1.
JACC Cardiovasc Interv ; 17(5): 622-631, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479964

RESUMO

BACKGROUND: National quality reporting efforts after revascularization for peripheral artery disease (PAD) are ongoing. Validation of endpoints are necessary in national quality registries. OBJECTIVES: This study sought to examine the interrater reliability for the endpoint of major amputation at 1 year in the Vascular Quality Initiative (VQI) registry and the Medicare-linked Vascular Quality Initiative registry (VQI-VISION) against electronic health record (EHR) review. METHODS: Surgical or endovascular revascularization procedures between January 1, 2010, and December 31, 2017, in the VQI registry and VQI-VISION for 2 academic health systems were queried. Major amputation data were abstracted by trained data collectors for the VQI and derived from Current Procedural Terminology codes for VQI-VISION. Cases underwent protocolized adjudication for the endpoint of major amputation by EHR review. Paired tests were used to evaluate the sensitivity and specificity. Spearman's ρ and Cohen's κ were used to evaluate interrater reliability. RESULTS: Amputation endpoints for 1,936 revascularizations were examined. Compared with major amputation data in EHR review, the sensitivity for the VQI registry was 35.9% and the specificity was 99.4% (ρ = 0.53; κ = 0.48). For VQI-VISION, sensitivity was 67.7% and specificity was 98.9% (ρ = 0.75; κ = 0.74). For any amputation in VQI data, sensitivity was 35.3% and specificity was 99.3% (ρ = 0.53; κ = 0.46), and for VQI-VISION, they were 71.6% and 97.7%, respectively (ρ = 0.75; κ = 0.74). CONCLUSIONS: Almost two-thirds of the amputations in the VQI registry and one-third of amputations in VQI-VISION were missing at 1 year compared against adjudicated EHR review. In preparing for national reporting systems for major amputation tracking, data collection system reform is needed.


Assuntos
Procedimentos Endovasculares , Doença Arterial Periférica , Idoso , Humanos , Estados Unidos , Resultado do Tratamento , Reprodutibilidade dos Testes , Fatores de Risco , Complicações Pós-Operatórias/cirurgia , Medicare , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/cirurgia , Amputação Cirúrgica , Estudos Retrospectivos
3.
J Cardiothorac Vasc Anesth ; 36(7): 2090-2097, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34275733

RESUMO

The use of intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) has grown exponentially in recent years. Three-dimensional TEE technology has evolved to allow for real-time display of 3D images and, thus, has become the standard of care for the evaluation of cardiac anatomy and function. Its use has provided a new dimension of clinical insight when managing patients for cardiac surgery or structural heart interventions. While the intraoperative utility of 3D TEE has expanded, there has been a slower advancement in the area of training and, specifically, simulator-based training in 3D TEE. This training is essential, as the skill set involved in acquiring 3D data sets differs from that of two-dimensional (2D) TEE and requires users to be able to appreciate how 3D anatomic display differs from that of tomographic cross-sectional 2D imaging. This added skill set requires mental reconstruction and spatial reorientation to appreciate the added elevational dimension in frustum-based imaging and is best achieved in a simulation environment rather than the busy operating room. In this review article, the authors evaluate the functionality of a 3D TEE simulator and how simulators such as this can establish preclinical proficiency in novices in the expanding area of advanced 3D TEE imaging.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Tridimensional , Estudos Transversais , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Humanos
4.
Eur J Vasc Endovasc Surg ; 62(3): 476-484, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34303598

RESUMO

OBJECTIVE: Primary and secondary lower extremity amputation, performed for patients with lower extremity arterial disease, is associated with increased post-operative morbidity. The aim of the study was to assess the impact of regional anaesthesia vs. general anaesthesia on post-operative pulmonary complications. METHODS: A retrospective analysis of 45 492 patients undergoing lower extremity amputation between 2005 and 2018 was conducted using data from the American College of Surgeons National Safety Quality Improvement Program database. Multivariable logistic regression was carried out to assess differences in primary outcome of post-operative pulmonary complications (pneumonia or respiratory failure requiring re-intubation) within 48 hours and 30 days after surgery between patients receiving regional (RA) or general anaesthesia (GA). Secondary outcomes included post-operative blood transfusion, septic shock, re-operation, and post-operative death within 30 days. RESULTS: Of 45 492 patients, 40 026 (88.0%) received GA and 5 466 (12.0%) RA. Patients who received GA had higher odds of developing pulmonary complications at 48 hours (2.1% vs. 1.4%; adjusted odds ratio [aOR] 1.39, 95% confidence interval [CI] 1.09 - 1.78; p = .007) and within 30 days (6.3% vs. 5.9%; aOR 1.15, 95% CI 1.09 - 1.78; p = .039). The odds of blood transfusions (aOR 1.11, 95% CI 1.02 - 1.21; p = .017), septic shock (aOR 1.29, 95% CI 1.03 - 1.60; p = .025) and re-operation (OR 1.26, 95% CI 1.03 - 1.53; p = .023) were also higher for patients who received GA vs. patients who received RA. No difference in mortality rate was observed between patients who received GA and those who received RA (5.7% vs. 7.1%; odds ratio 0.95, 95% CI 0.84 - 1.07). CONCLUSION: A statistically significant reduction in pulmonary complications was observed in patients who received RA for lower extremity amputation compared with GA.


Assuntos
Amputação Cirúrgica/efeitos adversos , Anestesia por Condução , Anestesia Geral/efeitos adversos , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica/mortalidade , Anestesia por Condução/efeitos adversos , Anestesia por Condução/mortalidade , Anestesia Geral/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/mortalidade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Ann Vasc Surg ; 76: 399-405, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33895258

RESUMO

BACKGROUND: Despite progress in perioperative care standards, there has not been a significant risk reduction in morbidity and mortality rates of lower extremity amputations, an intermediate risk surgery performed on high risk patients. The single-shot peripheral nerve block has shown equivocal impact on postoperative course following lower extremity amputation. Hence, we assessed the potential of preemptive use of continuous catheter-based peripheral nerve block in lower extremity amputations for reduction in pulmonary complications, acute post-operative pain scores, and opioid use in post-operative period. METHODS: A retrospective review of a quality improvement project initiated in 2018 was conducted to compare outcomes amongst general anesthesia in combination with a catheter-based peripheral nerve block (catheter group) and general anesthesia alone in patients receiving lower extremity amputation. The rate of postoperative pulmonary complications was identified as a primary endpoint. The secondary outcomes assessed were acute post-operative pain scores and opioid consumption up to 48 hours. Our analysis was adjusted for potential confounding variables inclusive of demographics, medical comorbidities, type of surgical procedure and smoking status. RESULTS: Ninety-six patients were included in the study (61 in the general anesthesia group, 35 in the catheter group). After adjusting for baseline demographics, comorbidities, surgical technique and smoking status, the odds of postoperative pulmonary complications were significantly lower with catheter-based peripheral nerve block in comparison to general anesthesia alone, OR 0.11 [95% CI, 0.01- 0.88] (P = 0.048). The decrease in acute pain scores was also observed in the catheter group when compared to general anesthesia alone, OR 0.72 [95% CI, 0.56 - 0.93] (P = 0.012). Similarly, the opioid consumption was also lower in the catheter group in comparison to general anesthesia alone, OR 0.97 [95% CI, 0.95 - 0.99] (P = 0.025). CONCLUSION: Preemptive use of continuous peripheral nerve block in patients undergoing lower extremity amputation reduces the incidence of pulmonary complications, acute postoperative pain scores and narcotic use in post-operative period.


Assuntos
Amputação Cirúrgica/efeitos adversos , Anestesia Geral , Extremidade Inferior/cirurgia , Pneumopatias/prevenção & controle , Bloqueio Nervoso , Manejo da Dor , Dor Pós-Operatória/prevenção & controle , Idoso , Analgésicos Opioides/uso terapêutico , Anestesia Geral/efeitos adversos , Bases de Dados Factuais , Feminino , Humanos , Extremidade Inferior/inervação , Pneumopatias/diagnóstico , Pneumopatias/etiologia , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/efeitos adversos , Manejo da Dor/efeitos adversos , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
A A Pract ; 15(3): e01417, 2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33687348

RESUMO

Health care workers performing aerosolizing procedures on patients with transmissible infections such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are at high-risk for disease acquisition. Current guidelines designed to protect health care workers during aerosolizing procedures prioritize personal protective equipment and enhanced infection control techniques, in particular during procedures such as intubation. To date, little emphasis has been placed on risk mitigation in the setting of bronchoscopy, a procedure that has significant aerosolization potential. Herein, we present an innovative closed bronchoscopy system designed to reduce aerosolization during bronchoscopy.


Assuntos
Broncoscopia/métodos , COVID-19/prevenção & controle , Controle de Infecções/métodos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Invenções , Manequins , Broncoscopia/instrumentação , COVID-19/transmissão , Pessoal de Saúde , Humanos , Equipamento de Proteção Individual
7.
J Cardiothorac Vasc Anesth ; 33(12): 3469-3475, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31451371

RESUMO

Three-dimensional printing is increasingly used in the health care industry. Making patient-specific anatomic task trainers has been one of the more commonly described uses of this technique specifically, allowing surgeons to perform complex procedures on patient-specific models in a nonoperative setting. With regard to transesophageal echocardiography (TEE) training, commercially available simulators have been increasingly used. Even though these simulators are haptic in nature and anatomically near realistic, they lack patient specificity and the training of the dynamic workflow and imaging protocol used in the operative setting. Herein a customized pulsatile left-sided heart model that uses patient-specific 3-dimensional printed valves under physiological intracardiac pressures as a TEE task trainer is described. With this model, dynamic patient-specific valvular anatomy can be visualized with actual TEE machines by trainees to familiarize themselves with the surgery equipment and the imaging protocol.


Assuntos
Competência Clínica , Ecocardiografia Transesofagiana/métodos , Imageamento Tridimensional/métodos , Valva Mitral/diagnóstico por imagem , Modelos Anatômicos , Impressão Tridimensional , Competência Clínica/normas , Ecocardiografia Transesofagiana/normas , Humanos , Imageamento Tridimensional/normas , Valva Mitral/anatomia & histologia , Imagens de Fantasmas/normas , Impressão Tridimensional/normas
SELEÇÃO DE REFERÊNCIAS