RESUMO
Single cell halo assay (HaloChip) is used to quantify DNA repair ability and predict the efficacy of anticancer drugs. After exposure to drugs, cells are patterned onto a substrate to form an ordered single cell array, then embedded inside an agarose gel, and fluorescently stained to generate a characteristic halo surrounding each cell. The extent of DNA repair is quantified by using a relative nuclear diffusion factor (rNDF) derived from the surface areas of nuclei and halos. Several repair-competent and repair-deficient cell lines have been used to validate this method. Drug-inhibitor combinations are also tested in the context of synthetic lethality of chemotherapy, where the use of a repair inhibitor potentiates the effects of DNA damaging agents. This paper highlights the important role of HaloChip in quantifying DNA repair ability, which provides the diagnostic utility to enhance the efficacies of anticancer drugs.
Assuntos
Antineoplásicos/farmacologia , Procedimentos Analíticos em Microchip/métodos , Análise de Célula Única/métodos , Hipóxia Celular , Dano ao DNA , Reparo do DNA/efeitos dos fármacos , Células HCT116 , Humanos , Análise de Célula Única/instrumentaçãoRESUMO
This paper describes a nanoparticle enhanced X-ray irradiation based strategy that can be used to kill multidrug resistant (MDR) bacteria. In the proof-of-concept experiment using MDR Pseudomonas aeruginosa (P. aeruginosa) as an example, polyclonal antibody modified bismuth nanoparticles are introduced into bacterial culture to specifically target P. aeruginosa. After washing off uncombined bismuth nanoparticles, the bacteria are irradiated with X-rays, using a setup that mimics a deeply buried wound in humans. Results show that up to 90% of MDR P. aeruginosa are killed in the presence of 200 µg ml(-1) bismuth nanoparticles, whereas only â¼6% are killed in the absence of bismuth nanoparticles when exposed to 40 kVp X-rays for 10 min. The 200 µg ml(-1) bismuth nanoparticles enhance localized X-ray dose by 35 times higher than the control with no nanoparticles. In addition, no significant harmful effects on human cells (HeLa and MG-63 cells) have been observed with 200 µg ml(-1) bismuth nanoparticles and 10 min 40 kVp X-ray irradiation exposures, rendering the potential for future clinical use. Since X-rays can easily penetrate human tissues, this bactericidal strategy has the potential to be used in effectively killing deeply buried MDR bacteria in vivo.
Assuntos
Antibacterianos/farmacologia , Resistência Microbiana a Medicamentos , Nanopartículas/química , Nanotecnologia/métodos , Pseudomonas aeruginosa/efeitos dos fármacos , Bactérias/efeitos dos fármacos , Bismuto/química , Linhagem Celular Tumoral , Relação Dose-Resposta a Droga , Sistemas de Liberação de Medicamentos , Células HeLa , Humanos , Método de Monte Carlo , Polietilenoglicóis/química , Propriedades de Superfície , Raios XRESUMO
Traditional in vitro nanotoxicity researches are conducted on cultured two-dimensional (2D) monolayer cells and thereby cannot reflect organism response to nanoparticle toxicities at tissue levels. This paper describes a new, high-throughput approach to test in vitro nanotoxicity in three-dimensional (3D) microtissue array, where microtissues are formed by seeding cells in nonsticky microwells, and cells are allowed to aggregate and grow into microtissues with defined size and shape. Nanoparticles attach and diffuse into microtissues gradually, causing radial cytotoxicity among cells, with more cells being killed on the outer layers of the microtissue than inside. Three classical toxicity assays [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] (MTT), glucose-6-phosphate dehydrogenase (G6DP), and calcein AM and ethidium homodimer (calcein AM/EthD-1)] have been adopted to verify the feasibility of the proposed approach. Results show that the nanotoxicities derived from this method are significantly lower than that from traditional 2D cultured monolayer cells (p < 0.05). Equipped with a microplate reader or a microscope, the nanotoxicity assay could be completed automatically without transferring the microtissue, ensuring the reliability of toxicity assay. The proposed approach provides a new strategy for high-throughput, simple, and accurate evaluation of nanoparticle toxicities by combining 3D microtissue array with a panel of classical toxicity assays.