Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 205
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38562651

RESUMO

Purpose: The introduction of HER2-targeting antibody drug conjugates (ADCs) offers new treatment options for female breast cancer patients (FBC) expressing low levels of HER2 (HER2 low). No evidence was found that HER2 low describes a new FBC subtype. There is a lack of studies determining the impact of HER2 low in male breast cancer (MBC). In this study, we evaluate the prevalence of HER2 low in primary MBC and correlate the results with patient characteristics. Patients and Methods: In this study, histological specimens were obtained from 120 male patients diagnosed and treated for primary invasive breast cancer from 1995 to 2022 at Breast Cancer Units in Bergisch Gladbach, Chemnitz, and Zwickau, Germany. HER2 immunostaining and in situ hybridization were performed by central pathology and evaluated based on the ASCO/CAP guidelines. The correlation of expression of HER2 low with tumor biological characteristics and patient outcomes was investigated. Results: Out of all cases, four patients (3.3%) showed HER2 positivity (3+), 39 (32.5%) patients were classified as HER2 low, 7 (5.8%) were HER2 2+ (no amplification), 32 (26.7%) were HER2 1+, and 77 (64.2%) were classified as HER2 zero. Out of 77 HER2 zero cases, 47 tumors (61.0%) showed incomplete staining, with <10% of tumor cells classified as HER2 ultralow. No statistical correlation between HER2 low and tumor biological characteristics and patients' survival was found. Conclusion: Our findings show a notable, albeit lower, prevalence of HER2 low expression in primary MBC. However, tumors expressing HER2 low do not show specific tumor biological features to define a new breast cancer subtype in MBC. Our results suggest that a significant number of MBC patients could benefit from ADCs, as shown in FBC. Further studies are required to better understand HER2 low breast cancer, both generally and in MBC.

2.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38385922

RESUMO

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Masculino , Humanos , Idoso , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Sistema de Registros
4.
ESC Heart Fail ; 11(3): 1540-1552, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38224960

RESUMO

AIMS: In pulmonary arterial hypertension (PAH), upfront combination therapy with ERA and PDE5i is associated with a reduction in morbidity and mortality events and improves standard haemodynamics, but data remain limited. Aims of this study were (i) to capture detailed haemodynamic effects of rapid sequential dual combination therapy in patients with newly diagnosed PAH; (ii) to monitor the impact of treatment initiation on clinical variables and patients' risk status, and (iii) to compare the treatment effect in patients with 'classical PAH' and 'PAH with co-morbidities'. METHODS: Fifty patients (median age 57 [42-71] years, 66% female) with newly diagnosed PAH (76% idiopathic) were treated with a PD5i/sGC-S or ERA, followed by addition of the respective other drug class within 4 weeks. All patients underwent repeat right heart catheterization (RHC) during early follow-up. RESULTS: At early repeat RHC (7 ± 2 months), there were substantial reductions in mean pulmonary artery pressure (mPAP: 52.2 ± 13.5 to 39.0 ± 10.6 mmHg; -25.3%), and pulmonary vascular resistance (PVR: 12.1 ± 5.7 to 5.8 ± 3.1 WU; -52.1%), and an increase in cardiac index (2.1 ± 0.4 to 2.7 ± 0.7 mL/min/m2; +32.2%) (all P < 0.05). Haemodynamic improvements correlated with improved clinical parameters including 6-min walking distance (336 ± 315 to 389 ± 120 m), NTproBNP levels (1.712 ± 2.024 to 506 ± 550 ng/L, both P < 0.05) and WHO-FC at 12 months, resulting in improved risk status, and were found in patients with few (n = 37) or multiple cardiovascular co-morbidities (BMI > 30 kg/m2, hypertension, diabetes, coronary artery disease [≥3]; n = 13), albeit baseline PVR in PAH patients with multiple co-morbidities was lower (9.3 ± 4.4 vs. 13.1 ± 5.9 WU) and PVR reduction less pronounced compared with those with few co-morbidities (-42.7% vs. -54.7%). However, comprehensive haemodynamic assessment considering further variables of prognostic relevance such as stroke volume index and pulmonary artery compliance showed similar improvements among the two groups (SVI: +50.0% vs. +49.2%; PAC: 91.7% vs. 100.0%). Finally, the 4-strata risk assessment approach was better able to capture treatment response as compared with other approaches, particularly in patients with co-morbidities. CONCLUSIONS: Rapid sequential combination therapy with PDE5i/sGC-S and ERA substantially ameliorates cardiopulmonary haemodynamics at early follow-up in patients without, and to a lesser extent, with cardiovascular co-morbidities. This occurs in line with improvements of clinical parameters and risk status.


Assuntos
Quimioterapia Combinada , Hemodinâmica , Inibidores da Fosfodiesterase 5 , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Hemodinâmica/fisiologia , Hemodinâmica/efeitos dos fármacos , Idoso , Adulto , Inibidores da Fosfodiesterase 5/administração & dosagem , Inibidores da Fosfodiesterase 5/uso terapêutico , Hipertensão Arterial Pulmonar/tratamento farmacológico , Hipertensão Arterial Pulmonar/fisiopatologia , Hipertensão Arterial Pulmonar/diagnóstico , Seguimentos , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/uso terapêutico , Resistência Vascular , Fatores de Tempo , Antagonistas dos Receptores de Endotelina/administração & dosagem
5.
Clin Res Cardiol ; 113(1): 94-106, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37581720

RESUMO

BACKGROUND: History of cancer is common in patients undergoing transcatheter mitral valve repair (TMVR). OBJECTIVES: Aim was to examine the impact of cancer history on outcomes after TMVR. METHODS: In patients of a monocentric prospective registry of TMVR history of cancer was retrospectively assessed from records. Associations with 6-week functional outcomes and clinical outcomes during a median follow-up period of 594 days were examined. RESULTS: Of 661 patients (mean age 79 years; age-range 37-101 years; 56.1% men), 21.6% had a history of cancer with active disease in 4.1%. Compared with non-cancer patients, cancer patients had a similar procedural success rate (reduction of mitral regurgitation to grade 2 or lower 91.6% vs. 88%; p = 0.517) and similar relevant improvement in 6-min walking distance, NYHA class, Minnesota Living with Heart Failure Questionnaire score and Short Form 36 scores. 1-year survival (83% vs. 82%; p = 0.813) and 1-year survival free of heart failure decompensation (75% vs. 76%; p = 0.871) were comparable between cancer and non-cancer patients. Patients with an active cancer disease showed significantly higher mortality compared with patients having a history of cancer (hazard ratio 2.05 [95% CI 1.11-3.82; p = 0.023]) but similar mortality at landmark analysis of 1 year. CONCLUSION: TMVR can be performed with equal efficacy in patients with and without cancer and symptomatic mitral regurgitation. Cancer patients show comparable clinical outcome and short-term functional improvement as non-cancer patients. However, longterm mortality was increased in patients with active cancer underlining the importance of patient selection within the heart-team evaluation.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Neoplasias , Masculino , Humanos , Idoso , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Feminino , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Valva Mitral/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
6.
Clin Res Cardiol ; 113(1): 126-137, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37642720

RESUMO

BACKGROUND: Transcatheter repair emerges as a treatment option in patients with tricuspid regurgitation (TR) and high surgical risk. AIMS: This study aimed to compare leaflet-based and annuloplasty-based transcatheter repair in patients with TR. METHODS: In a retrospective analysis consecutive patients undergoing either transcatheter edge-to-edge repair (TEER) or direct annuloplasty (AP) for relevant TR at 2 centers were compared with respect to baseline characteristics, procedural efficacy and safety (death, myocardial infarction, procedure or device-related cardiothoracic surgery, or stroke at 30 days). RESULTS: 161 patients (57% female, median age 79 [75-82] years) with comparable clinical baseline characteristics in the TEER (n = 87) and AP (n = 74) group were examined. Baseline TR grade was significantly less severe in the TEER compared to the AP group (torrential 9.2 vs. 31.1%, p = 0.001). Technical success and improvement of TR grades were not significantly different across groups. In analysis matched for baseline TR severity, reduction of TR grade to less than moderate was significantly more common in the AP group (47.8 vs. 26.1%, p = 0.031). Major or more severe bleeding occurred in 9.2% of TEER and 20.3% of AP patients (p = 0.049) without any fatal bleedings. Major adverse events (MAE) were similar across groups with four patients (4.7%) in the TEER group and five patients (6.9%) in the AP group (p = 0.733) and 6-month survival did not differ significantly. CONCLUSIONS: Differences observed between patients treated with TEER and AP provide first evidence for tailoring distinct transcatheter treatment techniques to individual patient characteristics.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Tricúspide/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos
7.
J Endovasc Ther ; : 15266028231204291, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37853703

RESUMO

PURPOSE: Access-related vascular complications in transfemoral transcatheter aortic valve implantation (TAVI) can be treated endovascularly or surgically. The aim of this study was to evaluate the short- and long-term outcomes of endovascular treatment compared with surgical repair for access-related vascular complications. METHODS: This retrospective study was performed from January 1, 2018, to December 31, 2020. All transfemorally treated TAVI patients in whom a surgical or endovascular treatment for an access site complication was needed were included. The primary outcome was the need for any related vascular re-operation. RESULTS: In total, 1219 transfemoral TAVI procedures were conducted during the study period. 19 patients suffered an access complication requiring endovascular treatment, while 54 patients required surgical repair. No differences were seen with regard to re-operations (endovascular 15.8% vs surgical 14.8%; p=0.919), wound infections (endovascular 0% vs surgical. 11.1%; p=0.129), and wound healing disorders (endovascular 15.8% vs surgical 29.6%; p=0.237). Patients undergoing endovascular treatment were discharged earlier (endovascular 11.2 vs surgical 14.9 days; p=0.028). After surgical repair, patients received significantly more blood transfusions than endovascularly treated patients (endovascular 1.00 vs surgical 3.1 red blood cell concentrate bags; p<0.001). No differences were found regarding the new onset of walking pain, rest pain, and ischemic ulcers during follow-up. CONCLUSION: In this retrospective cohort, endovascular treatment of access-related vascular complications of transfemoral TAVI procedures was safe and feasible. During the hospital stay, endovascularly treated patients received fewer blood transfusions and were discharged faster than surgically treated patients. No differences regarding clinical outcomes and re-intervention rates were seen during the follow-up. CLINICAL IMPACT: Given the in this retrospective study demonstrated safety and feasibility of endovascular treatment for major access-related vascular complications, along with the in-hospital benefits and absence of follow-up disadvantages compared to surgical treatment, endovascular treatment should be considered in cases of major access-related vascular complications in transfemoral TAVI patients.

8.
Ann Thorac Surg ; 2023 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-37717882

RESUMO

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

9.
Basic Res Cardiol ; 118(1): 36, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37656254

RESUMO

Cardiotoxicity is a major complication of anthracycline therapy that negatively impacts prognosis. Effective pharmacotherapies for prevention of anthracycline-induced cardiomyopathy (AICM) are currently lacking. Increased plasma levels of the neutrophil-derived enzyme myeloperoxidase (MPO) predict occurrence of AICM in humans. We hypothesized that MPO release causally contributes to AICM. Mice intravenously injected with the anthracycline doxorubicin (DOX) exhibited higher neutrophil counts and MPO levels in the circulation and cardiac tissue compared to saline (NaCl)-treated controls. Neutrophil-like HL-60 cells exhibited increased MPO release upon exposition to DOX. DOX induced extensive nitrosative stress in cardiac tissue alongside with increased carbonylation of sarcomeric proteins in wildtype but not in Mpo-/- mice. Accordingly, co-treatment of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) with DOX and MPO aggravated loss of hiPSC-CM-contractility compared to DOX treatment alone. DOX-treated animals exhibited pronounced cardiac apoptosis and inflammation, which was attenuated in MPO-deficient animals. Finally, genetic MPO deficiency and pharmacological MPO inhibition protected mice from the development of AICM. The anticancer efficacy of DOX was unaffected by MPO deficiency. Herein we identify MPO as a critical mediator of AICM. We demonstrate that DOX induces cardiac neutrophil infiltration and release of MPO, which directly impairs cardiac contractility through promoting oxidation of sarcomeric proteins, cardiac inflammation and cardiomyocyte apoptosis. MPO thus emerges as a promising pharmacological target for prevention of AICM.


Assuntos
Cardiomiopatias , Células-Tronco Pluripotentes Induzidas , Peroxidase , Animais , Humanos , Camundongos , Antraciclinas/toxicidade , Cardiomiopatias/induzido quimicamente , Cardiomiopatias/prevenção & controle , Doxorrubicina/toxicidade , Inflamação , Peroxidase/genética
10.
JACC Cardiovasc Interv ; 16(16): 1965-1973, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648344

RESUMO

BACKGROUND: Patients with severe aortic regurgitation (AR) are often not considered for surgery because of increased surgical risk. Because of unique anatomical characteristics among patients with AR, interventional treatment options are limited, and implantation results are inconsistent compared with those among patients with aortic stenosis. OBJECTIVES: The authors describe the initial commercial experience of the first Conformité Européenne-marked transfemoral transcatheter aortic valve replacement system (JenaValve Trilogy [JV]) for the treatment of patients with AR. METHODS: This multicenter registry included 58 consecutive patients from 6 centers across Germany. Transcatheter aortic valve replacement was performed with the JV system for isolated severe and symptomatic AR. Patient characteristics, primary implantation outcomes, and valve performance up to 30 days were analyzed using Valve Academic Research Consortium 3 definitions. RESULTS: The mean patient age was 76.5 ± 9 years, with a mean Society of Thoracic Surgeons score of 4.2% ± 4.3%. Device success was achieved in 98% of patients. The mean gradient was 4.3 ± 1.6 mm Hg, and no moderate or severe paravalvular regurgitation occurred. No conversion to open heart surgery or valve embolization was reported. There were no major vascular complications or bleeding events. The rate of new permanent pacemaker implantation was 19.6%. At 30 days, 92% of the patients were in NYHA functional class I or II, and the 30-day mortality rate was 1.7%. CONCLUSIONS: Treatment of patients with severe symptomatic AR using the transfemoral JV system is safe and effective. Given its favorable hemodynamic performance and low complication rates, this system may offer a new treatment option for patients with AR not suitable for surgery.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
11.
Int J Cardiol ; 390: 131203, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37480997

RESUMO

OBJECTIVE: To compare the measurement of aortic diameters using a novel flow-independent MR-Angiography (3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT)) and transthoracic echocardiography (TTE) in Marfan syndrome (MFS) patients. MATERIAL AND METHODS: This retrospective, single-center analysis included 46 examinations of 32 MFS patients (mean age 37.5 ± 11.3 years, 17 women, no prior aortic surgery) who received TTE and 3D modified REACT (ECG- and respiratory-triggering, Compressed SENSE factor 9 for acceleration of image acquisition) of the thoracic aorta. Aortic diameters (sinus of Valsalva (SV), sinotubular junction (STJ), and ascending aorta (AoA)) were independently measured by two cardiologists in TTE (leading-edge) and two radiologists in modified REACT (inner-edge, using multiplanar reconstruction). Intraclass correlation coefficient, Bland-Altman analyses, and Pearson's correlation (r) were used to assess agreement between observers and methods. RESULTS: Interobserver correlation at the SV, STJ, and AoA were excellent for both, TTE (ICC = 0.95-0.98) and modified REACT (ICC = 0.99-1.00). There was no significant difference between TTE and modified REACT for diameters measured at the SV (39.24 ± 3.24 mm vs. 39.63 ± 3.76 mm; p = 0.26; r = 0.78) and the STJ (35.16 ± 4.47 mm vs. 35.37 ± 4.74 mm; p = 0.552; r = 0.87). AoA diameters determined by TTE were larger than in modified REACT (34.29 ± 5.31 mm vs. 30.65 ± 5.64 mm; p < 0.01; r = 0.74). The mean scan time of modified REACT was 05:06 min ± 02:47 min, depending on the patient's breathing frequency and heart rate. CONCLUSIONS: Both TTE and modified REACT showed a strong correlation for all aortic levels; however, at the AoA, diameters were larger using TTE, mostly due to the limited field of view of the latter with measurements being closer to the aortic valve. Given the excellent interobserver correlation and the strong agreement with TTE, modified REACT represents an attractive method to depict the thoracic aorta in MFS patients.


Assuntos
Aorta Torácica , Síndrome de Marfan , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Aorta Torácica/diagnóstico por imagem , Síndrome de Marfan/diagnóstico por imagem , Estudos Retrospectivos , Ecocardiografia/métodos , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
12.
Hellenic J Cardiol ; 74: 1-7, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37119968

RESUMO

OBJECTIVES: Left ventricular reverse remodeling (LVRR) is associated with improved outcome in patients with heart failure. Factors associated with and predictive of LVRR in patients with low-flow low-gradient aortic stenosis (LFLG AS) after transcatheter aortic valve implantation (TAVI) and its impact on outcome were assessed. METHODS: Pre- and postprocedural left ventricular (LV) function and volume were investigated in 219 patients with LFLG. LVRR was defined as an absolute increase of ≥10% in LV ejection fraction (LVEF) and reduction of ≥15% in LV end-systolic volume (LVESV). The primary endpoint was the combination of all-cause mortality and rehospitalization for heart failure. RESULTS: The mean LVEF was 35.0 ± 10.0%, with a stroke volume index (SVI) of 25.9 ± 6.0 mL/m2 and LVESV of 94.04 ± 46.0 mL. At a median of 5.2 months (interquartile range, 2.7-8.1 months), 77.2% (n = 169) of the patients showed echocardiographic evidence of LVRR. A multivariate model revealed three independent factors for LVRR after TAVI: SVI of <25 mL/m2 (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.08-3.58; p < 0.01), LVEF of <30% (HR, 2.76; 95% CI, 1.53-2.91; p < 0.01), and valvulo-arterial impedance (Zva) of <5 mmHg/mL/m2 (HR, 5.36; 95% CI, 1.80-15.98; p < 0.01). Patients without evidence of LVRR showed a significantly higher incidence of the 1-year combined endpoint (32 [64.0%] vs. 75 [44.4%], p < 0.01). CONCLUSIONS: The majority of patients with LFLG AS show LVRR after TAVI, which is associated with favorable outcomes. An SVI of <25 mL/m2, LVEF of <30%, and Zva < 5mmHg/mL/m2 represent predictors of LVRR.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Função Ventricular Esquerda , Volume Sistólico , Insuficiência Cardíaca/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Remodelação Ventricular , Índice de Gravidade de Doença
13.
Clin Res Cardiol ; 112(9): 1220-1230, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36602599

RESUMO

BACKGROUND: Non-hyperemic pressure ratios (NHPRs) like resting full-cycle ratio (RFR), diastolic pressure ratio during entire diastole (dPR[entire]) and diastolic pressure ratio during wave-free period (dPR[WFP]) are increasingly used to guide revascularization. The effect of NHPRs on mid-term prognosis has not been well established. OBJECTIVE: We investigated the prognostic implications of NHRPs in patients whose revascularization was deferred based on fractional flow reserve (FFR) in a single-centre population. METHODS: NHPRs and FFR were calculated offline from pressure tracings by an independent core laboratory. Follow-up data were acquired through records of hospital visits or telephone interviews. The primary outcome was a vessel-oriented composite outcome (VOCO) (a composite of cardiac death, vessel-related myocardial infarction, and ischemia-driven revascularization) in deferred vessels at 2 years. RESULTS: 316 patients with 377 deferred lesions were analysed. Discordance of NHPRs and FFR was found in 13.0-18.3% of lesions. The correlation coefficient between NHPRs was 0.99 (95% confidence interval 0.99-1.00). At 2 years, VOCO occurred in 19 lesions (5.0%). Estimated glomerular filtration rate < 30 mL/min/1.73 m2 [hazard ratio (HR) 5.7, p = 0.002], previous myocardial infarction (HR 3.3, p = 0.018), diabetes (HR 2.7, p = 0.042), RFR ≤ 0.89 (HR 2.7, p = 0.041) and dPR[WFP] ≤ 0.89 (HR 2.7, p = 0.049) were associated with higher incidence of VOCO at 2 years in the univariable analysis. A non-significant trend was found for dPR[entire] (HR 1.9, p = 0.26). CONCLUSION: A positive RFR or dPR[WFP] were associated with a worse prognosis in deferred lesions, suggesting that the use of NHPRs in addition to FFR may improve risk estimation.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Prognóstico , Pressão Sanguínea , Angiografia Coronária , Cateterismo Cardíaco , Valor Preditivo dos Testes
14.
Hellenic J Cardiol ; 70: 1-9, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36538975

RESUMO

OBJECTIVE: Several supra-annular self-expanding transcatheter systems are commercially available for transcatheter aortic valve implantation (TAVI). Comparative data in large-scale multicenter studies are scant. METHODS: This study included a total of 5175 patients with severe aortic stenosis undergoing TAVI with the ACURATE neo (n = 1095), Evolut R (n = 3365), or Evolut PRO (n = 715) by a transfemoral approach at five high-volume centers. Propensity score matching resulted in 654 triplets. Outcomes are reported according to the Valve Academic Research Consortium-3 (VARC-3) consensus. RESULTS: Moderate or severe paravalvular regurgitation (PVR) occurred significantly more often in the ACURATE neo group (5.2%) than in the Evolut R (1.8%) and Evolut PRO (3.3%) groups (p = 0.003). The rates of major vascular-/access-related complications (4.6%, 3.8%, and 5.0%; p = 0.56), type 3 or 4 bleeding (3.2%, 2.1%, and 4.1%; p = 0.12), and 30-day mortality (2.4%, 2.6%, and 3.7%; p = 0.40) were comparable. The rate of new permanent pacemaker implantation (PPI) was significantly lower in the ACURATE neo group (9.5%, 17.6%, and 16.8%; p < 0.001). Independent predictors for 2-year survival were a Society of Thoracic Surgeons (STS) risk score ≥5%, diabetes mellitus, a glomerular filtration rate <30 ml/min, baseline mean transvalvular gradient ≤ 30 mm Hg, treating center, and relevant PVR. CONCLUSION: In this multicenter study, TAVI with the ACURATE neo, Evolut R, or Evolut PRO was feasible and safe. The rate of relevant PVR was more frequent after the ACURATE neo implantation, with, however, lower rates of PPI. Two-year survival was mainly driven by baseline comorbidities.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Pontuação de Propensão , Desenho de Prótese , Resultado do Tratamento
15.
Thorac Cardiovasc Surg ; 71(8): 620-631, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36549305

RESUMO

BACKGROUND: Coronary artery disease (CAD) is frequently diagnosed in patients with aortic valve stenosis. Treatment options include surgical and interventional approaches. We therefore analyzed short-term outcomes of patients undergoing either coronary artery bypass grafting with simultaneous aortic valve replacement (CABG + AVR) or staged percutaneous coronary intervention and transcatheter aortic valve implantation (PCI + TAVI). METHODS: From all patients treated since 2017, we retrospectively identified 237 patients undergoing TAVI within 6 months after PCI and 241 patients undergoing combined CABG + AVR surgery. Propensity score matching was performed, resulting in 101 matched pairs. RESULTS: Patients in the CABG + AVR group were younger compared with patients in the PCI + TAVI group (71.9 ± 4.9 vs 81.4 ± 3.6 years; p < 0.001). The overall mortality at 30 days before matching was higher after CABG + AVR than after PCI + TAVI (7.8 vs 2.1%; p = 0.012). The paired cohort was balanced for both groups regarding demographic variables and the risk profile (age: 77.2 ± 3.7 vs78.5 ± 2.7 years; p = 0.141) and EuroSCORE II (6.2 vs 7.6%; p = 0.297). At 30 days, mortality was 4.9% in the CABG + AVR group and 1.0% in the PCI + TAVI group (p = 0.099). Rethoracotomy was necessary in 7.9% in the CABG + AVR, while conversion to open heart surgery was necessary in 2% in the PCI + TAVI group. The need for new pacemaker was lower after CABG + AVR than after PCI + TAVI (4.1 vs 6.9%; p = 0.010). No paravalvular leak (PVL) was noted in the CABG + AVR group, while the incidence of moderate-to-severe PVL after PCI + TAVI was 4.9% (p = 0.027). CONCLUSION: A staged interventional approach comprises a short-term survival advantage compared with combined surgery for management of CAD and aortic stenosis. However, PCI + TAVI show a significantly higher risk of atrioventricular block and PVL. Further long-term trials are warranted.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco
16.
Thorac Cardiovasc Surg ; 71(2): 101-106, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35853463

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become an established alternative to surgical aortic valve replacement (AVR) for higher risk patients. Periprocedural TAVR complications decreased with a growing expertise of implanters. Yet, TAVR can be accompanied by life-threatening adverse events such as intraprocedural cardiopulmonary resuscitation (CPR). This study retrospectively analyzed predictors and outcomes in a cohort of patients from a high-volume center undergoing periprocedural CPR during TAVR. METHODS: A total of 729 patients undergoing TAVR, including 59 with intraprocedural CPR, were analyzed with respect to peri- and postprocedural outcomes. RESULTS: Patients undergoing CPR showed a significantly lower left ventricular ejection fraction (LVEF) and lower baseline transvalvular mean and peak pressure gradients. The systolic blood pressure measured directly preoperatively was significantly lower in the CPR cohort. CPR patients were in a higher need for intraprocedural defibrillation, heart-lung circulatory support, and conversion to open heart surgery. Further, they showed a higher incidence of atrioventricular block grade III , valve malpositioning, and pericardial tamponade. The in-hospital mortality was significantly higher after intraprocedural CPR, accompanied by a higher incidence of disabling stroke, new pacemaker implantation, more red blood cell transfusion, and longer stay in intensive care unit. CONCLUSION: Impaired preoperative LVEF and instable hemodynamics before valve deployment are independent risk factors for CPR and are associated with compromised outcomes. Heart rhythm disturbances, malpositioning of the prosthesis, and pericardial tamponade are main causes of the high mortality of 17% reported in the CPR group. Nevertheless, mechanical circulatory support and conversion to open heart surgery reduce mortality rates of CPR patients.


Assuntos
Estenose da Valva Aórtica , Tamponamento Cardíaco , Reanimação Cardiopulmonar , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Estudos Retrospectivos , Tamponamento Cardíaco/complicações , Tamponamento Cardíaco/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Risco , Reanimação Cardiopulmonar/efeitos adversos
17.
Z Gastroenterol ; 61(2): 151-154, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35533687

RESUMO

In Germany, colonoscopy was introduced as a screening instrument about 20 years ago. Ten years after an adenoma-negative index endoscopy, a second screening colonoscopy can be performed in younger persons, but this approach is based on limited evidence. We therefore prospectively analyzed the diagnostic yield of second screening colonoscopies in clinical routine.Ten years following adenoma-negative screening endoscopy a second screening colonoscopy was performed in 401 persons (210 women and 191 men); mean age was 70 years. A total of 244 benign neoplastic lesions were removed in 135 persons (34%). Eight persons had three or more small tubular adenomas removed; 19 persons had at least one tubular adenoma measuring ≥ 10 mm; 14 persons had adenomas with villous characteristics; 19 persons had serrated adenomas; one person had an adenoma with high grade dysplasia. Thus 61 persons (33 men and 28 women) were classified as bearing a significant risk for the development of colorectal cancer (15%). An additional patient had a low-risk malignant polyp removed endoscopically.We conclude that a significant number of small and advanced adenomas can be identified in a second screening colonoscopy ten years after an adenoma-negative index screening endoscopy, but malignant lesions are rare. Whether or not removal of the benign lesions in a second screening colonoscopy will reduce incidence and mortality of colorectal carcinoma remains to be seen in this elderly group.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Masculino , Humanos , Feminino , Idoso , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia , Colonoscopia , Pólipos do Colo/epidemiologia , Programas de Rastreamento , Adenoma/diagnóstico por imagem , Adenoma/epidemiologia
18.
Clin Res Cardiol ; 112(5): 571-584, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36107228

RESUMO

BACKGROUND: Transcatheter mitral valve implantation (TMVI) with self-expanding (SAV) or balloon-expandable (BAV) valves are rising as promising treatment options for high-risk patients with symptomatic mitral valve (MVD) disease unsuitable for alternative treatment options. AIMS: The aim of this study was to examine the clinical, procedural and outcome parameters of patients undergoing SAV or BAV for MVD. METHODS: In this observational and single-center case series, fifteen consecutive patients treated with the Tendyne Mitral Valve System (SAV) and thirty-one patients treated with SAPIEN prosthesis (BAV) were included. RESULTS: The patients (aged 78 years [interquartile range (IQR): 65.5 to 83.1 years], 41% women, EuroSCORE II 10.3% [IQR: 5.5 to 17.0%] were similar regarding baseline characteristics, despite a higher rate of prior heart valve surgery and prevalence of MV stenosis in the SAV-group. At discharge, the SAV-group had a mean transvalvular gradient of 4.2 mmHg, whereas the BAV-group had a mean transvalvular gradient of 6.2 mmHg. None or trace paravalvular leakage (PVL) was assessed in 85% in SAV-group and 80% in the BAV-group. 320 day all-cause and cardiac mortality rates were comparable in both groups (SAV: 26.7% vs BAV: 20%, p = 0.60). Four deaths occurred early in the SAV-group until 32 days of follow-up. CONCLUSIONS: In high-risk patients with MVD, TMVI presents a promising treatment option with encouraging mid-term outcomes and good valve durability. TMVI either with BAV or SAV may be developed to an established treatment option.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese
19.
Thorac Cardiovasc Surg ; 71(2): 94-100, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34521136

RESUMO

OBJECTIVE: This study aimed to assess short-term outcomes of patients with failed aortic valve bioprosthesis undergoing valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) or redo surgical aortic valve replacement (rSAVR). METHODS: Between 2009 and 2019, 90 patients who underwent ViV-TAVR (n = 73) or rSAVR (n = 17) due to failed aortic valve bioprosthesis fulfilled the inclusion criteria. Groups were compared regarding clinical end points, including in-hospital all-cause mortality. Patients with endocarditis and in a need of combined cardiac surgery were excluded from the study. RESULTS: ViV-TAVR patients were older (78.0 ± 7.4 vs. 62.1 ± 16.2 years, p = 0.012) and showed a higher prevalence of baseline comorbidities such as atrial fibrillation, diabetes mellitus, hyperlipidemia, and arterial hypertension. In-hospital all-cause mortality was higher for rSAVR than in the ViV-TAVR group (17.6 vs. 0%, p < 0.001), whereas intensive care unit stay was more often complicated by blood transfusions for rSAVR patients without differences in cerebrovascular events. The paravalvular leak was detected in 52.1% ViV-TAVR patients compared with 0% among rSAVR patients (p < 0.001). CONCLUSION: ViV-TAVR can be a safe and feasible alternative treatment option in patients with degenerated aortic valve bioprosthesis. The choice of treatment should include the patient's individual characteristics considering ViV-TAVR as a standard of care.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Risco , Reoperação , Falha de Prótese , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos
20.
Catheter Cardiovasc Interv ; 100(7): 1291-1299, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36378678

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) is independently associated with increased morbidity and mortality. Percutaneous transcatheter approaches may offer an alternative for patients not amenable to surgery. METHODS: TriCLASP is a prospective, single-arm, multicenter European post-market clinical follow-up study (NCT04614402) to evaluate the safety and performance of the PASCAL system (Edwards Lifesciences) in patients with severe or greater TR. At 30 days, a composite of major adverse events (MAEs) adjudicated by a clinical events committee, echocardiographic parameters adjudicated by core laboratory, and clinical, functional, and quality-of-life measures were evaluated. RESULTS: Mean age of the 74 enrolled patients was 80.3 years, with 58.1% female, 90.5% systemic hypertension, and 77.0% in New York Heart Association (NYHA) class III/IV. Mean Society for Thoracic Surgeons score (MV repair) was 9.0%. TR severity was significantly reduced at discharge (p < 0.001) and sustained at 30 days (p < 0.001), and 90.0% of patients achieved ≤moderate TR. The composite MAE rate at 30 days was 3.0%, including 4 events in 2 patients: cardiovascular mortality 1.5%, stroke 1.5%, renal complications requiring unplanned dialysis or renal replacement therapy 1.5%, and severe bleeding 1.5%. There were no nonelective tricuspid valve reinterventions, major access site and vascular complications, major cardiac structural complications, or device embolizations. NYHA class I/II was achieved in 55.8%, 6-minute walk distance improved by 38.2 m (p < 0.001), and Kansas City cardiomyopathy questionnaire scores improved by 13.4 points (p < 0.001). CONCLUSION: Experience with the PASCAL transcatheter valve repair system in a European post-market setting confirms favorable safety and effectiveness at 30 days. TR significantly reduced, and clinical, functional, and quality-of-life outcomes significantly improved. This study is ongoing. Clinical Trial Registration: The study is ongoing and registered on ClinicalTrials.gov as NCT04614402. The current analysis is an interim report.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco , Seguimentos , Estudos Prospectivos , Resultado do Tratamento , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA