Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Trauma Emerg Surg ; 49(2): 825-835, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36416946

RESUMO

PURPOSE: The aim of this study was to determine the impact of age on patient-reported health-related quality of life (HRQoL) and the capacity to show resilience-i.e., the ability to adapt to stressful adverse events-after sustaining a polytrauma. METHODS: A cross-sectional multicenter cohort was conducted between 2013 and 2016 that included surviving polytrauma patients (ISS ≥ 16). HRQoL was obtained by the Short Musculoskeletal Function assessment and EuroQol (SMFA and EQ-5D-5L). The effect of age on HRQoL was tested with linear regression analysis. Next, the individual scores were compared with age- and sex-matched normative data to determine whether they showed resilience. Multivariate binary logistic regression was used to assess the effect of age on reaching the normative threshold of the surveys, correcting for several confounders. RESULTS: A total of 363 patients responded (57%). Overall, patients had a mean EQ-5D-5L score of 0.73. With higher age, scores on the SMFA subscales "upper extremity dysfunction," "lower extremity dysfunction" and "daily activities" significantly dropped. Only 42% of patients were classified as being resilient, based on the EQ-5D-5L score. Patients aged 60-69 showed the highest resilience (56%), and those aged 80 + showed the lowest resilience (0%). CONCLUSION: Sustaining a polytrauma leads to a serious decline in HRQoL. Aging is associated with a decline in the physical components of HRQoL. No clear relationship with age was seen on the non-physical components of quality of life. Octogenarians, and to a lesser extent septuagenarians and tricenarians, showed to be very vulnerable groups, with low rates of resilience after surviving a polytrauma.


Assuntos
Traumatismo Múltiplo , Qualidade de Vida , Idoso de 80 Anos ou mais , Humanos , Estudos Transversais , Inquéritos e Questionários , Modelos Logísticos , Nível de Saúde
2.
Eur J Trauma Emerg Surg ; 48(4): 2849-2857, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35254459

RESUMO

PURPOSE: Pelvic ring injuries are known to affect the patients' daily life in terms of physical functioning and quality of life (QoL). Still, prospective studies on the patient's perception over the first 2 years of rehabilitation are lacking. Therefore, patients cannot be properly informed about whether or when they will return to their pre-existing level of physical functioning and QoL. METHODS: A prospective longitudinal cohort study was performed over a 4-year period including all consecutive patients above 18 years who sustained a pelvic ring injury in a level 1 trauma center. Validated patient-reported outcome measures (PROMs) were used to assess physical functioning (SMFA) and QoL (EQ-5D) at baseline (recalled pre-injury score), 6 weeks, 3 months, 6 months, 1 year and 2 years after the injury. It was assessed whether patients had fully recovered by comparing follow-up scores to baseline PROMs. Binary logistic regression analysis was used to identify independent predictors for patients who did not fully recover. Most experienced difficulties at 3 months and 1 year were identified by analyzing the highest reported scores on individual items of the SMFA. RESULTS: A total of 297 patients with a pelvic ring injury were identified of which 189 were eligible for follow-up and 154 (82%) responded. Median SMFA function score at 3 months, 1 and 2 years was 70, 78 and 88, respectively, compared to 96 out of 100 before the injury. Median SMFA bother score was 67, 79 and 88, respectively. Median EQ-5D score at 3 months, 1 and 2 years was 0.61, 0.81 and 0.85, respectively, compared to 1 (maximum achievable) before the injury. After 1 and 2 years of follow-up, 61% and 75% of the patients fully "recovered" in physical functioning and 52% and 71% fully recovered in terms of QoL. Female gender and high-energy trauma were independent predictors for not fully recovering after 1 year. After 3 months of follow-up, 54% of patients reported severe difficulties with recreational activities, whereas after 1 year, most experienced difficulties (31% of patients) concerned heavy house or yard work. Moreover, after 3 months and 1 year, 44% and 27% of patients reported feeling physically disabled. CONCLUSION: Pelvic ring injuries have a large impact on the patients' daily life in the first 2 years of rehabilitation. Directly after the injury, physical functioning and QoL decrease strongly but then gradually improve over a 2-year period with about 75% of patients fully recovering. Female gender and high-energy trauma are shown to be independent predictors for not fully recovering. After 3 months, patients experience difficulties with both the physical and mental effects of the injury which continue to be present after 1 year.


Assuntos
Ossos Pélvicos , Qualidade de Vida , Feminino , Humanos , Estudos Longitudinais , Saúde Mental , Ossos Pélvicos/lesões , Estudos Prospectivos
3.
J Pers Med ; 11(9)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34575708

RESUMO

Background: There has been an exponential growth in the use of advanced technologies for three-dimensional (3D) virtual pre- and intra-operative planning of pelvic ring injury surgery but potential benefits remain unclear. The purpose of this study was to evaluate differences in intra- and post-operative results between 3D and conventional (2D) surgery. Methods: A systematic review was performed including published studies between 1 January 2010 and 22 May 2020 on all available 3D techniques in pelvic ring injury surgery. Studies were assessed for their methodological quality according to the Modified McMaster Critical Review form. Differences in operation time, blood loss, fluoroscopy time, screw malposition rate, fracture reduction and functional outcome between 3D-assisted and conventional (2D) pelvic injury treatment were evaluated and a best-evidence synthesis was performed. Results: Eighteen studies fulfilled the inclusion criteria, evaluating a total of 988 patients. Overall quality was moderate. Regarding intra-operative results of 3D-assisted versus conventional surgery: The weighted mean operation time per screw was 43 min versus 52 min; for overall operation time 126 min versus 141 min; blood loss 275 ± 197 mL versus 549 ± 404 mL; fluoroscopy time 74 s versus 125 s and fluoroscopy frequency 29 ± 4 versus 63 ± 3. In terms of post-operative outcomes of 3D-assisted versus conventional surgery: weighted mean screw malposition rate was 8% versus 18%; quality of fracture reduction measured by the total excellent/good rate by Matta was 86% versus 82% and Majeed excellent/good rate 88% versus 83%. Conclusion: The 3D-assisted surgery technologies seem to have a positive effect on operation time, blood loss, fluoroscopy dose, time and frequency as well as accuracy of screw placement. No improvement in clinical outcome in terms of fracture reduction and functional outcome has been established so far. Due to a wide range of methodological quality and heterogeneity between the included studies, results should be interpreted with caution.

4.
JAMA Netw Open ; 4(2): e2037519, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33599774

RESUMO

Importance: In acetabular fracture surgery, achieving an optimal reconstruction of the articular surface decreases the risk of osteoarthritis and the subsequent need for total hip arthroplasty. However, no one-size-fits-all osteosynthesis plate is available owing to differences in fracture patterns and variations in pelvic anatomy. Currently, osteosynthesis plates need to be manually contoured intraoperatively, often resulting in inadequate reduction and fixation of the fractured segments. Objective: To determine the feasibility and accuracy of a novel concept of fast-track 3-dimensional (3-D) virtual surgical planning and patient-specific osteosynthesis for complex acetabular fracture surgery. Design, Setting, and Participants: This case series study examines the use of patient-specific osteosynthesis plates for patients needing operative treatment for displaced associated-type acetabular fractures at a tertiary university-affiliated referral center and level 1 trauma center between January 1, 2017, and December 31, 2018. Models were created in 3-D based on computed tomography (CT) data, fractures were virtually reduced, and implant positions were discussed in a multidisciplinary team of clinicians and engineers. Patient-specific osteosynthesis plates with drilling guides were designed, produced, sterilized and clinically applied within 4 days. Data were analyzed at the 1-year follow-up. Exposures: Development and clinical implementation of personalized fracture surgery. Main Outcomes and Measures: The primary outcome was the quality of the reduction as determined by the postoperative CT scan. The secondary outcomes were accuracy of the screw placement and clinical outcome using patient-reported outcome measures. Results: Ten patients with a median (range) age of 63 (46-79) years with an acetabular fracture were included. The median (interquartile range [IQR]) preoperative gap was 20 (15-22) mm, and the median (IQR) step-off was 5 (3-11) mm. Postoperatively, the median (IQR) gap was reduced to 3 (2-5) mm (P = .005), and the median (IQR) step-off was reduced to 0 (0-2) mm (P = .01), indicating good fracture reduction, indicating good fracture reduction. The mean difference between the preoperative and postoperative gap was 14.6 (95% CI, 10-19) mm, and the mean difference in step-off was 5.7 (95% CI, 2-9) mm. The median (IQR) difference in screw direction between the planning and actual surgery was only 7.1° (7°-8°). All patients retained their native hip and reported good physical functioning at follow-up. Conclusions and Relevance: These findings suggest that 3-D virtual surgical planning, manufacturing, and clinical application of patient-specific osteosynthesis plates and drilling guides was feasible and yielded good clinical outcomes. Fast-track personalized surgical treatment could open a new era for the treatment of complex injuries.


Assuntos
Acetábulo/lesões , Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Acetábulo/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Fraturas Ósseas/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Indústria Manufatureira , Pessoa de Meia-Idade , Modelos Anatômicos , Medidas de Resultados Relatados pelo Paciente , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
Clin Orthop Relat Res ; 478(12): 2801-2808, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32769535

RESUMO

BACKGROUND: Gap and stepoff values in the treatment of acetabular fractures are correlated with clinical outcomes. However, the interobserver and intraobserver variability of gap and stepoff measurements for all imaging modalities in the preoperative, intraoperative, and postoperative phase of treatment is unknown. Recently, a standardized CT-based measurement method was introduced, which provided the opportunity to assess the level of variability. QUESTIONS/PURPOSES: (1) In patients with acetabular fractures, what is the interobserver variability in the measurement of the fracture gaps and articular stepoffs determined by each observer to be the maximum one in the weightbearing dome, as measured on pre- and postoperative pelvic radiographs, intraoperative fluoroscopy, and pre- and postoperative CT scans? (2) What is the intraobserver variability in these measurements? METHODS: Sixty patients with a complete subset of pre-, intra- and postoperative high-quality images (CT slices of < 2 mm), representing a variety of fracture types with small and large gaps and/or stepoffs, were included. A total of 196 patients with nonoperative treatment (n = 117), inadequate available imaging (n = 60), skeletal immaturity (n = 16), bilateral fractures (n = 2) or a primary THA (n = 1) were excluded. The maximum gap and stepoff values in the weightbearing dome were digitally measured on pelvic radiographs and CT images by five independent observers. Observers were free to decide which gap and/or stepoff they considered the maximum and then measure these before and after surgery. The observers were two trauma surgeons with more than 5 years of experience in pelvic surgery, two trauma surgeons with less than 5 years of experience in pelvic surgery, and one surgical resident. Additionally, the final intraoperative fluoroscopy images were assessed for the presence of a gap or stepoff in the weightbearing dome. All observers used the same standardized measurement technique and each observer measured the first five patients together with the responsible researcher. For 10 randomly selected patients, all measurements were repeated by all observers, at least 2 weeks after the initial measurements. The intraclass correlation coefficient (ICC) for pelvic radiographs and CT images and the kappa value for intraoperative fluoroscopy measurements were calculated to determine the inter- and intraobserver variability. Interobserver variability was defined as the difference in the measurements between observers. Intraobserver variability was defined as the difference in repeated measurements by the same observer. RESULTS: Preoperatively, the interobserver ICC was 0.4 (gap and stepoff) on radiographs and 0.4 (gap) and 0.3 (stepoff) on CT images. The observers agreed on the indication for surgery in 40% (gap) and 30% (stepoff) on pelvic radiographs. For CT scans the observers agreed in 95% (gap) and 70% (stepoff) of images. Postoperatively, the interobserver ICC was 0.4 (gap) and 0.2 (stepoff) on radiographs. The observers agreed on whether the reduction was acceptable or not in 60% (gap) and 40% (stepoff). On CT images the ICC was 0.3 (gap) and 0.4 (stepoff). The observers agreed on whether the reduction was acceptable in 35% (gap) and 38% (stepoff). The preoperative intraobserver ICC was 0.6 (gap and stepoff) on pelvic radiographs and 0.4 (gap) and 0.6 (stepoff) for CT scans. Postoperatively, the intraobserver ICC was 0.7 (gap) and 0.1 (stepoff) on pelvic radiographs. On CT the intraobserver ICC was 0.5 (gap) and 0.3 (stepoff). There was no agreement between the observers on the presence of a gap or stepoff on intraoperative fluoroscopy images (kappa -0.1 to 0.2). CONCLUSIONS: We found an insufficient interobserver and intraobserver agreement on measuring gaps and stepoffs for supporting clinical decisions in acetabular fracture surgery. If observers cannot agree on the size of the gap and stepoff, it will be challenging to decide when to perform surgery and study the results of acetabular fracture surgery. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Acetábulo/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Acetábulo/lesões , Adulto , Competência Clínica , Feminino , Fluoroscopia , Fraturas do Quadril/cirurgia , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA