Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Am Coll Cardiol ; 76(24): 2847-2858, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33303074

RESUMO

BACKGROUND: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve. OBJECTIVES: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve. METHODS: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve. Patient-related, procedural, and short-term outcomes data were characterized overall and according to type of right ventricular outflow tract (RVOT) anatomy. RESULTS: Twenty-three centers enrolled a total of 774 patients: 397 (51%) with a native/patched RVOT; 183 (24%) with a conduit; and 194 (25%) with a bioprosthetic valve. The S3 was used in 78% of patients, and the XT was used in 22%, with most patients receiving a 29-mm (39%) or 26-mm (34%) valve. The implant was technically successful in 754 (97.4%) patients. Serious adverse events were reported in 67 patients (10%), with no difference between RVOT anatomy groups. Fourteen patients underwent urgent surgery. Nine patients had a second valve implanted. Among patients with available data, tricuspid valve injury was documented in 11 (1.7%), and 9 others (1.3%) had new moderate or severe regurgitation 2 grades higher than pre-implantation, for 20 (3.0%) total patients with tricuspid valve complications. Valve function at discharge was excellent in most patients, but 58 (8.5%) had moderate or greater pulmonary regurgitation or maximum Doppler gradients >40 mm Hg. During limited follow-up (n = 349; median: 12 months), 9 patients were diagnosed with endocarditis, and 17 additional patients underwent surgical valve replacement or valve-in-valve TPVR. CONCLUSIONS: Acute outcomes after TPVR with balloon-expandable valves were generally excellent in all types of RVOT. Additional data and longer follow-up will be necessary to gain insight into these issues.


Assuntos
Procedimentos Endovasculares/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Próteses Valvulares Cardíacas , Valva Pulmonar , Sistema de Registros , Adolescente , Adulto , Bioprótese , Criança , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
2.
J Thorac Cardiovasc Surg ; 155(4): 1712-1724.e1, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29395214

RESUMO

BACKGROUND: Stented bioprosthetic valves (BPVs) are commonly used for surgical pulmonary valve (PV) replacement in postoperative congenital heart disease, but develop structural failure in a time-related fashion. The Melody transcatheter PV (TPV) (Medtronic, Minneapolis, Minn) has been used to treat BPV dysfunction, but there have been few studies in this population. METHODS: We performed a retrospective, multicenter study to evaluate Melody valve function in patients who underwent TPV replacement (TPVR) into a dysfunctional pulmonary BPV. RESULTS: One hundred patients who underwent TPVR at 10 centers between January 2010 and June 2015 were enrolled. The median patient age was 22 years (range, 5-79 years), and 32 patients were age <18 years. The underlying diagnosis was tetralogy of Fallot in 80 patients, and moderate or severe pulmonary regurgitation (PR) was present in 84%. The TPV was implanted into various types of BPVs, with a median size of 23 mm (range, 19-33 mm). At hospital discharge, PR was mild or less in all but 1 patient, and the mean Doppler right ventricular outflow tract (RVOT) gradient was reduced from a mean of 29.3 ± 12.0 mm Hg to 16.2 ± 6.9 mm Hg (median, 29 mm Hg to 16 mm Hg; P < .001). During follow-up (median, 12.4 months), no patients underwent reintervention on the TPV. Endocarditis was diagnosed in 1 patient who was managed medically without intervention. The mean RVOT gradient at the most recent follow-up was ≤35 mm Hg in all patients, and was similar to that at early postimplantation. PR was more than mild in only 1 patient. Hemodynamic outcomes did not differ between patients with small BPVs (≤23 mm) and those with large BPVs (≥25 mm). CONCLUSIONS: TPVR restores competence and relieves the obstruction of dysfunctional surgical BPVs, with excellent early results in both small and large BPVs, highlighting the potential for TPVR to extend the life of existing BPVs in adults and children. Collaboration between surgeons and cardiologists is important to determine the optimal lifetime management, combining surgical PV replacement and TPVR in this population.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
3.
Am J Cardiol ; 121(2): 262-268, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29153244

RESUMO

We sought to describe the acute results and short- to medium-term durability of transcatheter tricuspid valve-in-valve (TVIV) implantation within surgical bioprostheses among patients with Ebstein anomaly (EA). Cases were identified from a voluntary, multicenter, international registry of 29 institutions that perform TVIV. Demographic, clinical, procedural, and follow-up data were analyzed. Eighty-one patients with EA underwent TVIV from 2008 to 2016. Thirty-four patients (42%) were New York Heart Association (NYHA) class 3/4 at time of TVIV. The most common indication for TVIV was the presence of moderate or severe tricuspid regurgitation (40%). Most patients received a Melody valve (64%). TVIV was ultimately successful in all patients, and there was no procedural mortality. Four patients (5%) developed acute valve thrombosis, 4 patients (5%) developed endocarditis, and 9 patients (11%) developed valve dysfunction not related to thrombosis or endocarditis. Eight patients (10%) underwent reintervention (2 transcatheter, 6 surgical) due to thrombosis (3), endocarditis (2), other valve dysfunction (2), and patient-prosthesis mismatch without valve dysfunction (1). Among 69 patients who were alive without reintervention at latest follow-up, 96% of those with NYHA status reported were class 1/2, a significant improvement from baseline (62% NYHA class 1/2, p <0.001). In conclusion, transcatheter TVIV offers a low-risk, minimally invasive alternative to surgical tricuspid valve re-replacement in patients with EA and a failing tricuspid valve bioprosthesis.


Assuntos
Anomalia de Ebstein/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Adolescente , Adulto , Idoso , Bioprótese , Cateterismo Cardíaco/métodos , Anomalia de Ebstein/complicações , Endocardite/epidemiologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Reoperação , Trombose/epidemiologia , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Adulto Jovem
4.
Catheter Cardiovasc Interv ; 89(2): 298-305, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27465501

RESUMO

BACKGROUND: The most common reason for reintervention after a Björk modification of the Fontan procedure, in which the right ventricle (RV) is incorporated into the pulmonary circulation by connecting the right atrial (RA) appendage to the RV directly or with an extra-anatomic graft, is obstruction or regurgitation of the RA-RV connection. Transcatheter implantation of a valved stent is an appealing option for the treatment of RA-RV conduit dysfunction in these patients. In the present study, we assessed early and intermediate results after transcatheter valve implantation within an obstructed or regurgitant RA-RV modified Fontan pathway. METHODS: Through a retrospective multicenter registry, we collected data from 16 patients with a modified Fontan circulation who were treated with percutaneous Melody or Sapien valve implantation for dysfunction of an extra-anatomic RA-RV conduit or valve. RESULTS: All patients had successful and uncomplicated implantation of a Melody (n = 15) or Sapien 3 (n = 1) valve with hemodynamic and, in most cases, clinical improvement. During a median follow-up of 3.3 years, 3 patients died of cardiovascular causes unrelated to the procedure or the valve, and no major valve dysfunction was observed. CONCLUSION: Percutaneous transcatheter valve deployment to treat a dysfunctional RA-RV connection after a Björk modification of the Fontan procedure is a viable alternative to surgery, with low procedural risk, and appears to offer good early and intermediate results.© 2016 Wiley Periodicals, Inc.


Assuntos
Implante de Prótese Vascular , Cateterismo Cardíaco/métodos , Técnica de Fontan/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Adulto , Bioprótese , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Canadá , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Europa (Continente) , Feminino , Técnica de Fontan/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
5.
Neonatology ; 109(3): 190-4, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26780635

RESUMO

BACKGROUND: Pulmonary hypertension (PH) in infants with bronchopulmonary dysplasia (BPD) is associated with increased morbidity and mortality. Elevated levels of N-terminal pro-B-type natriuretic peptide (NT-proBNP) and decreased levels of amino acid precursors of nitric oxide (NO) have been associated with PH, but have not been studied in infants with PH secondary to BPD. OBJECTIVE: The aim of this study was to identify a biochemical marker for PH in infants with BPD. METHODS: Twenty infants, born at <27 weeks' gestational age (GA) and/or with a birth weight (BW) ≤750 g, who met the criteria for BPD at 36 weeks' corrected GA (CGA) were enrolled in this cross-sectional pilot study. A screening echocardiogram was conducted at 36-38 weeks' CGA and plasma NT-proBNP and amino acid levels were obtained within 1 week of the screening echocardiogram. RESULTS: Five infants (25%) had echocardiographic evidence of PH. GA and BW were not significantly different between the 2 groups (a PH group and a No PH group). NT-proBNP was significantly elevated in the PH group (median 1,650 vs. 520 pg/ml; p = 0.001) but citrulline levels were significantly lower (median 21 vs. 36 µmol/l; p = 0.005). Arginine levels were not significantly different between the groups (median 78 vs. 79 µmol/l; p = 1). CONCLUSION: NT-proBNP and the NO precursor citrulline may be cost-effective biochemical markers for screening for the presence of PH in preterm infants who have BPD. If validated in a larger study, such biochemical markers may, in part, replace PH screening echocardiograms in these patients.


Assuntos
Biomarcadores/sangue , Displasia Broncopulmonar/sangue , Hipertensão Pulmonar/sangue , Doenças do Prematuro/sangue , Recém-Nascido Prematuro/sangue , Triagem Neonatal/métodos , Displasia Broncopulmonar/complicações , Displasia Broncopulmonar/diagnóstico por imagem , Estudos Transversais , Ecocardiografia , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Recém-Nascido , Doenças do Prematuro/diagnóstico por imagem , Doenças do Prematuro/fisiopatologia , Masculino , Projetos Piloto
6.
Catheter Cardiovasc Interv ; 85(5): 847-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25257952

RESUMO

Trans-catheter balloon angioplasty is a well-established treatment modality for pulmonary artery (PA) stenosis in children with congenital heart disease. We report a case of an unusual complication where a fistula developed between the left PA and the left atrium during balloon angioplasty in a patient with history of tetralogy of Fallot. This was successfully treated with placement of a covered stent.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Átrios do Coração/lesões , Cardiopatias Congênitas/cirurgia , Doença Iatrogênica , Artéria Pulmonar/lesões , Fístula Vascular/etiologia , Procedimentos Cirúrgicos Vasculares/métodos , Angiografia , Ecocardiografia , Humanos , Lactente , Masculino , Complicações Pós-Operatórias , Reoperação , Stents , Fístula Vascular/diagnóstico , Fístula Vascular/cirurgia
7.
Pacing Clin Electrophysiol ; 36(6): 781-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23305194

RESUMO

As the volume and complexity of catheter ablation of atrial fibrillation (AF) continue to rise, there is increasing attention directed at reducing exposure to ionizing radiation. This has led to the emergence of intracardiac echocardiography (ICE) as a stand-alone imaging modality guiding AF ablation. In addition to directing transseptal puncture, ICE may be used to identify left atrial structures and to guide the manipulation of catheters. ICE may also be used to visualize the esophagus in real-time and to assist with early identification of procedural complications. This review provides detailed step-by-step directions for identification of relevant structures and summarizes the use of ICE during AF ablation.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ecocardiografia/instrumentação , Ecocardiografia/métodos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Desenho de Equipamento , Humanos
8.
J Neurointerv Surg ; 5(6): e42, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23188789

RESUMO

We present a description of retinoblastoma treated with supraselective intra-arterial chemotherapy, demonstrating selective delivery of the infused chemotherapeutic agent into the tumor bed by MRI. A 7-month-old presented with group E (international classification) unilateral retinoblastoma. We treated the patient with several rounds of intra-ophthalmic artery melphalan. Gadolinium was infused along with melphalan to visualize the distribution of this chemotherapeutic drug. Intraoperative MRI was obtained within 15 min after treatment and showed increased enhancement of the tumor and subretinal space. We demonstrate here that supraselective administration of chemotherapy into the ophthalmic artery appears to result in drug delivery to the tumor and subretinal space.


Assuntos
Antineoplásicos Alquilantes/administração & dosagem , Antineoplásicos Alquilantes/uso terapêutico , Meios de Contraste , Sistemas de Liberação de Medicamentos/métodos , Gadolínio , Injeções Intra-Arteriais/métodos , Melfalan/administração & dosagem , Melfalan/uso terapêutico , Artéria Retiniana , Neoplasias da Retina/tratamento farmacológico , Retinoblastoma/tratamento farmacológico , Angiografia Cerebral , Meios de Contraste/administração & dosagem , Seguimentos , Gadolínio/administração & dosagem , Humanos , Lactente , Período Intraoperatório , Angiografia por Ressonância Magnética , Masculino , Descolamento Retiniano/cirurgia , Neoplasias da Retina/patologia , Retinoblastoma/patologia , Resultado do Tratamento , Acuidade Visual
9.
BMJ Case Rep ; 20122012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-23162039

RESUMO

We present a description of retinoblastoma treated with supraselective intra-arterial chemotherapy, demonstrating selective delivery of the infused chemotherapeutic agent into the tumor bed by MRI. A 7-month-old presented with group E (international classification) unilateral retinoblastoma. We treated the patient with several rounds of intra-ophthalmic artery melphalan. Gadolinium was infused along with melphalan to visualize the distribution of this chemotherapeutic drug. Intraoperative MRI was obtained within 15 min after treatment and showed increased enhancement of the tumor and subretinal space. We demonstrate here that supraselective administration of chemotherapy into the ophthalmic artery appears to result in drug delivery to the tumor and subretinal space.


Assuntos
Antineoplásicos Alquilantes/administração & dosagem , Meios de Contraste/administração & dosagem , Gadolínio/administração & dosagem , Melfalan/administração & dosagem , Neoplasias da Retina/tratamento farmacológico , Retinoblastoma/tratamento farmacológico , Antineoplásicos Alquilantes/uso terapêutico , Humanos , Lactente , Imageamento por Ressonância Magnética , Melfalan/uso terapêutico , Artéria Oftálmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA