Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
JHEP Rep ; 6(1): 100957, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38234407

RESUMO

Background & Aims: The diagnosis of hepatocellular carcinoma (HCC) in patients with cirrhosis relies on non-invasive criteria based on international guidelines. The advent of systemic therapies warrants reconsideration of the role of biopsy specimens in the diagnosis of HCC. Accordingly, we investigated the diagnostic performance of the LI-RADS 2018 and the AASLD 2011 criteria. Methods: Consecutive patients with cirrhosis who underwent a biopsy for suspected HCC between 2015 and 2020 were included. The available imaging studies (computed tomography and/or magnetic resonance imaging) were blindly reviewed by two independent radiologists. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were assessed for LI-RADS, AASLD, and biopsies. Results: In total, 167 patients underwent both available biopsy and imaging. Of the 137 relevant biopsies, 114 patients had HCC (83.2%), 12 (9%) had non-HCC malignant lesions, and 11 (8%) had benign nodules. The PPV and NPV of the biopsies were 100% and 62%, respectively; 30 biopsies were non-contributive. The PPV and NPV of the LI-RADS categories were 89% and 32.8% for LR-5 and 85.5% and 54.5% for LR-4 + 5 + TIV, respectively. The PPV and NPV of the 2011 AASLD criteria were 93.2% and 35.6%, respectively. The interobserver kappa (k = 0.380) for the LR-5 categories was reasonable. Of 100 LR-5 nodules, 11 were misclassified, in particular one case was a colorectal metastasis, and two cases were cholangiocarcinomas, of which nine were identified through biopsy, whereas six were correctly classified according to LI-RADS (LR-M or LR-TIV). Fifty percent of macrotrabecular HCC and 48.4% of poorly differentiated HCC (Edmonson 3 and 4) were not classified as LR-5. Conclusions: LI-RADS 2018 did not outperform the AASLD 2011 score as a non-invasive diagnosis of HCC. Tumor biopsy allowed restoration of an accurate diagnosis in 11% of LR-5 cases. A combined radiological and histological diagnosis should be considered mandatory for good treatment assessment. Impact and Implications: Although biopsy is not required for hepatocellular carcinoma diagnosis when the LI-RADS criteria are met according to current guidelines, our study underscores the limits of radiology and the need for biopsy when hepatocellular carcinoma is suspected. Histological findings could change therapeutics of liver tumors even if only for a small proportion of patients. Histological proof of the type of cancer is a standard in oncology.

2.
Invest Radiol ; 58(11): 791-798, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37289274

RESUMO

OBJECTIVES: This study proposes and evaluates a deep learning method to detect pancreatic neoplasms and to identify main pancreatic duct (MPD) dilatation on portal venous computed tomography scans. MATERIALS AND METHODS: A total of 2890 portal venous computed tomography scans from 9 institutions were acquired, among which 2185 had a pancreatic neoplasm and 705 were healthy controls. Each scan was reviewed by one in a group of 9 radiologists. Physicians contoured the pancreas, pancreatic lesions if present, and the MPD if visible. They also assessed tumor type and MPD dilatation. Data were split into a training and independent testing set of 2134 and 756 cases, respectively.A method to detect pancreatic lesions and MPD dilatation was built in 3 steps. First, a segmentation network was trained in a 5-fold cross-validation manner. Second, outputs of this network were postprocessed to extract imaging features: a normalized lesion risk, the predicted lesion diameter, and the MPD diameter in the head, body, and tail of the pancreas. Third, 2 logistic regression models were calibrated to predict lesion presence and MPD dilatation, respectively. Performance was assessed on the independent test cohort using receiver operating characteristic analysis. The method was also evaluated on subgroups defined based on lesion types and characteristics. RESULTS: The area under the curve of the model detecting lesion presence in a patient was 0.98 (95% confidence interval [CI], 0.97-0.99). A sensitivity of 0.94 (469 of 493; 95% CI, 0.92-0.97) was reported. Similar values were obtained in patients with small (less than 2 cm) and isodense lesions with a sensitivity of 0.94 (115 of 123; 95% CI, 0.87-0.98) and 0.95 (53 of 56, 95% CI, 0.87-1.0), respectively. The model sensitivity was also comparable across lesion types with values of 0.94 (95% CI, 0.91-0.97), 1.0 (95% CI, 0.98-1.0), 0.96 (95% CI, 0.97-1.0) for pancreatic ductal adenocarcinoma, neuroendocrine tumor, and intraductal papillary neoplasm, respectively. Regarding MPD dilatation detection, the model had an area under the curve of 0.97 (95% CI, 0.96-0.98). CONCLUSIONS: The proposed approach showed high quantitative performance to identify patients with pancreatic neoplasms and to detect MPD dilatation on an independent test cohort. Performance was robust across subgroups of patients with different lesion characteristics and types. Results confirmed the interest to combine a direct lesion detection approach with secondary features such as the MPD diameter, thus indicating a promising avenue for the detection of pancreatic cancer at early stages.


Assuntos
Adenocarcinoma Mucinoso , Carcinoma Ductal Pancreático , Aprendizado Profundo , Neoplasias Pancreáticas , Humanos , Dilatação , Adenocarcinoma Mucinoso/diagnóstico , Adenocarcinoma Mucinoso/patologia , Neoplasias Pancreáticas/diagnóstico , Carcinoma Ductal Pancreático/diagnóstico , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/patologia , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos
3.
Invest Radiol ; 57(8): 527-535, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35446300

RESUMO

OBJECTIVES: The aim of this study was to evaluate a deep learning method designed to increase the contrast-to-noise ratio in contrast-enhanced gradient echo T1-weighted brain magnetic resonance imaging (MRI) acquisitions. The processed images are quantitatively evaluated in terms of lesion detection performance. MATERIALS AND METHODS: A total of 250 multiparametric brain MRIs, acquired between November 2019 and March 2021 at Gustave Roussy Cancer Campus (Villejuif, France), were considered for inclusion in this retrospective monocentric study. Independent training (107 cases; age, 55 ± 14 years; 58 women) and test (79 cases; age, 59 ± 14 years; 41 women) samples were defined. Patients had glioma, brain metastasis, meningioma, or no enhancing lesion. Gradient echo and turbo spin echo with variable flip angles postcontrast T1 sequences were acquired in all cases. For the cases that formed the training sample, "low-dose" postcontrast gradient echo T1 images using 0.025 mmol/kg injections of contrast agent were also acquired. A deep neural network was trained to synthetically enhance the low-dose T1 acquisitions, taking standard-dose T1 MRI as reference. Once trained, the contrast enhancement network was used to process the test gradient echo T1 images. A read was then performed by 2 experienced neuroradiologists to evaluate the original and processed T1 MRI sequences in terms of contrast enhancement and lesion detection performance, taking the turbo spin echo sequences as reference. RESULTS: The processed images were superior to the original gradient echo and reference turbo spin echo T1 sequences in terms of contrast-to-noise ratio (44.5 vs 9.1 and 16.8; P < 0.001), lesion-to-brain ratio (1.66 vs 1.31 and 1.44; P < 0.001), and contrast enhancement percentage (112.4% vs 85.6% and 92.2%; P < 0.001) for cases with enhancing lesions. The overall image quality of processed T1 was preferred by both readers (graded 3.4/4 on average vs 2.7/4; P < 0.001). Finally, the proposed processing improved the average sensitivity of gradient echo T1 MRI from 88% to 96% for lesions larger than 10 mm ( P = 0.008), whereas no difference was found in terms of the false detection rate (0.02 per case in both cases; P > 0.99). The same effect was observed when considering all lesions larger than 5 mm: sensitivity increased from 70% to 85% ( P < 0.001), whereas false detection rates remained similar (0.04 vs 0.06 per case; P = 0.48). With all lesions included regardless of their size, sensitivities were 59% and 75% for original and processed T1 images, respectively ( P < 0.001), and the corresponding false detection rates were 0.05 and 0.14 per case, respectively ( P = 0.06). CONCLUSION: The proposed deep learning method successfully amplified the beneficial effects of contrast agent injection on gradient echo T1 image quality, contrast level, and lesion detection performance. In particular, the sensitivity of the MRI sequence was improved by up to 16%, whereas the false detection rate remained similar.


Assuntos
Meios de Contraste , Aprendizado Profundo , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Redução da Medicação , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Invest Radiol ; 57(2): 99-107, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34324463

RESUMO

MATERIALS AND METHODS: This monocentric retrospective study leveraged 200 multiparametric brain MRIs acquired between November 2019 and February 2020 at Gustave Roussy Cancer Campus (Villejuif, France). A total of 145 patients were included: 107 formed the training sample (55 ± 14 years, 58 women) and 38 the separate test sample (62 ± 12 years, 22 women). Patients had glioma, brain metastases, meningioma, or no enhancing lesion. T1, T2-FLAIR, diffusion-weighted imaging, low-dose, and standard-dose postcontrast T1 sequences were acquired. A deep network was trained to process the precontrast and low-dose sequences to predict "virtual" surrogate images for contrast-enhanced T1. Once trained, the deep learning method was evaluated on the test sample. The discrepancies between the predicted virtual images and the standard-dose MRIs were qualitatively and quantitatively evaluated using both automated voxel-wise metrics and a reader study, where 2 radiologists graded image qualities and marked all visible enhancing lesions. RESULTS: The automated analysis of the test brain MRIs computed a structural similarity index of 87.1% ± 4.8% between the predicted virtual sequences and the reference contrast-enhanced T1 MRIs, a peak signal-to-noise ratio of 31.6 ± 2.0 dB, and an area under the curve of 96.4% ± 3.1%. At Youden's operating point, the voxel-wise sensitivity (SE) and specificity were 96.4% and 94.8%, respectively. The reader study found that virtual images were preferred to standard-dose MRI in terms of image quality (P = 0.008). A total of 91 reference lesions were identified in the 38 test T1 sequences enhanced with full dose of contrast agent. On average across readers, the brain lesion SE of the virtual images was 83% for lesions larger than 10 mm (n = 42), and the associated false detection rate was 0.08 lesion/patient. The corresponding positive predictive value of detected lesions was 92%, and the F1 score was 88%. Lesion detection performance, however, dropped when smaller lesions were included: average SE was 67% for lesions larger than 5 mm (n = 74), and 56% with all lesions included regardless of their size. The false detection rate remained below 0.50 lesion/patient in all cases, and the positive predictive value remained above 73%. The composite F1 score was 63% at worst. CONCLUSIONS: The proposed deep learning method for virtual contrast-enhanced T1 brain MRI prediction showed very high quantitative performance when evaluated with standard voxel-wise metrics. The reader study demonstrated that, for lesions larger than 10 mm, good detection performance could be maintained despite a 4-fold division in contrast agent usage, unveiling a promising avenue for reducing the gadolinium exposure of returning patients. Small lesions proved, however, difficult to handle for the deep network, showing that full-dose injections remain essential for accurate first-line diagnosis in neuro-oncology.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Neoplasias Encefálicas/diagnóstico por imagem , Meios de Contraste , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA