Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38857878

RESUMO

OBJECTIVE: The decision to convert from catheter to arteriovenous access is difficult yet very important. The ability to accurately predict fistula survival prior to surgery would significantly improve the decision making process. Many previously investigated demographic and clinical features have been associated with fistula failure. However, it is not conclusively understood how reliable predictions based on these parameters are at an individual level. The aim of this study was to investigate the probability of arteriovenous fistula maturation and survival after conversion using machine learning workflows. METHODS: A retrospective cohort study on multicentre data from a large North American dialysis organisation was conducted. The study population comprised 73 031 chronic in centre haemodialysis patients. The dataset included 49 variables including demographic and clinical features. Two distinct feature selection and prediction pipelines were used: LASSO regression and Boruta followed by a random forest classifier. Predictions were facilitated for re-conversion to catheter within one year. Additionally, all cause mortality predictions were conducted to serve as a comparator. RESULTS: In total, 38 151 patients (52.2%) had complete data and made up the main cohort. Sensitivity analyses were conducted in 67 421 patients (92.3%) after eliminating variables with a high proportion of missing data points. Selected features diverged between datasets and workflows. A previously failed arteriovenous access appeared to be the most stable predictor for subsequent failure. Prediction of re-conversion based on the demographic and clinical information resulted in an area under the receiver operating characteristic curve (ROCAUC) between 0.541 and 0.571, whereas models predicting all cause mortality performed considerably better (ROCAUC 0.662 - 0.683). CONCLUSION: While group level depiction of major adverse outcomes after catheter to arteriovenous fistula or graft conversion is possible using the included variables, patient level predictions are associated with limited performance. Factors during and after fistula creation as well as biomolecular and genetic biomarkers might be more relevant predictors of fistula survival than baseline clinical conditions.

3.
J Ultrasound Med ; 43(3): 429-437, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37972197

RESUMO

OBJECTIVES: Several imaging modalities have been suggested for surveillance after fenestrated endovascular aortic repair in general and endoleak detection in specific. In the present project a coded excitation-based ultrasound (B-Flow) was investigated for endoleak detection after complex endovascular aortic repair. METHODS: Patients post complex endovascular aortic repair (FEVAR or T/FEVAR) undergoing follow-up appointments including ultrasonography of the aorta at a vascular and endovascular surgery outpatient center were included in the study. B-Flow was compared with computed tomography angiography (CTA), Duplex ultrasound (DUS), and contrast-enhanced ultrasound (CEUS) regarding agreement and reliability for endoleak detection and characterization. RESULTS: In total, 47 follow-ups were included. They accumulated in a total of 149 imaging investigations. Endoleaks were discovered in 44.7% of B-Flow studies and a majority of these endoleaks were classified as type II. Agreement between B-Flow and other imaging modalities was good (>80.0%) in general. However, with B-Flow 6 and 2 endoleaks would have been missed compared with CEUS and CTA, respectively. Regarding endoleak classification, B-Flow had a strong agreement (94.5%) with CEUS in detected cases. Furthermore, in a limited subset analysis, imaging findings were externally validated using findings from angiography. CONCLUSIONS: Ultrasonography allows for endoleak detection and characterization without an invasive procedure or the use of potentially nephrotoxic contrast medium and can reduce radiation exposure. While CEUS mitigates issues of radiation and nephrotoxicity it still requires the intravenous application of contrast enhancers. Ultrasound coded-excitation imaging such as B-Flow could therefore further simplify endoleak surveillance after fenestrated endovascular aortic repair.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Meios de Contraste , Endoleak/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Reprodutibilidade dos Testes , Ultrassonografia , Resultado do Tratamento
4.
J Clin Med ; 12(11)2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37298053

RESUMO

INTRODUCTION: Fenestrated endovascular aortic repair (FEVAR) has become a popular custom-made treatment option for juxtarenal and pararenal aneurysms. It has been previously investigated whether octogenarians as a distinct subgroup are at increased risk for adverse outcomes after FEVAR. With diverging results and an inconclusive understanding of age as a risk factor in general, an analysis of the historical data of a single center was conducted to add to the available body of evidence and further investigate the effect of age as a continuous risk factor. METHODS: A retrospective data analysis of a prospectively maintained single-center database of all patients who underwent FEVAR at a single department of vascular surgery was performed. The main endpoint was post-operative survival. In addition to association analyses, potential confounders such as co-morbidities, complication rates, or aneurysm diameter were examined. In terms of sensitivity analyses, logistic regression models were created for the dependent variables of interest. RESULTS: During the observation period from April 2013 to November 2020, 40 patients over the age of 80 and 191 patients under the age of 80 were treated by FEVAR. The 30-day survival showed no significant difference between the groups (95.1% in octogenarians and 94.3% in patients under 80 years of age). The sensitivity analyses conducted also showed no difference between the two groups, and complication and technical success rates were comparable. The aneurysm diameter was 67 ± 13 mm in the study group and 61 ± 15 mm in those under 80 years of age. Additionally, the sensitivity analyses showed that age as a continuous variable exhibits no effect on the outcomes of interest. DISCUSSION: In the present study, age was not associated with adverse peri-operative outcomes after FEVAR, including mortality, lower technical success rates, complications, or length of hospital stay. Essentially, the most highly associated factor with hospital and ICU length of stay was time spent in surgery. However, octogenarians had a significantly larger aortic diameter at the time of treatment, which might indicate the potential introduction of bias by pre-interventional patient selection. Nevertheless, the usefulness of research on octogenarians as a distinct subgroup might be questionable regarding the scalability of results, and future studies might focus on age as a continuous risk factor instead.

5.
J Endovasc Ther ; : 15266028231174113, 2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37154408

RESUMO

PURPOSE: Fenestrated endovascular aortic repair (FEVAR) is technically more challenging when performed after a failing EVAR procedure (FEVAR after EVAR). This study aims to assess the technical outcome of FEVAR after EVAR and to identify factors that may influence complication rates. METHODS: A retrospective observational study was conducted at a single department of vascular and endovascular surgery. The rate of FEVAR after EVAR compared to primary FEVAR is reported. Complication and primary unconnected fenestration (PUF) rates as well as survival were assessed for the FEVAR after EVAR cohort. PUF rates and operating time were also compared to all primary FEVAR patients. Patient characteristics and technical factors such as number of fenestrations or use of a steerable sheath were assessed as possible influencers on technical success when performing FEVAR after EVAR. RESULTS: Two hundred and nine fenestrated devices were implanted during the study period (2013 to April 2020). Thirty-five patients (16.7% of all FEVAR patients) had undergone FEVAR after EVAR and were included in the study. Overall survival at last follow-up (20.2±19.1 months) was 82.9% in FEVAR after EVAR patients. Rates of technical failure dropped significantly after 14 procedures (42.9% vs. 9.5%; p=0.03). Primary unconnected fenestrations were seen in 3 cases of FEVAR after EVAR (8.6%) and 14 of 174 primary FEVAR cases (8.0%; p>0.99). Operating time for FEVAR after EVAR was significantly higher than for primary FEVAR (301.1±110.5 minutes vs. 253.9±103.4 minutes; p=0.02). The availability of a steerable sheath was a significant predictor of reduced risk of PUFs, whereas age and gender, number of fenestrations or suprarenal fixation of the failed EVAR did not significantly influence PUF rates. CONCLUSION: Fewer technical complications were seen over the study period in FEVAR after EVAR patients. While rates of PUFs were not different from primary FEVAR, operating time was significantly longer in patients undergoing FEVAR for failed EVAR. Fenestrated EVAR can be a valuable and safe tool to treat patients with progression of aortic disease or type Ia endoleak after EVAR but may be more complex to achieve than primary FEVAR. CLINICAL IMPACT: This retrospective study assesses the technical outcome of fenestrated endovascular aortic repair (fenestrated EVAR; FEVAR) after prior EVAR. While rates of primary unconnected fenestrations were not different from primary FEVAR, operating time was significantly longer in patients undergoing FEVAR for failed EVAR. Fenestrated EVAR after prior EVAR may be technically more challenging than primary FEVAR procedures, but could be performed with equally good results in this patient cohort. FEVAR offers a feasible treatment option for patients with progression of aortic disease or type Ia endoleak after EVAR.

6.
Eur Surg ; 55(3-4): 84-88, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37206193

RESUMO

Background: Intimate knowledge of the materials used in endovascular aortic interventions is essential for trainees and supporting staff taking part in an endovascular intervention. Training courses can help to familiarize trainees with the equipment. However, the pandemic has changed the landscape of hands-on training courses significantly. Therefore, we developed a training course including an educational recording of the procedure to transfer knowledge about the materials used during endovascular interventions and radiation exposure reduction. Methods: We produced a video depicting cannulation of the left renal artery in a silicon cast of an aorta and its major side branches under C­arm fluoroscopy. A presentation using the video was given to the trainees. The trainees were randomized into a control and an intervention group. Their performance was filmed and rated on a standardized five-point scale in the style of the OSATS global rating scale. The intervention group was remeasured after additional training time. Results: In total, 23 trainees participated in the training and agreed to have their performance recorded. The control and intervention groups showed no difference in the assessed performance metrics during their initial attempt. However, after receiving additional training, the intervention group significantly improved in all evaluated metrics. Conclusion: Our data add to the growing evidence that simulator-based training can help to increase trainees' understanding and performance of relevant skills. A standardized and evidence-based validation process for simulators could improve their acceptance in the medical field.

7.
J Clin Med ; 12(3)2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36769679

RESUMO

Personalized medicine and precision medicine are terms often used to refer to treatment strategies tailored specifically to individual characteristics of patients, as opposed to a one-size fits all approach [...].

8.
Gefasschirurgie ; 27(5): 361-364, 2022.
Artigo em Alemão | MEDLINE | ID: mdl-36060552

RESUMO

The establishment of new surgical methods and techniques is associated with a learning curve which can lead to a higher morbidity and mortality for patients during training. To counteract this problem, within the framework of surgical and endovascular training and to transfer the learning curve from the patients to the simulator, life-like models are used and tested. The benefits of such simulator training have been shown in multiple disciplines. This article presents the steps from the conception to the production and validation of a simulator for ultrasound-guided arterial and venous puncture. The goal was to develop a cost-efficient high-fidelity simulator that enables ultrasound-guided percutaneous vascular puncture, direct haptic and visual feedback and the use of some percutaneous devices in a manner as complete and life-like as possible. The finished prototype enables an ultrasound-guided puncture of arteries and veins and the model enables the deployment of endovascular devices and closure systems. To be able to provide and carry out a structured training removed from external influences and challenges is in the interest of clinical departments, trainees and ultimately patient safety. Simulation training on life-like models can provide a valuable contribution in this context and represents a welcome supplement to traditional clinical training.

9.
J Vasc Surg ; 75(1): 99-108.e2, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34425192

RESUMO

OBJECTIVE: A crucial step in designing fenestrated stent grafts for treatment of complex aortic abdominal aneurysms is the accurate positioning of the fenestrations. The deployment of a fenestrated stent graft prototype in a patient-specific rigid aortic model can be used for design verification in vitro, but is time and human resources consuming. Numerical simulation (NS) of fenestrated stent graft deployment using the finite element analysis has recently been developed; the aim of this study was to compare the accuracy of fenestration positioning by NS and in vitro. METHODS: All consecutive cases of complex aortic abdominal aneurysm treated with the Fenestrated Anaconda (Terumo Aortic) in six European centers were included in a prospective, observational study. To compare fenestration positioning, the distance from the center of the fenestration to the proximal end of the stent graft (L) and the angular distance from the 0° position (C) were measured and compared between in vitro testing (L1, C1) and NS (L2, C2). The primary hypothesis was that ΔL (|L2 - L1|) and ΔC (|C2 - C1|) would be 2.5 or less mm in more than 80% of the cases. The duration of both processes was also compared. RESULTS: Between May 2018 and January 2019, 50 patients with complex aortic abdominal aneurysms received a fenestrated stent graft with a total of 176 fenestrations. The ΔL and ΔC was 2.5 mm or less for 173 (98%) and 174 (99%) fenestrations, respectively. The NS process duration was significantly shorter than the in vitro (2.1 days [range, 1.0-5.2 days] vs 20.6 days [range, 9-82 days]; P < .001). CONCLUSIONS: Positioning of fenestrations using NS is as accurate as in vitro and could significantly decrease delivery time of fenestrated stent grafts.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Modelos Cardiovasculares , Complicações Pós-Operatórias/epidemiologia , Stents/efeitos adversos , Aorta Abdominal/anatomia & histologia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Simulação por Computador , Humanos , Modelos Anatômicos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
10.
Interact Cardiovasc Thorac Surg ; 33(3): 448-454, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-33993285

RESUMO

OBJECTIVES: The aim of this study was to present a multicentre experience of technical results and mid-term follow-up using a custom-made iliac fenestrated device (Terumo Aortic, Inchinnan, Renfrewshire, UK) for the treatment of iliac aneurysms and endoleaks. METHODS: A multicentre retrospective evaluation of 22 patients (3-12 per institution) with either an iliac artery aneurysm or endoleak treated with an iliac fenestrated device was performed. Data were gathered from 3 departments of vascular and endovascular surgery at 3 European institutions. RESULTS: Ten of the included patients (45.5%) were treated for an endoleak and 12 had aorto-iliac aneurysms (54.5%). Two patients underwent bilateral fenestrated device implantation for a total of 24 devices included in this analysis. Primary technical success was 91.7% (22 of 24 implanted devices). One of the 24 internal iliac arteries could not be cannulated and was covered (primary assisted technical success rate 95.8%) and 1 patient required a relining of the stent graft due to a mid-grade stenosis opposite the internal iliac artery fenestration. Survival at the last available follow-up (mean 15.2 ± 12.0 months, range 0.5-36.6 months) was 90.9%. CONCLUSIONS: The present investigation adds to a growing body of literature on custom-made endografts and their usefulness in achieving endovascular repair without compromising blood flow via important arterial branch vessels, such as the internal iliac artery. It presents encouraging technical and mid-term follow-up data from consecutive patients treated for iliac aneurysms or endoleaks using this custom-made device. The technique may help avoid adverse sequelae associated to a coil-and-cover approach when iliac branch devices are not feasible.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Stents , Resultado do Tratamento
11.
Interact Cardiovasc Thorac Surg ; 32(3): 460-466, 2021 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-33221882

RESUMO

OBJECTIVES: The Medtronic Endurant II stent graft has recently received Conformité Européenne (CE) approval for the use in chimney endovascular aortic repair (ChEVAR) for the treatment for juxtarenal aortic aneurysms. The aim of this study was to assess the percentage of patients treated by fenestrated endovascular repair who would have been alternatively suitable for the treatment by the CE approved Medtronic ChEVAR. METHODS: Preoperative computed tomography scans of 100 patients who underwent fenestrated endovascular aortic repair (FEVAR) between April 2013 and February 2017 were retrospectively assessed for the applicability of the ChEVAR technique according to the Medtronic instructions for use. Eligibility criteria included an aortic neck diameter of 19-30 mm, a minimum infrarenal neck length of 2 mm, a total proximal sealing zone of at least 15 mm, thrombus in the aortic neck in ˂25% of the circumference, and maximum aortic angulations of 60° in the infrarenal, 45° in the suprarenal segment and ˂45° above the superior mesenteric artery. RESULTS: According to CE-approved inclusion criteria, 19 individuals (19%) would have been eligible for ChEVAR. In 81 patients, at least 1 measure was found outside instructions for use: (i) excluding factor was detected in 26 patients, (ii) incongruous measures in 28 patients and in 27 patients, 3-5 measures were outside the instructions for use. The most frequently identified excluding factor was an insufficient infrarenal neck at ˂2 mm length (n = 63; 63%). CONCLUSIONS: Patients with juxta- or pararenal aneurysm treated by FEVAR are in 19% of the cases alternatively suitable for the treatment by ChEVAR within CE-approved instructions for use. While ChEVAR is suitable in many emergency cases, FEVAR offers a broader applicability in an elective setting.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Procedimentos Endovasculares/métodos , Desenho de Prótese/métodos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
12.
Diab Vasc Dis Res ; 17(5): 1479164120930589, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32589047

RESUMO

BACKGROUND: In many cases, Ilomedin® infusions are applied as part of a perioperative measure in patients with peripheral arterial occlusive disease because it makes a relevant vasodilatatory effect in patients with type 2 diabetes mellitus and with/without peripheral neuropathy. AIMS: A prospective case-control study was performed to investigate the effect of prostanoids on peripheral resistance in patients with type 2 diabetes mellitus and patients without type 2 diabetes mellitus, as well as the role of peripheral neuropathy in patients undergoing arterial reconstruction. METHODS: Sixty patients undergoing arterial reconstruction were enrolled. Sufficient data were collected on 38 patients. Prior to surgery, peripheral nerve conduction velocity was measured. Blood flow volume at the common femoral artery was assessed intraoperatively using a Doppler flowmeter at four time points: at baseline before arterial reconstruction (T0), after reconstruction (T1), after 5 (T2) and 10 min (T3) after intra-arterial application of 3000 ng of Ilomedin. Peripheral resistance units were calculated as a function of mean arterial pressure and flow volume using the following formula: peripheral resistance unit = mean arterial pressure (mm Hg) / flow volume (mL/min). RESULTS: Ilomedin produced an immediate and significant drop of peripheral resistance in patients without type 2 diabetes mellitus as well as in patients with type 2 diabetes mellitus. Patients with peripheral neuropathy showed a less pronounced effect to Ilomedin compared to individuals with normal nerve conduction velocity.


Assuntos
Diabetes Mellitus Tipo 2/fisiopatologia , Iloprosta/administração & dosagem , Doença Arterial Periférica/tratamento farmacológico , Doença Arterial Periférica/cirurgia , Resistência Vascular/efeitos dos fármacos , Procedimentos Cirúrgicos Vasculares , Vasodilatação/efeitos dos fármacos , Vasodilatadores/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/diagnóstico , Feminino , Humanos , Iloprosta/efeitos adversos , Infusões Intra-Arteriais , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Vasodilatadores/efeitos adversos , Adulto Jovem
13.
J Surg Educ ; 77(5): 1271-1278, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32205111

RESUMO

OBJECTIVE: The current study assesses the feasibility of in vitro practice of percutaneous puncture techniques in a pulsatile flow-model. DESIGN: Prospective, controlled, randomized study. SETTING: The percutaneous access to endovascular aortic repair is considered safe, but success rates may be dependent on surgeon experience with the technique. PARTICIPANTS: Fourteen vascular surgery trainees and consultants were enrolled and randomized to a study or control group with both groups receiving instructions by a tutor on how to perform ultrasound guided percutaneous puncture and closure using a suture-mediated closure device. The study group received additional hands-on training on a pulsatile flowmodel of the groin and the performance of both groups was then graded. Study group participants were timed during and after their training on the model. RESULTS: The study group achieved higher overall grading than the control group on a 5-point scale with higher scores indicating a better performance (mean overall scores 4.0 ± 0.7 versus 2.8 ± 1.0, respectively; p = 0.03). Experienced participants (more than 20 punctures performed before the study) achieved higher overall scores than trainees (3.8 ± 0.4 versus 2.5 ± 0.8, respectively; p = 0.01). Five participants in the study group could deploy and close the ProGlide closure device correctly without the help of a tutor while being graded (71% in the study versus 0% in the control group; p = 0.02). Study group participants improved their overall score from 3.2 ± 0.9 to 4.0 ± 0.7 during training (p = 0.02). Time needed to complete the puncture and closure reduced from 456 seconds on average before, to 302 seconds after training (p < 0.001). CONCLUSIONS: Study group participants could improve their overall score while working on the simulator. More experienced participants performed better during the simulation, which may indicate the model to be life-like and a potential skills assessment tool. Simulation training may be a valuable adjunct to traditional forms of training when teaching an endovascular technique but is limited by its reliance on simulators and demo devices.


Assuntos
Procedimentos Endovasculares , Artéria Femoral , Artéria Femoral/diagnóstico por imagem , Humanos , Estudos Prospectivos , Punções , Resultado do Tratamento , Ultrassonografia de Intervenção
14.
Ann Vasc Surg ; 66: 160-170, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31978487

RESUMO

BACKGROUND: Although recent data on the treatment of thoracoabdominal aortic aneurysms (TAAAs) are promising, in some cases, the paravisceral segment of the aorta may not be suitable for a branched endograft due to space restrictions. A combination of a fenestrated aneurysm repair (FEVAR) with a thoracic aneurysm repair (TEVAR) may represent a feasible treatment option. The current investigation was performed to assess the stability of a fenestrated Anaconda device implanted into a set of thoracic endografts from different manufacturers. We then assessed our clinical results with the FEVAR/TEVAR combination. METHODS: Pull-out forces were measured in vitro after docking a fenestrated Anaconda graft within the distal end of different TEVAR devices. Anaconda devices were implanted in 28- or 30-mm thoracic tube grafts (oversizing of at least 2 mm: 13.3-21.4; minimum overlap of 15 mm). Continuously increasing longitudinal pull forces of up to 100 N were applied on an Instron Tensile Tester. Initial break point and damage to the endografts were documented. Clinical results of patients treated with such an FEVAR/TEVAR combination at our institution are presented as a second part of this study. RESULTS: Median pull-out forces ranged from 2.38 N to 55.0 N. The highest stability was achieved with 34-mm Anaconda devices in 28-mm thoracic tube grafts. Grafts with either thinner Dacron material or those featuring a polytetrafluorethylene membrane seemed especially vulnerable to punctures and tears caused by the downward-looking hooks of the Anaconda device. Between April 1, 2013 and December 31, 2018, in 28 of 172 patients treated with a fenestrated Anaconda device, prior implantation of a thoracic tube graft was necessary to create a sufficient proximal landing zone. In 25 cases (89.3%), the aneurysm was successfully treated. Although the 30-day reintervention rate in this subgroup was relatively high at 28.6%, none of these was due to a failure of the FEVAR/TEVAR combination. Upon an average follow-up of 15 months, no failure of the graft connection and no type III endoleak due to membrane damage were observed. CONCLUSIONS: The combination of a thoracic tube graft and a fenestrated Anaconda device is a viable option for the treatment of patients with Extent I or IV TAAAs with no adequate landing zone above the celiac trunk. Although pull-out testing has shown good stability with most assessed grafts, the thoracic devices with thicker Dacron membranes seemed to be especially suitable.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Falha de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Bases de Dados Factuais , Endoleak/etiologia , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Análise de Falha de Equipamento , Feminino , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Polietilenotereftalatos , Politetrafluoretileno , Desenho de Prótese , Estudos Retrospectivos , Estresse Mecânico , Resistência à Tração , Resultado do Tratamento
15.
Eur J Vasc Endovasc Surg ; 58(6): 831-838, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31615695

RESUMO

OBJECTIVES: At 12 months follow up of the PLIANT study, clinical success and efficacy of the E-liac Stent Graft System (JOTEC GmbH, Hechingen, Germany) were evaluated. Clinical success was defined as aneurysm exclusion (no type I, III, IV endoleak) with primary patency of the internal iliac artery (IIA) and external iliac artery (EIA) on the E-liac implantation side. METHODS: In this prospective multicentre European observational study, clinical and morphological data of 45 patients (93% male, mean age 72 y) were prospectively collected in 11 European centres between July 2014 and June 2016. Forty patients underwent an aorto-iliac (three patients bilaterally) treatment and five an isolated iliac treatment. RESULTS: At 12 months follow up, data were available for 42 patients. Overall clinical success at 12 months was 90%, with a survival rate of 100%. Four patients (10%) did not achieve clinical success, one with an internal iliac artery (IIA) occlusion on the E-liac implantation side, one with an infrarenal type Ia endoleak, and two with type Ib endoleaks in IIA. At 12 months the primary patency rate in the internal iliac artery on the iliac side branch implantation side was 98%. Two patients (5%) received E-liac related re-interventions: one caused by an edge stenosis at the distal end of the graft limb in the external iliac artery (EIA) and one caused by thrombo-embolism in the external iliac artery. Thus, for the EIA, primary and secondary patency rates were 98% and 100%, respectively. CONCLUSIONS: The low device related re-intervention rate of 5%, the high survival rate of 100%, and the high primary patency rates of 98% for the IIA and EIA at 12 month follow up demonstrate the safety and efficacy of the E-liac Stent Graft System. Long term 36 month results are awaited to confirm the efficacy and durability.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Endoleak/epidemiologia , Procedimentos Endovasculares/instrumentação , Oclusão de Enxerto Vascular/epidemiologia , Aneurisma Ilíaco/cirurgia , Stents Metálicos Autoexpansíveis/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação/estatística & dados numéricos , Resultado do Tratamento
16.
J Vasc Surg ; 70(4): 1107-1114, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31147136

RESUMO

OBJECTIVE: Internal iliac artery aneurysm (IIAA) is a rare entity. Its treatment can be technically challenging. The aim of this study was to evaluate the treatment possibilities in an era of advanced endovascular techniques and their potential to preserve iliac blood flow while reliably excluding the aneurysm. METHODS: A retrospective analysis of 46 consecutive patients with endovascularly treated IIAA was performed. Data were collected from a single-institution aortoiliac database. The following end points were recorded: technique of aneurysm exclusion, technical success rates, perioperative morbidity and mortality, primary patency, and midterm follow-up. RESULTS: Between September 2009 and May 2016, a total of 46 patients with 55 IIAAs were identified. The majority of patients (n = 39 [84.8%]) had aortoiliac aneurysms and seven had isolated IIAAs (15.2%). The following surgical techniques were used: implantation of iliac branch devices (IBDs; n = 29), occlusion of the internal iliac artery (IIA) by ostium coverage with or without prior coil embolization (n = 23), and other endovascular techniques (n = 3). Primary assisted technical success was achieved in 93.1% of IBD implantations and in 100% of occlusions by ostium coverage and other techniques. Overall 30-day mortality was 4.3% (n = 2) and 0% in electively treated patients. Assisted midterm patency after IBD implantation was 93.1%. Gluteal claudication occurred in seven patients (15.2%) who had undergone intentional or accidental occlusion of the IIA or the superior gluteal artery. Reintervention rates within the midterm follow-up were 13.8% (n = 4) after IBD implantation and 4.3% (n = 1) after coverage of the IIA ostium. No ruptures were observed during follow-up, and no complications occurred during reinterventions. CONCLUSIONS: Implantation of IBD devices for the treatment of hypogastric artery aneurysms shows good technical results with a high primary patency and a low rate of perioperative complications. Although successful aneurysm exclusion while preserving pelvic blood flow is associated with a higher rate of reinterventions during midterm follow-up, it should be taken into consideration, especially in complex endovascular aortoiliac aneurysm repair.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Embolização Terapêutica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
17.
J Stroke Cerebrovasc Dis ; 28(6): 1540-1545, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30952532

RESUMO

BACKGROUND: Stroke is one of the leading causes of morbidity and mortality. Thromboembolism, as a major cause of carotid artery-related stroke, can be caused by plaque rupture which is associated with neoangiogenesis within the carotid plaque. AIM: We sought to investigate a possible correlation between angiogenesis-related factors and preoperative neurological manifestations in patients with internal carotid artery stenosis, for a better understanding of thromboembolism in internal carotid artery stenosis-related stroke. METHODS: This study included 54 patients (asymptomatic, n = 20 and symptomatic, n = 34) undergoing carotid endarterectomy for high-grade internal carotid artery stenosis. In the retrieved carotid plaques, angiogenesis-related factors (vascular endothelial growth factor [VEGF], hypoxia inducible factor-1 alpha [HIF-1α], and Clusterin) were measured by immunohistochemistry and quantified by real-time polymerase chain reaction. RESULTS: We demonstrated the expression of VEGF, HIF-1α, and Clusterin by endothelial cells and smooth muscle cells in the carotid plaques. Noteworthy, mRNA VEGF levels were .7-fold higher in symptomatic patients (P = .017) compared to asymptomatic patients. In contrast, mRNA Clusterin levels were 1.8-fold lower (P = .021). Levels of mRNA HIF-1α were 1.5-fold higher in asymptomatic patients, but no statistical significance was reached between the 2 groups. CONCLUSIONS: Our results show an association between VEGF and Clusterin and neurological symptoms of patients with high-grade carotid artery stenosis.


Assuntos
Artéria Carótida Interna/química , Estenose das Carótidas/metabolismo , Clusterina/análise , Subunidade alfa do Fator 1 Induzível por Hipóxia/análise , Placa Aterosclerótica , Fator A de Crescimento do Endotélio Vascular/análise , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Artéria Carótida Interna/patologia , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/complicações , Estenose das Carótidas/patologia , Estenose das Carótidas/cirurgia , Clusterina/genética , Feminino , Regulação da Expressão Gênica , Humanos , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica , Estudos Prospectivos , RNA Mensageiro/genética , Ruptura Espontânea , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fator A de Crescimento do Endotélio Vascular/genética
18.
Vasc Endovascular Surg ; 53(3): 246-249, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30514183

RESUMO

Iliac branch devices (IBDs) are undergoing rapid popularization. They allow for treatment of an iliac aneurysm while preserving blood flow to the hypogastric artery. Certain anatomic criteria are necessary for the use of an iliac side branch device to be technically feasible. Custom-made fenestrated iliac stent grafts may provide an alternative when anatomic criteria for an IBD are not met.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Stents , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Masculino , Desenho de Prótese , Fluxo Sanguíneo Regional , Resultado do Tratamento
19.
Vascular ; 27(1): 46-50, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30205778

RESUMO

OBJECTIVE: Custom-made fenestrated aortic endografts allow exclusion of pararenal aortic aneurysms while maintaining blood flow to aortic branches. Meticulous device planning and precise deployment of the main body are essential to allow successful cannulation of the fenestrations. This study investigates whether a learning curve can be observed with more reliable cannulation and connection of fenestrations over time at a single department of vascular and endovascular surgery with multiple surgeons trained to use the device. METHODS: A retrospective analysis of data from all patients undergoing primary fenestrated endovascular aneurysm repair during the study period was performed. Outcome measures included case volume and average number of fenestrations over time, average fluoroscopy dose area product per calendar year and primary unconnected fenestration and 30-day mortality rates. RESULTS: Between 1 January 2013 and 31 December 2016, 89 patients with no history of endovascular aneurysm repair underwent fenestrated endovascular aneurysm repair at our institution. The number of fenestrations per case increased over time, averaging 2.6 in 2013 and 3.3 in 2016. Primary unconnected fenestration and 30-day mortality rates were 5.6%. Primary-assisted technical success was 93.3%, secondary-assisted technical success was 94.4%. Fluoroscopy dose area product declined over the study period. Thirty-day mortality and primary unconnected fenestration rates did not significantly change over the study period. CONCLUSION: Albeit the reduction in lethal complications and primary technical success rates were not statistically significant, a lower percentage of unconnected fenestrations and 30-day mortality per calendar year were observed over time. At the same time, an increasing complexity of performed cases, as reflected by an increasing number of fenestrations per case, was observed. Complications associated with this complex endovascular procedure are potentially lethal and remain an unfortunate reality and may not be entirely dependent on overcoming a learning curve. A higher volume of cases performed over the study period and a reduction in fluoroscopy use can be considered a representation of the institutional development and learning curve for the Anaconda fenestrated endograft at a department with prior complex endovascular aortic repair experience, but due to limitations of the current retrospective observation, deserve further consideration in future trials, ideally designed in a prospective fashion.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Competência Clínica , Procedimentos Endovasculares/instrumentação , Curva de Aprendizado , Desenho de Prótese , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Vasc Endovascular Surg ; 53(2): 165-169, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30336737

RESUMO

PURPOSE:: To increase awareness of the clinical presentation, diagnostic workup, and treatment options for endograft infections. CASE REPORT:: A 75-year-old male patient was admitted with suspected endograft infection 4 years after endovascular aortic aneurysm repair (EVAR). Although preoperative diagnostics showed no definitive signs of endograft infection, eventual surgical exposure of the endograft revealed signs of advanced inflammation, including the unexpected finding of an aortoduodenal fistula. CONCLUSION:: A detailed evaluation of patient history and clinical examination, performed as a part of routine follow-ups, may be beneficial in identifying possible severe complications after EVAR early on. Regarding options for aortic reconstruction in case of endograft infection, bovine pericardium deserves consideration as a promising, feasible, and easily available graft material.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Remoção de Dispositivo , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Fístula Intestinal/cirurgia , Infecções Relacionadas à Prótese/cirurgia , Fístula Vascular/cirurgia , Idoso , Aneurisma da Aorta Abdominal/diagnóstico , Biópsia , Humanos , Fístula Intestinal/diagnóstico por imagem , Fístula Intestinal/microbiologia , Masculino , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Reoperação , Resultado do Tratamento , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA