Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
1.
Scand J Gastroenterol ; : 1-11, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775234

RESUMO

BACKGROUND: Adenoma detection rate (ADR) is higher after a positive fecal immunochemical test (FIT) compared to direct screening colonoscopy. OBJECTIVE: This meta-analysis evaluated how ADR, the rates of advanced adenoma detection (AADR), colorectal cancer detection (CDR), and sessile serrated lesion detection (SSLDR) are affected by different FIT positivity thresholds. METHODS: We searched MEDLINE, EMBASE, CINAHL, and EBM Reviews databases for studies reporting ADR, AADR, CDR, and SSLDR according to different FIT cut-off values in asymptomatic average-risk individuals aged 50-74 years old. Data were stratified according to sex, age, time to colonoscopy, publication year, continent, and FIT kit type. Study quality, heterogeneity, and publication bias were assessed. RESULTS: Overall, 4280 articles were retrieved and fifty-eight studies were included (277,661 FIT-positive colonoscopies; mean cecal intubation 96.3%; mean age 60.8 years; male 52.1%). Mean ADR was 56.1% (95% CI 53.4 - 58.7%), while mean AADR, CDR, and SSLDR were 27.2% (95% CI 24.4 - 30.1%), 5.3% (95% CI 4.7 - 6.0%), and 3.0% (95% CI 1.7 - 4.6%), respectively. For each 20 µg Hb/g increase in FIT cut-off level, ADR increased by 1.54% (95% CI 0.52 - 2.56%, p < 0.01), AADR by 3.90% (95% CI 2.76 - 5.05%, p < 0.01) and CDR by 1.46% (95% CI 0.66 - 2.24%, p < 0.01). Many detection rates were greater amongst males and Europeans. CONCLUSIONS: ADRs in FIT-positive colonoscopies are influenced by the adopted FIT positivity threshold, and identified targets, importantly, proved to be higher than most current societal recommendations.

2.
World J Clin Cases ; 12(14): 2389-2395, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38765745

RESUMO

BACKGROUND: Morgagni hernia (MH) is a form of congenital diaphragmatic hernia (CDH) characterized by an incomplete formation of diaphragm, resulting in the protrusion of abdominal organs into the thoracic cavity. The estimated incidence of CDH is between 1 in 2000 and 1 in 5000 live births, although the true incidence is unknown. MH typically presents in childhood and can be diagnosed either prenatally or postnatally. However, it can also be asymptomatic and carry the risk of developing into a life-threatening condition in adulthood. CASE SUMMARY: A 76-year-old female with no history of prior abdominal surgeries presented for an elective colonoscopy for polyp surveillance. During the procedure, when approaching the hepatic flexure, the scope could not be advanced further despite multiple attempts. The patient experienced mild abdominal discomfort, leading to the abortion of the procedure. While in the recovery area, she developed increasing abdominal pains and hypotension. Urgent abdominal imaging revealed herniation of the proximal transverse colon through a MH into the chest with evidence of perforation. The patient underwent laparoscopic urgent colonic resection and primary hernia repair and was discharged uneventfully 2 d later. CONCLUSION: A MH is a rare condition in adults that can present as a life-threatening complication of colonoscopy, even in patients with a history of uneventful colonoscopies. This case highlights the importance of considering congenital and internal hernias when faced with sudden and unexplained difficulties during colonoscopy. If there is a suspicion of MH, the endoscopist should halt the procedure and immediately obtain abdominal imaging to confirm the diagnosis.

4.
Gastroenterology ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38331204

RESUMO

BACKGROUND & AIMS: Artificial intelligence (AI)-based optical diagnosis systems (CADx) have been developed to allow pathology prediction of colorectal polyps during colonoscopies. However, CADx systems have not yet been validated for autonomous performance. Therefore, we conducted a trial comparing autonomous AI to AI-assisted human (AI-H) optical diagnosis. METHODS: We performed a randomized noninferiority trial of patients undergoing elective colonoscopies at 1 academic institution. Patients were randomized into (1) autonomous AI-based CADx optical diagnosis of diminutive polyps without human input or (2) diagnosis by endoscopists who performed optical diagnosis of diminutive polyps after seeing the real-time CADx diagnosis. The primary outcome was accuracy in optical diagnosis in both arms using pathology as the gold standard. Secondary outcomes included agreement with pathology for surveillance intervals. RESULTS: A total of 467 patients were randomized (238 patients/158 polyps in the autonomous AI group and 229 patients/179 polyps in the AI-H group). Accuracy for optical diagnosis was 77.2% (95% confidence interval [CI], 69.7-84.7) in the autonomous AI group and 72.1% (95% CI, 65.5-78.6) in the AI-H group (P = .86). For high-confidence diagnoses, accuracy for optical diagnosis was 77.2% (95% CI, 69.7-84.7) in the autonomous AI group and 75.5% (95% CI, 67.9-82.0) in the AI-H group. Autonomous AI had statistically significantly higher agreement with pathology-based surveillance intervals compared to AI-H (91.5% [95% CI, 86.9-96.1] vs 82.1% [95% CI, 76.5-87.7]; P = .016). CONCLUSIONS: Autonomous AI-based optical diagnosis exhibits noninferior accuracy to endoscopist-based diagnosis. Both autonomous AI and AI-H exhibited relatively low accuracy for optical diagnosis; however, autonomous AI achieved higher agreement with pathology-based surveillance intervals. (ClinicalTrials.gov, Number NCT05236790).

5.
Scand J Gastroenterol ; 59(5): 608-614, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38333956

RESUMO

BACKGROUND AND AIMS: Accurate polyp size estimation during colonoscopy has an impact on clinical decision-making. A laser-based virtual scale endoscope (VSE) is available to allow measuring polyp size using a virtual adaptive scale. This study evaluates video-based polyp size measurement accuracy among expert endoscopists using either VSE or visual assessment (VA) with either snare as reference size or without any reference size information. METHODS: A prospective, video-based study was conducted with 10 expert endoscopists. Video sequences from 90 polyps with known reference size (fresh specimen measured using calipers) were distributed on three different slide sets so that each slide set showed the same polyp only once with either VSE, VA or snare-based information. A slide set was randomly assigned to each endoscopist. Endoscopists were asked to provide size estimation based on video review. RESULTS: Relative accuracies for VSE, VA, and snare-based estimation were 75.1% (95% CI [71.6-78.5]), 65.0% (95% CI [59.5-70.4]) and 62.0% (95% CI [54.8-69.0]), respectively. VSE yielded significantly higher relative accuracy compared to VA (p = 0.002) and to snare (p = 0.001). A significantly lower percentage of polyps 1-5 mm were misclassified as >5 mm using VSE versus VA and snare (6.52% vs. 19.6% and 17.5%, p = 0.004) and a significantly lower percentage of polyps >5 mm were misclassified as 1-5 mm using VSE versus VA and snare (11.4% vs. 31.9% and 14.9%, p = 0.038). CONCLUSIONS: Endoscopists estimate polyp size with the highest accuracy when virtual adaptive scale information is displayed. Using a snare to assist sizing did not improve measurement accuracy compared to displaying visual information alone.


Assuntos
Pólipos do Colo , Colonoscopia , Gravação em Vídeo , Humanos , Estudos Prospectivos , Colonoscopia/métodos , Pólipos do Colo/patologia , Competência Clínica , Masculino , Feminino
6.
Gastrointest Endosc Clin N Am ; 34(2): 189-203, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38395478

RESUMO

Upper gastrointestinal bleeding (UGIB) continues to be an important cause for emergency room visits and carries significant morbidity and mortality. Early resuscitative measures form the basis of the management of patients presenting with UGIB and can improve the outcomes of such patients including lowering mortality. In this review, using an evidence-based approach, we discuss the initial assessment and resuscitation of patients presenting with UGIB including identifying clues from history and physical examination to confirm UGIB, preendoscopic risk assessment tools, the role of early fluid resuscitation, utilization of blood products, use of pharmacologic interventions, and the optimal timing of endoscopy.


Assuntos
Varizes Esofágicas e Gástricas , Hemorragia Gastrointestinal , Humanos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Hemorragia Gastrointestinal/diagnóstico , Endoscopia Gastrointestinal/efeitos adversos , Medição de Risco , Morbidade , Varizes Esofágicas e Gástricas/complicações , Varizes Esofágicas e Gástricas/terapia
7.
Aliment Pharmacol Ther ; 59(5): 632-644, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38158721

RESUMO

BACKGROUND: Lower gastrointestinal bleeding (LGIB) is a common emergency with substantial associated morbidity and mortality. Elective colonoscopy plays an essential role in management, with an even more important role for radiology in the acute setting. Recent advances in the management of patients with LGIB warrant review as the management has recently evolved. AIMS: To provide a comprehensive and updated overview of advances in the approach to patients with LGIB METHODS: We performed a comprehensive literature search to examine the current data for this narrative review supplemented by expert opinion. RESULTS: The incidence of LGIB is increasing worldwide, partly related to an ageing population and the increasing use of antithrombotics. Diverticulosis continues to be the most common aetiology of LGIB. Pre-endoscopic risk stratification tools, especially the Oakland score, can aid appropriate patient triage. Adequate resuscitation continues to form the basis of management, while appropriate management of antithrombotics is crucial to balance the risk of worsening bleeding against increased cardiovascular risk. Radiological imaging plays an essential role in the diagnosis and treatment of acute LGIB, especially among unstable patients. Colonoscopy remains the gold-standard test for the elective management of stable patients. CONCLUSIONS: The management of LGIB has evolved significantly in recent years, with a shift towards radiological interventions for unstable patients while reserving elective colonoscopy for stable patients. A multidisciplinary approach is essential to optimise the outcomes of patients with LGIB.


Assuntos
Fibrinolíticos , Hemorragia Gastrointestinal , Humanos , Fibrinolíticos/efeitos adversos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Colonoscopia/métodos , Doença Aguda
8.
Endosc Int Open ; 11(9): E908-E919, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37810903

RESUMO

Background and study aims An independent observer can improve procedural quality. We evaluated the impact of the observer (Hawthorne effect) on important quality metrics during colonoscopies. Patients and Methods In a single-center comparative study, consecutive patients undergoing routine screening or diagnostic colonoscopy were prospectively enrolled. In the index group, all procedural steps and quality metrics were observed and documented, and the procedure was video recorded by an independent research assistant. In the reference group, colonoscopies were performed without independent observation. Colonoscopy quality metrics such as polyp, adenoma, serrated lesions, and advanced adenoma detection rates (PDR, ADR, SLDR, AADR) were compared. The probabilities of increased quality metrics were evaluated through regression analyses weighted by the inversed probability of observation during the procedure. Results We included 327 index individuals and 360 referents in the final analyses. The index group had significantly higher PDRs (62.4% vs. 53.1%, P =0.02) and ADRs (39.4% vs. 28.3%, P =0.002) compared with the reference group. The SLDR and AADR were not significantly increased. After adjusting for potential confounders, the ADR and SLDR were 50% (relative risk [RR] 1.51; 95%, CI 1.05-2.17) and more than twofold (RR 2.17; 95%, CI 1.05-4.47) more likely to be higher in the index group than in the reference group. Conclusions The presence of an independent observer documenting colonoscopy quality metrics and video recording the colonoscopy resulted in a significant increase in ADR and other quality metrics. The Hawthorne effect should be considered an alternative strategy to advanced devices to improve colonoscopy quality in practice.

9.
Endosc Int Open ; 11(7): E660-E672, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37593104

RESUMO

Background and study aims Malignant gastric outlet obstruction (MGOO) is traditionally treated with surgical gastrojejunostomy (SGJ), which is effective but associated with high rates of morbidity, or endoscopic stenting (ES), which is less invasive but associated with significant risk of stent dysfunction and need for reintervention. Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) provides a robust bypass without the invasiveness of surgery. Methods We performed a systematic review and meta-analysis comparing EUS-GE to SGJ and ES for MGOO. Electronic databases were searched from inception through February 2022. A meta-analysis was performed with results reported as odds ratios (ORs) with 95% confidence intervals (CIs) using random effects models. Primary outcomes included clinical success without recurrent GOO and adverse events (AEs). Results Sixteen studies involving 1541 patients were included. EUS-GE was associated with higher clinical success without recurrent GOO compared to ES or SGJ [OR 2.60, 95% CI1.58-4.28] and compared to ES alone [OR 5.08, 95% CI 3.42-7.55], but yielded no significant difference compared to SGJ alone [OR 1.94, 95% CI 0.97-3.88]. AE rates were significantly lower for EUS-GE compared to ES or SGJ grouped together [OR 0.34, 95% CI 0.20-0.58], or SGJ alone [OR 0.17, 95% CI 0.10-0.30] but were not significant different versus ES alone [OR 0.57, 95% CI 0.29-1.14]. Conclusions EUS-GE is the most successful approach to treating MGOO, exhibiting a lower risk of recurrent obstruction compared to ES, and fewer AEs compared to SGJ.

10.
Eur J Gastroenterol Hepatol ; 35(10): 1067-1074, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37577829

RESUMO

Evidence suggests that patients with inflammatory bowel disease are at higher risk of developing nonalcoholic fatty liver disease (NAFLD). However, there is limited information currently available on how NAFLD may affect the clinical course of IBD. Thus, we conducted a systematic review to evaluate the impact of NAFLD on IBD-related hospitalization outcomes. All observational studies assessing IBD-related hospitalization outcomes in patients with NAFLD were included. Exclusion criteria were studies published in languages other than English or French, or those involving pediatric population. Outcomes included IBD-related hospitalization and readmission rates, need for surgery, length of stay, inpatient mortality, and costs. Overall, 3252 citations were retrieved and seven studies met the inclusion criteria (1 574 937 patients); all were observational, of high quality, and originated in the United States. Measurable outcomes reported in these studies were few and with insufficient similarity across studies to complete a quantitative assessment. Only one study reports NAFLD severity. Two studies suggested a higher rate of hospitalization for patients with both NAFLD and IBD compared to IBD alone (incidence rate ratio of 1.54; 95% confidence interval: 1.33-1.79). This is the first systematic review to date that evaluates any possible association of NAFLD with IBD-related hospitalization outcomes. Despite the paucity and low quality of available data, our findings indicate that NAFLD may be associated with worse outcomes amongst IBD patients (especially Crohn's disease). Further and higher certainty of evidence is needed for better characterization of such clinical impact.


Assuntos
Hospitalização , Doenças Inflamatórias Intestinais , Hepatopatia Gordurosa não Alcoólica , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/mortalidade , Hepatopatia Gordurosa não Alcoólica/patologia , Doenças Inflamatórias Intestinais/complicações , Doenças Inflamatórias Intestinais/mortalidade , Doenças Inflamatórias Intestinais/patologia , Doenças Inflamatórias Intestinais/cirurgia , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Humanos , Tempo de Internação/estatística & dados numéricos
11.
J Can Assoc Gastroenterol ; 6(4): 145-151, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37538187

RESUMO

Background and aims: Identification and photo-documentation of the ileocecal valve (ICV) and appendiceal orifice (AO) confirm completeness of colonoscopy examinations. We aimed to develop and test a deep convolutional neural network (DCNN) model that can automatically identify ICV and AO, and differentiate these landmarks from normal mucosa and colorectal polyps. Methods: We prospectively collected annotated full-length colonoscopy videos of 318 patients undergoing outpatient colonoscopies. We created three nonoverlapping training, validation, and test data sets with 25,444 unaltered frames extracted from the colonoscopy videos showing four landmarks/image classes (AO, ICV, normal mucosa, and polyps). A DCNN classification model was developed, validated, and tested in separate data sets of images containing the four different landmarks. Results: After training and validation, the DCNN model could identify both AO and ICV in 18 out of 21 patients (85.7%). The accuracy of the model for differentiating AO from normal mucosa, and ICV from normal mucosa were 86.4% (95% CI 84.1% to 88.5%), and 86.4% (95% CI 84.1% to 88.6%), respectively. Furthermore, the accuracy of the model for differentiating polyps from normal mucosa was 88.6% (95% CI 86.6% to 90.3%). Conclusion: This model offers a novel tool to assist endoscopists with automated identification of AO and ICV during colonoscopy. The model can reliably distinguish these anatomical landmarks from normal mucosa and colorectal polyps. It can be implemented into automated colonoscopy report generation, photo-documentation, and quality auditing solutions to improve colonoscopy reporting quality.

12.
Gastroenterology ; 165(5): 1249-1261.e5, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37549753

RESUMO

BACKGROUND & AIMS: Endoscopic ultrasound-guided choledochoduodenostomy with a lumen-apposing metal stent (EUS-CDS) is a promising modality for management of malignant distal biliary obstruction (MDBO) with potential for better stent patency. We compared its outcomes with endoscopic retrograde cholangiopancreatography with metal stenting (ERCP-M). METHODS: In this multicenter randomized controlled trial, we recruited patients with MDBO secondary to borderline resectable, locally advanced, or unresectable peri-ampullary cancers across 10 Canadian institutions and 1 French institution. This was a superiority trial with a noninferiority assessment of technical success. Patients were randomized to EUS-CDS or ERCP-M. The primary end point was the rate of stent dysfunction at 1 year, considering competing risks of death, clinical failure, and surgical resection. Analyses were performed according to intention-to-treat principles. RESULTS: From February 2019 to February 2022, 144 patients were recruited; 73 were randomized to EUS-CDS and 71 were randomized to ERCP-M. The mean (SD) procedure time was 14.0 (11.4) minutes for EUS-CDS and 23.1 (15.6) minutes for ERCP-M (P < .01); 40% of the former was performed without fluoroscopy. Technical success was achieved in 90.4% (95% CI, 81.5% to 95.3%) of EUS-CDS and 83.1% (95% CI, 72.7% to 90.1%) of ERCP-M with a risk difference of 7.3% (95% CI, -4.0% to 18.8%) indicating noninferiority. Stent dysfunction occurred in 9.6% vs 9.9% of EUS-CDS and ERCP-M cases, respectively (P = .96). No differences in adverse events, pancreaticoduodenectomy and oncologic outcomes, or quality of life were noted. CONCLUSIONS: Although not superior in stent function, EUS-CDS is an efficient and safe alternative to ERCP-M in patients with MDBO. These findings provide evidence for greater adoption of EUS-CDS in clinical practice as a complementary and exchangeable first-line modality to ERCP in patients with MDBO. CLINICALTRIALS: gov, Number: NCT03870386.

13.
J Clin Med ; 12(16)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37629235

RESUMO

BACKGROUND: Several risk scores have attempted to risk stratify patients with acute upper gastrointestinal bleeding (UGIB) who are at a lower risk of requiring hospital-based interventions or negative outcomes including death. This systematic review and meta-analysis aimed to compare predictive abilities of pre-endoscopic scores in prognosticating the absence of adverse events in patients with UGIB. METHODS: We searched MEDLINE, EMBASE, Central, and ISI Web of knowledge from inception to February 2023. All fully published studies assessing a pre-endoscopic score in patients with UGIB were included. The primary outcome was a composite score for the need of a hospital-based intervention (endoscopic therapy, surgery, angiography, or blood transfusion). Secondary outcomes included: mortality, rebleeding, or the individual endpoints of the composite outcome. Both proportional and comparative analyses were performed. RESULTS: Thirty-eight studies were included from 2153 citations, (n = 36,215 patients). Few patients with a low Glasgow-Blatchford score (GBS) cutoff (0, ≤1 and ≤2) required hospital-based interventions (0.02 (0.01, 0.05), 0.04 (0.02, 0.09) and 0.03 (0.02, 0.07), respectively). The proportions of patients with clinical Rockall (CRS = 0) and ABC (≤3) scores requiring hospital-based intervention were 0.19 (0.15, 0.24) and 0.69 (0.62, 0.75), respectively. GBS (cutoffs 0, ≤1 and ≤2), CRS (cutoffs 0, ≤1 and ≤2), AIMS65 (cutoffs 0 and ≤1) and ABC (cutoffs ≤1 and ≤3) scores all were associated with few patients (0.01-0.04) dying. The proportion of patients suffering other secondary outcomes varied between scoring systems but, in general, was lowest for the GBS. GBS (using cutoffs 0, ≤1 and ≤2) showed excellent discriminative ability in predicting the need for hospital-based interventions (OR 0.02, (0.00, 0.16), 0.00 (0.00, 0.02) and 0.01 (0.00, 0.01), respectively). A CRS cutoff of 0 was less discriminative. For the other secondary outcomes, discriminative abilities varied between scores but, in general, the GBS (using cutoffs up to 2) was clinically useful for most outcomes. CONCLUSIONS: A GBS cut-off of one or less prognosticated low-risk patients the best. Expanding the GBS cut-off to 2 maintains prognostic accuracy while allowing more patients to be managed safely as outpatients. The evidence is limited by the number, homogeneity, quality, and generalizability of available data and subjectivity of deciding on clinical impact. Additional, comparative and, ideally, interventional studies are needed.

14.
Expert Rev Gastroenterol Hepatol ; 17(8): 795-803, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37496492

RESUMO

INTRODUCTION: Despite advances in the management of patients with upper gastrointestinal bleeding (UGIB), associated morbidity and mortality remain significant. Most patients, however, will experience favorable outcomes without a need for hospital-based interventions. Risk assessment scores may assist in such early risk-stratification. These scales may optimize identification of low-risk patients, resulting in better resource utilization, including a reduced need for early endoscopy and fewer hospital admissions. The aim of this article is to provide an updated detailed review of risk assessment scores in UGIB. AREA COVERED: A literature review identified past and currently available pre-endoscopic risk assessment scores for UGIB, with a focus on low-risk prediction. Strengths and weaknesses of the different scales are discussed as well as their impact on clinical decision-making. EXPERT OPINION: The current evidence supports using the Glasgow Blatchford Score as it is the most accurate tool available when attempting to identify low-risk patients who can be safely managed on an outpatient basis. Currently, no risk assessment tool appears accurate enough in confidently classifying patients as high risk. Future research should utilize more standardized methodologies, while favoring interventional trial designs to better characterize the clinical impact attributable to the use of such risk stratification schemes.


Assuntos
Hemorragia Gastrointestinal , Hospitalização , Humanos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Endoscopia Gastrointestinal , Medição de Risco/métodos , Fatores de Risco , Índice de Gravidade de Doença
15.
Gastroenterology ; 165(3): 762-772.e2, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37277078

RESUMO

BACKGROUND & AIMS: Current guidelines vary as to their recommendations addressing the role of hemostatic powders when managing patients with malignant gastrointestinal (GI) bleeding because these are based on very-low- to low-quality evidence, in large part due to a paucity of randomized trial data. METHODS: This was a patient- and outcome assessor-blinded, multicenter, randomized controlled trial. Patients presenting with active bleeding from an upper or lower GI lesion suspected to be malignant at index endoscopy between June 2019 and January 2022 were randomly allocated to receive either TC-325 alone or standard endoscopic treatment (SET). The primary outcome was 30-day rebleeding, and secondary objectives included immediate hemostasis and other clinically relevant endpoints. RESULTS: Overall, 106 patients made up the study population (55 TC-325 and 51 SET, after 1 exclusion in the TC-325 group and 5 in the SET group). Baseline characteristics and endoscopic findings did not differ between the groups. Thirty-day rebleeding was significantly lower in the TC-325 (2.1% TC-325 vs 21.3% SET; odds ratio, 0.09; 95% confidence interval [CI], 0.01-0.80; P = .003). Immediate hemostasis rates were 100% in the TC-325 group vs 68.6% in the SET group (odds ratio, 1.45; 95% CI, 0.93-2.29; P < .001). Other secondary outcomes did not differ between the 2 groups. Independent predictors of 6-month survival included the Charlson comorbidity index (hazard ratio, 1.17; 95% CI, 1.05-1.32; P = .007) and receiving an additional nonendoscopic hemostatic or oncologic treatment during 30 days after the index endoscopy (hazard ratio, 0.16; 95% CI, 0.06-0.43; P < .001) after adjustment for functional status, Glasgow-Blatchford score, and an upper GI source of bleeding. CONCLUSION: The TC-325 hemostatic powder results in greater immediate hemostasis rates followed by lower 30-day rebleeding rates when compared to contemporary SET. (ClinicalTrials.gov, Number: NCT03855904).


Assuntos
Neoplasias Gastrointestinais , Hemostase Endoscópica , Hemostáticos , Humanos , Pós , Hemostase Endoscópica/efeitos adversos , Hemostase Endoscópica/métodos , Recidiva Local de Neoplasia/terapia , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/cirurgia , Neoplasias Gastrointestinais/complicações , Neoplasias Gastrointestinais/cirurgia , Endoscopia Gastrointestinal/efeitos adversos , Hemostáticos/uso terapêutico , Recidiva
16.
J Can Assoc Gastroenterol ; 6(3): 97-105, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37273970

RESUMO

Background and Aims: Artificial intelligence-aided colonoscopy significantly improves adenoma detection. We assessed the cost-effectiveness of the GI Genius technology, an artificial intelligence-aided computer diagnosis for polyp detection (CADe), in improving colorectal cancer outcomes, adopting a Canadian health care perspective. Methods: A Markov model with 1-year cycles and a lifetime horizon was used to estimate incremental cost-effectiveness ratio comparing CADe to conventional colonoscopy polyp detection amongst patients with a positive faecal immunochemical test. Outcomes were life years (LYs) and quality-adjusted life years (QALY) gained. The analysis applied costs associated with health care resource utilization, including procedures and follow-ups, from a provincial payer's perspective using 2022 Canadian dollars. Effectiveness and cost data were sourced from the literature and publicly available databases. Extensive probabilistic and deterministic sensitivity analyses were performed, assessing model robustness. Results: Life years and QALY gains for the CADe and conventional colonoscopy groups were 19.144 versus 19.125 and 17.137 versus 17.113, respectively. CADe and conventional colonoscopies' overall per-case costs were $2990.74 and $3004.59, respectively. With a willingness-to-pay pre-set at $50,000/QALY, the incremental cost-effectiveness ratio was dominant for both outcomes, showing that CADe colonoscopy is cost-effective. Deterministic sensitivity analysis confirmed that the model was sensitive to the incidence risk ratio of adenoma per colonoscopy for large adenomas. Probabilistic sensitivity analysis showed that the CADe strategy was cost-effective in up to 73.4% of scenarios. Conclusion: The addition of CADe solution to colonoscopy is a dominant, cost-effective strategy when used in faecal immunochemical test-positive patients in a Canadian health care setting.

17.
Endosc Int Open ; 11(5): E480-E489, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37206693

RESUMO

Background and study aims Incomplete resection of 4- to 20-mm colorectal polyps occur frequently (> 10 %), putting patients at risk for post-colonoscopy colorectal cancer. We hypothesized that routine use of wide-field cold snare resection with submucosal injection (CSP-SI) might reduce incomplete resection rates (IRRs). Patients and methods Patients aged 45 to 80 years undergoing elective colonoscopies were enrolled in a prospective clinical study. All 4- to 20-mm non-pedunculated polyps were resected using CSP-SI. Post-polypectomy margin biopsies were obtained to determine IRRs through histopathology assessment. The primary outcome was IRR, defined as remnant polyp tissue found on margin biopsies. Secondary outcomes included technical success and complication rates. Results A total of 429 patients (median age 65 years, 47.1 % female, adenoma detection rate 40 %) with 204 non-pedunculated colorectal polyps 4 to 20 mm removed using CSP-SI were included in the final analysis. CSP-SI was technical successful in 97.5 % (199/204) of cases (5 conversion to hot snare polypectomy). IRR for CSP-SI was 3.8 % (7/183) (95 % confidence interval [CI] 2.7 %-5.5 %). IRR was 1.6 % (2/129), 16 % (4/25), and 3.4 % (1/29) for adenomas, serrated lesions, and hyperplastic polyps respectively. IRR was 2.3 % (2/87), 6.3 % (4/64), 4.0 % (6/151), and 3.1 % (1/32) for polyps 4 to 5 mm, 6 to 9 mm, < 10 mm, and 10 to 20 mm, respectively. There were no CSP-SI-related serious adverse events. Conclusions Use of CSP-SI results in lower IRRs compared to what has previously been reported in the literature for hot or cold snare polypectomy when not using wide-field cold snare resection with submucosal injection. CSP-SI showed an excellent safety and efficacy profile, however comparative studies to CSP without SI are required to confirm these results.

18.
Endosc Int Open ; 11(4): E368-E385, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37102185

RESUMO

Background and study aims Novel topical hemostatic agents have shown promising results in treating patients with non-variceal upper gastrointestinal bleeding (NVUGIB). However, data are limited even in published meta-analyses as to their role, especially compared to conventional endoscopic approaches. The aim of this study was to perform a highly comprehensive systematic review assessing the effectiveness of topical hemostatic agents in UGIB in different clinical settings. Methods We performed a literature search of OVID MEDLINE, EMBASE, and ISI Web of Knowledge databases through September 2021. Studies assessing the efficacy of topical hemostatic agents in UGIB were included. Main outcomes were immediate hemostasis and overall rebleeding. Results A total of 980 citations were identified and 59 studies with a total of 3,417 patients were included in the analysis. Immediate hemostasis was achieved in 93 % (91 %; 94 %), with similar results according to etiology (NVUGIB vs. variceal), topical agent used, or treatment strategy (primary vs. rescue). The overall rebleeding rate was 18 % (15%; 21 %) with the majority of rebleeds occurring in the first 7 days. Among comparative studies, topical agents achieved immediate hemostasis more often than standard endoscopic modalities (OR 3.94 [1.73; 8.96), with non-different overall rebleeding odds (OR 1.06 [0.65; 1.74]). Adverse events occurred in 2 % (1 %; 3 %). Study quality was overall low to very low. Conclusions Topical hemostatic agents are effective and safe in the management of UGIB with favorable outcomes when compared to conventional endoscopic modalities across a variety of bleeding etiologies. This is especially true in novel subgroup analyses that assessed immediate hemostasis and rebleeding among RCTs and in malignant bleeding. Due to methodological limitations of available data, additional studies are needed to ascertain their effectiveness more confidently in the management of patients with UGIB.

19.
Endoscopy ; 55(9): 822-835, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37023789

RESUMO

BACKGROUND : We compared the effectiveness of optional split-dose bowel preparation (SDBP) with mandatory SDBP for morning colonoscopies in usual clinical practice. METHODS : Adult patients undergoing outpatient early morning (8:00 AM-10:30 PM) and late morning (10:30 AM-12:00 PM) colonoscopies were included. Written bowel preparation instructions were provided based on randomization: one group were instructed to take their bowel preparation (4 L polyethylene glycol solution) as a split dose (mandatory), while the comparator group was allowed the choice of SDBP or single-dose bowel preparation administered entirely on the day before (optional). The primary end point, using noninferiority hypothesis testing with a 5 % margin, was adequate bowel cleanliness measured by the Boston Bowel Preparation Scale (BBPS) and defined by a BBPS score ≥ 6. RESULTS : Among 770 randomized patients with complete data, there were 267 mandatory SDBP and 265 optional SDBP patients for early morning colonoscopies, and 120 mandatory SDBP and 118 optional SDBP patients for late morning colonoscopies. Optional SDBP was inferior to mandatory SDBP, with a lower proportion of adequate BBPS cleanliness for early morning colonoscopies (78.9 % vs. 89.9 %; absolute risk difference [aRD] 11.0 %, 95 %CI 5.9 % to 16.1 %), but was not statistically different for late morning colonoscopies (76.3 % vs. 83.3 %; aRD 7.1 %, 95 %CI -1.5 % to 15.5 %). CONCLUSIONS : Optional SDBP is inferior to mandatory SDBP in providing adequate bowel preparation quality for early morning colonoscopies (8:00 AM-10:30 AM), and probably inferior for late morning colonoscopies (10:30 AM-12:00 PM).


Assuntos
Catárticos , Polietilenoglicóis , Adulto , Humanos , Estudos Prospectivos , Colonoscopia/métodos , Esquema de Medicação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA