Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Glaucoma ; 3(2): 139-144, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32672597

RESUMO

PURPOSE: Tube perforations are a common method of achieving early intraocular pressure control with ligated glaucoma drainage devices (GDDs). Our purpose was to investigate how bending GDD tubes affects the performance of needle perforations. DESIGN: Experimental report. PARTICIPANTS: Twenty silicone GDD tubes attached to 27 G Rycroft cannulae tied with 7-0 Vicryl 10 mm from the cannulae tips. METHODS: Silicone GDD tubing was fitted over a 27 G Rycroft cannula and tied with a 7-0 suture 10 mm from the cannula tip. The tube was perforated 4 mm from the cannula tip with a 25 G needle (tube was kept straight). The tube was secured in a 50-mm water bath. Aqueous food dye was infused through the cannula from an adjustable height. The tube was observed under magnification while the height of the fluid column was adjusted to establish the pressure gradient at which the tube leaked dye (opening pressure) and ceased to leak (closing pressure), while the tube was held straight and bent 90 degrees. Measurements were repeated after a second perforation and a third perforation. Ten tubes were tested this way with 3 sequential slits. The entire experiment was repeated with another 10 tubes, but this time the tube was allowed to bend within the 3.5-mm open prongs of a needle holder during needle perforation. MAIN OUTCOME MEASURES: Opening and closing pressures. RESULTS: For each tube, the opening and closing pressures were similar and highly reproducible, but there was wide variation between tubes. In the tubes kept straight when perforated, the opening/closing pressure ranged from 5 to 25 cmH2O. The opening and closing pressures of slits made in the bent tube were significantly lower, frequently leaking at <1 cmH2O. Bending the tube after perforation could close a slit and prevent leakage at high perfusion pressure. The second and third successive perforations caused lower opening and closing pressures. CONCLUSIONS: Tube perforations behave like pressure-sensitive valves, opening whenever intraluminal pressure increases above a specific value. However, we found a large variation in the performance of fenestrations made with a 25-G hypodermic needle. Allowing the GDD tube to bend during needle perforation increases the risk of very low opening and closing pressures.


Assuntos
Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Glaucoma/fisiopatologia , Humanos , Complicações Intraoperatórias , Ligadura , Hipotensão Ocular/diagnóstico , Hipotensão Ocular/fisiopatologia , Reoperação , Suturas
2.
BMJ Case Rep ; 2016: 10.1136/bcr-2015-212733, 2016 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-27095804

RESUMO

Taxanes are a class of microtubule stabilising agents used to treat a wide range of malignancies. Taxane drug-induced cystoid macula oedema (TDICMO) is a known but rare complication of therapy. First reported with Docetaxel in 2003 and Paclitaxel in 2007, there are currently less than 20 cases of TDICMO in the literature. Although most cases resolve following taxane cessation, several authors have tried using carbonic anhydrase inhibitors or intravitreal bevacizumab to accelerate resolution or when taxane therapy cannot be discontinued. We report the first published case of TDICMO treated with a single-eye trial of topical dorzolamide versus intravitreal bevacizumab.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Bevacizumab/administração & dosagem , Hidrocarbonetos Aromáticos com Pontes/efeitos adversos , Inibidores da Anidrase Carbônica/administração & dosagem , Edema Macular/tratamento farmacológico , Sulfonamidas/administração & dosagem , Taxoides/efeitos adversos , Tiofenos/administração & dosagem , Administração Tópica , Idoso , Humanos , Injeções Intravítreas , Edema Macular/induzido quimicamente , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA