1.
J Vasc Access ; 17(1): 13-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26391583

RESUMO

PURPOSE: The usefulness of access blood flow (QA) measurement is an ongoing controversy. Although all vascular access (VA) clinical guidelines recommend monitoring and surveillance protocols to prevent VA thrombosis, randomized clinical trials (RCTs) have failed to consistently show the benefits of QA-based surveillance protocols. We present a 3-year follow-up multicenter, prospective, open-label, controlled RCT, to evaluate the usefulness of QA measurement using Doppler ultrasound (DU) and ultrasound dilution method (UDM), in a prevalent hemodialysis population with native arteriovenous fistula (AVF). METHODS: Classical monitoring and surveillance methods are applied in all patients, the control group (n = 98) and the QA group (n = 98). Besides this, DU and UDM are performed in the QA group every three months. When QA is under 500 ml/min or there is a >25% decrease in QA the patient goes for fistulography, surgery or close clinical/surveillance observation. Thrombosis rate, assisted primary patency rate, primary patency rate and secondary patency rate are measured. RESULTS: After one-year follow-up we found a significant reduction in thrombosis rate (0.022 thrombosis/patient/year at risk in the QA group compared to 0.099 thrombosis/patient/year at risk in the control group [p = 0.030]). Assisted primary patency rate was significantly higher in the QA group than in control AVF (hazard ratio [HR] 0.23, 95% confidence interval [CI] 0.05-0.99; p = 0.030). In the QA group, the numbers unddergoing angioplasty and surgery were higher but with no significant difference in non-assisted primary patency rate (HR 1.41, 95% CI 0.72-2.84; p = 0.293). There was a non-significant improvement in secondary patency rate in the QA group (HR 0.510, 95% CI 0.17-1.50; p = 0.207). CONCLUSIONS: The measurement of QA combining DU and UDM shows a reduction in thrombosis rate and an increased assisted primary patency rate in AVF after one-year follow-up. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02111655.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/prevenção & controle , Diálise Renal , Trombose/prevenção & controle , Ultrassonografia Doppler , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Fatores de Risco , Espanha , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA