Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Top Companion Anim Med ; 45: 100559, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34273586

RESUMO

We describe a case of congenital duplication involving urogenital organs, pelvis and tail in a dog diagnosed by ultrasound scanning, retrograde urethrocystography, and excretory urography. Left nephrectomy, cystectomy, urethral resection, orchidectomy, penectomy, and caudectomy were the treatment options for this case. No spine or intestinal alteration was observed by radiography. After the surgery, the patient condition was assessed for one year. No significant changes were observed in ambulation or in laboratory test results during this period, including normal urination. The patient is currently 6 years old, and is in good condition and with quality of life.


Assuntos
Qualidade de Vida , Cauda , Animais , Cães , Masculino , Pelve , Uretra , Urografia
2.
Ciênc. rural ; 47(5): e20160740, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839806

RESUMO

ABSTRACT: The aim of the present study was to assess heart rate variability (HRV) in Boxer dogs affected by arrhythmogenic right ventricular cardiomyopathy (ARVC). Fourteen Boxer dogs classified as affected and 28 classified as unaffected were included in a prospective case-control study. Dogs underwent 24-hour ambulatory ECG and were classified as affected (>1,000 VPCs/24 hours) or unaffected (<20 VPCs/24 hours) by ARVC based on the number of ventricular arrhythmias. HRV was assessed using 24-h Holter ECG monitoring; the studied parameters were SDNN, SDANN, SDNNIDX, rMSSD and pNN50. Data were submitted to logarithmic transformation and HRV parameters were compared between groups and correlated according to the disease status, number and severity of ventricular arrhythmias using Student’s t test, linear regression and Spearman’s test. There was no interaction between the HRV parameters and the number and severity of ventricular arrhythmias. SDNNlog (2.35±0.14 vs. 2.46±0.12, P=0.01), SDNNIDXlog (2.18±0.14 vs. 2.24±0.10, P=0.002) and pNN50log (1.47±0.19 vs. 1.64±0.13, P=0.002) were significantly lower in the affected group compared with the unaffected. According to this study, HRV are different in a population of Boxers dogs affected by ARVC compared to a population of unaffected dogs, and these differences are not consequences of low cardiac output caused by ventricular arrhythmias since animals that had higher number and complexity of arrhythmias were not those who had lower values of HRV.


RESUMO: O objetivo do presente estudo foi avaliar a variabilidade da frequência cardíaca (VFC) em cães da raça Boxer acometidos pela cardiomiopatia arritmogênica do ventrículo direito (CAVD). Para isso, foram incluídos, em estudo prospectivo caso-controle, 14 cães classificados como acometidos pela CAVD e 28 classificados como não acometidos. Os cães foram submetidos à eletrocardiografia ambulatorial de 24 horas e então classificados como acometidos (quando apresentaram mais de 1.000 complexos ventriculares prematuros em 24 horas) ou não acometidos (quando apresentaram menos de 20 complexos ventriculares prematuros em 24 horas) pela CAVD, com base no número de arritmias ventriculares. A VFC foi avaliada mediante monitoramento Holter de 24 horas. Os parâmetros estudados foram SDNN, SDANN, SDNNIDX, rMSSD e pNN50. Os dados foram submetidos à transformação logarítmica e os parâmetros da VFC foram comparados e correlacionados de acordo com a presença ou não da doença, número e severidade das arritmias pelo teste t de Student, regressão linear e teste de Spearman. Não houve interação entre as variáveis da VFC e o número e a severidade das arritmias ventriculares. Porém, as variáveis SDNNlog (2,35±0,14 vs. 2,46±0,12, P=0,01), SDNNIDXlog (2,18±0,14 vs. 2,24±0,10, P=0.002) e pNN50log (1,47±0,19 vs. 1,64±0,13, P=0,002) foram significativamente menores no grupo de animais acometidos pela doença. De acordo com os resultados do presente estudo, a VFC é menor nos Boxers acometidos pela CAVD em relação aos cães não acometidos, e essa diferença não pode ser atribuída ao baixo débito cardíaco, supostamente causado pelas arritmias ventriculares, uma vez que os animais que apresentaram maior número e complexidade das arritmias não foram os que apresentaram os menores valores da VFC.

3.
Top Companion Anim Med ; 31(4): 130-133, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28317613

RESUMO

Retrospective study based on data extracted from medical records of dogs diagnosed with perineal hernia between 2009 and 2014; medical records of bitches were selected for further analysis to determine the prevalence of perineal hernias in bitches and to investigate potential comorbidities. Perineal hernia was diagnosed in 182 dogs (174 males and 8 females; 96% and 4%, respectively). Surgical correction was performed in 6 bitches. Surgical procedures corresponded to internal obturator muscle transposition with or without polypropylene mesh reinforcement (n = 5) and semitendinosus muscle transposition flap (n = 1). Major comorbidities associated with perineal hernias in adult bitches were trauma (n = 3; 7.3 ± 1.5 years; 7.1 ± 8.5kg) and persistent cough secondary to conditions such as bronchitis, tracheal collapse, and cardiopathy in aged, small-sized patients (n = 3; 13.6 ± 2.0 years; 2.3 ± 0.1kg). Perineal hernias are uncommon in bitches and tend to be associated with comorbidities in these patients. Aged female dogs suffering from uncontrolled chronic cough secondary to cardiopathy or bronchitis are at risk of developing perineal hernia. Previous trauma to the pelvis is another potential risk factor for perineal hernia development in female dogs.


Assuntos
Doenças do Cão/cirurgia , Hérnia Abdominal/veterinária , Períneo/cirurgia , Animais , Comorbidade , Cães , Feminino , Hérnia Abdominal/complicações , Herniorrafia/veterinária , Masculino , Estudos Retrospectivos , Retalhos Cirúrgicos/veterinária
4.
Ciênc. rural ; 43(6): 1102-1106, jun. 2013. tab
Artigo em Inglês | LILACS | ID: lil-675738

RESUMO

To evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40) and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40) were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction.


Com o objetivo de avaliar a importância da eletrocardiografia de alta resolução no diagnóstico da cardiomiopatia arritmogênica do ventrículo direito do Boxer, 20 cães sem evidências de doença cardíaca estrutural à avaliação ecodopplercardiográfica foram agrupados de acordo com a frequência de arritmias ventriculares, avaliadas pela eletrocardiografia ambulatorial de 24 horas, e submetidos ao exame eletrocardiográfico de alta resolução. Duração do complexo QRS filtrado, duração dos sinais de baixa amplitude (menor que 40µV) dos últimos 40 milissegundos do complexo QRS e raiz quadrada média da voltagem ao quadrado dos últimos 40 milissegundos do complexo QRS (RMS40) foram as variáveis avaliadas. Não foram observadas diferenças significativas entre os grupos em relação às variáveis estudadas. Sendo assim, os resultados do presente estudo sugerem que a eletrocardiografia de alta resolução não é uma ferramenta útil no auxílio diagnóstico da cardiomiopatia arritmogênica do ventrículo direito dos cães da raça Boxer que não apresentam alterações miocárdicas evidentes ou disfunção sistólica.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA