Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiother Oncol ; 77(1): 25-31, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15919126

RESUMO

BACKGROUND AND PURPOSE: The goal of this study was to compare the inter-observer variability between CT and MRI for the delineation of pharyngo-laryngeal SCC, parotid glands and spinal cord. PATIENTS AND METHODS: Twenty pharyngo-laryngeal tumors were delineated by five observers on CT and MRI, using consistent delineation guidelines. Spinal cords and parotid glands were also delineated on CT and MRI by three observers. Mean GTVs and coefficients of variation were calculated for each observer and compared using ANOVA and its derived Pearson intra-class coefficient (R). For GTVs, a mismatch analysis (ratio between intersection and union volumes) was also performed. RESULTS: Regarding oropharyngeal GTVs (n=10), no significant difference was observed between observers either with CT (33.9, 31.1, 32, 34 and 34.7 ml, five observers, P=0.47) or with MRI (30.5, 29.4, 30.1 and 31.5 ml, four observers, P=0.59). CVs (13.6 vs 12.9%), (0.98 vs 0.99) and mismatches (0.43 vs 0.42) between CT and MRI did not significantly differ. Regarding laryngeal-hypopharyngeal GTVs (n=10), no significant difference was observed between observers either on CT (18.1, 20.7, 20.9, 19.3 and 21.9 ml, five observers, P=0.29) or on MRI (19.3, 21.5, 20, 22.1 and 21.8 ml, five observers, P=0.16). CVs (20.2 vs 13.8%), (0.94 vs 0.94) and mismatches (0.31 vs 0.41) were comparable. Regarding OARs, a small but significant difference in mean parotid volume was observed between observers (P<0.001) and between modalities (P<0.001) (CT: 34.8, 29.4, and 26.8 ml; MRI: 30.6, 27.9 and 20.4 ml). Similar results were obtained for mean spinal cord volumes (CT: 10.7, 10.6, and 9.5 ml; MRI: 8.7, 8.5 and 8.2 ml; P=0.05).


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias Laríngeas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Glândula Parótida/diagnóstico por imagem , Neoplasias Faríngeas/diagnóstico por imagem , Medula Espinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Carcinoma de Células Escamosas/radioterapia , Fracionamento da Dose de Radiação , Humanos , Neoplasias Laríngeas/radioterapia , Variações Dependentes do Observador , Neoplasias Faríngeas/radioterapia , Lesões por Radiação/prevenção & controle , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA