Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Gen Thorac Cardiovasc Surg ; 68(3): 295-297, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30560398

RESUMO

Left atrial appendage aneurysm (LAAA) is a rare congenital heart anomaly that frequently becomes apparent after middle age. We report a case of LAAA in a 63-year-old woman with stroke. After stabilization of ischemic cerebral stroke, the patient underwent left atrial appendectomy with full maze procedure and tricuspid annuloplasty under cardiac arrest with cardiopulmonary bypasss. She has been living a healthy life without anticoagulants postoperatively. Resection and the full-maze procedure is an efficacious and durable procedure for LAAA with chronic atrial fibrillation.


Assuntos
Apêndice Atrial/cirurgia , Aneurisma Cardíaco/complicações , Aneurisma Cardíaco/cirurgia , Procedimento do Labirinto , Acidente Vascular Cerebral/cirurgia , Animais , Anticoagulantes/uso terapêutico , Fibrilação Atrial/cirurgia , Isquemia Encefálica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Bovinos , Infarto Cerebral/cirurgia , Feminino , Átrios do Coração/cirurgia , Cardiopatias Congênitas/fisiopatologia , Humanos , Pessoa de Meia-Idade , Pericárdio/cirurgia , Recidiva
2.
Gen Thorac Cardiovasc Surg ; 68(5): 534-537, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-30875004

RESUMO

The patient was a 64-year-old man who had aortic regurgitation, ischemic heart disease, a transverse aortic aneurysm, and an abdominal-common iliac aneurysm. Concomitant operations including aortic valve replacement, coronary artery bypass grafting, and total aortic arch replacement with elephant trunk technique were performed successfully. The patient developed postoperative cardiac tamponade on the 5th postoperative day, resulting in bulbar palsy due to occlusion of the dominant left vertebral artery. Thrombectomy of the vertebral artery with reconstruction by a saphenous vein was performed. The patient's neurological symptoms improved after the operation. Revascularization of ischemic stroke may yield neurological improvement even in patients after cardiovascular surgery.


Assuntos
Isquemia Encefálica/cirurgia , Acidente Vascular Cerebral/cirurgia , Trombectomia , Trombose/cirurgia , Artéria Vertebral/cirurgia , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Isquemia Encefálica/etiologia , Paralisia Bulbar Progressiva/etiologia , Tamponamento Cardíaco/etiologia , Ponte de Artéria Coronária , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Complicações Pós-Operatórias/etiologia , Procedimentos de Cirurgia Plástica , Acidente Vascular Cerebral/etiologia , Trombose/etiologia
3.
Kyobu Geka ; 72(5): 380-383, 2019 May.
Artigo em Japonês | MEDLINE | ID: mdl-31268037

RESUMO

The patient was a 73-year-old woman with ventricular septal rupture following acute myocardial infarction. Morphologically, it was associated with ventricular septal dissection and septal pseudoaneurysm formation. She underwent repair of the septal rupture 12 days after the onset of myocardial infarction. The rupture site was excluded with two large bovine pericardial patches after partial resection of the necrotic tissue of the septum. The patches were doubly fixed to the ventricular septum and the free wall with interrupted mattress sutures and with continuous sutures. There was no residual shunt after the operation.


Assuntos
Ruptura Cardíaca Pós-Infarto , Infarto do Miocárdio , Ruptura do Septo Ventricular , Septo Interventricular , Idoso , Animais , Bovinos , Feminino , Ruptura Cardíaca Pós-Infarto/cirurgia , Humanos , Ruptura do Septo Ventricular/cirurgia
4.
J Vasc Surg Cases Innov Tech ; 5(2): 78-81, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31193449

RESUMO

The development of a secondary aortoenteric fistula is a well-described complication after open or endovascular repair of an abdominal aortic aneurysm. However, evidence regarding aortocolonic fistulas (ACFs) and their pathogenesis is currently limited. We present a case of ACF that developed 18 years after open repair of an abdominal aortic aneurysm with atypical symptoms. The patient was successfully treated with total resection of the involved aorta, prosthetic graft, and sigmoid colon, with extra-anatomic bypass and primary anastomosis of the residual colon. Pathologic examination revealed that the pathogenesis of ACF was attributed to sigmoid diverticulitis. This case report highlights the uncommon pathogenesis of ACF and the importance of considering revascularization and intestinal reconstruction in the surgical strategy for each individual case.

5.
Kyobu Geka ; 70(12): 1000-1004, 2017 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-29104199

RESUMO

A 73-year-old man was admitted for cardiac tamponade by oozing type left ventricular free wall rupture associated with acute myocardial infarction. Transthoracic echocardiography demonstrated moderate pericardial effusion and the presence of pseudoaneurysm within posterior wall. He went into shock with a systolic blood pressure of 60 mmHg. After introducing percutaneous cardiopulmonary support and intraaortic balloon pump, the sutureless repair was performed immediately. After having rehabilitation for right-sided hemiparesis, an elective pseudoaneurysm repair was planned. While a waiting an operation, 7 weeks later, he went into shock again with chest pain. Echocardiography and computed tomography demonstrated much amount of pericardial bloody effusion on the posterior aspect and 1.5 cm defect on the pseudoaneurysm wall. Emergently a patch closure with a bovine pericardium was performed using cardiopulmonary bypass under ventricular fibrillation through a left thoracotomy. Postoperative course was uneventful.


Assuntos
Ruptura Cardíaca Pós-Infarto/cirurgia , Ruptura Cardíaca/cirurgia , Infarto do Miocárdio/cirurgia , Idoso , Ruptura Cardíaca/diagnóstico por imagem , Ruptura Cardíaca/etiologia , Ruptura Cardíaca Pós-Infarto/diagnóstico por imagem , Ruptura Cardíaca Pós-Infarto/etiologia , Humanos , Masculino , Imagem Multimodal , Infarto do Miocárdio/complicações , Reoperação
6.
Ann Vasc Dis ; 10(1): 22-28, 2017 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-29034016

RESUMO

Objective: Endovascular repair has become the treatment of choice for ruptured abdominal aortic aneurysms (RAAAs). To improve surgical outcomes, preoperative management is important. In 2011, we introduced integrated management, which involves endovascular aneurysm repair, stabilization of hemodynamics by endovascular clamping, and open abdominal decompression to address abdominal compartment syndrome (ACS). Methods: To evaluate the efficacy of this management strategy, 62 patients who had undergone emergency surgery for an RAAA were analyzed retrospectively: group A (n=39), where an old strategy was used, and group B (n=23), where integrated management was introduced. Patient characteristics and 30-day mortality rates were compared between the two groups. Results: The average patient age was 67.7 years and 74.7 years for groups A and B, respectively (P=0.032). Group B patients required more frequent use of vasopressors (P=0.035). Other patient characteristics did not differ between the two groups. The duration of surgery was significantly shorter in group B than in group A (P=0.001). The total amount of transfused blood did not differ between the two groups. No patients showed symptoms of ACS. Early mortality rates were 12.8% and 8.7% in groups A and B, respectively. The number of wound infections was significantly fewer in group B than in group A. Conclusion: Although group B patients were significantly older and had a higher rate of vasopressor use, early mortality was improved in both groups. Morbidity was significantly better in group B with respect to the duration of surgery and number of wound infections than in group A.

7.
Ann Vasc Dis ; 10(1): 29-35, 2017 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-29034017

RESUMO

Purpose: A mycotic aneurysm is an uncommon disease associated with a high mortality rate when managed surgically. This study reviewed our experiences in the surgical management of mycotic aortic aneurysms. Methods: In total, 26 patients who underwent surgery for a mycotic aneurysm were retrospectively reviewed. The mycotic aneurysms involved the thoracic aorta in 9 patients, the thoracoabdominal aorta in 4 patients, and the abdominal aorta in 13 patients. An overt aortic rupture in the mediastinum or retroperitoneal space was detected in 4 patients. Patients were classified into one of two groups, febrile or afebrile, and background characteristics, surgical intervention, and early and late mortalities were all compared. Results: There were 19 patients who underwent open surgery, and 7 patients underwent endovascular repair. No significant differences in the clinical characteristics were found between the two groups; however, the incidence of postoperative complications was significantly higher in the febrile group than in the afebrile group (P=0.024). Overall mortality was 15.4% (4/26), and 30-day mortality was 7.7% (2/26). Conclusion: Although febrile patients had a higher incidence of postoperative complications, surgical mortality from a mycotic aneurysm was within an acceptable range. Each patient should be thoroughly evaluated and treated on a case-by-case basis, using conventional open repair, endovascular repair, or a combination of both approaches.

8.
Ann Thorac Surg ; 102(2): 518-26, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27133454

RESUMO

BACKGROUND: Annuloplasty ring dehiscence is a well described mode of mitral valve repair failure. Defining the mechanisms underlying dehiscence may facilitate its prevention. METHODS: Factors that govern suture dehiscence were examined with an ovine model. After undersized ring annuloplasty in live animals (n = 5), cyclic force (FC) that acts on sutures during cardiac contraction was measured with custom transducers. FC was measured at ten suture positions, throughout cardiac cycles with peak left ventricular pressure (LVPmax) of 100, 125, and 150 mm Hg. Suture pullout testing was conducted on explanted mitral annuli (n = 12) to determine suture holding strength at each position. Finally, relative collagen density differences at suture sites around the annulus were assessed by two-photon excitation fluoroscopy. RESULTS: Anterior FC exceeded posterior FC at each LVPmax (eg, 2.8 ± 1.3 N versus 1.8 ± 1.2 N at LVPmax = 125 mm Hg, p < 0.01). Anterior holding strength exceeded posterior holding strength (6.4 ± 3.6 N versus 3.9 ± 1.6 N, p < 0.0001). On the basis of FC at LVPmax of 150 mm Hg, margin of safety before suture pullout was vastly higher between the trigones (exclusive) versus elsewhere (4.8 ± 0.9 N versus 1.9 ± 0.5 N, p < 0.001). Margin of safety exhibited strong correlation to collagen density (R(2) = 0.947). CONCLUSIONS: Despite lower cyclic loading on posterior sutures, the weaker posterior mitral annular tissue creates higher risk of dehiscence, apparently because of reduced collagen content. Sutures placed atop the trigones are less secure than predicted, because of a combination of reduced collagen and higher overall rigidity in this region. These findings highlight the inter-trigonal tissue as the superior anchor and have implications on the design and implantation techniques for next-generation mitral prostheses.


Assuntos
Colágeno/metabolismo , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/métodos , Valva Mitral/cirurgia , Complicações Pós-Operatórias , Técnicas de Sutura/instrumentação , Suturas , Animais , Modelos Animais de Doenças , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Ovinos
9.
Ann Thorac Surg ; 100(4): 1360-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26184554

RESUMO

BACKGROUND: Current repair results for ischemic mitral regurgitation (IMR) with undersized annuloplasty rings are characterized by high IMR recurrence rates. Current annuloplasty rings treat annular dilatation, but they do little to improve (and may actually exacerbate) leaflet tethering. New saddle-shaped annuloplasty rings have been shown to maintain or restore a more physiologic annular and leaflet geometry and function. Using a porcine IMR model, we sought to demonstrate the influence of annuloplasty ring shape on leaflet coaptation. METHODS: Eight weeks after posterolateral infarct, eight pigs with grade 2+ or higher IMR were randomized to undergo either a 28-mm flat ring annuloplasty (n = 4) or a 28-mm saddle-shaped ring annuloplasty (n = 4). Real-time three-dimensional echocardiography and a customized image analysis protocol allowed three-dimensional assessment of leaflet coaptation before and after annuloplasty. RESULTS: Total leaflet coaptation area was significantly higher after saddle-shaped ring annuloplasty (109.6 ± 26.9 mm(2)) compared with flat ring annuloplasty (46.2 ± 7.7 mm(2), p <0.01). After annuloplasty, total coaptation area decreased by 87.5 mm(2) (or 65%) in the flat annuloplasty group (p = 0.01), whereas total coaptation area increased by 22.2 mm(2) (or 25%) in the saddle-shaped annuloplasty group (p = 0.28). CONCLUSIONS: This study shows that the use of undersized saddle-shaped annuloplasty rings in mitral valve repair for IMR improves leaflet coaptation, whereas the use of undersized flat annuloplasty rings worsens leaflet coaptation. Because one of Carpentier's fundamental principles of mitral valve repair (durability) is to create a large surface of coaptation, saddle-shaped annuloplasty may increase repair durability.


Assuntos
Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Animais , Próteses Valvulares Cardíacas , Masculino , Desenho de Prótese , Distribuição Aleatória , Suínos
10.
Ann Thorac Surg ; 100(1): 114-121, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25975941

RESUMO

BACKGROUND: Mitral valve (MV) repair using annuloplasty rings is the preferred method of treatment for MV regurgitation, but the impact of annuloplasty ring placement on left ventricular intraventricular flow has not been studied. METHODS: Annuloplasty rings of varying sizes were placed in 5 healthy sheep (intercommissural ring sizes were 24, 26, 28, 30, and 32 mm), and three-dimensional phase contrast magnetic resonance imaging (4D flow MRI) was performed before and 1 week after ring placement. RESULTS: Normal diastolic flow consisted of diastolic intraventricular vortices that naturally unwound during systole. Postsurgical intraventricular flow was highly disturbed in all sheep, and the disturbance was greatest for undersized rings. Ring size was highly correlated with the diastolic inflow angle (Pearson's r = -0.62, p < 0.1, 95% confidence interval: -0.92 to 0.14). There was a mean angle increase of mean diastolic inflow angle increase of 12.3 degrees (< 30 mm, p < 0.01, 95% confidence interval: 4.8 to 19.6) for rings less than 30 mm. There was an inverse relationship between peak velocity and annuloplasty ring area (Pearson's r = -0.80, p < 0.05, 95% confidence interval: -0.96 to -0.2). Transmitral pressure gradients increased significantly from baseline 0.73 ± 0.18 mm Hg to after annuloplasty 2.31 ± 1.04 mm Hg (p < 0.05). CONCLUSIONS: Mitral valve annuloplasty ring placement disturbs normal left ventricular intraventricular flow patterns, and the degree of disturbance is closely associated with annuloplasty ring size.


Assuntos
Hemodinâmica , Anuloplastia da Valva Mitral , Fluxo Sanguíneo Regional , Função Ventricular Esquerda , Animais , Ovinos
11.
Ann Thorac Surg ; 99(4): 1408-12, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25841820

RESUMO

PURPOSE: We describe our initial experience with on-bypass and off-bypass (off-pump) mitral valve replacement with the modified version of our novel catheter-based sutureless mitral valve (SMV) technology, which was developed to atraumatically anchor and seal in the mitral position. DESCRIPTION: The SMV is a self-expanding device consisting of a custom designed nitinol framework and a pericardial leaflet valve mechanism. For the current studies, our original device was modified (SMV2) to reduce the delivery profile and to allow for controlled deployment while still maintaining the key principles necessary for atraumatic anchoring and sealing in the mitral valve position. EVALUATION: Ten Yorkshire pigs underwent successful SMV2 device implantation through a left atriotomy (on-pump, n = 6; off-pump, n = 4). Echocardiography and angiography revealed excellent left ventricular systolic function, no significant perivalvular leak, no mitral valve stenosis, no left ventricular outflow tract obstruction, and no aortic valve insufficiency. Postmortem examination demonstrated that the SMV2 devices were anchored securely. CONCLUSIONS: This study demonstrates the feasibility and short-term success of off-pump mitral valve replacement using a novel, catheter-based device in a porcine model.


Assuntos
Cateterismo Cardíaco/métodos , Ponte Cardiopulmonar/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Animais , Modelos Animais de Doenças , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Desenho de Prótese , Sensibilidade e Especificidade , Técnicas de Sutura , Suínos
12.
Ann Thorac Surg ; 99(2): 597-603, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25524397

RESUMO

BACKGROUND: There is continued need for therapies which reverse or abate the remodeling process after myocardial infarction (MI). In this study, we evaluate the longitudinal effects of calcium hydroxyapatite microsphere gel on regional strain, global ventricular function, and mitral regurgitation (MR) in a porcine MI model. METHODS: Twenty-five Yorkshire swine were enrolled. Five were dedicated weight-matched controls. Twenty underwent posterolateral infarction by direct ligation of the circumflex artery and its branches. Infarcted animals were randomly divided into the following 4 groups: 1-week treatment; 1-week control; 4-week treatment; and 4-week control. After infarction, animals received either twenty 150 µL calcium hydroxyapatite gel or saline injections within the infarct. At their respective time points, echocardiograms, cardiac magnetic resonance imaging, and tissue were collected for evaluation of MR, regional and global left ventricular function, wall thickness, and collagen content. RESULTS: Global and regional left ventricular functions were depressed in all infarcted subjects at 1 week compared with healthy controls. By 4-weeks post-infarction, global function had significantly improved in the calcium hydroxyapatite group compared with infarcted controls (ejection fraction 0.485 ± 0.019 vs 0.38 ± 0.017, p < 0.01). Similarly, regional borderzone radial contractile strain (16.3% ± 1.5% vs 11.2% ± 1.5%, p = 0.04), MR grade (0.4 ± 0.2 vs 1.2 ± 0.2, p = 0.04), and infarct thickness (7.8 ± 0.5 mm vs 4.5 ± 0.2 mm, p < 0.01) were improved at this time point in the treatment group compared with infarct controls. CONCLUSIONS: Calcium hydroxyapatite injection after MI progressively improves global left ventricular function, borderzone function, and mitral regurgitation. Using novel biomaterials to augment infarct material properties is a viable alternative in the current management of heart failure.


Assuntos
Materiais Biocompatíveis/administração & dosagem , Durapatita/administração & dosagem , Géis/administração & dosagem , Microesferas , Insuficiência da Valva Mitral/terapia , Contração Miocárdica , Infarto do Miocárdio/terapia , Função Ventricular , Animais , Injeções Intralesionais , Masculino , Insuficiência da Valva Mitral/etiologia , Recuperação de Função Fisiológica , Suínos
13.
Ann Thorac Surg ; 98(1): 305-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24996707

RESUMO

PURPOSE: To demonstrate the first use of a novel technology for quantifying suture forces on annuloplasty rings to better understand the mechanisms of ring dehiscence. DESCRIPTION: Force transducers were developed, attached to a size 24 Physio ring, and implanted in the mitral annulus of an ovine animal. Ring suture forces were measured after implantation and for cardiac cycles reaching peak left ventricular pressures (LVP) of 100, 125, and 150 mm Hg. EVALUATION: After implantation of the undersized ring to the flaccid annulus, the mean suture force was 2.0±0.6 N. During cyclic contraction, the anterior ring suture forces were greater than the posterior ring suture forces at peak LVPs of 100 mm Hg (4.9±2.0 N vs 2.1±1.1 N), 125 mm Hg (5.4±2.3 N vs 2.3±1.2 N), and 150 mm Hg (5.7±2.4 N vs 2.4±1.1 N). The largest force was 7.4 N at 150 mm Hg. CONCLUSIONS: The preliminary results demonstrate trends in annuloplasty suture forces and their variation with location and LVP. Future studies will significantly contribute to clinical knowledge by elucidating the mechanisms of ring dehiscence while improving annuloplasty ring design and surgical repair techniques.


Assuntos
Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Técnicas de Sutura/instrumentação , Suturas , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Desenho de Prótese , Reprodutibilidade dos Testes , Ovinos , Transdutores
14.
Ann Thorac Surg ; 97(5): 1597-603, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24629301

RESUMO

BACKGROUND: Rapid determination of the left ventricular (LV) pressure-volume (PV) relationship as loading conditions are varied is the gold standard for assessment of LV function. Cine magnetic resonance imaging (MRI) does not have sufficient spatiotemporal resolution to assess beat-to-beat changes of the LV PV relationship required to measure the LV end-systolic elastance (EES) or preload-recruitable stroke work (PRSW). Our aim was to investigate real-time MRI and semiautomated LV measurement of LV volume to measure PV relations in large animals under normal and inotropically stressed physiologic conditions. METHODS: We determined that PV relationships could be accurately measured using an image exposure time Tex less than 100 ms and frame rate Tfr less than 50 ms at elevated heart rates (∼140 beats per minute) using a golden angle radial MRI k-space trajectory and active contour segmentation. RESULTS: With an optimized exposure time (Tex=95 ms and frame rate Tfr=2.8 ms), we found that there was no significant difference between cine and real-time MRI at rest in end-diastolic volume, end-systolic volume, ejection fraction, stroke volume, or cardiac output (n=5, p<0.05) at either normal or elevated heart rates. We found EES increased from 1.9±0.7 to 3.1±0.3 mm Hg/mL and PRSW increased from 6.2±1.2 to 9.1±0.9 mm Hg during continuous intravenous dobutamine infusion (n=5, p<0.05). CONCLUSIONS: Real-time MRI can assess LV volumes, EES, and PRSW at baseline and elevated inotropic states.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Animais , Débito Cardíaco/fisiologia , Modelos Animais de Doenças , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Masculino , Contração Miocárdica/fisiologia , Distribuição Aleatória , Sensibilidade e Especificidade , Suínos
15.
Innovations (Phila) ; 9(1): 16-21, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24562291

RESUMO

OBJECTIVE: Despite advances in design, modern ventricular assist device placement involves median sternotomy and cardiopulmonary bypass and is associated with infectious/embolic complications. In this study, we examine the feasibility and function of a novel minimally invasive, non-blood-contacting epicardial assist device in a porcine ischemic cardiomyopathy model. METHODS: Feasibility was first tested in an ex vivo thoracoscopic trainer box with slaughterhouse hearts. Five male Yorkshire swine underwent selective ligation of the circumflex artery to create a posterolateral infarct Twelve weeks after infarct, all animals underwent left minithoracotomy. A custom inflatable bladder was positioned over the epicardial surface of the infarct and firmly secured to the surrounding border zone myocardium with polypropylene mesh and minimally invasive mesh tacks. An external gas pulsation system actively inflated and deflated the bladder in synchrony with the cardiac cycle. All animals then underwent cardiac magnetic resonance imaging to assess ventricular function. RESULTS: All subjects successfully underwent off-pump placement of the epicardial assist device via minithoracotomy. Ejection fraction significantly improved from 29.1% ± 4.8% to 39.6% ± 4.23% (P < 0.001) when compared with pretreatment. End-systolic volume decreased (76.6 ± 13.3 mL vs 62.4 ± 12.0 mL, P < 0.001) and stroke volume increased (28.6 ± 3.4 mL vs 37.9 ± 3.1 mL, P < 0.05) when assisted. No change was noted in end-diastolic volume (105.1 ± 11.4 vs 100.3 ± 12.7). On postmortem examination, mesh fixation and device position were excellent in all cases. No adverse events were encountered. CONCLUSIONS: Directed epicardial assistance improves ventricular function in a porcine ischemic cardiomyopathy model and may provide a safe alternative to currently available ventricular assist device therapies. Further, the technique used for device positioning and fixation suggests that an entirely thoracoscopic approach is possible.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Toracoscopia/métodos , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Imagem Cinética por Ressonância Magnética , Masculino , Pericárdio , Desenho de Prótese , Volume Sistólico , Suínos , Função Ventricular Esquerda
16.
Ann Thorac Cardiovasc Surg ; 19(4): 320-2, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23232300

RESUMO

Intra-and early post-operative aortic injury by pedicle screw is not a rare complication in orthopedic surgery, but aortic penetration by a screw head over a long time period is considered as an uncommon case. There are various surgical management options for thoracic aortic injury caused by malpositioned spinal instruments. We report a case of a patient who underwent minimally invasive graft replacement of the descending thoracic artery for pedicle screw penetration.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Parafusos Ósseos/efeitos adversos , Procedimentos Endovasculares , Migração de Corpo Estranho/cirurgia , Toracotomia , Idoso , Doenças da Aorta/diagnóstico , Doenças da Aorta/etiologia , Aortografia/métodos , Doença Crônica , Remoção de Dispositivo , Feminino , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/etiologia , Humanos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Ann Thorac Cardiovasc Surg ; 17(2): 153-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21597412

RESUMO

OBJECTIVE: The aim of this study was to determine the impact of patient-prosthesis mismatch (PPM) after mitral valve replacement (MVR) on the late clinical outcome, evaluated from the referred value and measured mitral valve area in the echocardiograph. PATIENTS AND METHOD: The records of 212 patients who underwent MVR between 1995 and 2008 at Funabashi Municipal Medical Center, Japan were studied retrospectively. Exclusions were patients who had a repeat MVR or concomitant aortic valve surgery. Of 212 patients, 163 underwent the Doppler echocardiographic study more than 1 year after surgery. Primary endpoint was late survival, and secondary endpoint was major adverse cardiac event (MACE). The average follow-up period was 53.1 ± 100.8 months. The effective orifice area index (EOAI) was calculated using the referred effective orifice area (r-EOA) and measured effective orifice area (m-EOA). An EOAI smaller than 1.2 cm2/m2 defined PPM. RESULTS: For r-EOAI, 125 patients (group P) had PPM and 87 patients (group N) did not. Between groups, there was a significant difference in the proportion of males (group P vs. N; 59% vs. 23%; P = 0.0001), postoperative NYHA class (1.02 ± 6.2 vs. 9.8 ± 1.6, P = 0.04), late mitral valve area (MVA) (2.50 ± 0.56 vs. 2.78 ± 0.60, P = 0.005), and peak transmitral pressure gradient (MPG) 11.9 ± 6.2 vs 9.8 ± 1.6, P = 0.04). However, there was no difference in late survival (P = 0.55) or incidence of a major cardiac adverse event (MACE) (P = 0.14). For m-EOAI, 17 patients (group P) had PPM and 146 patients (group N) did not. Between groups, there was a difference in the bioprosthetic valve (group P vs. N; 76% vs. 26%, P = 0.006) and mean MPG (5.2 ± 2.3 vs. 3.7 ± 1.8, P = 0.02). However, there was no difference in late survival (P = 0.99) and incidence of MACE (P = 0.86). The r- and m-EOAI were well correlated (correlation coefficient 0.46; 0.33-0.5) CONCLUSIONS: The PPM after MVR was not related to the late survival or the incidence of MACE based on both r- and m-EOAI. The patient group of PPM defined by r-EOAI tended to be male and that defined by m-EOAI tended to be bioprosthetic.


Assuntos
Bioprótese , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Idoso , Distribuição de Qui-Quadrado , Ecocardiografia Doppler , Feminino , Cardiopatias/etiologia , Cardiopatias/mortalidade , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Japão , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
18.
Interact Cardiovasc Thorac Surg ; 13(1): 101-3, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21454315

RESUMO

The number of reoperations for prosthetic valve replacement has increased in recent years due to the steady increase in life expectancy. However, reoperations are complex and require experience and skills. We report the case of a 69-year-old female with severe right heart failure who underwent tricuspid valve re-replacement 28 years after the initial tricuspid valve replacement. Cardiopulmonary bypass with vacuum-assisted venous drainage (VAVD) was used to achieve better perfusion flow and heart decompression with smaller venous cannulae. The operation was successful. The VAVD system is effective in patients who have a persistent elevation of central venous pressure.


Assuntos
Ponte Cardiopulmonar/métodos , Remoção de Dispositivo , Drenagem/métodos , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Tricúspide/cirurgia , Idoso , Pressão Venosa Central , Feminino , Artéria Femoral , Veia Femoral , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Veias Jugulares , Desenho de Prótese , Reoperação , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Curetagem a Vácuo
19.
Gen Thorac Cardiovasc Surg ; 58(10): 528-30, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20941567

RESUMO

There have been only a few reports concerning the long-term results of a surgical procedure using a large artificial patch for patients with Williams syndrome. Twelve years have passed since a patient with William's syndrome underwent a surgery with a patch angioplasty for the diffuse supravalvular aortic stenosis and deformities of the neck branch arteries. The patient had a well-balanced aortic growth without stenotic or aneurysmal changes, which was confirmed during the time of the second surgery when replacing the mitral valve. This technique of using a large patch has proven to be safe for Williams syndrome patients with diffuse supravalvular aortic stenosis in the long term.


Assuntos
Aorta/cirurgia , Estenose Aórtica Supravalvular/cirurgia , Implante de Prótese Vascular , Pescoço/irrigação sanguínea , Síndrome de Williams/cirurgia , Adolescente , Aorta/crescimento & desenvolvimento , Estenose Aórtica Supravalvular/genética , Aortografia/métodos , Artérias/anormalidades , Artérias/cirurgia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Constrição Patológica , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Síndrome de Williams/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA