2.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38195003

RESUMO

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/terapia , Estudos Retrospectivos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , América do Norte/epidemiologia , Europa (Continente)/epidemiologia
3.
PLoS One ; 18(5): e0286084, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37228068

RESUMO

INTRODUCTION: The characteristics of young adults with out-of-hospital cardiac arrest (OHCA) due to acute coronary syndrome (ACS) has not been well described. The mean age of gulf citizens in ACS registries is 10-15 years younger than their western counterparts, which provided us with a unique opportunity to investigate the characteristics and predictors of OHCA in young adults presenting with ACS. METHODOLOGY: This was a retrospective cohort study using data from 7 prospective ACS registries in the Gulf region. In brief, all registries included consecutive adults who were admitted with ACS. OHCA was defined as cardiac arrest upon presentation (i.e., before admission to the hospital). We described the characteristics of young adults (< 50 years) who had OHCA and performed multivariate logistic regression analysis to assess independent predictors of OHCA. RESULTS: A total of 31,620 ACS patients were included in the study. There were 611 (1.93%) OHCA cases in the whole cohort [188/10,848 (1.73%) in young adults vs 423/20,772 (2.04%) in older adults, p = 0.06]. Young adults were predominantly males presenting with ST-elevation myocardial infarction (STEMI) [182/188 (96.8%) and 172/188 (91.49%), respectively]. OHCA was the sentinel event of coronary artery disease (CAD) in 70% of young adults. STEMI, male sex, and non-smoking status were found to be independent predictors of OHCA [OR = 5.862 (95% CI 2.623-13.096), OR: 4.515 (95% CI 1.085-18.786), and OR = 2.27 (95% CI 1.335-3.86), respectively]. CONCLUSION: We observed a lower prevalence of OHCA in ACS patients in our region as compared to previous literature from other regions. Moreover, OHCA was the sentinel event of CAD in the majority of young adults, who were predominantly males with STEMIs. These findings should help risk-stratify patients with ACS and inform further research into the characteristics of OHCA in young adults.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Parada Cardíaca Extra-Hospitalar , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Masculino , Adulto Jovem , Idoso , Criança , Adolescente , Feminino , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/epidemiologia , Parada Cardíaca Extra-Hospitalar/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Estudos Retrospectivos , Estudos Prospectivos , Sistema de Registros
4.
Eur Heart J ; 43(32): 3041-3052, 2022 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-35766180

RESUMO

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) causes ventricular arrhythmias (VAs) and sudden cardiac death (SCD). In 2019, a risk prediction model that estimates the 5-year risk of incident VAs in ARVC was developed (ARVCrisk.com). This study aimed to externally validate this prediction model in a large international multicentre cohort and to compare its performance with the risk factor approach recommended for implantable cardioverter-defibrillator (ICD) use by published guidelines and expert consensus. METHODS AND RESULTS: In a retrospective cohort of 429 individuals from 29 centres in North America and Europe, 103 (24%) experienced sustained VA during a median follow-up of 5.02 (2.05-7.90) years following diagnosis of ARVC. External validation yielded good discrimination [C-index of 0.70 (95% confidence interval-CI 0.65-0.75)] and calibration slope of 1.01 (95% CI 0.99-1.03). Compared with the three published consensus-based decision algorithms for ICD use in ARVC (Heart Rhythm Society consensus on arrhythmogenic cardiomyopathy, International Task Force consensus statement on the treatment of ARVC, and American Heart Association guidelines for VA and SCD), the risk calculator performed better with a superior net clinical benefit below risk threshold of 35%. CONCLUSION: Using a large independent cohort of patients, this study shows that the ARVC risk model provides good prognostic information and outperforms other published decision algorithms for ICD use. These findings support the use of the model to facilitate shared decision making regarding ICD implantation in the primary prevention of SCD in ARVC.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Arritmias Cardíacas/etiologia , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco
5.
JACC Clin Electrophysiol ; 5(9): 1059-1067, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31537335

RESUMO

OBJECTIVES: This study sought to examine outcomes of our approach to managing a large cohort of patients with Sprint Fidelis (Medtronic, Minneapolis, Minnesota) leads. BACKGROUND: The optimal management approach for patients with leads under advisory is unknown. Concerns regarding the risk of device infection and complications associated with delaying lead extraction have recently been suggested to argue against abandoning leads under advisory. METHODS: All patients with a Sprint Fidelis lead implanted at our institute were included. Lead management options were discussed with patients who presented for device surgery at the time of device upgrade, lead fracture, or elective replacement indicator. Implantation of a new lead with abandonment of the Sprint Fidelis lead was the recommended strategy. Patients were subsequently followed at the device clinic at 6-month intervals and were enrolled prospectively in a longitudinal registry. RESULTS: A total of 520 patients had Sprint Fidelis leads implanted between December 2003 and October 2007 at the study center; 217 patients underwent lead replacement (213 underwent a lead abandonment strategy and 4 underwent a lead extraction strategy). Mean follow-up after lead replacement was 55 ± 33 months. In patients undergoing lead abandonment, 10 of 213 (4.7%) had a procedural complication and 3 of 213 (1.4%) developed subsequent device infection requiring system extraction. CONCLUSIONS: In patients with a Sprint Fidelis lead, implanting a new lead without prophylactic extraction may be a feasible and safe strategy but requires longer follow-up.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Idoso , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/normas , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Remoção de Dispositivo/estatística & dados numéricos , Feminino , Humanos , Masculino , Recall de Dispositivo Médico , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação/estatística & dados numéricos
6.
Echocardiography ; 36(4): 666-670, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30883925

RESUMO

BACKGROUND: There are discrepancies in the quantitative echocardiographic criteria for the right ventricle (RV) between the revised task force criteria (TFC) for Arrhythmogenic Right Ventricular Cardiomyopathy/Dysplasia (ARVC/D) and the guidelines for RV assessment endorsed by American Society of Echocardiography (ASE). Importantly, these criteria do not take into account potential adaptation of the RV to exercise. The goal of this study was to compare the revised TFC quantitative echocardiographic parameters in patients with ARVC/D, athletes and matched controls. METHODS: Echocardiographic parameters of the RV were retrospectively collected in patients who fulfilled the TFC for ARVC/D, an age- matched, sex-matched, and body surface area-matched control population, and athletes (defined as individuals who exercised for more than 7 hours per week). Patients with structural heart disease were excluded in the control and athlete groups. RESULTS: Twenty patients with ARVC/D, 11 athletes and 20 matched controls were included. There was no significant difference between ARVC/D patients and athletes with the exception of the parasternal long axis right ventricular outflow tract diameter. All parameters were significantly different between ARVC/D patients and the control group. Furthermore, when subjects were categorized into meeting 1 major revised TFC/abnormal ASE criteria or not, only ASE criteria were able to differentiate ARVC/D from control population. Both were unable to differentiate ARVC/D from athletes. CONCLUSIONS: Right ventricle quantitative echocardiographic criteria in the revised TFC are not specific for ARVC/D. Care should be taken in applying these criteria in athletes.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Atletas , Ecocardiografia/métodos , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Disfunção Ventricular Direita/fisiopatologia
7.
Expert Opin Biol Ther ; 19(4): 313-333, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30682895

RESUMO

INTRODUCTION: Inherited arrhythmias are an uncommon, but malignant family of cardiac diseases that result from genetic abnormalities in the ion channels and/or structural proteins within cardiomyocytes. Given the inherent differences between species and the limited reproducibility of in vitro heterologous cell models, progress in understanding the mechanisms underlying these malignant diseases has always languished far behind the clinical science and need. The ability to study human induced pluripotent stem cells (iPSCs) derived cardiomyocytes promises to change this paradigm as patient cells have the potential to become testing platforms for disease phenotyping or therapeutic discovery. AREAS COVERED: This review will outline methods developed to genetically reprogram adult cells into iPSCs, differentiate iPSCs into ex vivo models of adult cardiac tissue and iPSCs-based progress in exploring the mechanisms underlying pro-arrhythmic disease phenotypes. EXPERT OPINION: Despite being discovered less than 15 years ago, several studies have successfully leveraged iPSCs-derived cardiomyocytes to study malignant arrhythmogenic diseases. These models promise to increase our understanding of the pathophysiology underlying these complex diseases and may identify personalized approaches to treatment.


Assuntos
Arritmias Cardíacas/terapia , Células-Tronco Pluripotentes Induzidas/transplante , Arritmias Cardíacas/patologia , Síndrome de Brugada/terapia , Diferenciação Celular , Reprogramação Celular , Estimulação Elétrica , Vetores Genéticos/metabolismo , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Síndrome do QT Longo/terapia , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo