RESUMO
INTRODUCTION: The intracranial skull-base meningioma is in proximity to multiple critical organs and heterogeneous tissues. Steep dose gradients often result from avoiding critical organs in proton treatment plans. Dose uncertainties arising from setup errors under image-guided radiation therapy are worthy of evaluation. PATIENTS AND METHODS: Fourteen patients with skull-base meningioma were retrospectively identified and planned with proton pencil beam scanning (PBS) single-field uniform dose (SFUD) and multifield optimization (MFO) techniques. The setup uncertainties were assigned a probability model on the basis of prior published data. The impact on the dose distribution from nominal 1-mm and large, less probable setup errors, as well as the cumulative effect, was analyzed. The robustness of SFUD and MFO planning techniques in these scenarios was discussed. RESULTS: The target coverage was reduced and the plan dose hot spot increased by all setup uncertainty scenarios regardless of the planning techniques. For 1 mm nominal shifts, the deviations in clinical target volume (CTV) coverage D99% was -11 ± 52 cGy and -45 ± 147 cGy for SFUD and MFO plans. The setup uncertainties affected the organ at risk (OAR) dose both positively and negatively. The statistical average of the setup uncertainties had <100 cGy impact on the plan qualities for all patients. The cumulative deviations in CTV D95% were 1 ± 34 cGy and -7 ± 18 cGy for SFUD and MFO plans. CONCLUSION: It is important to understand the impact of setup uncertainties on skull-base meningioma, as the tumor target has complex shape and is in proximity to multiple critical organs. Our work evaluated the setup uncertainty based on its probability distribution and evaluated the dosimetric consequences. In general, the SFUD plans demonstrated more robustness than the MFO plans in target coverages and brainstem dose. The probability-weighted overall effect on the dose distribution is small compared to the dosimetric shift during single fraction.
RESUMO
Exposure to heavy-ion radiation during cancer treatment or space travel may cause cognitive detriments that have been associated with changes in neuron morphology and plasticity. Observations in mice of reduced neuronal dendritic complexity have revealed a dependence on radiation quality and absorbed dose, suggesting that microscopic energy deposition plays an important role. In this work we used morphological data for mouse dentate granular cell layer (GCL) neurons and a stochastic model of particle track structure and microscopic energy deposition (ED) to develop a predictive model of high-charge and energy (HZE) particle-induced morphological changes to the complex structures of dendritic arbors. We represented dendrites as cylindrical segments of varying diameter with unit aspect ratios, and developed a fast sampling method to consider the stochastic distribution of ED by δ rays (secondary electrons) around the path of heavy ions, to reduce computational times. We introduce probabilistic models with a small number of parameters to describe the induction of precursor lesions that precede dendritic snipping, denoted as snip sites. Predictions for oxygen (16O, 600 MeV/n) and titanium (48Ti, 600 MeV/n) particles with LET of 16.3 and 129 keV/µm, respectively, are considered. Morphometric parameters to quantify changes in neuron morphology are described, including reduction in total dendritic length, number of branch points and branch numbers. Sholl analysis is applied for single neurons to elucidate dose-dependent reductions in dendritic complexity. We predict important differences in measurements from imaging of tissues from brain slices with single neuron cell observations due to the role of neuron death through both soma apoptosis and excessive dendritic length reduction. To further elucidate the role of track structure, random segment excision (snips) models are introduced and a sensitivity study of the effects of the modes of neuron death in predictions of morphometric parameters is described. An important conclusion of this study is that δ rays play a major role in neuron morphological changes due to the large spatial distribution of damage sites, which results in a reduced dependence on LET, including modest difference between 16O and 48Ti, compared to damages resulting from ED in localized damage sites.
Assuntos
Dendritos/metabolismo , Dendritos/efeitos da radiação , Íons Pesados/efeitos adversos , Hipocampo/citologia , Modelos Biológicos , Animais , Morte Celular/efeitos da radiação , Dano ao DNA , Relação Dose-Resposta à Radiação , Hipocampo/efeitos da radiação , Camundongos , Fatores de TempoRESUMO
Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100µm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch.
Assuntos
Dendritos/efeitos da radiação , Íons Pesados , Modelos Estruturais , Neurônios/efeitos da radiação , Prótons , Simulação por Computador , Radiação Cósmica , Dendritos/patologia , Humanos , Método de Monte Carlo , Neurônios/patologia , Doses de RadiaçãoRESUMO
In this paper, the authors recommend that the dose and dose-rate effectiveness factor used for space radiation risk assessments should be based on a comparison of the biological effects of energetic electrons produced along a cosmic ray particles path in low fluence exposures to high dose-rate gamma-ray exposures of doses of about 1 Gy. Methods to implement this approach are described.
Assuntos
Radiação Cósmica/efeitos adversos , Relação Dose-Resposta à Radiação , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/prevenção & controle , Exposição à Radiação/análise , Radiometria/métodos , Elétrons , Exposição à Radiação/efeitos adversos , Proteção Radiológica/métodos , Eficiência Biológica Relativa , Medição de Risco/métodos , Voo EspacialRESUMO
The prediction of the risks of cancer and other late effects from space radiation exposure carries large uncertainties mostly due to the lack of information on the risks from high charge and energy (HZE) particles and other high linear energy transfer (LET) radiation. In our recent work new methods were used to consider NASA's requirement to protect against the acceptable risk of no more than 3% probability of cancer fatality estimated at the 95% confidence level. Because it is not possible that a zero-level of uncertainty could be achieved, we suggest that an acceptable uncertainty level should be defined in relationship to a probability distribution function (PDF) that only suffers from modest skewness with higher uncertainty allowed for a normal PDF. In this paper, we evaluate PDFs and the number or "safe days" in space, which are defined as the mission length where risk limits are not exceeded, for several mission scenarios at different acceptable levels of uncertainty. In addition, we briefly discuss several important issues in risk assessment including non-cancer effects, the distinct tumor spectra and lethality found in animal experiments for HZE particles compared to background or low LET radiation associated tumors, and the possibility of non-targeted effects (NTE) modifying low dose responses and increasing relative biological effectiveness (RBE) factors for tumor induction. Each of these issues skew uncertainty distributions to higher fatality probabilities with the potential to increase central values of risk estimates in the future. Therefore they will require significant research efforts to support space exploration within acceptable levels of risk and uncertainty.