Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 99: 332-340, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37839654

RESUMO

BACKGROUND: The endovascular repair of infrarenal abdominal aortic aneurysms can be performed with a wide variety of devices. Many of these grafts elevate the aortic bifurcation which can limit future repairs if the graft material fails thereby creating a type III endoleak to aorto-uniliac grafts. Many manufacturers have grafts susceptible to this, but we have seen this in the Medtronic AneuRx graft. Our goal is to provide technical details and outcomes regarding a novel technique to reline these grafts while maintaining inline flow to the iliac arteries. METHODS: This was a single-institution review of patients who had endoleaks requiring intervention after a previously placed graft with an elevated aortic bifurcation. Primary outcomes included technical success defined as placement of all planned devices, resolution of type III endoleak, aneurysm size at follow-up, and requirement of reintervention. Secondary outcomes included 30-day complications, aneurysm-related mortality, and all-cause mortality. Technical details of the operation include back-table deployment of an Ovation device, modification of the deployment system tether and pre-emptive placement of an up and over 0.014″ wire. The wire is placed up and over and hung outside the contralateral gate. Once the main body is introduced above the old graft, the 0.014" is snared from the contralateral side and externalized. The main body is then able to be seated at the bifurcation as the limb is not fully deployed and then device deployment is completed per instructions for use. RESULTS: Our study consists of 4 individuals, 3 of which had an abdominal aortic aneurysm initially managed with an AneuRx endovascular aneurysm repair and 1 with a combination of Gore and Cook grafts. All 4 patients were male with an average age of 84.5 years at time of reline. All patients had at least 10 years between initial surgery and reline at our institution. Primary outcomes revealed no type 1 or 3 endoleaks at follow-up, technical success was 100% and 1 patient required reintervention for aneurysm growth and type 2 endoleak. In terms of our secondary outcomes, there was 1 postoperative complication which was cardiac dysfunction secondary to demand ischemia, aneurysm-related mortality was 0% and all-cause mortality was 25% at average follow-up of 2.44 years. CONCLUSIONS: As individuals continue to age, there are more patients who would benefit from less invasive reinterventions following endovascular aneurysm repair. Whether this is due to aortic degeneration, stent migration, or stent material damage is not always known. In this study, we present an endovascular approach to treating type III endoleak patients with a previous graft and elevated aortic bifurcation using Ovation stent grafts and found no evidence of type 1 or 3 endoleaks on follow-up imaging. This approach may allow patients with type III endoleak the option of a minimally invasive, percutaneous approach where they previously would not have had one.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Correção Endovascular de Aneurisma , Fatores de Risco , Resultado do Tratamento , Stents/efeitos adversos , Desenho de Prótese
2.
Ann Vasc Surg ; 97: 184-191, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37574045

RESUMO

BACKGROUND: Physician-modified endografts and custom-manufactured devices use branched and fenestrated techniques (F/BEVAR) to repair complex aneurysms. Traditionally, many of these are deployed through a combination of upper and lower extremity access. However, with newer steerable sheaths, you can now simulate upper extremity (UEM) access from a transfemoral approach. Single-institution studies have demonstrated increased risks of access site complications and stroke when UEM access is used. This study compares outcomes after F/BEVAR in a national database between total transfemoral (TTF) access and mixed UEM access. METHODS: This study is an analysis of the Vascular Quality Initiative for all patients who underwent F/BEVAR from 2014 to 2021. Patients were stratified based on a TTF delivery of all devices versus any UEM access for deployment of target vessel stents. Primary outcomes included stroke, myocardial infarction (MI), and perioperative death. Secondary outcomes included access site hematoma, occlusion or embolization, operative time, fluoroscopy time, and technical success. Multivariable linear and logistic regression analyses were performed. RESULTS: Three thousand one hundred forty six patients underwent an F/BEVAR: 2,309 (73.4%) TTF and 837 (26.6%) UEM. Logistic regression analysis indicated a two-fold increased risk of death and MI and a three-fold increased risk of stroke in the UEM group. Furthermore, there is decreased operative time (221 vs. 297 min, P < 0.001) and fluoroscopy time (62 vs. 80 min, P < 0.001) in the TTF group and no difference in technical success between groups (96% vs. 97%, P = 0.159). Finally, there was a decrease in access site hematoma 2.54% vs. 4.31% (P = 0.013), access site occlusion 0.61% vs. 1.91% (P = 0.001), and extremity embolization 2.17% vs. 3.58% (P = 0.026) in the TTF versus UEM group. CONCLUSIONS: This study using Vascular Quality Initiative data demonstrates that patients who undergo an F/BEVAR using UEM access have an increased risk of perioperative MI, death, and stroke compared to TTF access.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Correção Endovascular de Aneurisma , Fatores de Risco , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Extremidade Superior/irrigação sanguínea , Acidente Vascular Cerebral/complicações , Infarto do Miocárdio/etiologia , Hematoma/etiologia , Hematoma/cirurgia , Estudos Retrospectivos , Prótese Vascular
3.
J Vasc Surg ; 77(4): 982-990.e2, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36581011

RESUMO

OBJECTIVE: The introduction of endovascular procedures has revolutionized the management of complex aortic aneurysms. Although repair has traditionally required longer operative times and increased radiation exposure compared with simple endovascular aneurysm repair, the recent introduction of three-dimensional technology has become an invaluable operative adjunct. Surgical augmented intelligence (AI) is a rapidly evolving tool initiated at our institution in June 2019. In our study, we sought to determine whether this technology improved patient and operator safety. METHODS: A retrospective review of patients who had undergone endovascular repair of complex aortic aneurysms (pararenal, juxtarenal, or thoracoabdominal), type B dissection, or infrarenal (endoleak, coil placement, or renal angiography with or without intervention) at a tertiary care center from August 2015 to November 2021 was performed. Patients were stratified according to the findings from intelligent maps, which are patient-specific AI tools used in the operating room in conjunction with real-time fluoroscopic images. The primary outcomes included operative time, radiation exposure, fluoroscopy time, and contrast use. The secondary outcomes included 30-day postoperative complications and long-term follow-up. Linear regression models were used to evaluate the association between AI use and the main outcomes. RESULTS: During the 6-year period, 116 patients were included in the present study, with no significant differences in the baseline characteristics. Of the 116 patients, 76 (65.5%) had undergone procedures using AI and 40 (34.5%) had undergone procedures without AI software. The intraoperative outcomes revealed a significant decrease in radiation exposure (AI group, 1955 mGy; vs non-AI group, 3755 mGy; P = .004), a significant decrease in the fluoroscopy time (AI group, 55.6 minutes; vs non-AI group, 86.9 minutes; P = .007), a decrease in the operative time (AI group, 255 minutes; vs non-AI group, 284 minutes; P = .294), and a significant decrease in contrast use (AI group, 123 mL; vs non-AI group, 199 mL; P < .0001). No differences were found in the 30-day and long-term outcomes. CONCLUSIONS: The results from the present study have demonstrated that the use of AI technology combined with intraoperative imaging can significantly facilitate complex endovascular aneurysm repair by decreasing the operative time, radiation exposure, fluoroscopy time, and contrast use. Overall, evolving technology such as AI has improved radiation safety for both the patient and the entire operating room team.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Aórtico , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/complicações , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia
4.
Ann Vasc Surg ; 86: 117-126, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35809740

RESUMO

BACKGROUND: Aortic aneurysms are normally treated by an endovascular approach. Due to the lack of devices and increasing experience, there is a growing number of complex aneurysms undergoing repair by physician modified endografts (PMEGs). Previously, our practice was to target visceral vessels exclusively through upper extremity access. We have since then shifted to an all transfemoral approach when possible. This study aims to show the operative benefits of transfemoral only approaches. METHODS: Patients who underwent a PMEG at a tertiary center between 2015 and 2020 were included. Patients were stratified into 2 groups based on branched vessel approach-transfemoral only versus axillary or composite (axillary and femoral). Forty-one patients had a pararenal or type IV thoracoabdominal aortic aneurysm (TAAA) and 15 patients had more complex TAAA. Primary outcomes were operative time, radiation exposure, fluoroscopy time, contrast, and blood loss. Secondary outcomes were 30-day mortality and major adverse events. Linear regression models were used to evaluate the association between approach type and the main outcomes. RESULTS: Fifty-six patients were included with 48% (n = 27) in the transfemoral group and 52% (n = 29) in the axillary/composite group. Baseline characteristics were similar between the groups. Intraoperative outcomes revealed significant increase in the average operative time (418 vs. 246 min, P < 0.001), in radiation exposure (2,755 vs. 1,740 mGy, P = 0.03), in fluoroscopy time (108 vs. 74 min, P = 0.01) and in blood loss (579 vs. 202 cc, P = 0.002) in the axillary/composite group compared to the transfemoral group. There was no significant difference in 30-day mortality or major adverse events including stroke. CONCLUSIONS: This study shows a transfemoral approach to complex endovascular aortic aneurysm repair as opposed to axillary/composite approach has decreased operative time, radiation exposure, and fluoroscopy time and no significant differences in 30-day mortality or major adverse events. When treating complex aneurysms, improving efficiency is important to minimize morbidity to patients and operators.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Médicos , Humanos , Prótese Vascular , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Risco , Complicações Pós-Operatórias , Fatores de Tempo , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Extremidade Superior/cirurgia
5.
Ann Vasc Surg ; 29(5): 1017.e15-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25747887

RESUMO

Congenital anomalies of the inferior vena cava (IVC), although rare, are a risk factor for lower limb deep venous thrombosis (DVT). A 19-year-old male presented with a left flank and groin pain caused by iliofemoral venous thrombosis. Vascular imaging by computed tomography (CT) scanning and venography demonstrated agenesis of the IVC. Catheter-directed thrombolysis via a popliteal vein was attempted but did not alter the patency of the common femoral vein outflow collaterals into the retroperitoneal azygous venous system. The patient was anticoagulated using systemic heparin infusion and clinical symptoms resolved within 5 days. He was transitioned to oral Coumadin anticoagulation, and follow-up venous duplex testing demonstrated no infrainguinal DVT and phasic venous flow with respiration in the femoral vein indicating patent collateral veins. Anomalies of the IVC are present in 0.3-0.5% of otherwise healthy individuals. Agenesis of the IVC has an incidence of 0.0005-1% in the general population but is found in almost 5% of patients <30 years of age with unprovoked lower limb DVT. In adults, IVC agenesis anomaly can cause diagnostic problems in the paravertebral area because of the tumor-like appearance of the azygous venous collaterals on noncontrast CT imaging. In young adults presenting with unprovoked lower limb DVT, the presence of an IVC anomaly should be considered and evaluated for by venous duplex testing and if necessary CT venography.


Assuntos
Malformações Vasculares/complicações , Veia Cava Inferior/anormalidades , Trombose Venosa/etiologia , Humanos , Masculino , Flebografia , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler Dupla , Malformações Vasculares/diagnóstico , Trombose Venosa/diagnóstico , Adulto Jovem
6.
J Vasc Surg ; 61(4): 933-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25600333

RESUMO

OBJECTIVE: The introduction of carotid stenting has led to a rapid rise in the number of vascular specialists performing this procedure. The Carotid Revascularization Endarterectomy vs Stenting Trial (CREST) has shown that carotid stenting can be performed with an equivalent major event rate compared with carotid endarterectomy. However, there is still controversy about the appropriate training and experience required to safely perform this procedure. This observational study examined the performance of carotid stenting with regard to specialty and case volume. METHODS: From 2004 to 2011, inpatients diagnosed with carotid stenosis who had a carotid stenting procedure were extracted from the Nationwide Inpatient Sample database. The cohort was separated on the basis of the provider performing the procedure (surgeon vs interventionalist), hospital location, and volume. Surgeons were defined as providers who also performed either a carotid endarterectomy or femoral-popliteal bypass during the same time interval. Primary end points analyzed included stroke, myocardial infarction, and 30-day mortality. Length of stay and hospital costs were also analyzed as secondary outcomes. RESULTS: A total of 20,663 cases of carotid stenting were found; 15,305 (74%) cases were identified to be performed by a "surgeon," whereas 5358 (26%) were done by an "interventionalist." The majority of cases were done at hospitals in urban locations (96.51%) and designated teaching institutions (61.47%). Unadjusted outcomes were similar between surgeons and interventionalists in terms of stroke (4.33% and 4.41%), myocardial infarction (2.10% and 2.13%), and mortality (0.84% and 1.03%) respectively. Qualitatively, volume per 10 cases was shown to decrease the risk of stroke. Adjusted multivariate analysis demonstrated no statistical significance between primary end point outcomes. However, length of stay (2.81 vs 3.08 days) and total charges ($48,087.61 and $51,718.77) were lower for procedures performed by surgeons. CONCLUSIONS: Surgeons are performing the majority of carotid stent procedures in the United States. The volume of cases performed by a provider, rather than the provider's specialty, appears to be a stronger predictor of adverse outcomes for carotid stenting. There were, however, significant cost differences between surgeons and interventionalists, which needs to be further evaluated at an institutional level.


Assuntos
Angioplastia/instrumentação , Estenose das Carótidas/terapia , Competência Clínica , Especialização , Stents , Cirurgiões , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Angioplastia/economia , Angioplastia/mortalidade , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/economia , Estenose das Carótidas/mortalidade , Redução de Custos , Bases de Dados Factuais , Feminino , Custos Hospitalares , Hospitais com Alto Volume de Atendimentos , Hospitais com Baixo Volume de Atendimentos , Hospitais de Ensino , Humanos , Tempo de Internação , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents/economia , Acidente Vascular Cerebral/etiologia , Cirurgiões/economia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
8.
Ann Vasc Surg ; 21(5): 629-32, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17532604

RESUMO

Aortoenteric fistulae require urgent definitive intervention and traditionally carry a high mortality. We describe a patient who suffered a traumatic aortic dissection following an auto versus pedestrian collision. He underwent open fenestration of his infrarenal aorta and visceral resection, complicated by abdominal sepsis and enterocutaneous fistulae. One month later he developed massive hematemesis, and endoscopic examination revealed an aortoduodenal fistula. Due to an impassable abdominal wall, a stent-graft repair was performed. This report describes the successful use of endovascular techniques to achieve immediate hemostasis in an actively hemorrhaging aortoduodenal fistula. An endovascular approach provides a valuable option in settings where a hostile abdomen precludes the traditional open technique and may serve as a bridge to later definitive repair.


Assuntos
Aorta Abdominal/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Duodenopatias/cirurgia , Hemorragia Gastrointestinal/cirurgia , Fístula Intestinal/cirurgia , Stents , Fístula Vascular/cirurgia , Prótese Vascular , Seguimentos , Hematemese/cirurgia , Hemostasia Cirúrgica/métodos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA