Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Minerva Cardioangiol ; 68(5): 453-468, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33155784

RESUMO

BACKGROUND: We aimed to assess the clinical and echocardiographic characteristics of patients who underwent surgery for degenerative mitral valve prolapse (MVP) in our center, and its relation to outcomes. METHODS: We enrolled 117 consecutive patients from North-East China with an echocardiographic diagnosis of MVP related mitral regurgitation (MR) between April 2018 and November 2019. A complexity scoring system was used for valve anatomy, and patients were re-evaluated at 3-6 months after surgery. RESULTS: Most patients (57.3%) were 40-59 years old. Ejection fraction was <60% in one third, and pulmonary hypertension was present in 64.3% of operated patients. Etiology was myxomatous in 58.9%, with flail as main lesion. Leaflet involvement was posterior in 59.8% patients, anterior in 32.5%, bileaflet in 6%, and commissural in 25.6%. Lesion score was intermediate in >50% of patients, and myxomatous lesions scored higher compared to fibroelastic deficiency (FED). Degree of MR left atrial volume and estimated wedge pressure were significantly higher in intermediate and complex lesions. Repair was performed in 93/101 patients (95.8% success rate). No in-hospital major adverse events, nor deaths at follow-up were reported. Residual MR was ≤ mild in 86.7% of patients at follow-up and was associated with FED etiology and complex lesions. CONCLUSIONS: Compared to Western countries, in our sample of Chinese population degenerative severe MR occurred in younger patients. The MVP lesion characteristics are similar, can be accurately detected by non-invasive preoperative evaluation, allowing predictable results. Advanced tailored repair techniques allow excellent immediate and short-term results regardless of the underlying complexity.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Adulto , China , Seguimentos , Humanos , Pessoa de Meia-Idade , Valva Mitral , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico , Prolapso da Valva Mitral/cirurgia , Resultado do Tratamento
3.
Int J Cardiovasc Imaging ; 26(6): 651-60, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20352342

RESUMO

A new generation of transoesophageal echocardiographic probes with a novel matrix array technique has been recently introduced, allowing three-dimensional (3D) presentation of cardiac structures in real-time. This new tool may potentially provide fast and complete 3D information about cardiac structures improving spatial orientation and overcoming limitations of offline 3D technologies. The aim of this study was to demonstrate the feasibility and usefulness of real-time 3D transoesophageal echocardiography (TOE) for the intraoperative evaluation of cardiac surgery procedures. One-hundred patients underwent transoesophageal echocardiographic examination during cardiac surgery as a part of their routine clinical practice. In the intraoperative pre- and post-cardiopulmonary bypass periods complete 2D and 3D transoesophageal examinations were performed. Feasibility and duration of examinations, and immediate additional anatomical value of 3D versus 2D-TOE were annotated intraoperatively. Image quality, additional clinical value of 3D- compared to standard 2D-TOE and the accuracy in the description of mitral valve pathology by a surgeon and an echocardiographer were evaluated off-line. No complications related to transoesophageal examination occurred and successful intubation was achieved in all 100 patients. Therefore, 200 examinations were performed and analysed considering the pre- and post-cardiopulmonary bypass periods. The mean number of acquisitions per patient was 16 +/- 14, including 3D real-time, zoom, full-volume and colour full volume modalities. The duration of the 3D examination was 16 +/- 10 min and the mean image quality score 2.8 +/- 0.7 (in a scale 1-4). In 36 out of 100 cases (36%) 3D-TOE provided additional anatomical information. The surgeon evaluated 3D images easier and more accurately than 2D images (88% vs. 76% in the evaluation of mitral valve scallop). Real-time 3D TOE may be used routinely for the intraoperative evaluation of cardiac surgery. Imaging with this new probe facilitates intraoperative evaluation of several surgical procedures with an additional clinical value in selected cases.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Idoso , Estudos de Viabilidade , Feminino , Humanos , Cuidados Intraoperatórios , Itália , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA