1.
Langmuir ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39039728

RESUMO

An oral sorbent with high capacity for NH4+ is desirable in lowering the blood urea level and mitigating the dialysis burden for end-stage kidney disease (ESKD) patients. Zirconium phosphate (ZrP) is an amorphous cation ion exchanger with high NH4+ binding capacity as a sorbent material, but its selectivity to remove NH4+ is limited in the presence of other competing ions in water solution. We previously have developed a gas-permeable and hydrophobic perfluorocarbon coating on ZrP, which improves ZrP's NH4+ selectivity. However, the coating preparation procedure, a wet chemistry approach, is complicated and time-consuming, and more importantly, the large amount of usage of acetone poses a concern for the application of ZrP as an oral sorbent. In this study, we developed a solventless coating protocol that effectively coats ZrP with tetraethyl orthosilicate (TEOS) and 1H,1H,2H,2H-perfluorooctyltriethoxysilane (FOTS) via thermal vapor deposition (TVD) in a simplified manner. X-ray photoelectron spectroscopy (XPS) and contact angle measurements verify the two coatings are successfully deposited on the ZrP surface, and the coating condition was optimized based on an in vitro static binding study. The dynamic binding study of competing ions on Na-loaded ZrP with TVD coatings yields a maximum NH4+ removal (∼3.2 mequiv/g), which can be improved to ∼4.7 mequiv/g if H-loaded ZrP under the same coating condition is used in basic stock solutions. More importantly, both materials barely remove Ca2+ and show excellent acid resistance. The significant improvement in the NH4+ binding capacity and selectivity reported here establishes a highly promising surface modification approach to optimize oral sorbents for ESKD patients.

2.
Langmuir ; 38(28): 8677-8685, 2022 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35786968

RESUMO

A sorbent with a high enough capacity for NH4+ could serve as an oral binder to lower urea levels in end-stage kidney disease (ESKD) patients. A hydrogen-loaded cation exchanger such as zirconium phosphate Zr(HPO4)2·H2O (ZrP) is a promising candidate for this application. However, the NH4+ binding selectivity versus other ions must be improved. Here, we have developed a gas-permeable and hydrophobic surface coating on an amorphous form of ZrP using tetraethyl orthosilicate and methoxy-terminated polydimethylsiloxane. The hydrophobic coating serves as a barrier to ions in water solution from reaching the ion-exchanger's surface. Meanwhile, its gas-permeable nature allows for gaseous ammonia transfer to the cation exchanger. In vitro studies were designed to replicate the small intestine's expected ion concentrations and exposure time to the sorbent. The effectiveness of the coating was measured with NH4+ and Ca2+ solutions and uncoated ZrP as the negative control. X-ray photoelectron spectroscopy and scanning electron microscopy measurements show that the coating successfully modifies the surface of the cation exchanger─ZrP. Water contact angle studies indicate that coated ZrP is hydrophobic with an angle of (149.8 ± 2.5°). Simulated small intestine solution studies show that the coated ZrP will bind 94% (±11%) more NH4+ than uncoated ZrP in the presence of Ca2+. Meanwhile, Ca2+ binding decreases by 64% (±6%). The nearly fourfold increase in NH4+ selectivity can be attributed to the gas-permeable and hydrophobic coating applied on the ZrP surface. This work suggests a novel pathway to develop a selective cation exchanger for treating ESKD patients.


Assuntos
Compostos de Amônio , Cátions , Humanos , Água , Zircônio/química
3.
Gastroenterology ; 161(3): 865-878.e8, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34116029

RESUMO

BACKGROUND & AIMS: Barrett's epithelium measurement using widely accepted Prague C&M classification is highly operator dependent. We propose a novel methodology for measuring this risk score automatically. The method also enables quantification of the area of Barrett's epithelium (BEA) and islands, which was not possible before. Furthermore, it allows 3-dimensional (3D) reconstruction of the esophageal surface, enabling interactive 3D visualization. We aimed to assess the accuracy of the proposed artificial intelligence system on both phantom and endoscopic patient data. METHODS: Using advanced deep learning, a depth estimator network is used to predict endoscope camera distance from the gastric folds. By segmenting BEA and gastroesophageal junction and projecting them to the estimated mm distances, we measure C&M scores including the BEA. The derived endoscopy artificial intelligence system was tested on a purpose-built 3D printed esophagus phantom with varying BEAs and on 194 high-definition videos from 131 patients with C&M values scored by expert endoscopists. RESULTS: Endoscopic phantom video data demonstrated a 97.2% accuracy with a marginal ± 0.9 mm average deviation for C&M and island measurements, while for BEA we achieved 98.4% accuracy with only ±0.4 cm2 average deviation compared with ground-truth. On patient data, the C&M measurements provided by our system concurred with expert scores with marginal overall relative error (mean difference) of 8% (3.6 mm) and 7% (2.8 mm) for C and M scores, respectively. CONCLUSIONS: The proposed methodology automatically extracts Prague C&M scores with high accuracy. Quantification and 3D reconstruction of the entire Barrett's area provides new opportunities for risk stratification and assessment of therapy response.


Assuntos
Esôfago de Barrett/patologia , Aprendizado Profundo , Mucosa Esofágica/patologia , Junção Esofagogástrica/patologia , Esofagoscopia , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Idoso , Automação , Esôfago de Barrett/classificação , Esôfago de Barrett/terapia , Progressão da Doença , Feminino , Humanos , Masculino , Projetos Piloto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
4.
Dig Dis ; 39(3): 179-189, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33002891

RESUMO

BACKGROUND: Guidelines give robust recommendations on which biopsies should be taken when there is endoscopic suggestion of gastric inflammation. Adherence to these guidelines often seems arbitrary. This study aimed to give an overview on current practice in tertiary referral centres across Europe. METHODS: Data were collected at 10 tertiary referral centres. Demographic data, the indication for each procedure, endoscopic findings, and the number and sampling site of biopsies were recorded. Findings were compared between centres, and factors influencing the decision to take biopsies were explored. RESULTS: Biopsies were taken in 56.6% of 9,425 procedures, with significant variation between centres (p < 0.001). Gastric biopsies were taken in 43.8% of all procedures. Sampling location varied with the procedure indication (p < 0.001) without consistent pattern across the centres. Fewer biopsies were taken in centres which routinely applied the updated Sydney classification for gastritis assessment (46.0%), compared to centres where this was done only upon request (75.3%, p < 0.001). This was the same for centres stratifying patients according to the OLGA system (51.8 vs. 73.0%, p < 0.001). More biopsies were taken in centres following the MAPS guidelines on stomach surveillance (68.1 vs. 37.1%, p < 0.001). Biopsy sampling was more likely in younger patients in 8 centres (p < 0.05), but this was not true for the whole cohort (p = 0.537). The percentage of procedures with biopsies correlated directly with additional costs charged in case of biopsies (r = 0.709, p = 0.022). CONCLUSION: Adherence to guideline recommendations for biopsy sampling at gastroscopy was inconsistent across the participating centres. Our data suggest that centre-specific policies are applied instead.


Assuntos
Endoscopia Gastrointestinal , Encaminhamento e Consulta , Centros de Atenção Terciária , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
J Vasc Surg Venous Lymphat Disord ; 6(2): 154-162, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29292116

RESUMO

BACKGROUND: The common peroneal nerve stimulator (CPNS) is a UK-approved device for reducing venous thromboembolism (VTE) risk. It resembles a wrist watch and is placed over the common peroneal nerve, discharging electricity at a rate of 1 impulse/s. It has been presumed that as blood flow slows, erythrocytes aggregate into ultrasound-detectable echogenic particles, described as venous sludge. The aim of the study was to determine whether the CPNS reduces venous sludge by using an ultrasound-derived gray-scale (0-255) venous sludge index (VSI). METHODS: Twenty-five healthy volunteers had their right popliteal vein video recorded using B-mode ultrasound at 22 frames/s in longitudinal and transverse views, standing and lying. This was performed first with the CPNS off and then with the CPNS on. The CPNS impulse intensity used was set from 1 to 7 for each individual, and the level was sufficient to cause an outward jerking movement of the foot. A single frame of the possible 154 frames, lasting 7 seconds, was selected using a random number generator for the image analysis. The "brightness" of the erythrocyte aggregates (pixels) within a circular sampling area was quantified using the VSI. The brighter the sample, the greater the sludge. RESULTS: Values are expressed as median (interquartile range). On standing with the device off, there was a significantly higher VSI (P < .0005) compared with lying (longitudinal view, 27.7 [18.8-41.4] vs 11.7 [5.5-17.5]; transverse view, 20.7 [13.6-32.2] vs 11.4 [6.3-15.9]). Activation of the CPNS significantly reduced all the VSI values (P < .0005) shown (longitudinal view, 2 [1.1-3.2] and 1.5 [0.5-3.1]; transverse view, 1.1 [0.6-2.7] and 0.8 [0.5-2.1]). CONCLUSIONS: The CPNS device significantly reduces venous sludge within the popliteal vein irrespective of whether the subject is standing or lying down or of the longitudinal or transverse position of the ultrasound transducer. The principal mode of action of the device in the claim that it may reduce venous thromboembolism risk may be through a reduction of venous sludge. However, the relationship between erythrocyte aggregation, venous stasis, and venous thromboembolism risk requires more investigation.


Assuntos
Junção Neuromuscular/fisiologia , Nervo Fibular/fisiologia , Veia Poplítea/inervação , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Projetos Piloto , Veia Poplítea/diagnóstico por imagem , Estudo de Prova de Conceito , Fluxo Sanguíneo Regional , Fatores de Tempo , Estimulação Elétrica Nervosa Transcutânea/instrumentação , Ultrassonografia
6.
Semin Dial ; 26(1): E1-4, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22860886

RESUMO

A 75-year-old man on chronic peritoneal dialysis had unrecognized stenosis of the superior vena cava (SVC) due to pacemaker wires placed 5 years earlier. The patient was placed on hemodialysis after hernia surgery. When a tunneled central venous catheter for dialysis was placed from the right internal jugular (IJ) vein, the venous lumen extended through the stenotic area but not the arterial lumen. Probably due to a subsequent clot at the arterial lumen port the patient developed SVC syndrome and when the catheter was run in the reversed flow direction he developed hypovolemic shock. The stenosis and SVC syndrome resolved with angioplasty of the SVC stenosis, removal of the IJ catheter and use of a femoral vein catheter. The patient eventually returned to peritoneal dialysis and the femoral catheter was removed.


Assuntos
Bradicardia/terapia , Cateteres Venosos Centrais , Falência Renal Crônica/terapia , Marca-Passo Artificial/efeitos adversos , Diálise Peritoneal/métodos , Síndrome da Veia Cava Superior/etiologia , Idoso , Angioplastia/métodos , Bradicardia/complicações , Contraindicações , Remoção de Dispositivo , Falha de Equipamento , Humanos , Falência Renal Crônica/complicações , Masculino , Flebografia , Síndrome da Veia Cava Superior/diagnóstico , Síndrome da Veia Cava Superior/cirurgia , Tomografia Computadorizada por Raios X
8.
Arthroscopy ; 19(9): 931-5, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14608310

RESUMO

PURPOSE: The purpose of this study was to better delineate the anatomy of "resident's ridge," a term coined by William Clancy Jr., M.D., to describe the raised bony landmark commonly visualized just anterior to the femoral attachment of the anterior cruciate ligament (ACL). This landmark can mislead the novice surgeon into misplacing the femoral tunnel of ACL reconstructions. TYPE OF STUDY: Cadaveric anatomic study. METHODS: Ten human distal femurs harvested from embalmed specimens were fixed, sectioned, and analyzed for the presence and descriptive characteristics of resident's ridge. A single, blinded examiner evaluated slope, cortical thickness at 4 sites, and the presence or absence of a distinct ridge relative to the attachment of the ACL. RESULTS: A defined resident's ridge was present in 9 of 10 specimens. This was directly associated with a change in slope of the intracondylar roof in the same 9 of 10 patients. The mean cortical thickness at the ACL attachment site was 1.6 mm. This was thicker than at resident's ridge (mean, 0.90 mm), the cartilage-intercondylar notch junction (mean, 0.96 mm), and a point midway between the ACL attachment and the cartilage-intercondylar notch junction (mean, 0.90 mm). CONCLUSIONS: The phenomenon of "resident's ridge" is accounted for by a distinctive change in slope of the femoral notch roof that occurs just anterior to the femoral attachment of the ACL. The density change apparent at the time of notchplasty is probably caused by the transition between normal cortical thickness just anterior to the ACL and the cortical thickness of the ACL attachment. No distinctive increased cortical thickness can be identified as "resident's ridge."


Assuntos
Ligamento Cruzado Anterior/anatomia & histologia , Antropometria , Fêmur/anatomia & histologia , Ligamento Cruzado Anterior/cirurgia , Humanos , Valores de Referência , Método Simples-Cego
9.
Semin Dial ; 16(4): 323-34, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12839507

RESUMO

The success of chronic peritoneal dialysis (PD) depends to a large extent on the success of the chronic PD access device. For the nephrologist placing and removing PD catheters, or for the nephrologist advising surgeons in this role, this article provides a review of designs of PD catheters and differences in function and complications, methods of insertion of PD catheters and relation to catheter outcomes, techniques for "burying" the external portion of the PD catheter and benefits of this technique, and techniques for removing PD catheters. As nephrologists become more closely involved in the creation, monitoring, and maintenance of access devices for end-stage renal disease (ESRD) patients, the successful function of these devices will increase. Nephrologists should make the critical decisions regarding the choice of access devices and methods for placement as they do for the choice to remove such access devices.


Assuntos
Cateteres de Demora , Diálise Peritoneal , Desenho de Equipamento , Humanos , Laparoscopia , Diálise Peritoneal/instrumentação