Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
World J Urol ; 42(1): 298, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709327

RESUMO

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Assuntos
Desenho de Equipamento , Rim , Iluminação , Ureteroscópios , Modelos Anatômicos , Humanos
2.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
3.
Urol Int ; 106(4): 404-410, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34134117

RESUMO

INTRODUCTION: The objective of this study was to present our clinical experience of using the thulium fiber laser in retrograde intrarenal surgery (RIRS). METHODS: A prospective clinical study performed after the IRB approval (Sechenov University, Russia). Patients with stones <30 mm were treated with SuperPulsed thulium fiber laser (SP TFL) (NTO IRE-Polus, Russia) through a 200-µm-diameter fiber. Stone size, density, the duration of the operation, and laser on time (LOT) were measured. Based on the surgeon's feedback, retropulsion and intraoperative visibility were also assessed (Likert scale). Stone-free rates (SFRs) were assessed with a low-dose CT scan 90 days after the operation. RESULTS: Between January 2018 and December 2019, 153 patients (mean age 54 ± 2.8 years) underwent RIRS with SP TFL (mean stone density 1,020 ± 382 HU). Median stone volume was 279.6 (139.4-615.8) mm3. Median LOT was 2.8 (IQR 1.6-6.6) min with median total energy for stone ablation 4.0 (IQR 2.1-7.17) kJ, median ablation speed was 1.7 (1.0-2.8) mm3/s, median ablation efficacy was 13.3 (7.3-20.9) J/mm3, and energy consumption was 170.3 (59.7-743.3) J/s. Overall, the SFR (at 3 months) was 89%. The overall complication rate was 8.4%. Retropulsion was present in 23 (15.1%) patients. Visibility was estimated as optimal in most patients, with poor visibility reported in only 13 (8.5%) patients. CONCLUSION: The SP TFL is a safe and efficient tool in lithotripsy, irrespective of the stone type and density. Retropulsion is minimal and visibility is maintained with SP TFL. Nonetheless, further clinical studies are needed to ensure optimal comparison with conventional holmium:YAG lithotripsy.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Lasers , Lasers de Estado Sólido/uso terapêutico , Pessoa de Meia-Idade , Estudos Prospectivos , Túlio
4.
World J Urol ; 39(9): 3197-3205, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33386951

RESUMO

OBJECTIVE: To define which long-term stent would work best in malignant ureteral obstruction (MUO) and benign ureteral obstruction (BUO), focusing on their mechanisms of action, price and insertion approach. METHODS: A systematic review was developed using the MEDLINE and Scopus databases and in accordance with the PRISMA checklist. There were no language restrictions for the search. Studies describing the use of metallic ureteric stents for MUO and for BUO in humans were included. RESULTS: We analyzed five types of metallic stents (35 papers) and also the experience with the tumor and extra-anatomical stents. The Resonance, Memokath and Allium ureteral stents were found to be useful in BUO and MUO. The Uventa stent performed well in chronic ureteral obstruction. The Detour bypass stent was a recommended option in those patients who had complete obstruction of the ureter and were unfit for reconstructive surgery. There was no difference with regard to the insertion technique and both antegrade and retrograde approaches were equally successful. Although tumor stents showed a good performance, there were very few published studies on it. CONCLUSION: Metallic stents are a suitable option for MUO and BUO. When compared to standard double J stents, although they are relatively high priced, they show a financial benefit in the long-term. The Detour bypass stent seems to be an effective alternative for complete ureteral obstruction or patients unfit for surgery. Further prospective randomized studies should be done on the effectiveness of tumor stents versus metallic stents.


Assuntos
Stents , Obstrução Ureteral/cirurgia , Constrição Patológica , Humanos , Desenho de Prótese , Fatores de Tempo
5.
World J Urol ; 39(6): 2169-2175, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33025141

RESUMO

OBJECTIVES: A recently introduced device (LithoVue Empower™ or LE, Boston Scientifics, USA) allows the surgeon to directly control the stone-retrieving basket without the need of an assistant during flexible ureteroscopy. We aimed to evaluate the stone-retrieval performance of this device. METHODS: We used a bench-training model for flexible ureteroscopy, the Key-box (K-Box®, Porgès-Coloplast, France), to compare the LE configured with a 1.9F stone-retrieval tipless basket (ZeroTip™, Boston Scientific, USA) and a traditional assistant-maneuvered 1.9F stone-retrieval tipless basket. Seven experienced endo-urologists and seven residents-in-training retrieved a fake stone from three different renal cavities of the K-Box with increasing access complexity first with the traditional basket and then with the LE device. We recorded retrieval time and all the operators filled in the NASA Task Load Index (TLI) for the self-evaluation of their performance. We then compared the use of LE in terms of retrieval time, failure rates, and NASA-TLI scores. RESULTS: Stone retrieval times and failure rates were similar according to the retrieval technique, although residents had non-statistically significant shorter times with the LE. NASA-TLI scores revealed lower frustration (p = 0.03) when LE was used by experienced urologists as compared to the traditional basketing. When stratifying the analyses according to surgical experience, fully trained urologists performed faster stone retrieval and showed lower effort scores than residents-in-training (p < 0.05). CONCLUSIONS: The individually controlled retrieval system is an effective device assisting stone retrieval and does not necessitate specific training among experienced endo-urologists. Young residents might benefit from LE during their learning curve.


Assuntos
Cálculos Renais/cirurgia , Modelos Anatômicos , Treinamento por Simulação , Ureteroscopia/educação , Ureteroscopia/métodos , Humanos , Ureteroscopia/instrumentação
6.
World J Urol ; 39(7): 2709-2717, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32955661

RESUMO

PURPOSE: To compare intrapelvic pressure (IPP) levels achieved during f-URS, mini-PCNL, standard PCNL, and endoscopic combined intrarenal surgery in a kidney model. METHODS: A silicone model simulating the complete urinary tract was used for all the experiments. We compared: a 9.5Fr f-URS, a 12Fr mini-nephroscope and a 26Fr nephroscope. The irrigation pressure was set at 40 and 193 cmH2O. We compared: f-URS-S ± ureteral access sheath (UAS, 10/12Fr, 11/13Fr, 12/14Fr) ± 273 µm laser fiber, Mini-PCNL with different sizes of operating sheath (15/16Fr, 16.5/17.5Fr, 21/22Fr) ± 365 µm laser fiber, Standard PCNL with an operating sheath of 30Fr ± Lithotripter LithoClast Master 11.4Fr. RESULTS: f-URS: IPP values ranged between 1.4 and 46.2 cmH2O. Factors reducing IPP were an irrigation pressure at 40 cmH2O, an occupied working channel, and the use of a UAS except with the 10/12Fr at 193 cmH2O. Mini-PCNL: IPP values ranged between 2.4 and 39.7 cmH2O. Factors reducing IPP were irrigation pressure at 40 cmH2O, a large operating sheath (> 15/16Fr). The occupation of the working channel did not affect the IPP at 40 cmH2O, while it decreased at 193 cmH2O. Standard PCNL: IPP values ranged between 1.4 and 7.3 cmH2O. Occupancy of the working channel did not affect IPP at 40 cmH2O, while it increased at 193 cmH2O. CONCLUSION: We recorded for the first time IPP values according to different endourological techniques and configurations. IPP never exceed 50 cmH2O irrespectively of the assessed technique/setup. The factors reducing IPP were a low irrigation pressure (40 cmH2O), the use of a UAS or a working sheath appropriate to the diameter of the endoscope, as well as the occupation of the working channel in the case of f-URS.


Assuntos
Endoscopia , Rim , Modelos Anatômicos , Nefrolitotomia Percutânea/métodos , Ureteroscopia , Humanos , Masculino , Pelve , Pressão , Ureteroscópios
7.
J Endourol ; 35(1): 71-76, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32668988

RESUMO

Introduction: To assess long-term outcomes of double internal stents (DIS) for the relief of external malignant ureteral obstruction (MUO). Materials and Methods: DIS (7F each; 12-month indwelling time) were inserted under general anesthesia in 62 consecutive patients (75 renal units) with MUO during 2007-2018. Surveillance was performed every 3 months, and stents were exchanged routinely every year. The need for permanent stent retrieval was considered stent failure. Maintenance of stent patency and disease-specific survival (DSS) were estimated (Kaplan-Meier). Risk factors were also assessed (univariate and multivariable Cox regression analyses). Results: The median follow-up was 27 months (interquartile range [IQR] 20-27). The most frequent tumors causing obstruction were colorectal and ovarian cancers. Six patients (10%) had stent failure caused by sepsis, creatinine elevation, or hematuria. The average time to failure was 15 months (range 1-27). A history of radiation and an estimated glomerular filtration rate (eGFR) ≤45 mL/(min/1.73 m2) were associated with stent failure (p = 0.038 and p = 0.001, respectively). Thirty-nine patients died with a median DSS of 21 months (IQR 8.6-not reached). Multivariate analysis identified eGFR ≤60 mL/(min/1.73 m2) (hazard ratio [HR] 2.1, 95% confidence interval [CI] 1.1-4.2, p = 0.02) and need for balloon dilation (HR 2.1, 95% CI 1.1-4.1, p = 0.02) as independent predictors for disease-related mortality. Twenty-six patients (42%) had stent-related complications, for example, irritative symptoms, hematuria, and infections, of whom only two failed. Conclusions: One-year indwelling DIS provide effective long-term relief of MUO and represent a simple and effective alternative to other methods of urinary diversion. They avoid the need for external tubes and contribute to improved patient satisfaction.


Assuntos
Ureter , Obstrução Ureteral , Seguimentos , Humanos , Estudos Retrospectivos , Stents , Obstrução Ureteral/etiologia , Obstrução Ureteral/cirurgia
8.
J Endourol ; 35(3): 241-248, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32762266

RESUMO

Objective: To compare whether the outcomes of ultrasound-guided access percutaneous nephrolithotomy (USGA-PCNL) are similar to standard fluoroscopy-guided access percutaneous nephrolithotomy (FGA-PCNL). Methods: A review was developed by using the MEDLINE and Scopus databases and following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses protocol. Studies comparing the USGA-PCNL and the FGA-PCNL were included. Case reports, editorials and letters, unpublished studies, posters, and comments abstracts were excluded. Results: We found 12 published articles that compared USGA-PCNL and FGA-PCNL. These included six randomized controlled trials, three case-control trials, and three meta-analyses. The overall results showed no difference in the success of percutaneous access, bleeding, blood transfusion, operative time, postoperative complications, or hospital stay. Conclusion: The reported data demonstrate that there are no significant differences between the fluoroscopic-guided access PCNL and the ultrasonographic access PCNL. The choice of puncture depends on the surgeon's expertise in a particular technique and the patient and stone characteristics. Both approaches are equally safe and effective in experienced hands. It is important to recall that the use of one technique does not exclude the use of the other, and they can sometimes be complementary to each other.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Fluoroscopia , Humanos , Cálculos Renais/cirurgia , Duração da Cirurgia , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA