Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
4.
J Vasc Surg Cases Innov Tech ; 10(1): 101374, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38130359

RESUMO

Surgical repair of a subclavian artery mycotic aneurysm is dependent on aneurysm-specific characteristics and anatomic exposures could require sternotomy, thoracotomy, or supraclavicular incisions. Alternatively, a median claviculectomy can be used. We successfully performed a subclavian artery to axillary artery bypass with median claviculectomy in a 23-year-old man with multiple comorbidities. Postoperative Doppler ultrasound showed a patent left axillary artery with a palpable left radial artery, and the patient demonstrated full left shoulder range of motion without any significant deformities. This case suggests that a median claviculectomy can produce satisfactory outcomes in patients with subclavian artery mycotic aneurysms.

5.
J Am Heart Assoc ; 12(19): e031118, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37753800

RESUMO

Background The clinical significance of mitral annular calcification (MAC) in patients undergoing mitral transcatheter edge-to-edge repair is not well understood. There is limited evidence regarding the feasibility, durability of repair, and the prognostic value of MAC in this population. We sought to examine the prognostic value of MAC, its severity, and its impact on procedural success and durability of mitral transcatheter edge-to-edge repair. Methods and Results We reviewed the records of 280 patients with moderate-severe or severe mitral regurgitation who underwent mitral transcatheter edge-to-edge repair with MitraClip from March 2014 to March 2022. The primary end point was cumulative survival at 1 year. Independent factors associated with the primary end point were identified using multivariable Cox regression. Among 280 patients included in the final analysis, 249 had none/mild MAC, and 31 had moderate/severe MAC. Median follow-up was 23.1 months (interquartile range: 11.1-40.4). Procedural success was comparable in the MAC and non-MAC groups (92.6% versus 91.4%, P=0.79) with similar rates of residual mitral regurgitation ≤2 at 1 year (86.7% versus 93.2%, P=0.55). Moderate/severe MAC was associated with less improvement in New York Heart Association III/IV at 30 days when compared with none/mild MAC (45.8% versus 14.3%, P=0.001). The moderate/severe MAC group had lower cumulative 1-year survival (56.8% versus 80.0%, hazard ratio [HR], 1.98 [95% CI, 1.27-3.10], P=0.002). Moderate/severe MAC and Society of Thoracic Surgeons predicted risk of mortality for mitral valve repair were independently associated with the primary end point (HR, 2.20 [1.10-4.41], P=0.02; and HR, 1.014 [1.006-1.078], P=0.02, respectively). Conclusions Mitral TEER is a safe and feasible intervention in selected patients with significant MAC and associated with similar mitral regurgitation reduction at 1 year compared with patients with none/mild MAC. Patients with moderate/severe MAC had a high 1-year mortality and less improvement in their symptoms after TEER.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Doenças das Valvas Cardíacas/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Calcinose/complicações , Cateterismo Cardíaco/métodos
6.
J Vasc Surg Venous Lymphat Disord ; 11(5): 978-985.e3, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37030443

RESUMO

BACKGROUND: Driven by the ability to avoid thrombolytics and provide a one stop procedure with immediate hemodynamic improvement, there has been a dramatic increase in the use of mechanical thrombectomy (MT) devices for the treatment of intermediate-to-high risk pulmonary embolism (PE). This study investigated the incidence and outcomes of cardiovascular collapse during MT procedures and demonstrates the role of extracorporeal membrane oxygenation (ECMO) in salvaging patients. METHODS: This single-center retrospective review included patients with PE undergoing MT with the FlowTriever device between 2017 and 2022. Patients presenting periprocedural cardiac arrest were identified and their perioperative characteristics and postoperative outcomes were evaluated. RESULTS: A total of 151 patients with a mean age of 64 ± 14 years who presented with intermediate-to-high risk PE received LBAT procedures during the study period. The simplified PE severity score was ≥1 in 83% of cases and the average RV/LV ratio was 1.6 ± 0.5, with and elevated troponin in 84%. Technical success was achieved in 98.7% and a significant decrease in pulmonary artery systolic pressure (PASP) was observed (37 mm Hg vs 56 mm Hg; P < .0001). Intraoperative cardiac arrest occurred in nine patients (6%). These patients were more likely to present PASP of ≥70 mm Hg (84% vs 14%; P < .001), were more hypotensive upon admission (systolic of 94 ± 14 mm Hg vs 119 ± 23 mm Hg; P = .004), presented lower oxygen saturation levels (87 ± 6% vs 92 ± 6%; P = .023) and were more likely to present with a history of recent surgery (67% vs 18%; P = .004). Four patients were rescued successfully with ECMO and their residual PE was subsequently removed before discharge by surgical embolectomy in two of the four cases and repeat MT in the other two. All five patients (3%) who did not receive ECMO support expired intraoperatively. The overall 30-day mortality was 8% with no death occurring in patients who were salvaged with ECMO. CONCLUSIONS: Large-bore aspiration thrombectomy for acute PE is associated with favorable technical outcomes, but the concern for acute cardiac decompensation is non-negligible in patients presenting with high-risk features and a PASP of ≥70 mm Hg. ECMO can help to salvage some of these patients and should be considered in the treatment algorithms of patients deemed at high risk.


Assuntos
Oxigenação por Membrana Extracorpórea , Parada Cardíaca , Embolia Pulmonar , Humanos , Pessoa de Meia-Idade , Idoso , Oxigenação por Membrana Extracorpórea/métodos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Embolia Pulmonar/complicações , Trombectomia/efeitos adversos , Terapia Trombolítica/efeitos adversos , Doença Aguda , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Estudos Retrospectivos
7.
J Thorac Cardiovasc Surg ; 165(4): 1356-1357, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-34020804
8.
J Endovasc Ther ; 30(4): 550-560, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35587698

RESUMO

BACKGROUND: Operative mortality for type A aortic dissection is still 10-20% at centers of excellence. Additionally, 10-20% are not considered as viable candidates for open surgical repair and not offered life-saving emergency surgery. ARISE is a multicenter investigation evaluating the novel GORE® Ascending Stent Graft (ASG; Flagstaff, AZ). OBJECTIVE: The purpose of this study is to assess early feasibility of using these investigational devices to treat ascending aortic dissection. METHODS: This a prospective, multicenter, non-randomized, single-arm study that enrolls patients at high surgical risk with appropriate anatomical requirements based on computed tomography imaging at 7 of 9 US sites. Devices are delivered transfemorally under fluoroscopic guidance. Primary endpoint is all-cause mortality at 30 days. Secondary endpoints include major adverse cardiovascular and cerebrovascular events (MACCE) at 30 days, 6 months, and 12 months. RESULTS: Nineteen patients were enrolled with a mean age of 75.7 years (range 47-91) and 11 (57.9%) were female. Ten (52.6%) had DeBakey type I disease, and the rest were type II. Sixteen (84.2%) of the patients were acute. Patients were treated with safe access, (7/19 (36.8%) percutaneous, 10/19 (52.6%) transfemoral, 2/19 (10.5%) iliac conduit), delivery, and deployment completed in all cases. Median procedure time was 154 mins (range 52-392) and median contrast used was 111 mL (range 75-200). MACCE at 30 days occurred in 5 patients including mortality 3/19 (15.8%), disabling stroke in 1/19 (5.3%), and myocardial infarction in 1/19 (5.3%). CONCLUSION: Results from the ARISE early feasibility study of a specific ascending stent graft device to treat ascending aortic dissection are promising.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Dissecção da Aorta Ascendente , Procedimentos Endovasculares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Prótese Vascular , Estudos Prospectivos , Resultado do Tratamento , Desenho de Prótese , Stents , Complicações Pós-Operatórias/etiologia , Aneurisma da Aorta Torácica/cirurgia
9.
J Vasc Surg Cases Innov Tech ; 8(3): 425-428, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35996732

RESUMO

We describe a 78-year-old woman with a large ascending aortic pseudoaneurysm who underwent thoracic endovascular aortic repair under intraoperative image fusion guidance and real-time transcranial Doppler (TCD) monitoring. TCD monitoring revealed a total of 419 microembolic signals throughout the procedure, with the majority occurring as the first stent graft crossed the ascending aorta. Two days later, she underwent endovascular repair of a graft type IA endoleak. We highlight the role of image fusion guidance and TCD monitoring in enabling successful thoracic endovascular aortic repair in an elderly woman and in identifying procedural areas of improvement to minimize stroke risk.

10.
Ann Cardiothorac Surg ; 11(1): 16-25, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35211381

RESUMO

Aortic arch aneurysms are a challenging clinical problem especially in high-risk patients. Open aortic arch replacement, even in the best of centers, carries significant risk of stroke or death in this high-risk population. Many high-risk patients are deemed inoperable and not offered repair. Branched and fenestrated thoracic endografts are currently undergoing clinical trials in the United States but are not yet commercially available. Many elderly and frail patients have significant brachiocephalic occlusive disease or anatomy excluding them for consideration for such clinical trials. These patients also present with acute aortic syndromes requiring urgent or emergent repair and are unable to participate in clinical trials due to the time required to have such devices available. Alternative endovascular therapies, including parallel stent grafts (including Chimneys, Snorkels and Periscopes) and physician modified thoracic endografts, have been used to treat such high-risk patients combined with commercially available thoracic endovascular aneurysm repair (TEVAR) devices. This paper aims to review the techniques and current reported outcomes from parallel stent grafts and physician modified devices used to treat high risk patients undergoing repair for aortic arch pathologies.

13.
Ann Thorac Surg ; 113(5): 1685-1691, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34971593

RESUMO

PURPOSE: Better time-resolved imaging of stent grafts in the ascending aorta and arch accounting for cardiac motion is necessary to understand device-related complications and endoleaks. This report describes dynamic time-resolved computed tomographic angiography (d-CTA) and its combination with electrocardiography gating (d-gated CTA) to image stent grafts in the ascending aorta and to characterize endoleaks more clearly. DESCRIPTION: d-CTA involves multiple scans acquired at different time points along the contrast enhancement curve. d-Gated CTA involves concomitant electrocardiography gating in a predefined cardiac phase minimizing motion-induced artifacts. EVALUATION: This report illustrates the utility of d-CTA and d-gated CTA in 2 clinical cases. d-CTA demonstrated a type 1A endoleak in a patient with an aortic arch aneurysm treated with total arch debranching and a thoracic stent graft. d-gated CTA demonstrated a type 1A endoleak in a patient with an ascending aortic pseudoaneurysm treated with aortic cuff placement. CONCLUSIONS: Dynamic, cardiac-gated CTA enables time-resolved angiographic imaging of the ascending aorta and arch without any cardiac motion-related artifacts. Such advanced imaging techniques help with better characterization of endoleaks after stent graft deployment in the ascending aorta and arch.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta/cirurgia , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Stents/efeitos adversos
14.
Ann Thorac Surg ; 114(6): 2260-2261, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34922911
18.
Ann Thorac Surg ; 109(6): 1864, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31678473
20.
Thorac Surg Clin ; 28(1): 43-52, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29150036

RESUMO

Vascular rings and slings may represent life-threatening compression of the esophagus and trachea. Such anatomic variants, although rare, are encountered by all thoracic surgeons in the scope of their practice at some time. The thoracic surgeon, whether treating such patients in the practice of congenital heart surgery, or in the practice of adult cardiac or thoracic surgery must have a requisite understanding of such anatomic variants, their diagnostic workup and radiologic interpretation, as well as their surgical management. Primary tracheobronchial disorders are also frequently encountered in the scope of a thoracic surgical practice and also are discussed.


Assuntos
Broncopatias/cirurgia , Doenças do Esôfago/cirurgia , Cardiopatias Congênitas/cirurgia , Doenças da Traqueia/cirurgia , Anel Vascular/cirurgia , Adolescente , Broncopatias/etiologia , Criança , Doenças do Esôfago/etiologia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Humanos , Doenças da Traqueia/etiologia , Anel Vascular/complicações , Anel Vascular/diagnóstico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA