kVp (ATCM, effective tube current-time product 614 eff.mAs, range 467-713 eff.mAs). All 20 patients had a previous neck CT at 120 kVp on the same scanner. Two radiologists assessed image quality and artifacts in the upper, middle, and lower neck. Image noise and attenuation were measured, and the CNR was calculated. Effective radiation dose was calculated. RESULTS: Interobserver agreement regarding image quality of soft tissue for 70-kVp and 120-kVp scans was good to excellent. At 70 kVp, soft tissues were of diagnostic image quality in all scans, whereas the lower cervical spine was not of diagnostic quality in 3 and 4 scans per both readers. No difference was found among 70-kVp and 120-kVp scans for soft tissue image quality in the upper neck, while image quality was significantly better in the middle at 70 kVp (P < .05) and better in the lower third at 120 kVp (P < .05). CNR was significantly higher at 70 kVp in all levels for both readers (P < .001). Effective radiation dose at 70 kVp was significantly lower (0.88 ± 0.2 mSv) than at 120 kVp (1.33 ± 0.2 mSv, P < .001). CONCLUSIONS: CT of the cervical soft tissues at 70 kVp is feasible, provides diagnostic image quality with improved CNR, and reduces radiation dose by approximately 34% compared with a standard protocol at 120 kVp. In contrast, low kVp CT of the lower cervical spine suffers from compromised image quality.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Pescoço/patologia , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA