1.
Resuscitation ; 163: 162-171, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33819501

RESUMO

AIM: To assess if, in comatose resuscitated patients, the amplitude of the N20 wave (N20amp) of somatosensory evoked potentials (SSEP) can predict 6-months neurological outcome. SETTING: Multicentre study in 13 Italian intensive care units. METHODS: The N20amp in microvolts (µV) was measured at 12 h, 24 h, and 72 h from cardiac arrest, along with pupillary reflex (PLR) and a 30-min EEG classified according to the ACNS terminology. Sensitivity and false positive rate (FPR) of N20amp alone or in combination were calculated. RESULTS: 403 patients (age 69[58-68] years) were included. At 12 h, an N20amp >3 µV predicted good neurological outcome (Cerebral Performance Categories [CPC] 1-2) with 61[50-72]% sensitivity and 11[6-18]% FPR. Combining it with a benign (continuous or nearly continuous) EEG increased sensitivity to 91[82-96]%. For poor outcome (CPC 3-5), an N20Amp ≤0.38 µV, ≤0.73 µV and ≤1.01 µV at 12 h, 24 h, and 72 h, respectively, had 0% FPR with sensitivity ranging from 61[51-69]% and 82[76-88]%. Sensitivity was higher than that of a bilaterally absent N20 at all time points. At 12 h and 24 h, a highly malignant (suppression or burst-suppression) EEG and bilaterally absent PLR achieved 0% FPR only when combined with SSEP. A combination of all three predictors yielded a 0[0-4]% FPR, with maximum sensitivity of 44[36-53]%. CONCLUSION: At 12 h from arrest, a high N20Amp predicts good outcome with high sensitivity, especially when combined with benign EEG. At 12 h and 24 h from arrest a low-voltage N20amp has a high sensitivity and is more specific than EEG or PLR for predicting poor outcome.


Assuntos
Parada Cardíaca , Hipotermia Induzida , Idoso , Coma/diagnóstico , Coma/etiologia , Coma/terapia , Eletroencefalografia , Potenciais Somatossensoriais Evocados , Parada Cardíaca/terapia , Humanos , Pessoa de Meia-Idade , Prognóstico
2.
Resuscitation ; 160: 158-167, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33338571

RESUMO

BACKGROUND: Bilaterally absent pupillary light reflexes (PLR) or N20 waves of short-latency evoked potentials (SSEPs) are recommended by the 2015 ERC-ESICM guidelines as robust, first-line predictors of poor neurological outcome after cardiac arrest. However, recent evidence shows that the false positive rates (FPRs) of these tests may be higher than previously reported. We investigated if testing accuracy is improved when combining PLR/SSEPs with malignant electroencephalogram (EEG), oedema on brain computed tomography (CT), or early status myoclonus (SM). METHODS: Post-hoc analysis of ProNeCA multicentre prognostication study. We compared the prognostic accuracy of the ERC-ESICM prognostication strategy vs. that of a new strategy combining ≥2 abnormal results from any of PLR, SSEPs, EEG, CT and SM. We also investigated if using alternative classifications for abnormal SSEPs (absent-pathological vs. bilaterally-absent N20) or malignant EEG (ACNS-defined suppression or burst-suppression vs. unreactive burst-suppression or status epilepticus) improved test sensitivity. RESULTS: We assessed 210 adult comatose resuscitated patients of whom 164 (78%) had poor neurological outcome (CPC 3-5) at six months. FPRs and sensitivities of the ≥2 abnormal test strategy vs. the ERC-ESICM algorithm were 0[0-8]% vs. 7 [1-18]% and 49[41-57]% vs. 63[56-71]%, respectively (p < .0001). Using alternative SSEP/EEG definitions increased the number of patients with ≥2 concordant test results and the sensitivity of both strategies (67[59-74]% and 54[46-61]% respectively), with no loss of specificity. CONCLUSIONS: In comatose resuscitated patients, a prognostication strategy combining ≥2 among PLR, SSEPs, EEG, CT and SM was more specific than the 2015 ERC-ESICM prognostication algorithm for predicting 6-month poor neurological outcome.


Assuntos
Parada Cardíaca , Hipotermia Induzida , Adulto , Algoritmos , Coma/diagnóstico , Coma/etiologia , Coma/terapia , Eletroencefalografia , Parada Cardíaca/diagnóstico , Parada Cardíaca/terapia , Humanos , Prognóstico
3.
Can J Neurol Sci ; 29(2): 180-3, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12035842

RESUMO

BACKGROUND: Ifosfamide (IFX), an alkylating agent and isomer of cyclophosphamide, is used as a single agent or a component of multi-agent chemotherapy in the treatment of ovarian, testicular, head and neck cancers, sarcomas and lymphomas. Encephalopathy is manifested by cerebellar ataxia, confusional state, complex visual hallucinations, extrapyramidal signs, seizures, and mutism. CASE REPORTS: We report two patients with non-Hodgkin's lymphoma presenting with mutism and confusional state after IFX infusion. Nonconvulsive status epilepticus (NCSE) as the cause of confusion was diagnosed on the basis of EEG pattern and the apparent improvement following intravenous administration of diazepam. CONCLUSIONS: Electroencephalogram abnormalities during IFX treatment have been described but recordings are only available in six cases. In three of them, paroxysmal alterations warranted the diagnosis of NCSE; however, most cases of IFX encephalopathy might have associated NCSE.


Assuntos
Antineoplásicos Alquilantes/efeitos adversos , Epilepsia Generalizada/induzido quimicamente , Ifosfamida/efeitos adversos , Síndromes Neurotóxicas/etiologia , Síndromes Neurotóxicas/fisiopatologia , Adulto , Anticonvulsivantes/uso terapêutico , Antineoplásicos Alquilantes/uso terapêutico , Diazepam/uso terapêutico , Eletroencefalografia/efeitos dos fármacos , Epilepsia Generalizada/tratamento farmacológico , Epilepsia Generalizada/fisiopatologia , Feminino , Humanos , Ifosfamida/uso terapêutico , Linfoma não Hodgkin/tratamento farmacológico , Pessoa de Meia-Idade , Síndromes Neurotóxicas/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA