1.
PLoS Comput Biol ; 17(10): e1009460, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34710086

RESUMO

Fifth generation networks (5G) will be associated with a partial shift to higher carrier frequencies, including wavelengths comparable in size to insects. This may lead to higher absorption of radio frequency (RF) electromagnetic fields (EMF) by insects and could cause dielectric heating. The yellow fever mosquito (Aedes aegypti), a vector for diseases such as yellow and dengue fever, favors warm climates. Being exposed to higher frequency RF EMFs causing possible dielectric heating, could have an influence on behavior, physiology and morphology, and could be a possible factor for introduction of the species in regions where the yellow fever mosquito normally does not appear. In this study, the influence of far field RF exposure on A. aegypti was examined between 2 and 240 GHz. Using Finite Difference Time Domain (FDTD) simulations, the distribution of the electric field in and around the insect and the absorbed RF power were found for six different mosquito models (three male, three female). The 3D models were created from micro-CT scans of real mosquitoes. The dielectric properties used in the simulation were measured from a mixture of homogenized A. aegypti. For a given incident RF power, the absorption increases with increasing frequency between 2 and 90 GHz with a maximum between 90 and 240 GHz. The absorption was maximal in the region where the wavelength matches the size of the mosquito. For a same incident field strength, the power absorption by the mosquito is 16 times higher at 60 GHz than at 6 GHz. The higher absorption of RF power by future technologies can result in dielectric heating and potentially influence the biology of this mosquito.


Assuntos
Aedes , Mosquitos Vetores , Ondas de Rádio , Aedes/fisiologia , Aedes/efeitos da radiação , Animais , Feminino , Temperatura Alta , Masculino , Mosquitos Vetores/fisiologia , Mosquitos Vetores/efeitos da radiação , Febre Amarela/transmissão
2.
Environ Int ; 156: 106711, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34153890

RESUMO

BACKGROUND: Exposure to radiofrequency electromagnetic fields (RF-EMF) is often measured with personal exposimeters, but the accuracy of measurements can be hampered as carrying the devices on-body may result in body shielding. Further, the compact design may compromise the frequency selectivity of the sensor. The aim of this study was to compare measurements obtained using a multi-band body-worn distributed-exposimeter (BWDM) with two commercially available personal exposimeters (ExpoM-RF and EmeSpy 200) under real-life conditions. METHODS: The BWDM measured power density in 10 frequency bands (800, 900, 1800, 2100, 2600 MHz, DECT 1900 MHz, WiFi 2.4 GHz; with separate uplink/downlink bands for 900, 1800 and 2100 MHz); using 20 separate antennas integrated in a vest and placed on diametrically opposite locations on the body, to minimize body-shielding. RF-EMF exposure data were collected from several microenvironments (e.g. shopping areas, train stations, outdoor rural/ urban residential environments, etc.) by walking around pre-defined areas/routes in Belgium, Spain, France, the Netherlands and Switzerland. Measurements were taken every 1-4 s with the BWDM in parallel with an ExpoM-RF and an EmeSpy 200 exposimeter. We calculated medians and interquartile ranges (IQRs) and compared difference, ratios and correlations of geometric mean RF-EMF exposure levels per microenvironment as measured with the exposimeters and the BWDM. RESULTS: Across 267 microenvironments, medians and IQR of total BWDM measured RF-EMF exposure was 0.13 (0.05-0.33) mW/m2. Difference: IQR of exposimeters minus BWDM exposure levels was -0.011 (-0.049 to 0.0095) mW/m2 for the ExpoM-RF and -0.056 (-0.14 to -0.017) for the EmeSpy 200; ratios (exposimeter/BWDM) of total exposure had an IQR of 0.79 (0.55-1.1) for the ExpoM-RF and 0.29 (0.22-0.38) for the EmeSpy 200. Spearman correlations were 0.93 for the ExpoM-RF vs the BWDM and 0.96 for the EmeSpy 200 vs the BWDM. DISCUSSION AND CONCLUSIONS: Results indicate that exposimeters worn on-body provide somewhat lower total RF-EMF exposure as compared to measurements conducted with the BWDM, in line with effects from body shielding. Ranking of exposure levels of microenvironments showed high correspondence between the different device types. Our results are informative for the interpretation of existing epidemiological research results.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Campos Eletromagnéticos/efeitos adversos , Exposição Ambiental , Ondas de Rádio/efeitos adversos , Espanha , Suíça
3.
IEEE Trans Biomed Circuits Syst ; 14(6): 1218-1229, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33170783

RESUMO

This paper presents a millimeter-scale crystal-less wireless transceiver for volume-constrained insertable pills. Operating in the 402-405 MHz medical implant communication service (MICS) band, the phase-tracking receiver-based over-the-air carrier recovery has a ±160 ppm coverage. A fully integrated adaptive antenna impedance matching solution is proposed to calibrate the antenna impedance variation inside the body. A tunable matching network (TMN) with single inductor performs impedance matching for both transmitter (TX) and receiver (RX) and TX/RX mode switching. To dynamically calibrate the antenna impedance variation over different locations and diet conditions, a loop-back power detector using self-mixing is adopted, which expands the power contour up to 4.8 VSWR. The transceiver is implemented in a 40-nm CMOS technology, occupying 2 mm2 die area. The transceiver chip and a miniature antenna are integrated in a 3.5 × 15 mm2 area prototype wireless module. It has a receiver sensitivity of -90 dBm at 200 kbps data rate and delivers up to - 25 dBm EIRP in the wireless measurement with a liquid phantom.


Assuntos
Eletrônica Médica/instrumentação , Gastroscopia/instrumentação , Tecnologia sem Fio/instrumentação , Desenho de Equipamento , Humanos , Modelos Biológicos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador/instrumentação , Estômago/diagnóstico por imagem
4.
Environ Res ; 175: 1-10, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31096087

RESUMO

When making phone calls, cellphone and smartphone users are exposed to radio-frequency (RF) electromagnetic fields (EMFs) and sound pressure simultaneously. Speech intelligibility during mobile phone calls is related to the sound pressure level of speech relative to potential background sounds and also to the RF-EMF exposure, since the signal quality is correlated with the RF-EMF strength. Additionally, speech intelligibility, sound pressure level, and exposure to RF-EMFs are dependent on how the call is made (on speaker, held at the ear, or with headsets). The relationship between speech intelligibility, sound exposure, and exposure to RF-EMFs is determined in this study. To this aim, the transmitted RF-EMF power was recorded during phone calls made by 53 subjects in three different, controlled exposure scenarios: calling with the phone at the ear, calling in speaker-mode, and calling with a headset. This emitted power is directly proportional to the exposure to RF EMFs and is translated into specific absorption rate using numerical simulations. Simultaneously, sound pressure levels have been recorded and speech intelligibility has been assessed during each phone call. The results show that exposure to RF-EMFs, quantified as the specific absorption in the head, will be reduced when speaker-mode or a headset is used, in comparison to calling next to the ear. Additionally, personal exposure to sound pressure is also found to be highest in the condition where the phone is held next to the ear. On the other hand, speech perception is found to be the best when calling with a phone next to the ear in comparison to the other studied conditions, when background noise is present.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Ondas de Rádio , Inteligibilidade da Fala , Telefone Celular/instrumentação , Telefone Celular/normas , Humanos , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle
5.
Sensors (Basel) ; 18(1)2018 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-29346280

RESUMO

A multi-band Body-Worn Distributed exposure Meter (BWDM) calibrated for simultaneous measurement of the incident power density in 11 telecommunication frequency bands, is proposed. The BDWM consists of 22 textile antennas integrated in a garment and is calibrated on six human subjects in an anechoic chamber to assess its measurement uncertainty in terms of 68% confidence interval of the on-body antenna aperture. It is shown that by using multiple antennas in each frequency band, the uncertainty of the BWDM is 22 dB improved with respect to single nodes on the front and back of the torso and variations are decreased to maximum 8.8 dB. Moreover, deploying single antennas for different body morphologies results in a variation up to 9.3 dB, which is reduced to 3.6 dB using multiple antennas for six subjects with various body mass index values. The designed BWDM, has an improved uncertainty of up to 9.6 dB in comparison to commercially available personal exposure meters calibrated on body. As an application, an average incident power density in the range of 26.7-90.8 µW·m - 2 is measured in Ghent, Belgium. The measurements show that commercial personal exposure meters underestimate the actual exposure by a factor of up to 20.6.


Assuntos
Ondas de Rádio , Bélgica , Calibragem , Campos Eletromagnéticos , Humanos , Monitoramento de Radiação , Incerteza
6.
Radiat Prot Dosimetry ; 176(3): 316-321, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28338842

RESUMO

For the first time, a personal exposimeter (PEX) for 60 GHz radiation measurements is presented. The PEX is designed based on numerical simulations and both on-body and on-phantom calibration measurements to determine the antenna aperture and measurement uncertainty of the PEX. The measurement uncertainty of the PEX is quantified in terms of 50 and 95% prediction intervals of its response. A PEX consisting of three nodes (antennas) with VHH (vertical-horizontal-horizontal) polarization results in a 95% prediction interval of 6.6 dB. A 50% prediction interval of 1.3 dB (factor of 1.3) is obtained for measured power densities which is 3.1 dB lower than a single antenna experiment. The uncertainty is 19.7 dB smaller than that of existing commercial exposimeters at lower frequencies (≤6GHz).


Assuntos
Exposição Ambiental/análise , Ondas de Rádio , Radiometria/instrumentação , Calibragem , Desenho de Equipamento , Humanos , Tecnologia sem Fio
7.
J Environ Health Sci Eng ; 12(1): 1, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24393372

RESUMO

The degradation of methyl tert-butyl ether (MTBE) was investigated in the aqueous solution of coated ZnO onto magnetite nanoparticale based on an advanced photocatalytic oxidation process. The photocatalysts were synthesized by coating of ZnO onto magnetite using precipitation method. The sample was characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and vibration sample magnetometer (VSM). Besides, specific surface area was also determined by BET method. The four effective factors including pH of the reaction mixture, Fe3O4/ZnO magnetic nanoparticles concentration, initial MTBE concentration and molar ratio of [H2O2]/ [MTBE] were optimized using response surface modeling (RSM). Using the four-factor-three-level Box-Behnken design, 29 runs were designed considering the effective ranges of the influential factors. The optimized values for the operational parameters under the respective constraints were obtained at PH of 7.2, Fe3O4/ZnO concentration of 1.78 g/L, initial MTBE concentration of 89.14 mg/L and [H2O2]/ [MTBE] molar ratio of 2.33. Moreover, kinetics of MTBE degradation was determined under optimum condition. The study about core/shell magnetic nanoparticles (MNPs) recycling were also carried out and after about four times, the percentage of the photocatalytic degradation was about 70%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA