Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Dig Dis ; 40(3): 376-384, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34348294

RESUMO

BACKGROUND: Regular arrangement of collecting venules (RAC) in gastric mucosa accurately identifies patients without Helicobacter pylori (H pylori) infection. The aim of our study was to evaluate the reproducibility of RAC using white light endoscopy without magnification, in a European country, and to assess the impact of proton pump inhibitors (PPIs). METHODS: A multicenter prospective study with image capture of the distal lesser gastric curvature and gastric biopsies was performed. The presence of starfish-like minute points regularly distributed throughout lesser curvature was considered as RAC positive (RAC+). A set of 20 images was used for the training phase and inter and intra-observer agreements were calculated. RESULTS: 174 patients were included and 85 (48.9%) were taking PPIs. Kappa values for interobserver and intra-observer agreements were substantial (0.786) and excellent (0.906), respectively. H. pylori infection was diagnosed in 29 patients (16.7%): 10/85 with PPIs and 19/89 without PPIs (11.8% vs. 21.3%; p = 0.09). All RAC + patients were free of H. pylori infection, with a sensitivity and negative predictive value of 100%, regardless of PPI intake. CONCLUSION: The endoscopic diagnosis of H. pylori by RAC is an easy-to-learn and highly reproducible technique, even with PPI intake. Our results warrant RAC as a real-time diagnostic method for H. pylori-negative infection in Western practice.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Mucosa Gástrica/patologia , Gastroscopia/métodos , Infecções por Helicobacter/diagnóstico , Humanos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Vênulas/patologia
2.
BMC Med ; 18(1): 255, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32943059

RESUMO

BACKGROUND: Colon capsule endoscopy (CCE) and CT colonography (CTC) are minimally invasive techniques for colorectal cancer (CRC) screening. Our objective is to compare CCE and CTC for the identification of patients with colorectal neoplasia among participants in a CRC screening programme with positive faecal immunochemical test (FIT). Primary outcome was to compare the performance of CCE and CTC in detecting patients with neoplastic lesions. METHODS: The VICOCA study is a prospective, single-centre, randomised trial conducted from March 2014 to May 2016; 662 individuals were invited and 349 were randomised to CCE or CTC before colonoscopy. Endoscopists were blinded to the results of CCE and CTC. RESULTS: Three hundred forty-nine individuals were included: 173 in the CCE group and 176 in the CTC group. Two hundred ninety individuals agreed to participate: 147 in the CCE group and 143 in the CTC group. In the intention-to-screen analysis, sensitivity, specificity and positive and negative predictive values for the identification of individuals with colorectal neoplasia were 98.1%, 76.6%, 93.7% and 92.0% in the CCE group and 64.9%, 95.7%, 96.8% and 57.7% in the CTC group. In terms of detecting significant neoplastic lesions, the sensitivity of CCE and CTC was 96.1% and 79.3%, respectively. Detection rate for advanced colorectal neoplasm was higher in the CCE group than in the CTC group (100% and 93.1%, respectively; RR = 1.07; p = 0.08). Both CCE and CTC identified all patients with cancer. CCE detected more patients with any lesion than CTC (98.6% and 81.0%, respectively; RR = 1.22; p = 0.002). CONCLUSION: Although both techniques seem to be similar in detecting patients with advanced colorectal neoplasms, CCE is more sensitive for the detection of any neoplastic lesion. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02081742 . Registered: September 16, 2013.


Assuntos
Endoscopia por Cápsula/métodos , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Rev Esp Enferm Dig ; 109(2): 152-154, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28196424

RESUMO

Pyogenic granuloma is a non-infectious and non-granulomatous lesion. Its location in the small bowel is very rare. We present a 46 year-old woman with a chronic liver disorder that had a severe chronic anemia with occult blood losses. Upper endoscopy and colonoscopy were normal. A small bowel capsule endoscopy showed a pyogenic granuloma in jejunum that was resected endoscopically with single balloon enteroscopy with no major complications. The patient recovered from anemia and six months latter capsule endoscopy did not show lesions.


Assuntos
Endoscopia Gastrointestinal/métodos , Granuloma Piogênico/cirurgia , Doenças do Jejuno/cirurgia , Síndrome da Imunodeficiência Adquirida/complicações , Endoscopia por Cápsula , Feminino , Granuloma Piogênico/diagnóstico por imagem , Hepatite C Crônica/complicações , Humanos , Doenças do Jejuno/diagnóstico por imagem , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA