Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Commun Med (Lond) ; 3(1): 164, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37945817

RESUMO

BACKGROUND: Multiparametric magnetic resonance imaging (mpMRI) and positron emission tomography (PET) are widely used for the management of prostate cancer (PCa). However, how these modalities complement each other in PCa risk stratification is still largely unknown. We aim to provide insights into the potential of mpMRI and PET for PCa risk stratification. METHODS: We analyzed data from 55 consecutive patients with elevated prostate-specific antigen and biopsy-proven PCa enrolled in a prospective study between December 2016 and December 2019. [68Ga]PSMA-11 PET (PSMA-PET), [11C]Acetate PET (Acetate-PET) and mpMRI were co-registered with whole-mount histopathology. Lower- and higher-grade lesions were defined by International Society of Urological Pathology (ISUP) grade groups (IGG). We used PET and mpMRI data to differentiate between grades in two cases: IGG 3 vs. IGG 2 (case 1) and IGG ≥ 3 vs. IGG ≤ 2 (case 2). The performance was evaluated by receiver operating characteristic (ROC) analysis. RESULTS: We find that the maximum standardized uptake value (SUVmax) for PSMA-PET achieves the highest area under the ROC curve (AUC), with AUCs of 0.72 (case 1) and 0.79 (case 2). Combining the volume transfer constant, apparent diffusion coefficient and T2-weighted images (each normalized to non-malignant prostatic tissue) results in AUCs of 0.70 (case 1) and 0.70 (case 2). Adding PSMA-SUVmax increases the AUCs by 0.09 (p < 0.01) and 0.12 (p < 0.01), respectively. CONCLUSIONS: By co-registering whole-mount histopathology and in-vivo imaging we show that mpMRI and PET can distinguish between lower- and higher-grade prostate cancer, using partially discriminative cut-off values.


Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) are two medical imaging methods commonly used to image prostate cancers. However, the relationship between images obtained with these methods and prostate cancer aggressiveness is not well understood. Here, we investigate whether MRI and PET can differentiate between lower- and higher-grade prostate tumors, where grade is an indicator of how aggressive the disease is likely to be. We find that the characteristics of prostate cancer tumors as seen on MRI and PET scans can help to predict tumor grade. This means that these imaging methods may be helpful when clinicians are predicting patient prognosis and deciding on appropriate treatments. However, further validation is necessary before these approaches are widely implemented for this purpose.

2.
Int J Colorectal Dis ; 38(1): 239, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37755537

RESUMO

PURPOSE: Sarcopenia and myosteatosis, quantified via computed tomography (CT), are associated with poor colorectal cancer outcomes. These body composition estimates can be influenced by physical exercise. We explored the correlation between pre-diagnostic physical exercise, body composition close to diagnosis, and the combined prognosis impact of these factors. METHODS: We studied 519 stage I-III colorectal cancer (CRC) cases diagnosed 2000-2016 with pre-diagnostic self-reported recreational physical exercise data collected in the prospective, population-based Northern Sweden Health and Disease Study, and CT-estimated skeletal muscle index (SMI) or skeletal muscle density (SMD). Risk estimates were calculated by multivariable logistic regression and Cox proportional hazards models. RESULTS: No association was seen between low pre-diagnostic physical exercise and sarcopenia/myosteatosis in the multivariable model adjusted for age, sex, educational level, tumor stage, and tumor location. In multivariable Cox regression models, the combination of low pre-diagnostic physical exercise and either sarcopenia or myosteatosis at the time of diagnosis was associated with cancer-specific mortality compared to the reference group of high physical exercise combined with no sarcopenia/myosteatosis (adjusted HR 1.94 95% CI 1.00-3.76 for sarcopenia and adjusted HR 2.39 95% CI 1.16-4.94 for myosteatosis). CONCLUSIONS: The combined presence of low pre-diagnostic physical exercise and sarcopenia or myosteatosis was associated with increased CRC-specific mortality. Despite the positive effect on prognosis, physical exercise did not alter body composition estimates at diagnosis, which could indicate attenuation from other factors.


Assuntos
Neoplasias Colorretais , Sarcopenia , Humanos , Sarcopenia/diagnóstico , Estudos Prospectivos , Composição Corporal , Neoplasias Colorretais/diagnóstico , Exercício Físico
3.
Nucl Med Commun ; 44(11): 997-1004, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37615497

RESUMO

OBJECTIVE: PET/CT and multiparametric MRI (mpMRI) are important diagnostic tools in clinically significant prostate cancer (csPC). The aim of this study was to compare csPC detection rates with [ 68 Ga]PSMA-11-PET (PSMA)-PET, [ 11 C]Acetate (ACE)-PET, and mpMRI with histopathology as reference, to identify the most suitable imaging modalities for subsequent hybrid imaging. An additional aim was to compare inter-reader variability to assess reproducibility. METHODS: During 2016-2019, all study participants were examined with PSMA-PET/mpMRI and ACE-PET/CT prior to radical prostatectomy. PSMA-PET, ACE-PET and mpMRI were evaluated separately by two observers, and were compared with histopathology-defined csPC. Statistical analyses included two-sided McNemar test and index of specific agreement. RESULTS: Fifty-five study participants were included, with 130 histopathological intraprostatic lesions >0.05 cc. Of these, 32% (42/130) were classified as csPC with ISUP grade ≥2 and volume >0.5 cc. PSMA-PET and mpMRI showed no difference in performance ( P  = 0.48), with mean csPC detection rate of 70% (29.5/42) and 74% (31/42), respectively, while with ACE-PET the mean csPC detection rate was 37% (15.5/42). Interobserver agreement was higher with PSMA-PET compared to mpMRI [79% (26/33) vs 67% (24/38)]. Including all detected lesions from each pair of observers, the detection rate increased to 90% (38/42) with mpMRI, and 79% (33/42) with PSMA-PET. CONCLUSION: PSMA-PET and mpMRI showed high csPC detection rates and superior performance compared to ACE-PET. The interobserver agreement indicates higher reproducibility with PSMA-PET. The combined result of all observers in both PSMA-PET and mpMRI showed the highest detection rate, suggesting an added value of a hybrid imaging approach.

4.
Front Neurol ; 13: 816636, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35317351

RESUMO

Introduction: Hereditary transthyretin (ATTRv) amyloidosis caused by the V30M (p. V50M) mutation is a fatal, neuropathic systemic amyloidosis. Liver transplantation has prolonged the survival of patients and central nervous system (CNS) complications, attributed to amyloid angiopathy caused by CNS synthesis of variant transthyretin, have emerged. The study aimed to ascertain amyloid deposition within the brain in long-term ATTRv amyloidosis survivors with neurological symptoms from the CNS. Methods: A total of 20 patients with ATTR V30M having symptoms from the CNS and a median disease duration of 16 years (8-25 years) were included in this study. The cognitive and peripheral nervous functions were determined for 18 patients cross-sectionally at the time of the investigation. Amyloid brain deposits were examined by [18F]flutemetamol PET/CT. Five patients with Alzheimer's disease (AD) served as positive controls. Result: 60% of the patients with ATTRv had a pathological Z-score in the cerebellum, compared to only 20% in the patients with AD. 75% of the patients with transient focal neurological episodes (TFNEs) displayed a pathological uptake only in the cerebellum. Increased cerebellar uptake was related to an early age of onset of the ATTRv disease. 55% of the patients with ATTRv had a pathological Z-score in the global cerebral region compared to 100% of the patients with AD. Conclusion: Amyloid deposition within the brain after long-standing ATTRv amyloidosis is common, especially in the cerebellum. A cerebellar amyloid uptake profile seems to be related to TFNE symptoms.

5.
Scand J Surg ; 111(1): 14574969221083144, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35348393

RESUMO

PURPOSE: Resectability assessment of patients with colorectal liver metastases is based on computed tomography and liver magnetic resonance imaging. Addition of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography has been recommended, but the impact of the added information remains unclear. The primary aim of this study was to determine how preoperative positron emission tomography/computed tomography changed management in patients with potentially resectable colorectal liver metastases. The secondary aim was to investigate whether findings on positron emission tomography/computed tomography correlated to metastatic disease in cases with extended surgery and influenced oncological outcomes. METHODS: A retrospective observational study of the impact of adding positron emission tomography/computed tomography to conventional imaging in the surgical decision-making of colorectal liver metastases. All patients with colorectal liver metastases diagnosed by conventional imaging were included and assessed by a multidisciplinary team conference at Umeå University Hospital between June 2013 and December 2017. Eligibility criteria were all patients with potentially resectable colorectal liver metastases. Patients who underwent preoperative positron emission tomography/computed tomography in addition to conventional radiology were compared with those who underwent conventional imaging only. RESULTS: 151/220 patients underwent preoperative positron emission tomography/computed tomography. Findings on positron emission tomography/computed tomography changed the management in 10.6% of the patients. Eight patients were excluded from surgery after detection by positron emission tomography/computed tomography of extrahepatic disease. Eight patients underwent more extended surgery than initially planned due to positron emission tomography/computed tomography. Five of these positron emission tomography-positive resected sites were verified by pathology as metastatic disease. No difference in overall survival was seen following surgical resection in patients with and without a preoperative positron emission tomography/computed tomography. CONCLUSIONS: Preoperative positron emission tomography/computed tomography resulted in a changed surgical management in 10.6% of cases in a selected cohort.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Neoplasias Colorretais/patologia , Fluordesoxiglucose F18 , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos
6.
Neurosci Lett ; 770: 136420, 2022 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-34958912

RESUMO

This study aimed to explore the beneficial effects of the antioxidant N-acetylcysteine (NAC) on the degenerated dopamine system. The short- and long-term regulatory mechanisms of NAC on the 6-OHDA hemiparkinsonian rat model were longitudinally investigated by performing positron emission tomography (PET) imaging using the specific dopamine transporter (DAT) radioligand [18F]FE-PE2I. The results demonstrate that after a unilateral dopamine insult NAC has a strong influence on the non-lesioned hemisphere by decreasing the levels of DAT in the striatum early after the lesion. We interpret this early and short-term decrease of DAT in the healthy striatum of NAC-treated animals as a beneficial compensatory effect induced by NAC.


Assuntos
Acetilcisteína/farmacologia , Antioxidantes/farmacologia , Corpo Estriado/metabolismo , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Doença de Parkinson/metabolismo , Animais , Corpo Estriado/efeitos dos fármacos , Feminino , Nortropanos/farmacocinética , Oxidopamina/toxicidade , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/etiologia , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Sprague-Dawley
7.
Phys Imaging Radiat Oncol ; 18: 19-25, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34258403

RESUMO

BACKGROUND AND PURPOSE: The diagnostic accuracy of new imaging techniques requires validation, preferably by histopathological verification. The aim of this study was to develop and present a registration procedure between histopathology and in-vivo magnetic resonance imaging (MRI) of the prostate, to estimate its uncertainty and to evaluate the benefit of adding a contour-correcting registration. MATERIALS AND METHODS: For twenty-five prostate cancer patients, planned for radical prostatectomy, a 3D-printed prostate mold based on in-vivo MRI was created and an ex-vivo MRI of the specimen, placed inside the mold, was performed. Each histopathology slice was registered to its corresponding ex-vivo MRI slice using a 2D-affine registration. The ex-vivo MRI was rigidly registered to the in-vivo MRI and the resulting transform was applied to the histopathology stack. A 2D deformable registration was used to correct for specimen distortion concerning the specimen's fit inside the mold. We estimated the spatial uncertainty by comparing positions of landmarks in the in-vivo MRI and the corresponding registered histopathology stack. RESULTS: Eighty-four landmarks were identified, located in the urethra (62%), prostatic cysts (33%), and the ejaculatory ducts (5%). The median number of landmarks was 3 per patient. We showed a median in-plane error of 1.8 mm before and 1.7 mm after the contour-correcting deformable registration. In patients with extraprostatic margins, the median in-plane error improved from 2.1 mm to 1.8 mm after the contour-correcting deformable registration. CONCLUSIONS: Our registration procedure accurately registers histopathology to in-vivo MRI, with low uncertainty. The contour-correcting registration was beneficial in patients with extraprostatic surgical margins.

8.
Eur J Nucl Med Mol Imaging ; 48(6): 1822-1832, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33367948

RESUMO

PURPOSE: Hereditary transthyretin-amyloid amyloidosis (ATTRv) is an underdiagnosed condition commonly manifesting as congestive heart failure. Recently, scintigraphy utilizing DPD as a tracer was shown to identify ATTRv and wild-type ATTR cardiomyopathy. The aim of this study was to determine the value of quantified scintigraphy utilizing 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) single-photon emission computed tomography (SPECT)/CT, and to correlate its uptake with well-established cardiac functional parameters. METHODS: Forty-eight patients with genetically verified ATTRv type-A fibril composition, positive 99mTc-DPD SPECT/CT, were retrospectively analyzed. Manual mapping of volumes of interest (VOIs) on DPD SPECT/CT examinations was used to quantify heart uptake. DPD mean and maximum uptake together with a calculated DPD-based amyloid burden (DPDload) was correlated with echocardiographic strain values and cardiac biomarkers. RESULTS: Statistically significant correlations were seen in VOIs between DPD uptakes and the corresponding echocardiographic strain values. Furthermore, DPDload had a strong correlation with echocardiographic strain parameters and also correlated with biomarkers troponin T and logarithmic NT-ProBNP. CONCLUSIONS: In patients with ATTRv cardiomyopathy, DPD SPECT/CT measures the amyloid distribution and provides information on cardiac amyloid load. DPD amyloid load correlates with functional cardiac parameters.


Assuntos
Compostos de Organotecnécio , Pré-Albumina , Neuropatias Amiloides Familiares , Biomarcadores , Difosfonatos , Ecocardiografia , Humanos , Pré-Albumina/genética , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único
9.
EJNMMI Phys ; 7(1): 68, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33226495

RESUMO

BACKGROUND: Attenuation correction of PET/MRI is a remaining problem for whole-body PET/MRI. The statistical decomposition algorithm (SDA) is a probabilistic atlas-based method that calculates synthetic CTs from T2-weighted MRI scans. In this study, we evaluated the application of SDA for attenuation correction of PET images in the pelvic region. MATERIALS AND METHOD: Twelve patients were retrospectively selected from an ongoing prostate cancer research study. The patients had same-day scans of [11C]acetate PET/MRI and CT. The CT images were non-rigidly registered to the PET/MRI geometry, and PET images were reconstructed with attenuation correction employing CT, SDA-generated CT, and the built-in Dixon sequence-based method of the scanner. The PET images reconstructed using CT-based attenuation correction were used as ground truth. RESULTS: The mean whole-image PET uptake error was reduced from - 5.4% for Dixon-PET to - 0.9% for SDA-PET. The prostate standardized uptake value (SUV) quantification error was significantly reduced from - 5.6% for Dixon-PET to - 2.3% for SDA-PET. CONCLUSION: Attenuation correction with SDA improves quantification of PET/MR images in the pelvic region compared to the Dixon-based method.

10.
Cancer Imaging ; 20(1): 80, 2020 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-33129352

RESUMO

PURPOSE: To enable the evaluation of locoregional disease in the on-going RECTOPET (REctal Cancer Trial on PET/MRI/CT) study; a methodology to match mesorectal imaging findings to histopathology is presented, along with initial observations. METHODS: FDG-PET/MRI examinations were performed in twenty-four consecutively included patients with rectal adenocarcinoma. In nine patients, of whom five received neoadjuvant treatment, a postoperative MRI of the surgical specimen was performed. The pathological cut-out was performed according to clinical routine with the addition of photo documentation of each slice of the surgical specimen, meticulously marking the location, size, and type of pathology of each mesorectal finding. This allowed matching individual nodal structures from preoperative MRI, via the specimen MRI, to histopathology. RESULTS: Preoperative MRI identified 197 mesorectal nodal structures, of which 92 (47%) could be anatomically matched to histopathology. Of the matched nodal structures identified in both MRI and histopathology, 25% were found to be malignant. These malignant structures consisted of lymph nodes (43%), tumour deposits (48%), and extramural venous invasion (9%). One hundred eleven nodal structures (55%) could not be matched anatomically. Of these, 97 (87%) were benign lymph nodes, and 14 (13%) were malignant nodal structures. Five were malignant lymph nodes, and nine were tumour deposits, all of which had a short axis diameter < 5 mm. CONCLUSIONS: We designed a method able to anatomically match and study the characteristics of individual mesorectal nodal structures, enabling further research on the impact of each imaging modality. Initial observations suggest that small malignant nodal structures assessed as lymph nodes in MRI often comprise other forms of mesorectal tumour spread. TRIAL REGISTRATION: Clinical Trials Identifier: NCT03846882 .


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Retais/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/normas , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons/normas , Neoplasias Retais/patologia
11.
Amyloid ; 27(3): 191-199, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32400202

RESUMO

Background: Hereditary transthyretin amyloid (ATTRv) is a systemic amyloidosis with mainly neurological and cardiac symptoms. The aim of this study was to evaluate the outcome of [18F]Flutemetamol PET/CT-scan of the heart in long-term survivors with ATTRV30M amyloidosis.Methods: Twenty-one patients with ATTRV30M amyloidosis and predominantly neurological symptoms, mainly negative on cardiac 99mtechnetium-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD)-scintigraphy, were examined with a dynamic [18F]Flutemetamol PET/CT-scan. Five patients suffering from Alzheimer's disease and one healthy individual served as controls. Volumes of interests were drawn over the intraventricular septum, lateral wall of the left ventricle and free wall of the right ventricle. Clinical records were reviewed for data from previous completed DPD-scintigraphy of the heart and echocardiography.Results: Patients with ATTRv amyloidosis had a higher cardiac uptake than the control-group in all analysed regions of the heart and could be identified with high accuracy (sensitivity 88%, specificity 100%) in static image acquisition at 30 or 60 min. We found no correlation between cardiac [18F]Flutemetamol uptake and clinical variables.Conclusion: In this small study of selected patients, cardiac [18F]Flutemetamol PET/CT could differentiate between healthy individuals and patients with ATTRV30M. [18F]Flutemetamol PET/CT imaging of amyloidosis in patients with a negative DPD-scintigraphy has a potential as a diagnostic method.


Assuntos
Neuropatias Amiloides Familiares/metabolismo , Amiloide/genética , Proteínas Amiloidogênicas/genética , Pré-Albumina/genética , Idoso , Neuropatias Amiloides Familiares/diagnóstico por imagem , Neuropatias Amiloides Familiares/patologia , Proteínas Amiloidogênicas/isolamento & purificação , Compostos de Anilina/farmacologia , Benzotiazóis/farmacologia , Ecocardiografia , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Cardiopatias/genética , Cardiopatias/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/metabolismo , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Compostos Radiofarmacêuticos/administração & dosagem
12.
Acta Oncol ; 59(7): 799-808, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32228271

RESUMO

Background: Cachexia and sarcopenia are associated with poor survival after colorectal cancer (CRC) diagnosis. Computed tomography (CT) can be used to measure aspects of cachexia including sarcopenia, myosteatosis and the amount of subcutaneous and visceral adipose tissue. The aim of this study was to relate CT-based body composition variables with survival outcomes in CRC.Material and methods: In this population-based, retrospective cohort study, CT scans of 974 patients with pathological stages I-IV CRCs, collected at or very near diagnosis (years 2000-2016), were used to measure cross-sectional fat and muscle tissue areas. Body composition variables based on these measurements were assessed in relation to tumor stage and site and cancer-specific survival in stages I-III CRC (n = 728) using Cox proportional hazards models and Kaplan-Meier estimators.Results: Sarcopenia was associated with decreased cancer-specific survival, especially in patients with stages I-II tumors. The hazard ratio (HR) for the lowest versus highest tertile of skeletal muscle index (SMI) was 1.67; 95% confidence interval (CI), 1.08-2.58 for all stages, and HR 2.22; 95% CI 1.06-4.68, for stages I-II. Myosteatosis was also associated with decreased cancer-specific survival [(HR 2.03; 95% CI 1.20-3.34 for the lowest versus the highest tertile of skeletal muscle radiodensity (SMR)]. SMI and SMR were lower in patients with right-sided CRC, independent of age and sex. No adipose tissue measurement was significantly associated with cancer-specific survival.Conclusion: In concordance with previous studies, sarcopenia and myosteatosis were associated with decreased cancer-specific survival. The strong association between sarcopenia and poor cancer-specific survival in early-stage disease could have clinical implications for personalizing therapy decisions, including nutritional support.


Assuntos
Adenocarcinoma/patologia , Composição Corporal , Neoplasias Colorretais/patologia , Sarcopenia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adenocarcinoma/complicações , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Colo/patologia , Neoplasias Colorretais/complicações , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Estadiamento de Neoplasias , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Sarcopenia/complicações , Taxa de Sobrevida
13.
Ann Clin Transl Neurol ; 6(11): 2291-2303, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31663685

RESUMO

OBJECTIVE: The aging brain undergoes several changes, including reduced vascular, structural, and dopamine (DA) system integrity. Such brain changes have been associated with age-related cognitive deficits. However, their relative importance, interrelations, and links to risk factors remain elusive. METHODS: The present work used magnetic resonance imaging and positron emission tomography with 11 C-raclopride to jointly examine vascular parameters (white-matter lesions and perfusion), DA D2-receptor availability, brain structure, and cognitive performance in healthy older adults (n = 181, age: 64-68 years) from the Cognition, Brain, and Aging (COBRA) study. RESULTS: Covariance was found among several brain indicators, where top predictors of cognitive performance included caudate and hippocampal integrity (D2DR availability and volumes), and cortical blood flow and regional volumes. White-matter lesion burden was negatively correlated with caudate DA D2-receptor availability and white-matter microstructure. Compared to individuals with smaller lesions, individuals with confluent lesions (exceeding 20 mm in diameter) had reductions in cortical and hippocampal perfusion, striatal and hippocampal D2-receptor availability, white-matter microstructure, and reduced performance on tests of episodic memory, sequence learning, and processing speed. Higher cardiovascular risk as assessed by treatment for hypertension, systolic blood pressure, overweight, and smoking was associated with lower frontal cortical perfusion, lower putaminal D2DR availability, smaller grey-matter volumes, a larger number of white-matter lesions, and lower episodic memory performance. INTERPRETATION: Taken together, these findings suggest that reduced cardiovascular health is associated with poorer status for brain variables that are central to age-sensitive cognitive functions, with emphasis on DA integrity.


Assuntos
Envelhecimento/fisiologia , Encéfalo , Doenças Cardiovasculares/complicações , Cognição/fisiologia , Dopamina/metabolismo , Idoso , Encéfalo/metabolismo , Encéfalo/patologia , Encéfalo/fisiopatologia , Doenças Cardiovasculares/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons
14.
Cancer Imaging ; 19(1): 52, 2019 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-31337428

RESUMO

PURPOSE: The role of hybrid imaging using 18F-fluoro-2-deoxy-D-glucose positron-emission tomography (FDG-PET), computed tomography (CT) and magnetic resonance imaging (MRI) to improve preoperative evaluation of rectal cancer is largely unknown. To investigate this, the RECTOPET (REctal Cancer Trial on PET/MRI/CT) study has been launched with the aim to assess staging and restaging of primary rectal cancer. This report presents the study workflow and the initial experiences of the impact of PET/CT on staging and management of the first patients included in the RECTOPET study. METHODS: This prospective cohort study, initiated in September 2016, is actively recruiting patients from Region Västerbotten in Sweden. This pilot study includes patients recruited and followed up until December 2017. All patients had a biopsy-verified rectal adenocarcinoma and underwent a minimum of one preoperative FDG-PET/CT and FDG-PET/MRI examination. These patients were referred to the colorectal cancer multidisciplinary team meeting at Umeå University Hospital. All available data were evaluated when making management recommendations. The clinical course was noted and changes consequent to PET imaging were described; surgical specimens underwent dedicated MRI for anatomical matching between imaging and histopathology. RESULTS: Twenty-four patients have so far been included in the study. Four patients were deemed unresectable, while 19 patients underwent or were scheduled for surgery; one patient was enrolled in a watch-and-wait programme after restaging. Consequent to taking part in the study, two patients were upstaged to M1 disease: one patient was diagnosed with a solitary hepatic metastasis detected using PET/CT and underwent metastasectomy prior to rectal cancer surgery, while one patient with a small, but metabolically active, lung nodulus experienced no change of management. PET/MRI did not contribute to any recorded change in patient management. CONCLUSIONS: The RECTOPET study investigating the role of PET/CT and PET/MRI for preoperative staging of primary rectal cancer patients will provide novel data that clarify the value of adding hybrid to conventional imaging, and the role of PET/CT versus PET/MRI. TRIAL REGISTRATION: NCT03846882 .


Assuntos
Adenocarcinoma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias Retais/diagnóstico por imagem , Adenocarcinoma/patologia , Adulto , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos , Neoplasias Retais/patologia
15.
EJNMMI Phys ; 6(1): 2, 2019 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-30631980

RESUMO

BACKGROUND: 68Ga-labeled Glu-NH-CO-NH-Lys(Ahx)-HBED-CC ([68Ga]PSMA-11) has been increasingly used to image prostate cancer using positron emission tomography (PET)/computed tomography (CT) both during diagnosis and treatment planning. It has been shown to be of clinical value for patients both in the primary and secondary stages of prostate cancer. The aim of this study was to determine the effective dose and organ doses from injection of [68Ga]PSMA-11 in a cohort of low-risk prostate cancer patients. METHODS: Six low-risk prostate cancer patients were injected with 133-178 MBq [68Ga]PSMA-11 and examined with four PET/CT acquisitions from injection to 255 min post-injection. Urine was collected up to 4 h post-injection, and venous blood samples were drawn at 45 min, 85 min, 175 min, and 245 min post-injection. Kidneys, liver, lungs, spleen, salivary and lacrimal glands, and total body where delineated, and cumulated activities and absorbed organ doses calculated. The software IDAC-Dose 2.1 was used to calculate absorbed organ doses according to the International Commission on Radiological Protection (ICRP) publication 107 using specific absorbed fractions published in ICRP 133 and effective dose according to ICRP Publication 103. We also estimated the absorbed dose to the eye lenses using Monte Carlo methods. RESULTS: [68Ga]PSMA-11 was rapidly cleared from the blood and accumulated preferentially in the kidneys and the liver. The substance has a biological half-life in blood of 6.5 min (91%) and 4.4 h (9%). The effective dose was calculated to 0.022 mSv/MBq. The kidneys received approximately 40 mGy after an injection with 160 MBq [68Ga]PSMA-11 while the lacrimal glands obtained an absorbed dose of 0.12 mGy per administered MBq. Regarding the eye lenses, the absorbed dose was low (0.0051 mGy/MBq). CONCLUSION: The effective dose for [68Ga]PSMA-11 is 0.022 mSv/MBq, where the kidneys and lacrimal glands receiving the highest organ dose.

16.
PLoS One ; 13(12): e0209169, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30543705

RESUMO

INTRODUCTION: 11C-acetate (ACE)-PET/CT is used for staging of high-risk prostate cancer. PET data is reconstructed with iterative algorithms, such as VUEPointHD ViP (VPHD) and VUEPoint HD Sharp IR (SharpIR), the latter with additional resolution recovery. It is expected that the resolution recovery algorithm should render more accurate maximum and mean standardized uptake values (SUVmax and SUVmean) and functional tumor volumes (FTV) than the ordinary OSEM. Performing quantitative analysis, choice of volume-of-interest delineation algorithm (SUV threshold) may influence FTV. Optimizing PET acquisition time is justified if image quality and quantitation do not deteriorate. The aim of this study is to identify the optimal reconstruction algorithm, SUV threshold and acquisition time for ACE-PET/CT. METHODS: ACE-PET/CT data acquired with a General Electric Discovery 690 PET/CT from 16 consecutive high-risk prostate cancer patients was reconstructed with VPHD and SharpIR. Forty pelvic lymph nodes (LNs) and 14 prostate glands were delineated with 42% and estimated threshold. SUVmax, SUVmean, FTV and total lesion uptake were measured. Default acquisition time was four minutes per bed position. In a subset of lesions, acquisition times of one, two and four minutes were evaluated. Structural tumor volumes (STV) of the LNs were measured with CT for correlation with functional volumetric parameters. To validate SUV quantification under different conditions with SharpIR 42%, recovery coefficients (RCs) of SUVmean and FTV were calculated from a phantom with 18F-fluoro-deoxy-glucose (FDG)-filled volumes 0.1-9.2cm3 and signal-to-background (S/B) ratios 4.3-15.9. RESULTS: With SharpIR, SUVmax and SUVmean were higher and FTV lower compared with VPHD, regardless of threshold method, in both prostates and LNs. Total lesion uptake determined with both threshold methods was lower with SharpIR compared with VPHD with both threshold methods, except in subgroup analysis of prostate targets where estimated threshold returned higher values. Longer acquisition times returned higher FTV for both threshold methods, regardless of reconstruction algorithm. The FTV difference was most pronounced with one minute's acquisition per bed position, which also produced visually the highest noise. SUV parameters were unaffected by varying acquisition times. FTV with SharpIR 42% showed the best correspondence with STV. SharpIR 42% gave higher RCs of SUVmean and FTV with increasing phantom size and S/B-ratio, as expected. CONCLUSIONS: Delineation with SharpIR 42% seems to provide the most accurate combined information from SUVmax, SUVmean, FTV and total lesion uptake. Acquisition time may be shortened to two minutes per bed position with preserved image quality.


Assuntos
Acetatos/metabolismo , Algoritmos , Radioisótopos de Carbono , Processamento de Imagem Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Transporte Biológico , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/metabolismo , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Risco , Fatores de Tempo
17.
Med Phys ; 2018 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-29862522

RESUMO

PURPOSE: Simultaneous collection of PET and MR data for radiotherapy purposes are useful for, for example, target definition and dose escalations. However, a prerequisite for using PET/MR in the radiotherapy workflow is the ability to image the patient in treatment position. The aim of this work was to adapt a GE SIGNA PET/MR scanner to image patients for radiotherapy treatment planning and evaluate the impact on signal-to-noise (SNR) of the MR images, and the accuracy of the PET attenuation correction. METHOD: A flat tabletop and a coil holder were developed to image patients in the treatment position, avoid patient contour deformation, and facilitate attenuation correction of flex coils. Attenuation corrections for the developed hardware and an anterior array flex coil were also measured and implemented to the PET/MR system to minimize PET quantitation errors. The reduction of SNR in the MR images due to the added distance between the coils and the patient was evaluated using a large homogenous saline-doped water phantom, and the activity quantitation errors in PET imaging were evaluated with and without the developed attenuation corrections. RESULT: We showed that the activity quantitation errors in PET imaging were within ±5% when correcting for attenuation of the flat tabletop, coil holder, and flex coil. The SNR of the MRI images were reduced to 74% using the tabletop, and 66% using the tabletop and coil holders. CONCLUSION: We present a tabletop and coil holder for an anterior array coil to be used with a GE SIGNA PET/MR scanner, for scanning patients in the radiotherapy work flow. Implementing attenuation correction of the added hardware from the radiotherapy setup leads to acceptable PET image quantitation. The drop in SNR in MR images may require adjustment of the imaging protocols.

18.
Phys Med ; 35: 1-6, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28283354

RESUMO

PURPOSE: Attenuation correction is a requirement for quantification of the activity distribution in PET. The need to base attenuation correction on MRI instead of CT has arisen with the introduction of integrated PET/MRI systems. The aim was to describe the effect of residual gradient field nonlinearity distortions on PET attenuation correction. METHODS: MRI distortions caused by gradient field nonlinearity were simulated in CT images used for attenuation correction in PET reconstructions. The simulations yielded radial distortion of up to ±2.3mm at 15cm from the scanner isocentre for distortion corrected images. The mean radial distortion of uncorrected images were 6.3mm at the same distance. Reconstructions of PET data were performed using the distortion corrected images as well as the images where no correction had been applied. RESULTS: The mean relative difference in reconstructed PET uptake intensity due to incomplete distortion correction was less than ±5%. The magnitude of this difference varied between patients and the size of the distortions remaining after distortion correction. CONCLUSIONS: Radial distortions of 2mm at 15cm radius from the scanner isocentre lead to PET attenuation correction errors smaller than 5%. Keeping the gradient field nonlinearity distortions below this limit can be a reasonable goal for MRI systems used for attenuation correction in PET for quantification purposes. A higher geometrical accuracy may, however, be warranted for quantification of peripheral lesions. These distortions can, e.g., be controlled at acceptance testing and subsequent quality assurance intervals.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Algoritmos , Artefatos , Simulação por Computador , Humanos , Masculino , Dinâmica não Linear , Neoplasias da Próstata/diagnóstico por imagem
19.
Anticancer Res ; 36(12): 6475-6479, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27919970

RESUMO

AIM: The aim of this study was to evaluate the detection rate of bone metastases and the added value of 11C-acetate (ACE) positron-emission tomography/computed tomography (PET/CT) compared to bone scintigraphy (BS) in high-risk prostate cancer (PC). MATERIALS AND METHODS: A total of 66 untreated patients with high-risk PC with ACE-PET/CT and planar BS findings within 3 months of each other were retrospectively enrolled. Findings were compared and verified with follow-up data after an average of 26 months. RESULTS: The rate of detection of bone metastases was superior with ACE-PET/CT compared to BS (p<0.01). Agreement between the methods and between BS and follow-up was moderate (Cohen's kappa coefficient of 0.64 and 0.66, respectively). Agreement between ACE-PET/CT and follow-up was excellent (kappa coefficient of 0.95). Therapy was changed in 11% of patients due to ACE-PET/CT results. CONCLUSION: ACE-PET/CT performed better than planar BS in detection of bone metastases in high-risk PC. ACE-PET/CT findings influenced clinical management.


Assuntos
Acetatos/administração & dosagem , Imagem Multimodal , Compostos de Organotecnécio/administração & dosagem , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Fatores de Risco , Tomografia Computadorizada por Raios X
20.
J Comput Assist Tomogr ; 38(2): 209-15, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24625616

RESUMO

OBJECTIVE: The objective of this study was to compare the accuracy of calculating the primary tumor volumes using a gradient-based method and fixed threshold methods on the standardized uptake value (SUV) maps and the net influx of FDG (Ki) maps from positron emission tomography-computed tomography (PET-CT) images. MATERIALS AND METHODS: Newly diagnosed patients with head and neck cancer were recruited, and dynamic PET-CT scan and T2-weighted magnetic resonance imaging were performed. The maps of Ki and SUV were calculated from PET-CT images. The tumor volumes were calculated using a gradient-based method and a fixed threshold method at 40% of maximal SUV or maximal Ki. Four kinds of volumes, VOLKi-Gra (from the Ki maps using the gradient-based method), VOLKi-40% (from the Ki maps using the threshold of 40% maximal Ki), VOLSUV-Gra (from the SUV maps using the gradient-based method), and VOLSUV-40% (from the SUV maps using the threshold of 40% maximal SUV), were acquired and compared with VOLMRI (the volumes acquired on T2-weighted images) using the Pearson correlation, paired t test, and similarity analysis. RESULTS: Eighteen patients were studied, of which 4 had poorly defined tumors (PDT). The positron emission tomography-derived volumes were as follows: VOLSUV-40%, 2.1 to 41.2 cm (mean [SD], 12.3 [10.6]); VOLSUV-Gra, 2.2 to 28.1 cm (mean [SD], 13.2 [8.4]); VOLKi-Gra, 2.4 to 17.0 cm (mean [SD], 9.5 [4.6]); and VOLKi-40%, 2.7 to 20.3 cm (mean [SD], 12.0 [6.0]). The VOLMRI ranged from 2.9 to 18.1 cm (mean [SD], 9.1 [3.9]). The VOLKi-Gra significantly correlated with VOLMRI with the highest correlation coefficient (PDT included, R = 0.673, P = 0.002; PDT excluded, R = 0.841, P < 0.001) and presented no difference from VOLMRI (P = 0.672 or 0.561, respectively, PDT included and excluded). The difference between VOLKi-Gra and VOLMRI was also the smallest. CONCLUSIONS: The tumor volumes delineated on the Ki maps using the gradient-based method are more accurate than those on the SUV maps and using the fixed threshold methods.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem Multimodal , Carga Tumoral , Adulto , Idoso , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Interpretação de Imagem Assistida por Computador , Iopamidol , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA