Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Drug Test Anal ; 13(11-12): 1822-1834, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33942526

RESUMO

Intact phase II steroid metabolites have poor product ion mass spectra under collision-induced dissociation (CID) conditions. Therefore, we present herein the liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/(MS)) behavior of intact phase II metabolites of oxosteroids after derivatization. Based on the fact that Girard's reagent T (GRT), as derivatization reagent, was both convenient and efficient in terms of the enhancement in the ionization efficiency and the production of diagnostic product ions related to the steroid moiety, the latter was preferably selected between methoxamine and hydroxylamine upon the model compounds of androsterone glucuronide and androsterone sulfate. Sixteen different glucuronides and 29 sulfate conjugated metabolites of anabolic androgenic steroids (AASs), available either as pure reference materials or synthesized/extracted from administration studies, were derivatized with GRT, and their product ion spectra are presented. Product ion spectra include in all cases high number of product ions that in some cases are characteristic for certain structures of the steroid backbone. More specifically, preliminary results have shown major differences in fragmentation pattern for 17α/17ß-isomers of the sulfate conjugates, but limited differentiation for 17α/17ß-isomers of glucuronide conjugates and for 3α/3ß- and 5α/5ß-stereoisomers of both sulfate and glucuronide conjugates. Further to the suggestion of the current work, application on mesterolone administration studies confirmed-according to the World Anti-Doping Agency (WADA) TD2015IDCR-the presence of seven intact phase II metabolites, one glucuronide and six sulfates with use of LC-ESI-MS/(MS).


Assuntos
Anabolizantes/análise , Androsterona/análogos & derivados , Dopagem Esportivo/prevenção & controle , Mesterolona/análise , Anabolizantes/química , Androsterona/análise , Androsterona/química , Betaína/análogos & derivados , Betaína/química , Cromatografia Líquida/métodos , Humanos , Mesterolona/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
2.
Drug Test Anal ; 10(11-12): 1635-1645, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30255601

RESUMO

Selective androgen receptor modulators (SARMs) are an emerging class of therapeutics targeted to cachexia, sarcopenia, and hypogonadism treatment. LGD-4033 is a SARM which has been included on the Prohibited List annually released by the World Anti-Doping Agency (WADA). The aim of the present work was the investigation of the metabolism of LGD-4033 in a human excretion study after administration of an LGD-4033 supplement, the determination of the metabolites' excretion profiles with special interest in the determination of its long-term metabolites, and the comparison of the excretion time of the phase I and phase II metabolites. The results were also compared to those derived from previous LGD-4033 studies concerning both in vitro and in vivo experiments. Supplement containing LGD-4033 was administered to one human male volunteer and urine samples were collected up to almost 21 days. Analysis of the hydrolyzed (with ß-glucuronidase) as well as of the non-hydrolyzed samples was performed using liquid chromatography-high resolution mass spectrometry (LC-HRMS) in negative ionization mode and revealed that, in both cases, the two isomers of the dihydroxylated metabolite (M5) were preferred target metabolites. The gluco-conjugated parent LGD-4033 and its gluco-conjugated metabolites M1 and M2 can be also considered as useful target analytes in non-hydrolyzed samples. The study also presents two trihydroxylated metabolites (M6) identified for the first time in human urine; one of them was recently reported in an LGD-4033 metabolism study in horse urine and plasma.


Assuntos
Androgênios/metabolismo , Androgênios/urina , Nitrilas/metabolismo , Nitrilas/urina , Pirrolidinas/metabolismo , Pirrolidinas/urina , Androgênios/administração & dosagem , Androgênios/análise , Cromatografia Líquida/métodos , Suplementos Nutricionais/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Hidrólise , Masculino , Espectrometria de Massas/métodos , Nitrilas/administração & dosagem , Nitrilas/análise , Pirrolidinas/administração & dosagem , Pirrolidinas/análise , Detecção do Abuso de Substâncias/métodos
3.
J Pharm Biomed Anal ; 90: 207-14, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24389463

RESUMO

A simplified gas chromatographic-mass spectrometric (GC-MS) analytical method, involving a novel derivatization procedure was developed for monitoring busulfan (Bu) plasma concentrations in populations undergoing bone marrow transplantation. Plasma samples (500 µL) containing Bu-d8 as internal standard were extracted with ethyl acetate (2 mL) followed by centrifugation (1800 rpm, 5 min) and evaporation of the organic layer under nitrogen flow (50 °C). The dry residue was reconstituted with 100 µL iodine solution in acetonitrile (0.25%, w/v) and 3 µL were injected into the GC-MS system at 250 °C. Conversion of Bu to 1,4-diiodobutane was accomplished on-line without the need of an extra derivatization step. MS was operated at selected ion monitoring mode at m/z 183 and 191 corresponding to Bu and Bu-d8 derivatives. Total analysis time was 11.5 min. Calibration curves were linear (mean r=0.9996) over a concentration range of 25-3651 ng/mL using a (1/x)-weighted scheme. Limit of detection and lower limit of quantitation were 10.6 and 25 ng/mL, respectively. Overall accuracy Er (%) was ranging from -5.10% to 10.5%. Within- and between-run RSD (%) were lower 4.51% and 2.15%, respectively. Overall recovery of Bu was equal to 69.3±4.56% (RSD (%)). The present method is sensitive and specific, requiring a simple sample preparation procedure and short analysis time, advantages crucial for therapeutic drug monitoring of Bu in clinical practice and application in pharmacokinetic studies.


Assuntos
Antineoplásicos Alquilantes/farmacocinética , Bussulfano/farmacocinética , Monitoramento de Medicamentos/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Calibragem , Humanos , Hidrocarbonetos Iodados/análise , Limite de Detecção , Espectrometria de Massas , Reprodutibilidade dos Testes , Fatores de Tempo
4.
Drug Test Anal ; 4(12): 923-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22374794

RESUMO

In gas chromatographic-combustion-isotope ratio mass spectrometry (GC-C-IRMS) doping control analysis, endogenous androgenic anabolic steroids and their metabolites are commonly acetylated using acetic anhydride reagent, thus incorporating exogenous carbon that contributes to the measured isotope ratio. Comparison of the endogenous δ(13)C of free, mono-, and di-acetylated steroids requires application of corrections, typically through straightforward use of the mass balance equation. Variability in kinetic isotope effects (KIE) due to steroid structures could cause fractionation of endogenous steroid carbon, resulting in inaccurate results. To test for possible KIE influence on δ(13)C, acetic anhydride of graded isotope ratio within the natural abundance range was used under normal derivatization conditions to test for linearity. In all cases, plots of measured steroid acetate δ(13)C versus acetic anhydride δ(13)C were linear and slopes were not significantly different. Regression analysis of the Δδ(13)C of enriched acetic anhydrides versus Δδ(13)C of derivatized steroids shows that KIE are similar in all cases. We conclude that δ(13)C calculated from the mass balance equation is independent of the δ(13)C of the acetic anhydride reagent, and that net KIE under normal derivatization conditions do not bias the final reported steroid δ(13)C.


Assuntos
Anabolizantes/urina , Isótopos de Carbono/urina , Dopagem Esportivo , Cromatografia Gasosa-Espectrometria de Massas , Substâncias para Melhoria do Desempenho/urina , Esteroides/urina , Detecção do Abuso de Substâncias/métodos , Anidridos Acéticos/química , Acetilação , Biomarcadores/urina , Calibragem , Humanos , Cinética , Modelos Lineares , Valor Preditivo dos Testes , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes
5.
J Chromatogr A ; 1218(33): 5675-82, 2011 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-21752385

RESUMO

An alternative calibration procedure for the gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) measurements of the World Antidoping Agency (WADA) Accredited Laboratories is presented. To alleviate the need for externally calibrated CO2 gas for GC-C-IRMS analysis of urinary steroid metabolites, calibration using an external standard mixture solution of steroids with certified isotopic composition was investigated. The reference steroids of the calibration mixture and routine samples underwent identical instrumental processes. The calibration standards bracketed the entire range of the relevant δ¹³C values for the endogenous and exogenous steroids as well as their chromatographic retention times. The certified δ¹³C values of the reference calibrators were plotted in relation to measured m/z ¹³CO2/¹²CO2 (i.e. R(45/44)) mass spectrometric signals of each calibrator. δ¹³C values of the sample steroids were calculated from the least squares fit through the calibration curve. The effect of the external calibration on δ¹³C values, using the same calibration standards and set of urine samples but different brands of GC-C-IRMS instruments, was assessed by an interlaboratory study in the WADA Accredited Laboratories of Sydney, Australia and Athens, Greece. Relative correspondence between the laboratories for determination of androsterone, etiocholanolone, 5ß-androstane-3α,17ß-diacetate, and pregnanediacetate means were SD(δ¹³C)=0.12‰, 0.58‰, -0.34‰, and -0.40‰, respectively. These data demonstrate that accurate intralaboratory external calibration with certified steroids provided by United States Antidoping Agency (USADA) and without external CO2 calibration is feasible and directly applicable to the WADA Accredited Laboratories for the harmonization of the GC-C-IRMS measurements.


Assuntos
Anabolizantes/urina , Dopagem Esportivo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Esteroides/urina , Detecção do Abuso de Substâncias/métodos , Calibragem , Isótopos de Carbono/análise , Cromatografia Gasosa-Espectrometria de Massas/normas , Humanos , Masculino , Detecção do Abuso de Substâncias/normas
6.
Rapid Commun Mass Spectrom ; 21(15): 2439-46, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17610244

RESUMO

A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration time-of-flight mass spectrometry (GCoaTOFMS) has been developed in order to acquire accurate full scan MS data to be used to detect designer steroids. The developed method allowed the detection of representative prohibited substances, in addition to steroids, at concentrations of 10 ng/mL for anabolic agents and metabolites, 30 ng/mL for corticosteroids, 500 ng/mL for stimulants and beta-blockers, 250 ng/mL for diuretics, and 200 ng/mL for narcotics. Sample preparation was based on liquid-liquid extraction of hydrolyzed human urine, and the final extract was analyzed as trimethylsilylated derivatives in GCoaTOFMS and underivatized in LCoaTOFMS in positive ion mode. The sensitivity, mass accuracy, advantages and limitations of the developed method are presented.


Assuntos
Anabolizantes/urina , Cromatografia Líquida de Alta Pressão/métodos , Drogas Desenhadas/análise , Dopagem Esportivo/prevenção & controle , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Esteroides/urina , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 827(2): 199-204, 2005 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-16242387

RESUMO

A study of the metabolism of isometheptene, an antispasmodic drug, in man and comparison with heptaminol metabolism, is presented in this paper. Isometheptene and two metabolites were detected in human urine after oral administration of a tablet containing isometheptene mucate. The urine level of the parent drug, which is excreted during the first 24 h, was determined using gas chromatography-mass spectrometry, after alkaline extraction with organic solvent. A minor metabolite of isometheptene was converted to heptaminol in vitro under the acidic hydrolysis conditions used for the screening procedure of stimulants and narcotics in doping control analysis.


Assuntos
Dopagem Esportivo/prevenção & controle , Cromatografia Gasosa-Espectrometria de Massas/métodos , Metilaminas/urina , Administração Oral , Heptaminol/metabolismo , Humanos , Metilaminas/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA