Strahlenther Onkol ; 200(1): 71-82, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37380796

RESUMO

PURPOSE: The robustness of surface-guided (SG) deep-inspiration breath-hold (DIBH) radiotherapy (RT) for left breast cancer was evaluated by investigating any potential dosimetric effects due to the residual intrafractional motion allowed by the selected beam gating thresholds. The potential reduction of DIBH benefits in terms of organs at risk (OARs) sparing and target coverage was evaluated for conformational (3DCRT) and intensity-modulated radiation therapy (IMRT) techniques. METHODS: A total of 192 fractions of SGRT DIBH left breast 3DCRT treatment for 12 patients were analyzed. For each fraction, the average of the real-time displacement between the isocenter on the daily reference surface and on the live surface ("SGRT shift") during beam-on was evaluated and applied to the original plan isocenter. The dose distribution for the treatment beams with the new isocenter point was then calculated and the total plan dose distribution was obtained by summing the estimated perturbed dose for each fraction. Then, for each patient, the original plan and the perturbed one were compared by means of Wilcoxon test for target coverage and OAR dose-volume histogram (DVH) metrics. A global plan quality score was calculated to assess the overall plan robustness against intrafractional motion of both 3DCRT and IMRT techniques. RESULTS: Target coverage and OAR DVH metrics did not show significant variations between the original and the perturbed plan for the IMRT techniques. 3DCRT plans showed significant variations for the left descending coronary artery (LAD) and the humerus only. However, none of the dose metrics exceeded the mandatory dose constraints for any of the analyzed plans. The global plan quality analysis indicated that both 3DCRT and IMRT techniques were affected by the isocenter shifts in the same way and, generally, the residual isocenter shifts more likely tend to worsen the plan in all cases. CONCLUSION: The DIBH technique proved to be robust against residual intrafractional isocenter shifts allowed by the selected SGRT beam-hold thresholds. Small-volume OARs located near high dose gradients showed significant marginal deteriorations in the perturbed plans with the 3DCRT technique only. Global plan quality was mainly influenced by patient anatomy and treatment beam geometry rather than the technique adopted.


Assuntos
Neoplasias da Mama , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Suspensão da Respiração , Radioterapia Conformacional/métodos , Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco , Neoplasias Unilaterais da Mama/radioterapia
2.
Strahlenther Onkol ; 199(1): 55-66, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36229656

RESUMO

PURPOSE: To compare two left breast cancer patient cohorts (tangential vs. locoregional deep-inspiration breath-hold - DIBH treatment) with different predefined beam gating thresholds and to evaluate their impact on motion management and DIBH stability. METHODS: An SGRT-based clinical workflow was adopted for the DIBH treatment. Intrafractional monitoring was performed by tracking both the respiratory signal and the real-time displacement between the isocenter on the daily reference surface and on the live surface ("SGRT shift"). Beam gating tolerances were 5 mm/4 mm for the SGRT shifts and 5 mm/3 mm for the gating window amplitude for breast tangential and breast + lymph nodes locoregional treatments, respectively. A total of 24 patients, 12 treated with a tangential technique and 12 with a locoregional technique, were evaluated for a total number of 684 fractions. Statistical distributions of SGRT shift and respiratory signal for each treatment fraction, for each patient treatment, and for the two population samples were generated. RESULTS: Lateral cumulative distributions of SGRT shifts for both locoregional and tangential samples were consistent with a null shift, whereas longitudinal and vertical ones were slightly negative (mean values < 1 mm). The distribution of the percentage of beam on time with SGRT shift > 3 mm, > 4 mm, or > 5 mm was extended toward higher values for the tangential sample than for the locoregional sample. The variability in the DIBH respiration signal was significantly greater for the tangential sample. CONCLUSION: Different beam gating thresholds for surface-guided DIBH treatment of left breast cancer can impact motion management and DIBH stability by reducing the frequency of the maximum SGRT shift and increasing respiration signal stability when tighter thresholds are adopted.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/radioterapia , Suspensão da Respiração , Respiração , Movimento (Física) , Mama , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica