Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Long Term Eff Med Implants ; 34(2): 61-68, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38305371

RESUMO

Due to the high rate of rotator cuff re-tear there is an extensive research on augmentation of rotator cuff repairs. The purpose of this single center, prospective study was to evaluate the results of augmentation of the rotator cuff repair with an umbilical cord allograft. The graft group in which the rotator cuff repair was augmented with the graft as an on-lay patch was consisted of 14 patients, while the control group was consisted of 10 patients. The primary outcome of the study was incidence of rotator cuff retears, while secondary outcomes included functional and pain scores. At 6 mo there was a significantly higher incidence of retears in the control group (30%) compared to the graft group (0%; P = 0.028), while at 12 mo the retear rates were statistically similar for the two groups (P = 0.46). The Constant-Murley scores, the ASES scores and the VAS score were similar (P > 0.05) for the two groups at all study times. The results of the study indicated that augmentation of the cuff repair with human umbilical cord graft can result in similar patient reported outcomes compared to a cuff repair without augmentation, but with a lower re-tear rate at 6 mo.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Manguito Rotador/cirurgia , Estudos Prospectivos , Artroscopia , Lesões do Manguito Rotador/cirurgia , Ruptura , Resultado do Tratamento , Imageamento por Ressonância Magnética
2.
Cureus ; 15(6): e41068, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37519524

RESUMO

Osteoid osteomas of the talus are rarely seen. They can easily be misdiagnosed. In this case report, we present a 21-year-old man with an osteoid osteoma in the talar neck whose pain onset coincided with an ankle injury. The latter was deemed a misleading factor when making a diagnosis. Eventually, the patient was treated with surgical excision of the osteoid osteoma. The gap that resulted after the excision was filled with an autologous bone graft. A year after his operation, the patient returned to his daily activities and remained pain-free. A high index of suspicion and an appropriate imaging examination are mandated for the early diagnosis of such entities.

3.
Eur J Orthop Surg Traumatol ; 33(8): 3531-3538, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37212913

RESUMO

PURPOSE: The outcomes of shoulder hemiarthroplasty are highly dependent on the baseline glenoid morphology and the rotator cuff integrity. The objective of this study was to assess whether certain glenoid parameters and implant overstuffing are associated with worse clinical outcomes following shoulder hemiarthroplasty. METHODS: We retrospectively reviewed 25 patients who underwent shoulder hemiarthroplasty for shoulder arthritis, with a mean follow-up of 5.3 years. The baseline glenoid morphology, the glenoid wear rate, the proximal humeral head migration and implant overstuffing were evaluated radiologically in all patients. The radiological parameters were correlated with the functional outcomes. RESULTS: The Constant-Murley score, the ASES score, and the OSS score were significantly better for patients with a concentric baseline glenoid compared to those with an eccentric glenoid. The Constant-Murley score and the ASES score were also improved in patients without implant overstuffing compared to patients with implant overstuffing (p < 0.05). However, glenoid wear was not associated with worse functional outcomes (p = 0.23 for Constant-Murley score, p = 0.15 for ASES score and p = 0.27 for OSS score). Last, a worse Constant-Murley score was strongly correlated with proximal humeral head migration (p < 0.001), while worse ASES and OSS scores were moderately correlated with proximal humeral head migration (p < 0.001). CONCLUSION: Our findings indicate that the results of hemiarthroplasty can be improved through careful selection of patients upon the baseline glenoid type morphology and proper implant sizing to avoid implant overstuffing. Moreover, glenoid wear is not associated with worse clinical outcomes, therefore shoulder hemiarthroplasty should be reconsidered as an alternative in younger patients with shoulder arthritis.


Assuntos
Artrite , Hemiartroplastia , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Hemiartroplastia/efeitos adversos , Hemiartroplastia/métodos , Estudos Retrospectivos , Seguimentos , Ombro/cirurgia , Artrite/etiologia
4.
Int Orthop ; 46(8): 1681-1692, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35641792

RESUMO

PURPOSE: Using serum biomarkers, this systematic review assessed soft tissue injury following different total hip arthroplasty surgical approaches. The purposes were to determine if there is any advantage between the standard and minimal invasive approaches, and to compare tissue damage of the respective surgical approaches using biomarkers such as creatine kinase, myoglobin, c-reactive protein, erythrocyte sedimentation rate, skeletal troponin and interleukins. METHOD: A search in Pubmed/MEDLINE, Scopus and Web of Science databases was conducted in October 2021 with the use of PRISMA guidelines. Search items were ("biomarkers" OR "markers" OR "tissue damage" OR "muscle damage") AND "approach" AND ("total hip arthroplasty" OR "total hip replacement"). Inclusion criteria were prospective, randomized, controlled trials or prospective, comparative studies, comparing serum markers for muscle damage in two or more surgical approaches for primary total hip arthroplasty. Exclusion criteria were study protocols, case reports, systematic reviews, meta-analyses, studies in non-English language or without available full text, and studies not recording biomarkers of muscle damage. RESULTS: Initial search revealed 508 studies; after subtraction of duplicates, and exclusion criteria, 31 studies remained for analysis. No advantage between different approaches was found when evaluating biomarkers, and no specific biomarkers had a distinct role in tissue damage in total hip arthroplasty. Anterior and minimally invasive approaches were associated with lower values of soft tissue (creatine kinase) and inflammation (c-reactive protein) biomarkers compared to the standard approaches. CONCLUSION: Measurement of serum biomarkers after primary total hip arthroplasty for the estimation of tissue damage has unclear or little clinical value. TRIAL REGISTRATION: PROSPERO Registration: CRD42022303959.


Assuntos
Artroplastia de Quadril , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Biomarcadores , Proteína C-Reativa/metabolismo , Creatina Quinase , Humanos , Músculos/metabolismo , Estudos Prospectivos
6.
Bone Joint J ; 103-B(3): 442-448, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33641430

RESUMO

AIMS: The aim of this study was to investigate the hypothesis that a single dose of tranexamic acid (TXA) would reduce blood loss and transfusion rates in elderly patients undergoing surgery for a subcapital or intertrochanteric (IT) fracture of the hip. METHODS: In this single-centre, randomized controlled trial, elderly patients undergoing surgery for a hip fracture, either hemiarthroplasty for a subcapital fracture or intramedullary nailing for an IT fracture, were screened for inclusion. Patients were randomly allocated to a study group using a sealed envelope. The TXA group consisted of 77 patients, (35 with a subcapital fracture and 42 with an IT fracture), and the control group consisted of 88 patients (29 with a subcapital fracture and 59 with an IT fracture). One dose of 15 mg/kg of intravenous (IV) TXA diluted in 100 ml normal saline (NS,) or one dose of IV placebo 100 ml NS were administered before the incision was made. The haemoglobin (Hb) concentration was measured before surgery and daily until the fourth postoperative day. The primary outcomes were the total blood loss and the rate of transfusion from the time of surgery to the fourth postoperative day. RESULTS: Homogeneity with respect to baseline characteristics was ensured between groups. The mean total blood loss was significantly lower in patients who received TXA (902.4 ml (-279.9 to 2,156.9) vs 1,226.3 ml (-269.7 to 3,429.7); p = 0.003), while the likelihood of requiring a transfusion of at least one unit of red blood cells was reduced by 22%. Subgroup analysis showed that these differences were larger in patients who had an IT fracture compared with those who had a subcapital fracture. CONCLUSION: Elderly patients who undergo intramedullary nailing for an IT fracture can benefit from a single dose of 15 mg/kg TXA before the onset of surgery. A similar tendency was identified in patients undergoing hemiarthroplasty for a subcapital fracture but not to a statistically significant level. Cite this article: Bone Joint J 2021;103-B(3):442-448.


Assuntos
Antifibrinolíticos/administração & dosagem , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue/estatística & dados numéricos , Fraturas do Quadril/cirurgia , Ácido Tranexâmico/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação de Fratura/métodos , Hemoglobinas/análise , Humanos , Masculino , Pessoa de Meia-Idade
7.
Hip Int ; 31(3): 295-303, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32297561

RESUMO

AIMS: Modular-neck femoral implants are used to enable more variability in femoral neck version, offset and length. It has been reported that these implants carry a higher rate of revision. The aim of this review was to assess the overall and cause-specific revision rate of titanium-titanium alloy modular-neck implants in primary total hip arthroplasty (THA). METHODS: A systematic review was conducted following PRISMA guidelines and utilising multiple databases. All results were screened for eligibility. Studies published from 2000 onwards, using a current-generation, titanium-titanium, modular-neck implant were included. Overall and cause-specific revision rates were analysed, comparing to fixed-neck prostheses where applicable. RESULTS: 920 studies were screened. After applying exclusion criteria, 23 were assessed in full and 14 included. These consisted of 12 case series and 2 joint registry analyses. 21,841 patients underwent a modular-neck implant with a weighted mean follow-up of 5.7 years, mean age of 62.4 years, and average body mass index (BMI) of 28.4kg/m2. The overall revision rate was 3.95% and 2.98% for modular and fixed-neck prostheses, respectively. For studies with >5 years follow-up the mean revision rate was 3.08%. There was no difference in cause-specific revision rates by implant design. Mean improvement in Harris Hip Score was 41.9. CONCLUSIONS: At medium-term, revision rates for titanium-titanium primary modular-neck THA are acceptable. These prostheses are a sensible management option in patients with considerable anatomical hip deformity not amenable to correction with standard fixed-neck implants. Patients of male gender, high BMI and requiring prostheses with a larger neck, offset or head are at higher risk of implant failure.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Titânio
9.
J Hand Surg Eur Vol ; 45(4): 360-368, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31399010

RESUMO

Reconstruction of the interosseous membrane has the potential to re-establish a normal loading pattern through the forearm and enhance stability after an Essex-Lopresti lesion. The aim of our study was to assess the capacity of three different techniques, which all use a regionally harvested autograft, to restore longitudinal stability. Simulation of the Essex-Lopresti lesion was done by excising the radial head and sectioning the interosseous membrane in seven cadaveric specimens. Each technique was used in each specimen consecutively, using the pronator teres, the brachioradialis and the flexor carpi radialis tendons, respectively. The specimens were submitted to mechanical testing by applying proximally migratory forces to the radius and radioulnar displacement was assessed fluroscopically at wrist level. The pronator teres tendon achieved the greatest reduction (94% correction with respect to the intact interosseous membrane/radial head out state, followed by brachioradialis (92%) and flexor carpi radialis (85%). However, no statistically significant differences in displacement data or strength were detected between the techniques.


Assuntos
Antebraço , Membrana Interóssea , Fenômenos Biomecânicos , Cadáver , Antebraço/cirurgia , Humanos , Rádio (Anatomia) , Tendões/cirurgia , Articulação do Punho/cirurgia
11.
Acta Orthop Belg ; 85(1): 63-71, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31023201

RESUMO

Longitudinal stability of the forearm is mainly provided by three structures: the radiocapitellar contact, which acts as the primary stabilizer, the central band of the interosseous ligamentous complex (IOLC) and the intact triangular fibrocartilage complex (TFCC). In an Essex-Lopresti lesion the forearm becomes fully destabilized, since all of these three components are injured. Fixation or replacement of the radial head with a metallic prosthesis along with repair of the TFCC and stabilization of the distal radioulnar joint (DRUJ) are well-established treatment goals. However the reconstruction of the central band of the IOLC remains to some extent controversial. The authors believe that the reconstruction of the central band, particularly in active patients, is crucial in order to restore normal load distribution through the forearm, thus ensuring both transverse and longitudinal stability. In this article, we present a case with an Essex-Lopresti lesion, which was effectively treated acutely with restoration of all three components of the injury (radial head prosthesis, DRUJ repair and reconstruction of the central band of the IOLC). A novel technique by rerouting the brachioradialis tendon is described in detail.


Assuntos
Fraturas Cominutivas/cirurgia , Prótese Articular , Procedimentos de Cirurgia Plástica/métodos , Fraturas do Rádio/cirurgia , Rádio (Anatomia)/cirurgia , Tendões/cirurgia , Humanos , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade
13.
Eur J Orthop Surg Traumatol ; 29(1): 1-8, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30022241

RESUMO

A series of clinical trials focused on the use of ultrasound-guided platelet-rich plasma (PRP) infusions for the treatment of patients with carpal tunnel syndrome (CTS) were published over the last few years. However, the role of PRP for CTS remains unclear. We performed a systematic review according to Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines. Two reviewers independently conducted the search using multiple databases: MEDLINE/PubMed, SCOPUS, Cochrane Database, and Web of Science. These databases were searched using terms "platelet" AND "rich" AND "plasma" AND "carpal" AND "tunnel". To maximize the search, backward chaining of references from retrieved papers was also undertaken. From the initial 19 studies, only five met our eligibility criteria. These articles included one randomized controlled double-blind study, one randomized controlled single-blind study, one randomized controlled non-blind study, one case-control study, and one case report. The vast majority of the included studies supported that PRP infusion improved the clinical condition of the patients and that PRP infusion was beneficial for patients with mild-to-moderate CTS. Therefore, PRP seems to be an interesting alternative for the treatment of mild-to-moderate CTS which, still, has not been thoroughly investigated. However, despite the promising results of the present studies, PRP has to be further tested before we reach to a definite conclusion regarding its therapeutic value.


Assuntos
Síndrome do Túnel Carpal/terapia , Plasma Rico em Plaquetas , Humanos , Condução Nervosa , Medição da Dor
14.
Ann Transl Med ; 6(12): 243, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30069445

RESUMO

BACKGROUND: Given that apoptosis of chondrocytes is one of the most important factors related to the pathogenesis of osteoarthritis (OA), the recent research interest adds progress not only to the knowledge of the molecular signals that mediate apoptosis but also to find new therapeutic targets. This study attempts to investigate the differential expression of BCL2 family genes in the articular cartilage of an experimental animal model of OA. METHODS: In total, 26 New Zealand white rabbits underwent an anterior cruciate ligament transaction, 26 more were subjected to a placebo surgery and 18 specimens constituted the control non-operated group. Thirteen weeks later, samples of cartilage from the osteoarthritic and non-osteoarthritic knees were collected and subjected to analysis of the BCL2, BAX and BCL2L12 gene expression at the mRNA level. RESULTS: Installed osteoarthritic alterations of varied intensity and of grade 1 up to grade 5, were confirmed according to the OARSI system. Contrary to the physiologically healthy samples, in the osteoarthritic samples the mRNA expression levels of BAX and BCL2L12 genes were found significantly upregulated by signals which can activate apoptosis. However, the difference between BCL2 mRNA expression levels in healthy and osteoarthritic samples was not supported statistically. CONCLUSIONS: Since apoptosis is the main feature of the cartilage degeneration in OA, the effective inhibition of apoptosis of chondrocytes can provide novel and interesting therapeutic strategies for the treatment of OA. Therefore, BAX and BCL2L12 are highlighted as potential therapeutic targets in OA.

16.
World J Orthop ; 8(2): 163-169, 2017 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-28251067

RESUMO

AIM: To investigate the effectiveness of ultrasound-guided release of the first annular pulley and compare results with the conventional open operative technique. METHODS: In this prospective randomized, single-center, clinical study, 32 patients with trigger finger or trigger thumb, grade II-IV according to Green classification system, were recruited. Two groups were formed; Group A (16 patients) was treated with an ultrasound-guided percutaneous release of the affected A1 pulley under local anesthesia. Group B (16 patients) underwent an open surgical release of the A1 pulley, through a 10-15 mm incision. Patients were assessed pre- and postoperatively (follow-up: 2, 4 and 12 wk) by physicians blinded to the procedures. Treatment of triggering (primary variable of interest) was expressed as the "success rate" per digit. The time for taking postoperative pain killers, range of motion recovery, QuickDASH test scores (Greek version), return to normal activities (including work), complications and cosmetic results were assessed. RESULTS: The success rate in group A was 93.75% (15/16) and in group B 100% (16/16). Mean times in group A patients were 3.5 d for taking pain killers, 4.1 d for returning to normal activities, and 7.2 and 3.9 d for complete extension and flexion recovery, respectively. Mean QuickDASH scores in group A were 45.5 preoperatively and, 7.5, 0.5 and 0 after 2, 4, and 12 wk postoperatively. Mean times in group B patients were 2.9 d for taking pain killers, 17.8 d for returning to normal activities, and 5.6 and 3 d for complete extension and flexion recovery. Mean QuickDASH scores in group B were 43.2 preoperatively and, 8.2, 1.3 and 0 after 2, 4, and 12 wk postoperatively. The cosmetic results found excellent or good in 87.5% (14/16) of group A patients, while in 56.25% (9/16) of group B patients were evaluated as fair or poor. CONCLUSION: Treatment of the trigger finger using ultrasonography resulted in fewer absence of work days, and better cosmetic results, in comparison with the open surgery technique. It is a promising method that represents excellent results without major complications, so that it could be possibly be established as a first-line treatment in the trigger finger's disease.

17.
J Long Term Eff Med Implants ; 27(1): 77-83, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29604952

RESUMO

Fractures of modern cementless stems are almost extinct. However, extra small stems used for cases of developmental dysplasia of the hip (DDH) are still at risk for this complication. We review the fracture of a small size 11, custom-made Wagner cone prosthesis in a 70 year old female patient. The patient had a body-mass index (BMI) of 22.2, 7 yrs after undergoing a total hip arthroplasty. The procedure was undertaken to correct extreme high-riding congenital hip dysplasia. She presented with sudden pain due to a non-traumatic fracture of the stem, just below the proximal third region. At revision, it was apparent that the stem had a concrete distal fixation, whereas the proximal part was loose and probably failed due to cantilever bending fatigue, although the patient had small stature and a low BMI. We trephined out the distal portion, and the patient was successfully revised with a cemented DDH Co-Cr stem. It is our belief that care should be taken when choosing extra small, cementless implants with distal fixation. Cemented prostheses may offer a safe alternative in such cases.


Assuntos
Artroplastia de Quadril , Prótese de Quadril/efeitos adversos , Falha de Prótese , Idoso , Índice de Massa Corporal , Feminino , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Humanos , Reoperação
19.
Mol Med Rep ; 12(3): 4514-4521, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26081683

RESUMO

Osteoarthritis (OA) is primarily characterized by articular cartilage degeneration and chondrocyte loss. Although the role of apoptosis in cartilage pathobiology remains to be elucidated, the apoptotic B­cell CLL/lymphoma 2 (BCL2) gene family is considered to be involved in OA. The purpose of the present study was to quantitatively analyze the mRNA expression profiles of the BCL2­associated X protein (BAX) and BCL2 genes in human OA and in normal cartilage. Cartilage tissue samples were obtained from 78 patients undergoing total knee arthroplasty for OA (OA group) and orthopedic interventions for causes other than OA (control group). Total RNA was isolated from the cartilage tissue specimens and reverse transcribed into cDNA. A highly sensitive and specific reverse transcription quantitative polymerase chain reaction assay was developed for quantification of the mRNA levels of BAX and BCL2, using beta­2 microglobulin as an endogenous control for normalization purposes. Gene expression analysis was performed using the comparative Ct (2(­ΔΔCt)) method. The mRNA expression of BAX presented an increasing trend in the OA group compared with the control group, although without statistically significace (P=0.099). By contrast, the expression ratio of BCL2/BAX was found to be significantly decreased (2.76­fold) in the OA group compared with the normal cartilage control group (P=0.022). A notable 4.6­fold overexpression of median mRNA levels of BAX was also observed in patients with stage III OA compared with the control (P=0.034), while the BCL2/BAX ratio was markedly (2.5­fold) decreased (P=0.024). A marked positive correlation was observed between the mRNA levels of BAX and BCL2 in the control group (r(s)=0.728; P<0.001), which was also present in the OA group, although to a lesser degree (r(s)=0.532; P<0.001). These results further implicate apoptosis in the pathogenesis of OA, through molecular mechanisms, which include the aberrant expression of the BCL2 gene family. Further investigation may reveal novel prognostic biomarkers and potential targets for therapeutic interventions in the early stages of OA.


Assuntos
Apoptose/genética , Cartilagem Articular/metabolismo , Osteoartrite do Joelho/genética , Proteínas Proto-Oncogênicas c-bcl-2/genética , RNA Mensageiro/genética , Proteína X Associada a bcl-2/genética , Adulto , Idoso , Artroplastia do Joelho , Cartilagem Articular/patologia , Cartilagem Articular/cirurgia , Estudos de Casos e Controles , Condrócitos/metabolismo , Condrócitos/patologia , Feminino , Regulação da Expressão Gênica , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/metabolismo , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/cirurgia , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo , RNA Mensageiro/metabolismo , Reação em Cadeia da Polimerase em Tempo Real , Índice de Gravidade de Doença , Transdução de Sinais , Proteína X Associada a bcl-2/metabolismo , Microglobulina beta-2/genética , Microglobulina beta-2/metabolismo
20.
J Arthroplasty ; 30(9): 1602-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25937099

RESUMO

We retrospectively reviewed the medical records of 31 patients with periprosthetic hip infections attempting to evaluate the outcome of a two-stage revision protocol characterized by prolonged interim period (mean=9.2 months, range 8-12 months) prior to the final re-implantation. In 3 cases (9.6%) the 1st stage was repeated after a mean period of 12.3 weeks due to relapse of infection. Five spacer dislocations occurred, not affecting the final clinical outcome after reimplantation, as evaluated by the Harris Hip Score. No protrusions or additional acetabular bone loss was noticed. Our proposed protocol is a simple, safe, efficient and reproducible treatment approach that may be successfully utilized predominantly when dealing with multidrug resistant pathogens.


Assuntos
Artroplastia de Quadril/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Reoperação/métodos , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Artroplastia de Quadril/métodos , Doença Crônica , Farmacorresistência Bacteriana Múltipla , Feminino , Infecções por Bactérias Gram-Positivas/tratamento farmacológico , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Teicoplanina/uso terapêutico , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA