Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38531003

RESUMO

BACKGROUND AND OBJECTIVE: Our objective was to assess baseline widefield swept-source optical coherence tomography angiography (WF SSOCTA) microvascular metrics as predictors for the number of anti-vascular endothelial growth factor (VEGF) injections and visual acuity (VA) at 12-months follow-up in patients with retinal vein occlusion (RVO). PATIENTS AND METHODS: This was a prospective study including 49 RVO eyes from 49 patients who had not received an anti-VEGF injection for at least 3 months prior to imaging. Microvascular metrics from 6×6-mm and 12×12-mm angiograms were assessed using linear regression models, adjusting for age. RESULTS: Reductions in the vessel density (VD) and vessel skeletonized density (VSD) vascular metrics were associated both with a higher number of anti-VEGF injections at all follow-up time points and reduced VA 12 months after imaging in all RVO eyes. CONCLUSIONS: WF SS-OCTA VD and VSD micro-vascular metrics at baseline can prognosticate VA and number of anti-VEGF injections required at 3, 6, and 12 months in RVO eyes. [Ophthalmic Surg Lasers Imaging Retina 2024;55:xx-xx.].

2.
Ophthalmic Surg Lasers Imaging Retina ; 55(4): 212-219, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38319059

RESUMO

BACKGROUND AND OBJECTIVE: We sought to establish normative quantitative contrast sensitivity function (qCSF) values in healthy adult eyes and investigate the effect of age on qCSF. PATIENTS AND METHODS: Healthy eyes underwent qCSF testing (adaptive sensory technology) and Snellen's visual acuity (VA). Descriptive statistics and mixed-effects multivariable linear regressions were evaluated. RESULTS: A total of 334 eyes (290 patients) with median age 61 years (range 21 to 88) had qCSF values as follows: area under the log contrast sensitivity function curve: 1.18; contrast acuity: 1.32; contrast sensitivity (CS) at 1 cycle per degree (cpd): 1.32; CS at 1.5 cpd: 1.37; CS at 3 cpd: 1.38; CS at 6 cpd: 1.20; CS at 12 cpd: 0.69; CS at 18 cpd: 0.22. Linear reductions in qCSF values per decade of age ranged from -0.02 to -0.07 vs 0.01 for visual acuity (VA). Age had a greater effect on the majority of qCSF values than VA (beta standardized regression coefficient ranged from -0.309 to -0.141 for qCSF values vs 0.177 for VA). CONCLUSIONS: We herein establish a normative database for qCSF and quantify the effect of age on qCSF values, adding evidence towards the validation of qCSF as a clinical endpoint. [Ophthalmic Surg Lasers Imaging Retina 2024;55:212-219.].


Assuntos
Envelhecimento , Sensibilidades de Contraste , Acuidade Visual , Humanos , Sensibilidades de Contraste/fisiologia , Adulto , Feminino , Masculino , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Idoso , Adulto Jovem , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Voluntários Saudáveis , Valores de Referência , Bases de Dados Factuais
3.
Clin Ophthalmol ; 17: 2539-2552, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37662647

RESUMO

Three-Dimensional (3D) heads-up visualization systems have significantly advanced vitreoretinal surgery, providing enhanced detail and improved ergonomics. This review discusses the application of 3D systems in vitreoretinal surgery, their use in various procedures, their combination with other imaging modalities, and the role of this technology in medical education and telementoring. Furthermore, the review highlights the benefits of 3D systems, such as improved ergonomics, reduced phototoxicity, enhanced depth of field, and the use of color filters. Potential challenges, including the learning curve and additional costs, are also addressed. The review concludes by exploring promising future applications, including teleophthalmology for remote assistance and specialist availability expansion, virtual reality integration for global clinical education, and the combination of remotely robotic-guided surgery with artificial intelligence for precise, efficient surgical procedures. This comprehensive review offers insights into the current state and future potential of 3D heads-up visualization systems in vitreoretinal surgery, underscoring the transformative impact of this technology on ophthalmology.

4.
J Vitreoretin Dis ; 7(2): 97-102, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37006657

RESUMO

Purpose: To evaluate the safety, efficacy, and efficiency of the Ngenuity 3-dimensional (3D) heads-up display (HUD) visualization system for primary rhegmatogenous retinal detachment (RRD) repair at a large academic medical center in the United States. Methods: This retrospective review comprised consecutive patients aged 18 years or older who had primary RRD repair (pars plana vitrectomy [PPV] alone or combined PPV and scleral buckle) performed by the same fellowship-trained vitreoretinal surgeon using the 3D visualization system and a traditional standard operating microscope (SOM) at Massachusetts Eye and Ear from June 2017 to December 2021. The minimum follow-up was 90 days. Results: The 3D HUD group comprised 50 eyes of 47 patients and the SOM group, 138 eyes of 136 patients. There were no between-group differences in single surgery anatomic success rates at 3 months (98% HUD vs 99% SOM; P = 1.00) or at the last follow-up (94% HUD vs 98% SOM; P = .40). The rate of postoperative proliferative vitreoretinopathy was similar between the 2 groups (3 months: 3% HUD vs 5% SOM, P = .94; last follow-up, 2% HUD vs 3% SOM, P = .93). There was no difference in the mean duration of surgery (57.4 ± 28.9 minutes HUD vs 59.4 ± 29.9 minutes SOM; P = .68). Conclusions: Anatomic and functional outcomes, in addition to surgical efficiency, of noncomplex primary RRD repair with a 3D HUD system were similar to those of surgery performed with an SOM.

5.
J AAPOS ; 27(1): 52-55, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36521818

RESUMO

Immune recovery uveitis (IRU) is an ocular form of immune reconstitution inflammatory syndrome, which is rare in the pediatric population. We report a case of IRU in an 11-year-old girl with a history of cytomegalovirus (CMV) retinitis in the setting of acute leukemia, who developed uveitis, vitritis, retinitis, and vasculitis during immune reconstitution. She was found to have negative CMV antigenemia, and the disease occurred during concurrent systemic antiviral therapy. Anterior chamber tap confirmed the absence of the CMV in the eye, and recurrent blood samples continued to reveal absent CMV viral particles systemically while her lymphocyte count was steadily increasing. The patient responded to oral steroids, leading to resolution of active retinitis. Tapering the steroids caused a mild reactivation of the ocular immune response.


Assuntos
Retinite por Citomegalovirus , Leucemia , Uveíte , Feminino , Humanos , Criança , Retinite por Citomegalovirus/tratamento farmacológico , Contagem de Linfócito CD4 , Uveíte/tratamento farmacológico , Antivirais/uso terapêutico , Corpo Vítreo , Leucemia/complicações , Leucemia/tratamento farmacológico
6.
Clin Ophthalmol ; 16: 3079-3088, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36160731

RESUMO

Purpose: The guarded light pipe is a recently described alternative endoillumination technique to chandelier illumination. We sought to compare the outcomes of scleral buckling (SB) under indirect ophthalmoscopy (ID) to heads-up three-dimensional visualization with a guarded light pipe (3DGLP). Methods: A retrospective comparative study was performed, including 47 eyes that underwent SB for rhegmatogenous retinal detachment (RRD) repair with either traditional ID (n = 31) or 3DGLP (n = 16). Results: The single surgery anatomic success rate was 87.0% in the ID group and 87.5% in the 3DGLP group. The final anatomic success rate was 100% in both groups. The median (interquartile range) post-operative logMAR was 0.10 (0.0-0.20) in the ID group and 0.08 (0.02-0.69) in the 3DGLP group (p = 0.51). The median operative time was 107 (94-123) minutes in the ID group and 100 (90-111) minutes in the 3DGLP group (p = 0.25). Among eyes that underwent subretinal fluid drainage, the operative time was significantly longer in the ID group compared to the 3DGLP group, 113 (100-135) minutes vs 93 (85-111) minutes (p = 0.035). There were no post-operative complications in the ID group and one complication of self-resolving vitreous hemorrhage associated with a malfunctioning cryoprobe in the 3DGLP group (p = 0.34). There were no cases of post-operative cataract progression in either group. Conclusion: Compared to traditional SB, 3DGLP improves ergonomics and educational value with similar anatomical, visual, intra and post-operative outcomes and may result in shorter operative time in cases requiring subretinal fluid drainage.

7.
Lasers Surg Med ; 54(7): 935-944, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35708124

RESUMO

BACKGROUND/OBJECTIVES: Optical coherence tomography (OCT) uses low coherence interferometry to obtain depth-resolved tissue reflectivity profiles (M-mode) and transverse beam scanning to create images of two-dimensional tissue morphology (B-mode). Endoscopic OCT imaging probes typically employ proximal or distal mechanical beam scanning mechanisms that increase cost, complexity, and size. Here, we demonstrate in the gastrointestinal (GI) tracts of unsedated human patients, that a passive, single-fiber probe can be used to guide device placement, conduct device-tissue physical contact sensing, and obtain two-dimensional OCT images via M-to-B-mode conversion. MATERIALS AND METHODS: We designed and developed ultrasmall, manually scannable, side- and forward-viewing single fiber-optic probes that can capture M-mode OCT data. Side-viewing M-mode OCT probes were incorporated into brush biopsy devices designed to harvest the microbiome and forward-viewing M-mode OCT probes were integrated into devices that measure intestinal potential difference (IPD). The M-mode OCT probe-coupled devices were utilized in the GI tract in six unsedated patients in vivo. M-mode data were converted into B-mode images using an M-to-B-mode conversion algorithm. The effectiveness of physical contact sensing by the M-mode OCT probes was assessed by comparing the variances of the IPD values when the probe was in physical contact with the tissue versus when it was not. The capacity of forward- and side-viewing M-mode OCT probes to produce high-quality B-mode images was compared by computing the percentages of the M-to-B-mode images that showed close contact between the probe and the luminal surface. Passively scanned M-to-B-mode images were qualitatively compared to B-mode images obtained by mechanical scanning OCT tethered capsule endomicroscopy (TCE) imaging devices. RESULTS: The incorporation of M-mode OCT probes in these nonendoscopic GI devices safely and effectively enabled M-mode OCT imaging, facilitating real-time device placement guidance and contact sensing in vivo. Results showed that M-mode OCT contact sensing improved the variance of IPD measurements threefold and side-viewing probes increased M-to-B-mode image visibility by 10%. Images of the esophagus, stomach, and duodenum generated by the passively scanned probes and M-to-B-mode conversion were qualitatively superior to B-mode images obtained by mechanically scanning OCT TCE devices. CONCLUSION: These results show that passive, single optical fiber OCT probes can be effectively utilized for nonendoscopic device placement guidance, device contact sensing, and two-dimensional morphologic imaging in the human GI tract in vivo. Due to their small size, lower cost, and reduced complexity, these M-mode OCT probes may provide an easier avenue for the incorporation of OCT functionality into endoscopic/nonendoscopic devices.


Assuntos
Tecnologia de Fibra Óptica , Tomografia de Coerência Óptica , Biópsia , Endoscópios , Endoscopia , Humanos
8.
Clin Gastroenterol Hepatol ; 20(4): 756-765.e3, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33549871

RESUMO

BACKGROUND & AIMS: Tethered capsule endomicroscopy (TCE) involves swallowing a small tethered pill that implements optical coherence tomography (OCT) imaging, procuring high resolution images of the whole esophagus. Here, we demonstrate and evaluate the feasibility and safety of TCE and a portable OCT imaging system in patients with Barrett's esophagus (BE) in a multi-center (5-site) clinical study. METHODS: Untreated patients with BE as per endoscopic biopsy diagnosis were eligible to participate in the study. TCE procedures were performed in unsedated patients by either doctors or nurses. After the capsule was swallowed, the device continuously obtained 10-µm-resolution cross-sectional images as it traversed the esophagus. Following imaging, the device was withdrawn through mouth, and disinfected for subsequent reuse. BE lengths were compared to endoscopy findings when available. OCT-TCE images were compared to volumetric laser endomicroscopy (VLE) images from a patient who had undergone VLE on the same day as TCE. RESULTS: 147 patients with BE were enrolled across all sites. 116 swallowed the capsule (79%), 95/114 (83.3%) men and 21/33 (63.6%) women (P = .01). High-quality OCT images were obtained in 104/111 swallowers (93.7%) who completed the procedure. The average imaging duration was 5.55 ± 1.92 minutes. The mean length of esophagus imaged per patient was 21.69 ± 5.90 cm. A blinded comparison of maximum extent of BE measured by OCT-TCE and EGD showed a strong correlation (r = 0.77-0.79). OCT-TCE images were of similar quality to those obtained by OCT-VLE. CONCLUSIONS: The capabilities of TCE to be used across multiple sites, be administered to unsedated patients by either physicians or nurses who are not expert in OCT-TCE, and to rapidly and safely evaluate the microscopic structure of the esophagus make it an emerging tool for screening and surveillance of BE patients. Clinical trial registry website and trial number: NCT02994693 and NCT03459339.


Assuntos
Esôfago de Barrett , Neoplasias Esofágicas , Esôfago de Barrett/diagnóstico por imagem , Esôfago de Barrett/patologia , Biópsia , Neoplasias Esofágicas/patologia , Esofagoscopia/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia de Coerência Óptica/métodos
9.
J Card Surg ; 34(5): 318-322, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30900354

RESUMO

BACKGROUND: The fate of the spared bicuspid aortic valve in patients undergoing ascending aortic aneurysm surgery is relatively unknown. Our institutional policy has been to replace all aortic valves with significant abnormalities, as evidenced by intraoperative transesophageal echocardiography or direct visual inspection. In this study, we elaborate our experience regarding the long-term fate of preserved bicuspid aortic valves after ascending aortic aneurysm extirpation. MATERIALS AND METHODS: From 2000 to 2018, 407 consecutive ascending aortic aneurysm patients with concomitant bicuspid aortic valves underwent surgery by a single surgeon at our institution. Among these, 23 (5.65%) patients did not have their valve replaced, forming the study group. Postoperative and preoperative echocardiograms were compared to determine changes in valve function. RESULTS: Follow-up was complete in 100% of patients. The average time between preoperative and postoperative echocardiograms was 4.50 ± 4.09 years (0.19-15.63). Aortic stenosis or regurgitation changed from none to mild in 5 (21.7%) of patients, with an average echocardiographic interval follow-up of 3.08 years, and from none to severe in 2 (8.7%), with an interval of 11.7 years. One patient required reoperation, including aortic valve replacement, during follow-up. CONCLUSION: Bicuspid aortic valves free of aortic stenosis or insufficiency before surgery and "healthy" appearing at surgery can safely be preserved.


Assuntos
Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas , Tratamentos com Preservação do Órgão/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Valva Aórtica/fisiologia , Doença da Válvula Aórtica Bicúspide , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA