Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Gastrointestin Liver Dis ; 32(4): 433-437, 2023 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-38147598

RESUMO

BACKGROUND AND AIMS: International guidelines advise improving esophagogastroduodenoscopy (EGD) quality in Western countries, where gastric cancer is still diagnosed in advanced stages. This nationwide study investigated some indicators for the quality of EGD performed in endoscopic centers in Italy. METHODS: Clinical, endoscopic, and procedural data of consecutive EGDs performed in one month in the participating centers were reviewed and collected in a specific database. Some quality indicators before and during endoscopic procedures were evaluated. RESULTS: A total of 3,219 EGDs performed by 172 endoscopists in 28 centers were reviewed. Data found that some relevant information (family history for GI cancer, smoking habit, use of proton pump inhibitors) were not collected before endoscopy in 58.5-80.7% of patients. Pre-endoscopic preparation for gastric cleaning was routinely performed in only 2 (7.1%) centers. Regarding the procedure, sedation was not performed in 17.6% of patients, and virtual chromoendoscopy was frequently (>75%) used in only one (3.6%) center. An adequate sampling of the gastric mucosa (i.e., antral and gastric body specimens) was heterogeneously performed, and it was routinely performed only by 23% of endoscopists, and in 14.3% centers. CONCLUSIONS: Our analysis showed that the quality of EGD performed in clinical practice in Italy deserves to be urgently improved in different aspects.


Assuntos
Neoplasias Gastrointestinais , Neoplasias Gástricas , Humanos , Endoscopia do Sistema Digestório/métodos , Endoscopia Gastrointestinal , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/epidemiologia , Itália
2.
Therap Adv Gastroenterol ; 16: 17562848231208667, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954537

RESUMO

Background: Current guidelines strongly recommend the use of validated classifications to support optical diagnosis of lesions with advanced endoscopic imaging in the lower gastrointestinal tract. However, the optimal strategy in inflammatory bowel disease (IBD) is still a matter of debate. Objectives: To analyze the accuracy of endoscopic classifications or single predictors for in vivo lesion characterization during endoscopic surveillance of IBD with advanced endoscopic imaging. Design: Systematic review. Data sources and methods: Medline and PubMed were used to extract all studies which focused on lesion characterization of neoplastic and non-neoplastic lesions in IBD. The diagnostic accuracy of endoscopic classifications and single endoscopic predictors for lesion characterization were analyzed according to type of patients, lesions, and technology used. When available, the rates of true and false positives or negatives for neoplasia were pooled and the sensitivity (SE), specificity (SP), positive predictive value, and negative predictive value (NPV) were calculated. Results: We included 35 studies (2789 patients; 5925 lesions - 1149 neoplastic). Advanced endoscopic imaging included dye-based chromoendoscopy, virtual chromoendoscopy (VCE), magnification and high-definition endoscopy, confocal laser endomicroscopy (CLE), endocytoscopy, and autofluorescence imaging. The Kudo classification of pit patterns was most frequently used, with pooled SE 83%, SP 83%, and NPV 95%. The endoscopic criteria with the highest accuracy, with minimum SE ⩾ 90%, SP ⩾ 80%, and NPV ⩾ 90% were: the Kudo-IBD classification used with VCE (Fuji Intelligent Color Enhancement and i-SCAN); combined irregular surface and vascular patterns used with narrow band imaging; the Mainz classification used with CLE. Multiple clinical and technical factors were found to influence the accuracy of optical diagnosis in IBD. Conclusion: No single endoscopic factor has yet shown sufficient accuracy for lesion characterization in IBD surveillance. Conventional classifications developed in the non-IBD setting have lower accuracy in IBD. The use of new classifications adapted for IBD (Kudo-IBD), and new technologies based on in vivo microscopic analysis show promise.

3.
J Clin Gastroenterol ; 55(10): e87-e91, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33060438

RESUMO

GOALS: The present survey from the Italian Society of Digestive Endoscopy (SIED-Società Italiana di Endoscopia Digestiva) was aimed at reporting infection control practice and outcomes at Digestive Endoscopy Units in a high-incidence area. BACKGROUND: Lombardy was the Italian region with the highest coronavirus disease-2019 (COVID-19) prevalence, at the end of March 2020 accounting for 20% of all worldwide deaths. Joint Gastro-Intestinal societies released recommendations for Endoscopy Units to reduce the risk of the contagion. However, there are few data from high-prevalence areas on adherence to these recommendations and on their efficacy. METHODS: A survey was designed by the Lombardy section of SIED to analyze (a) changes in activity and organization, (b) adherence to recommendations, (c) rate of health care professionals' (HCP) infection during the COVID-19 outbreak. RESULTS: In total, 35/61 invited centers (57.4%) participated; most modified activities were according to recommendations and had filtering face piece 2/filtering face piece 3 and water-repellent gowns available, but few had negative-pressure rooms or provided telephonic follow-up; 15% of HCPs called in sick and 6% had confirmed COVID-19. There was a trend (P=0.07) toward different confirmed COVID-19 rates among endoscopists (7.9%), nurses (6.6%), intermediate-care technicians (3.4%), and administrative personnel (2.2%). There was no correlation between the rate of sick HCPs and COVID-19 incidence in the provinces and personal protective equipment availability and use, whereas an inverse correlation with hospital volume was found. CONCLUSIONS: Adherence to recommendations was rather good, though a minority were able to follow all recommendations. Confirmed COVID-19 seemed higher among endoscopists and nurses, suggesting that activities in the endoscopy rooms are at considerable viral spread risk.


Assuntos
COVID-19 , Endoscopia Gastrointestinal , Humanos , Controle de Infecções , Itália/epidemiologia , SARS-CoV-2
4.
Am J Case Rep ; 17: 65-9, 2016 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-26847214

RESUMO

BACKGROUND: Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. CASE REPORT: A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. CONCLUSIONS: The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.


Assuntos
Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Migração de Corpo Estranho/cirurgia , Stents/efeitos adversos , Idoso , Colangiopancreatografia Retrógrada Endoscópica , Colestase Intra-Hepática/cirurgia , Humanos , Masculino
5.
Case Rep Gastrointest Med ; 2015: 798746, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26137329

RESUMO

Colonic gallstone ileus in an uncommon mechanical bowel obstruction caused by intraluminal impaction of one or more gallstones. The surgical management of gallstone ileus is complex and is potentially of high risk. There have been reports of gallstone extractions using various endoscopic modalities to relieve the obstruction. In this report we present the technique employed to successfully perform a mechanical lithotripsy and extraction of a large gallstone embedded in a sigmoid colon affected by diverticular stenosis. We passed through the stenosis with a 11.3 mm videoscope with 3.7 mm channel. A large lithotripsy extraction basket was used to catch and break up the stone and fragments were removed using the same basket. The patient was discharged asymptomatic three days after the procedure. Using appropriate devices mechanical lithotripsy is a safe and effective method to treat colonic obstruction and avoid surgery in the setting of gallstone ileus even in case of big stones.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA