Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Int J Cardiol Heart Vasc ; 40: 101008, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35330979

RESUMO

Background: Though the co-prevalence of aortic stenosis (AS) and cardiac amyloidosis (CA) is increasingly recognized, the role of transcatheter aortic valve replacement (TAVR) in patients with CA remains unclear. Methods: The National Readmission Dataset (2016-18) and ICD-10 codes were used to identify those with CA and AS, in conjunction with TAVR status. The primary outcome was a composite of heart failure (HF) readmissions and all-cause mortality. All outcomes were followed up to 1-year with a median follow up time 172-days. Kaplan-Meier curves and multivariate cox-proportional hazard regression were used for time-to-event analysis. Results: Of 1,127 CA patients, 92 (8.2%) had undergone TAVR. Patients with CA who received TAVR were younger and more commonly had coronary artery disease (67.3% vs 44.2%). Teaching (93.6% vs 81.1%) and large hospitals (77.7% vs 59.3%) performed more TAVRs. In multivariate analysis, TAVR was associated with an improved primary outcome (8.9% vs 24.4%, HR:0.32; 95% CI 0.14-0.71, p = 0.007) and with reduced HF readmissions (3.8% vs 19.4%, HR:0.22; 95% CI 0.07-0.68, p = 0.008). All-cause mortality was numerically lower in TAVR patients with CA but did not reach statistical significance. Conclusions: CA patients who receive TAVR are younger, and the procedure is more commonly performed at large, teaching hospitals. TAVR was associated with a lower primary composite outcome of HF readmissions and all-cause mortality.

2.
Catheter Cardiovasc Interv ; 98(1): E153-E162, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33166062

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) can be an effective option for high-risk Aortic Regurgitation (AR) patients. Although international experiences of TAVR for AR are published, U.S. data are limited. This study sought to report the short-term outcomes of TAVR in AR in the U.S. METHODS: Study cohorts were derived from the Nationwide Inpatient Sample (NIS) and Nationwide Readmissions Database (NRD) 2016-17. TAVR and AR were identified using ICD-10-CM-codes. The key outcomes were all-cause mortality, disabling stroke, valvular complications, complete heart block (CHB)/permanent pacemaker placement (PPM), open-heart surgery, acute kidney injury (AKI) requiring dialysis, and vascular complications. Multivariate logistic regression was used to adjust for confounders. RESULTS: 915 patients from the NIS (male-71%, age ≥65-84.2%) and 822 patients from the NRD (male-69.3%, age ≥65-80.5%) underwent TAVR for AR. The median length of stay (LOS) was 4 days for both cohorts. In-hospital mortality was 2.7%, and 30-day mortality was 3.3%. Disabling strokes were noted in 0.6% peri-procedurally and 1.8% at 30-days. Valve-related complications were 18-19% with paravalvular leak (4-7%) being the most common. Approximately 11% of patients developed CHB and/or needed PPM in both cohorts. In NRD, 2.2% of patients required dialysis for AKI, 1.5% developed vascular complications, and 0.6% required open-heart surgery within 30-days post-procedure. Anemia was predictive of increased overall complications and valvular complications, whereas peripheral vascular disease was a predictor of increased valvular complications and CHB/PPM. CONCLUSION: TAVR is a promising option in AR. Further studies are necessary for the expansion of TAVR as the standard treatment in AR.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Am J Cardiol ; 125(9): 1355-1360, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32171440

RESUMO

In the era of emerging options for mitral valvular intervention, we sought to characterize the relative utilization, outcomes, and posthospital dispositions of patients referred for transcatheter mitral valve repair (TMVRepair) and surgical mitral valve procedures (SMVP), by cancer-status. Leveraging the National Inpatient Sample, a representative national dataset, ICD-9 codes for all adults >18 years with co-morbid mitral regurgitation, and cancer without metastatic disease admitted from 2003 to 2015 were queried. TMVRepair was performed in 700 hospitalizations from 2012 to 2015, whereas SMVP was utilized during 12,863 hospitalizations from 2003 to 2015. During follow-up, we observed a proportional increase in TMVRepair utilization among cancer patients (vs noncancer), particularly in 2015 (14.2% vs 8.2%, p <0.0001). There was no difference in in-hospital mortality (1.4% vs 1.8%, p = 0.71), ischemic stroke (0.7% vs 0.6%, p = 0.97), major bleeding (8.6% vs 10.9%, p = 0.36), and home discharge (62.1% vs 65.7%, p = 0.45) by cancer-status among patients who underwent TMVRepair; but, cost of care was increased ($52,325 vs $48,832, p <0.0001). Similarly, there was no difference in in-hospital mortality (3.1% vs 3.4%, p = 0.36), ischemic stroke (2.6% vs 3.1%, p = 0.16) as well as the cost-of-care ($58,106 vs $58,844, p = 0.49) among those who underwent SMVP across the same period; but, cancer was associated with increased major bleeding (34.9% vs 30.5%, p <0.0001), and lower likelihood of home discharge (32.8% vs 38.6%, p <0.0001). In conclusion, TMVRepair and SMVP were associated with comparable in-hospital mortality and outcomes in cancer versus noncancer patients. However, cancer patients treated with SMVP experienced more frequent bleeding related complications compared with noncancer patients.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Insuficiência da Valva Mitral/complicações , Valva Mitral/cirurgia , Neoplasias/complicações , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/tendências , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
4.
Cardiovasc Revasc Med ; 21(11S): 28-32, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-30975579

RESUMO

We describe an interesting case of a 71 years old fragile female, with progressive shortness of breath on exertion and ankle swelling, cardiac failure NYHA class III. She also had chest irradiation due to Hodgkin's disease many years before, previous surgical aortic valve replacement using bioprosthetic stent-less Freestyle #25 mm valve (Medtronic, Inc) in 2000 for severe aortic stenosis, history of cardiac arrest in 2012 and angioplasty to ostial RCA, PCI to ostial RCA in 2014, CABG (RA graft to RCA) in 2014 (RCA intra-stent restenosis with refractory ischemia), anemia requiring regular transfusions, bronchiectasis and chronic kidney disease. Because of the great comorbidities, STS 4.9% and worsening of the symptoms due to severe aortic valve regurgitation, heart team decided to perform "valve-in-valve" Transcatheter Aortic Valve Replacement (VIV-TAVR), but we already predicted coronary occlusion while performing this procedure because of the low left main coronary ostium and short aortic valve sinus. So regarding the probable left main coronary occlusion during the valve implantation, we decided to perform the placement of a not deployed stent inside the left main prior to the valve procedure, and to deploy it in case the predicted left main occlusion occurred. So just after the VIV-TAVR procedure, we observed left main coronary occlusion and the patient got ischemic cardiogenic shock and cardiac arrest, so we performed immediate PCI and deployed the bailout stent. After some minutes of chest compressions, an Impella mechanical circulatory support system (Abiomed, Danvers, MA) had to be installed. Patient recovered spontaneous circulation, and after hemodynamic stabilization, she was sent to the Intensive Coronary Unit, without further complications. She was discharged successfully without neurological or cardiac sequelae after 1 week.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Resultado do Tratamento
5.
J Invasive Cardiol ; 31(3): 15-20, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30555054

RESUMO

OBJECTIVES: To investigate the effect of TAVR technique on in-hospital and 30-day outcomes in patients with aortic stenosis (AS) and reduced ejection fraction (EF). BACKGROUND: Patients with AS and concomitant low EF may be at risk for adverse hemodynamic effects from general anesthesia utilized in transcatheter aortic valve replacement (TAVR) via the conventional strategy (CS). These patients may be better suited for the minimally invasive strategy (MIS), which employs conscious sedation. However, data are lacking that compare MIS to CS in patients with AS and concomitant low EF. METHODS: In this retrospective study, we identified all patients with low EF (<50%) undergoing transfemoral MIS-TAVR vs CS-TAVR between March 2011 and May 2018. Our primary endpoint was defined as the composite of in-hospital mortality and major periprocedural bleeding or vascular complications. RESULTS: Two hundred and seventy patients had EF <50%, while 154 patients had EF ≤35%. Overall, a total of 236 patients were in the MIS group and 34 were in the CS group. Baseline characteristics between the two groups were similar except for Society of Thoracic Surgeons (STS) score (MIS 8.4 ± 5.1 vs CS 11.7 ± 6.8; P<.01). There were no differences between the two groups in incidence of the primary endpoint (MIS 5.5% vs CS 8.8%; odds ratio for MIS, 0.60; 95% confidence interval, 0.16-2.23; P=.45). CONCLUSIONS: In patients with severe AS and reduced EF, MIS was not associated with adverse in-hospital or 30-day clinical outcomes compared with CS. In these patients, MIS may be a suitable alternative to CS without compromising clinical outcomes.


Assuntos
Estenose da Valva Aórtica/terapia , Ecocardiografia Transesofagiana/métodos , Insuficiência Cardíaca/terapia , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Cateterismo Cardíaco/métodos , Baixo Débito Cardíaco/diagnóstico por imagem , Estudos de Coortes , Sedação Consciente/métodos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Humanos , Tempo de Internação , Modelos Logísticos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Análise Multivariada , Prognóstico , Valores de Referência , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Cirurgia Assistida por Computador/métodos , Taxa de Sobrevida , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
Am J Cardiol ; 123(3): 419-425, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30527797

RESUMO

Transfemoral transcatheter aortic valve replacement (TF-TAVR) is mostly performed under general anesthesia (GA) in most US centers. We examined in-hospital and 30-day outcomes in patients who underwent TF-TAVR with a self-expanding bioprosthesis using local anesthesia (LA) or GA. Patients from the Transcatheter Valve Therapeutics Registry who underwent TF-TAVR from January 2014 to June 2016 with LA or GA were evaluated. Propensity matching was performed and procedural and clinical outcomes compared up to 30 days. A total of 11,006 patients were included (GA: 8,239 [74.9%] and LA: 2,767 [25.1%]). After propensity matching (n = 1,988 matched sets), device success was similar (94.5% vs 94.6%, p = 0.905). No differences in in-hospital stroke (2.7% vs 2.3%, p = 0.413) or paravalvular regurgitation grade (p = 0.113) were noted. Fewer LA patients were converted to open heart surgery (0.2% vs 0.6%, p = 0.076) or experienced an in-hospital major vascular complication (0.7% vs 1.4%, p = 0.026). Intensive care unit time (40.1 ± 58.4 vs 50.9 ± 72.1 hours, p < 0.001) and postprocedure length of stay (4.1 ± 3.6 vs 5.0 ± 4.5 days, p < 0.001) were significantly shorter with LA. In-hospital and 30-day all-cause mortality were lower in the LA cohort compared to the GA cohort ([1.1% vs 2.7%, p < 0.001] and [2.1% vs 3.9%, p = 0.001]). In conclusion, in the largest series of self-expanding bioprostheses for TF-TAVR, these propensity-matched cohorts demonstrate that LA is an acceptable alternative to GA with comparable success, lower safety outcomes, complications rates, and in-hospital and 30-day all-cause mortality.


Assuntos
Anestesia Geral , Anestesia Local , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Bioprótese , Estudos de Coortes , Feminino , Próteses Valvulares Cardíacas , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Complicações Intraoperatórias , Tempo de Internação/estatística & dados numéricos , Masculino , Complicações Pós-Operatórias , Sistema de Registros , Substituição da Valva Aórtica Transcateter/mortalidade
7.
Catheter Cardiovasc Interv ; 92(4): 757-765, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29171682

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement (SAVR) for patients with severe symptomatic aortic stenosis (AS) who are at intermediate and high risk for surgery. Commercial use of TAVR has expanded to patients with end stage renal disease (ESRD). OBJECTIVES: Compare in-hospital outcomes of TAVR versus SAVR in ESRD patients requiring hemodialysis (HD). METHODS: ESRD patients on HD undergoing TAVR (n = 328) or SAVR (n = 697) between 2012 and 2014 were identified in the National Inpatient Sample (NIS). Propensity-score matching method was used to minimize selection bias. Baseline characteristics and in-hospital outcomes were compared. RESULTS: TAVR patients were older (75.3 vs. 61.6 years, P < 0.001) and had more comorbidities, including congestive heart failure (16.2% vs. 7.5%), diabetes mellitus (28.4% vs. 22.5%), chronic lung disease (27.7% vs. 20.4%), and peripheral vascular disease (35.1% vs. 21.2%). Propensity-score matching yielded 175 pairs of patients matched on 30 baseline covariates. Overall in-hospital mortality was high (9.9%) and similar between TAVR and SAVR (8% vs. 10.3%, P = 0.58). TAVR was associated with shorter length of stay (LOS) (8 vs. 14 days, P < 0.001), lower hospitalization cost ($276,448 vs. $364,280, P = 0.01), lower in-hospital complications (60.6% vs. 76%, P = 0.003), and higher rate of home discharge (31.4% vs. 17.7%, P = 0.004) compared with SAVR. CONCLUSIONS: Regardless of treatment modality, patients with AS on HD have high in-hospital mortality. TAVR and SAVR have comparable in-hospital mortality in this population. However, TAVR is associated with shorter LOS, lower hospitalization costs, lower in-hospital complications, and higher rates of home discharge.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Falência Renal Crônica/terapia , Diálise Renal , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/economia , Estenose da Valva Aórtica/mortalidade , Análise Custo-Benefício , Bases de Dados Factuais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/economia , Implante de Prótese de Valva Cardíaca/mortalidade , Custos Hospitalares , Mortalidade Hospitalar , Humanos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/economia , Falência Renal Crônica/mortalidade , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Alta do Paciente , Complicações Pós-Operatórias/mortalidade , Diálise Renal/efeitos adversos , Diálise Renal/economia , Diálise Renal/mortalidade , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/economia , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
9.
Ann Thorac Surg ; 104(2): e119-e121, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28734430

RESUMO

Prosthetic valve endocarditis is a very grave and often terminal disease. Surgical valve replacement remains the cornerstone treatment for this disease. However, it is often contraindicated. Herein, we describe the implantation under direct visualization of a self-expandable transcatheter heart valve in a prohibitive surgical risk patient with homograft aortic valve endocarditis.


Assuntos
Valva Aórtica/cirurgia , Endocardite Bacteriana/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese/cirurgia , Infecções Estreptocócicas/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Adulto , Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Endocardite Bacteriana/diagnóstico , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Reoperação , Infecções Estreptocócicas/diagnóstico , Tomografia Computadorizada por Raios X , Transplante Homólogo
10.
Catheter Cardiovasc Interv ; 89(4): E104-E111, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27470983

RESUMO

BACKGROUND: The Parachute is a novel percutaneously implanted ventricular partitioning device (VPD) that has emerged as a safe and feasible treatment option for patients with heart failure following anterior wall myocardial infarction. VPD efficacy is likely dependent on optimal device placement, but to date there are no published data examining the effect of device positioning on patient outcomes. METHODS AND RESULTS: We retrospectively identified 32 patients successfully implanted with the Parachute device, all of whom underwent cardiac computed tomography (CCT) at baseline and after 6 months of follow-up. Patients were divided into two groups based on self-reported improvement in New York Heart Association (NYHA) functional class: "not improved NYHA" (n = 12) and "improved NYHA" (n = 20). There were significant differences between both groups with regard to device positioning on follow-up CCT. Compared to patients with "improved NYHA," patients with "not improved NYHA" had longer distances from device foot to left ventricular apex (8.0 ± 4.9 vs. 2.9 ± 4.6 mm; P = 0.01), and higher lateral angles (18.0 ± 14 vs. 9.1 ± 6.8 degrees; P = 0.02), respectively. There was no significant difference between the two groups in landing zone (45.4 ± 7. vs. 45.1 ± 6.9 mm; P = 0.92) and inferior angle (14.0 ± 11.9 vs. 14.3 ± 10.1 degrees; P = 0.95). There was a numerically larger malapposition area in the "not improved NYHA" group (5.1 ± 4.5 vs. 3.2 ± 2.2 cm2; P = 0.12). CONCLUSION: Quality of Parachute implant impacted clinical outcome, these findings should be applied prospectively in helping operators to achieve optimal implant. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Remodelação Ventricular/fisiologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
11.
Int J Cardiol ; 224: 440-446, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27710781

RESUMO

BACKGROUND: Although mitral regurgitation (MR) affects a relevant and increasing number of elderly, an optimal management of this high-risk population is challenging. METHODS AND RESULTS: The aim of this prospective, observational study was to compare one-year outcomes of MitraClip therapy in high surgical risk patients with moderate-to-severe or severe MR between patients aged <75 versus ≥75years. A total of 180 patients were included: 92 were <75years and 88 were ≥75years old. At one-year follow-up the primary efficacy endpoint (composite of death, surgery for mitral valve dysfunction and grade 3+ or 4+ MR) occurred in 41 patients (24.5%), with similar rates between those aged <75years (23.9%) and those ≥75years (25.2%), p=0.912. A total of 21 (12.2%) deaths were observed within 1year after the MitraClip procedure, without significant differences in cumulative mortality rates between elderly and younger patients (10.8% vs. 13.3%, respectively, p=0.574). Compared with baseline, the significant reduction in MR severity achieved after the procedure was sustained at one-year follow-up, in both elderly and younger patients and a significant improvement in NYHA functional class was observed in both groups. A total of 18 (10.0%) patients experienced a re-hospitalization for acute heart failure within one-year after the MitraClip procedure, with no significant differences between elderly and younger. At one-year follow-up both elderly and younger patients showed significant reductions in left ventricular volumes, with changes of similar extent between the two subgroups. CONCLUSIONS: MitraClip therapy can be considered a viable option also among subsets with more advanced age.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Complicações Pós-Operatórias , Risco Ajustado/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Ecocardiografia/métodos , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Índice de Gravidade de Doença
12.
JACC Cardiovasc Interv ; 9(13): 1361-71, 2016 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-27388824

RESUMO

OBJECTIVES: This study sought to evaluate the outcomes of the early experience of transcatheter mitral valve replacement (TMVR) with balloon-expandable valves in patients with severe mitral annular calcification (MAC) and reports the first large series from a multicenter global registry. BACKGROUND: The risk of surgical mitral valve replacement in patients with severe MAC is high. There are isolated reports of successful TMVR with balloon-expandable valves in this patient population. METHODS: We performed a multicenter retrospective review of clinical outcomes of patients with severe MAC undergoing TMVR. RESULTS: From September 2012 to July of 2015, 64 patients in 32 centers underwent TMVR with compassionate use of balloon-expandable valves. Mean age was 73 ± 13 years, 66% were female, and mean Society of Thoracic Surgeons score was 14.4 ± 9.5%. The mean mitral gradient was 11.45 ± 4.4 mm Hg and the mean mitral area was 1.18 ± 0.5 cm(2). SAPIEN valves (Edwards Lifesciences, Irvine, California) were used in 7.8%, SAPIEN XT in 59.4%, SAPIEN 3 in 28.1%, and Inovare (Braile Biomedica, Brazil) in 4.7%. Access was transatrial in 15.6%, transapical in 43.8%, and transseptal in 40.6%. Technical success according to Mitral Valve Academic Research Consortium criteria was achieved in 46 (72%) patients, primarily limited by the need for a second valve in 11 (17.2%). Six (9.3%) had left ventricular tract obstruction with hemodynamic compromise. Mean mitral gradient post-procedure was 4 ± 2.2 mm Hg, paravalvular regurgitation was mild or absent in all. Thirty-day all-cause mortality was 29.7% (cardiovascular = 12.5% and noncardiac = 17.2%); 84% of the survivors with follow-up data available were in New York Heart Association functional class I or II at 30 days (n = 25). CONCLUSIONS: TMVR with balloon-expandable valves in patients with severe MAC is feasible but may be associated with significant adverse events. This strategy might be an alternative for selected high-risk patients with limited treatment options.


Assuntos
Calcinose/cirurgia , Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Valvuloplastia com Balão , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Europa (Continente) , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , América do Norte , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , América do Sul , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
14.
EuroIntervention ; 11(14): e1649-57, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27056125

RESUMO

AIMS: Our aim was to evaluate the impact of baseline chronic kidney disease (CKD) on clinical outcomes after percutaneous edge-to-edge mitral valve repair (PMVR). METHODS AND RESULTS: Two hundred and fourteen consecutive patients dichotomised by the presence of baseline CKD (n=113) or no-CKD (n=101) had their clinical outcomes compared up to 12-month follow-up. The primary safety endpoint was the incidence of major adverse events and the primary efficacy endpoint was freedom from death, surgery for MV dysfunction, or grade ≥3+ MR. The primary safety endpoint was demonstrated in 12.4% vs. 2.0% in CKD and no-CKD patients, respectively (p=0.003). The primary efficacy endpoint at 12 months was significantly lower in CKD patients (65.8% vs. 84.2%, respectively, log-rank p=0.005). While MR reduction and NYHA functional class improvement were mostly sustained and equivalent up to 12 months in no-CKD patients, they were impaired in CKD patients. Baseline CKD was an independent predictor of the primary efficacy endpoint (adjusted HR 2.48, 95% CI: 1.29 to 4.79, p=0.006) and calcified leaflet predicted grade ≥3+ MR at 12 months (adjusted HR 6.56, 95% CI: 2.71 to 15.88, p<0.001). CONCLUSIONS: CKD patients had worse clinical outcomes compared with no-CKD patients post PMVR. CKD was an independent predictor of the primary efficacy endpoint, whereas calcified leaflet was an independent predictor of grade ≥3+ MR at 12 months.


Assuntos
Insuficiência da Valva Mitral/cirurgia , Insuficiência Renal Crônica/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Sistema de Registros , Insuficiência Renal Crônica/cirurgia , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
15.
Am J Cardiol ; 116(11): 1731-6, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26433275

RESUMO

Some centers, mostly in Europe, have demonstrated the feasibility of a minimally invasive strategy (MIS; i.e., local anesthesia and conscious sedation, performed in the cath laboratory without transesophageal echocardiography guidance). Nonetheless, the experience of MIS for TAVI using both commercially available valves is lacking in the United States. We, therefore, retrospectively studied all transfemoral TAVI cases performed at our institution between March 2011 and November 2014 to assess the safety and efficacy of MIS. Patients were dichotomized according to the strategy (MIS vs conventional strategy [CS]) used for the procedure. One hundred sixteen patients were included in the MIS group and 91 patients were included in the CS group. Baseline characteristics were similar, and procedural success was comparable (99.1% in MIS and 98.9% in CS, p = 1). One intraprocedural death occurred in each group, whereas conversion rates to general anesthesia were low (3.4%). Comparable device success was obtained. Rates of complications and >mild paravalvular leak before discharge were low and comparable. Length of hospital stay was significantly reduced in the MIS (median, 3.0 [2.0 to 5.0] days) compared with than that in CS group (median 6.0 days [3.5, 8.0]). At a median follow-up of 230 days, no significant difference in survival rate was detected (89% vs 88%, p = 0.9). On average, MIS was associated with remarkable cost saving compared with CS ($16,000/case). In conclusion, TAVI through MIS was associated with a shorter postprocedural hospital stay, lower costs, and similar safety profile while keeping procedural efficacy compared with CS.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Local , Estenose da Valva Aórtica/mortalidade , Sedação Consciente , Redução de Custos , Ecocardiografia Transesofagiana , Feminino , Implante de Prótese de Valva Cardíaca , Mortalidade Hospitalar , Humanos , Tempo de Internação , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/economia , Resultado do Tratamento
16.
Am J Cardiol ; 116(4): 604-11, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26081069

RESUMO

Although transcatheter aortic valve implantation (TAVI) is still currently guided by transesophageal echocardiography (TEE) in a considerable number of hospitals, exclusive angiographic (Angio) guidance seems a reasonable approach in this setting. To date, however, no studies have directly compared the outcomes of TAVI according to the imaging modality used for procedural guidance. We, therefore, used data from a large multicenter data repository to compare the outcomes of TAVI guided exclusively by Angio and ATEE. All consecutive patients with severe aortic stenosis who underwent TAVI with the CoreValve Revalving System (CRS) in 9 Italian centers from September 2007 to March 2014, dichotomized according to the imaging support used to guide the procedure (ATEE and Angio), were included. Thirty-day and 12-month clinical outcomes were evaluated. Propensity matching analysis was performed to adjust for baseline differences. A total of 625 patients were included (256 and 369 patients were included in the ATEE and Angio groups, respectively). Patients from the ATEE more frequently underwent TAVI under general anesthesia compared with Angio group (37.9% vs 22.8%, respectively, p <0.001). Importantly, ∼80% of the patients experienced mild or even less aortic regurgitation as assessed by angiography after the procedure, without between-group differences. Postdilation and valve-in-valve rates were equivalent (24.7% vs 25%, p = 0.934 and 5.5% vs 3.4%, respectively, p = 0.217). No differences were revealed in the rates of death, cardiovascular death, and stroke or transient ischemic attack at 12-month follow-up. These results were sustained after propensity matching analysis. In conclusion, as long as a comprehensive procedural planning is performed, TAVI with CRS may be performed exclusively under angiographic guidance without the need for associated TEE.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária , Ecocardiografia Transesofagiana , Cirurgia Assistida por Computador , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Bases de Dados Factuais , Feminino , Seguimentos , Humanos , Masculino , Fatores de Tempo , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 85(5): 889-97, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25367550

RESUMO

OBJECTIVES: To assess the influence of patients' gender on the outcomes of percutaneous edge-to-edge mitral valve repair (PMVR) using the MitraClip system. BACKGROUND: Although gender-related differences have been extensively documented in patients who undergo surgery for moderate-to-severe (3+) and severe (4+) mitral regurgitation (MR), studies assessing whether these differences exist after PMVR are lacking. METHODS: Clinical and echocardiographic data through 12-month follow up from 171 consecutive patients whom underwent MitraClip implantation and were dichotomized by the gender (106 males and 65 females) were obtained. The primary safety endpoint was the incidence of major adverse events at 30 days and the primary efficacy endpoint was freedom from death, surgery for mitral valve dysfunction, or grade≥3+ MR at 12-month follow up. RESULTS: The primary safety endpoint was observed in four males (3.8%) and four females (6.2%) (P=0.358). Remarkable reduction in MR postprocedure was revealed in both groups, and these results were mostly sustained. Furthermore, left ventricle reverse remodeling and New York Heart Association (NYHA) functional class improvement were revealed in both groups, but females tended to demonstrate worse results over time (P=0.083). The primary efficacy endpoint obtained by Kaplan-Meier estimates was observed in 76.3 and 70.2%, respectively (log rank P=0.231). CONCLUSIONS: MitraClip implantation in patients with 3+ and 4+ MR is safe and efficacious until mid-term follow up, regardless of patients' gender. Despite improvement in NYHA functional class in both groups, female gender demonstrated a trend toward poorer results. Further validation of our findings is warranted.


Assuntos
Ecocardiografia , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Idoso , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Desenho de Prótese , Fatores Sexuais , Fatores de Tempo
19.
JACC Cardiovasc Interv ; 8(1 Pt A): 74-82, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25499300

RESUMO

OBJECTIVES: This study sought to compare, in high-risk patients with 3+ to 4+ mitral regurgitation (MR) dichotomized by baseline echocardiographic features, acute, 30-day, and 12-month outcomes following percutaneous mitral valve repair using the MitraClip. BACKGROUND: The feasibility and mid-term outcomes after MitraClip implantation in patients with echocardiographic features different from the EVEREST (Endovascular Valve Edge-to-Edge Repair) I and II trials have been scarcely studied. METHODS: Clinical and echocardiographic outcomes through 12-month follow-up of consecutive patients who underwent MitraClip implantation were obtained from an ongoing prospective registry. Two different groups, divided according to baseline echocardiographic criteria (investigational group [EVERESTOFF] and control group [EVERESTON]), were compared. RESULTS: Seventy-eight patients were included in EVERESTOFF and 93 patients in EVERESTON groups. Important and comparable acute reductions in MR and no clip-related complications were revealed. The primary safety endpoint at 30 days was comparable between groups (2.6% vs. 6.5%, respectively, p = 0.204); in addition, MR reduction was mostly sustained, whereas equivalent improvement in New York Heart Association functional class were demonstrated. Kaplan-Meier freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR at 12 months was demonstrated in 71.4% and 76.2%, respectively, in the EVERESTOFF and EVERESTON groups (log rank p = 0.378). Significant improvements in ejection fraction and reduction in left ventricle volumes were demonstrated in both groups over time, but the baseline between-group differences were sustained. CONCLUSIONS: MitraClip implantation in patients with expanded baseline echocardiographic features, compared with the control group, was associated with similar rates of safety and efficacy through 12-month follow-up. Further validation of our findings is warranted.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Função Ventricular Esquerda
20.
EuroIntervention ; 10(12): 1383-90, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24801119

RESUMO

AIMS: To compare the efficacy and safety of the MiStent absorbable polymer sirolimus-eluting stent (APSES) with a zotarolimus-eluting stent (ZES). METHODS AND RESULTS: The trial was a 2:1 randomisation at 26 sites of 184 patients implanted with an APSES (n=123) versus a ZES (n=61). Following stent implantation, all patients underwent quantitative coronary angiography at baseline and at nine months of follow-up, while a select subgroup also underwent optical coherence tomography (OCT). The primary efficacy hypothesis was superiority of in-stent late lumen loss (LLL) of APSES compared to ZES. At nine months, the primary endpoint was met, with a mean in-stent LLL of 0.27±0.46 mm in 103 APSES patients versus 0.58±0.41 mm in 52 ZES patients (p<0.001). The proportion of uncovered stent struts by OCT at nine months was very low in both groups. The mean neointimal thickness of covered struts (p=0.002) and percent net volume obstruction (p≤0.003) were significantly lower in the APSES than in the ZES group. Major adverse cardiac event and stent thrombosis rates were low and comparable between groups. CONCLUSIONS: The DESSOLVE II trial demonstrated superiority in the primary efficacy endpoint of nine-month mean LLL for APSES compared to ZES. Strut coverage by OCT was high with both stents and the clinical safety endpoints including stent thrombosis were equally low in both groups. ClinicalTrials.gov Identifier: NCT01294748.


Assuntos
Implantes Absorvíveis , Antibióticos Antineoplásicos/uso terapêutico , Reestenose Coronária/patologia , Estenose Coronária/terapia , Stents Farmacológicos , Neointima/patologia , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/diagnóstico por imagem , Polímeros , Método Simples-Cego , Tomografia de Coerência Óptica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA