Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cell Transplant ; 28(7): 856-863, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31046425

RESUMO

Ventricular arrhythmias (VA) are of major concern in the field of cell therapy, potentially limiting its safety and efficacy. We sought to investigate the effects of CD34+ cell therapy on VA burden in patients with chronic heart failure (CHF). We performed registry data analysis of patients with CHF and implanted ICD/CRT devices treated with transendocardial CD 34+ cell therapy. Demographic, echocardiographic, and biochemical parameters were analyzed. Device records were reviewed and the number and type of VA 1 year prior to and 1 year after cell therapy were analyzed. All patients underwent electroanatomical mapping, and myocardial scar was defined as unipolar voltage (UV) <8.3 mV and linear local shortening (LLS) <6%. Of 209 patients screened, 48 met inclusion criteria. The mean age of the patients was 52 years and 88% were male. Nonischemic and ischemic cardiomyopathy were present in 55% and 45% of patients. The average serum creatinine was 91±26 µmol/L, serum bilirubin 18±9 µmol/L, NT-proBNP 1767 (468, 2446) pg/mL, LVEF 27±9% and 6' walk test 442±123 m. The average scar burden in patients with nonischemic and ischemic DCM was 58±15% and 51±25% (P=0.48). No significant difference in VA burden was observed before and after cell therapy (48% vs. 44%; P=0.68). ICD activation occurred in 19% and 27% of patients before and after cell therapy (P=0.33). According to our results, transendocardial CD34+ cell therapy does not appear to increase the risk of VA in chronic heart failure patients.


Assuntos
Antígenos CD34/metabolismo , Arritmias Cardíacas/etiologia , Terapia Baseada em Transplante de Células e Tecidos/métodos , Insuficiência Cardíaca/fisiopatologia , Adulto , Arritmias Cardíacas/fisiopatologia , Doença Crônica , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
Heart Surg Forum ; 16(3): E155-7, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23803241

RESUMO

The incidence of cardiac rupture complicating myocardial infarction has declined since the introduction of thrombolytic therapy. Despite the advances in the management of myocardial infarction, cardiac rupture remains an important cause of death among infarction-related fatalities. We discuss a patient who presented to our hospital with myocardial infarction and who subsequently developed a complex ventricular septal rupture, for which surgical repair was not feasible. Implantation of a CardioWest Total Artificial Heart (SynCardia Systems) allowed for immediate hemodynamic stabilization and served as a bridge to transplantation.


Assuntos
Comunicação Interventricular/etiologia , Comunicação Interventricular/cirurgia , Transplante de Coração , Coração Artificial , Infarto do Miocárdio/complicações , Ruptura do Septo Ventricular/etiologia , Ruptura do Septo Ventricular/cirurgia , Terapia Combinada , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA