Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Neonatal Perinatal Med ; 14(1): 67-74, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32741782

RESUMO

BACKGROUND: Bilateral choanal atresia in patients with CHARGE syndrome becomes symptomatic immediately after birth. A prompt diagnosis, the implementation of sufficient preliminary measures, and the delivery of surgical therapy are crucial. This article is intended to assist in terms of diagnostics and a therapy recommendation. METHODS: We performed a retrospective study using the medical records of all newborns in the University Hospital in Bonn, diagnosed with bilateral choanal atresia and CHARGE syndrome and underwent surgery at the Department of Otorhinolaryngology, Head and Neck Surgery. RESULTS: A total of 21 patients have been treated with a unilateral or bilateral choanal atresia. 14 patients were primarily treated with transnasal endoscopy or underwent transnasal endoscopic surgery as a follow-up intervention (73.68%). Nine patients had a syndromal appearance, which was considered a definite diagnosis in six patients (five with CHARGE syndrome). All five patients with CHARGE syndrome received transnasal endoscopic treatment and a stent was inserted. DISCUSSION: Bilateral choanal atresia can be a life-threatening situation requiring acute measures. The therapeutic trend goes towards transnasal endoscopic resection. Primary intervention should be: minimally invasive, one-stage surgery, functional, and associated with low complication rates. Patency can be increased by saline irrigations, topical corticosteroids, endoscopic controls, and regular dilatation. The insertion of stents is controversially discussed but can be useful in syndromal patients. However, adjuvant therapy with a stent and mitomycin C is increasingly being abandoned. A significantly higher recurrence rate must be expected in association with CHARGE syndrome. Stenting should be considered on an individual basis. Continuous training and support of the parents are obligatory.


Assuntos
Síndrome CHARGE/diagnóstico , Síndrome CHARGE/cirurgia , Atresia das Cóanas/diagnóstico , Atresia das Cóanas/cirurgia , Stents , Síndrome CHARGE/complicações , Síndrome CHARGE/fisiopatologia , Atresia das Cóanas/complicações , Atresia das Cóanas/fisiopatologia , Endoscopia/métodos , Feminino , Humanos , Recém-Nascido , Masculino , Recuperação de Função Fisiológica , Resultado do Tratamento
2.
Laryngorhinootologie ; 95(3): 178-81, 2016 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-26669581

RESUMO

UNLABELLED: INDRODUCTION: The regular application of transit time flow measurement in microvascular anastomoses during heart surgery has lead to improvements of the outcome of coronary artery bypass grafts. Our study was meant to discover whether this measurement method was also applicable for evaluation and optimization of microvascular arterial anastomoses of radial forearm flaps. METHODS: In this prospective examination a combining ultrasound imaging and transit time flow measurement device (VeriQ, MediStim) was used during surgery to assess anastomotic quality of 15 radial forearm flaps. Pulsatility index (PI) and mean blood flow were measured immediately after opening the arterial anastomosis as well as 15 min afterwards. Furthermore, application time and description of handling were recorded seperately for every assessment. RESULTS: Mean blood flow immediately after opening the anastomosis and 15 min later were 3.9 and 3.4 ml/min resepectively showing no statistically significant difference (p=0.96). There was no significance in the increase of pulsatility index from 22.1 to 27.2 (p=0.09) during the same time range, either. Due to measurement results showing atypical pulse curves in 2 cases decision for surgical revision of the anastomoses was made. All forearm flaps showed good vascularisation during follow-up. Time for device set up, probe placement and measurements was about 20 min. Handling was described to be uncomplicated without exception. There were no noteworthy problems. CONCLUSION: Transit time flow measurement contributes to the improvement of anastomotic quality and therefore to the overall outcome of radial forearm flaps. The examined measurement method provides objective results and is useful for documentation purposes.


Assuntos
Anastomose Cirúrgica , Velocidade do Fluxo Sanguíneo , Volume Sanguíneo , Retalhos de Tecido Biológico/irrigação sanguínea , Retalhos de Tecido Biológico/cirurgia , Microcirurgia , Neoplasias Otorrinolaringológicas/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Análise de Onda de Pulso , Ultrassonografia/instrumentação , Humanos , Neoplasias Hipofaríngeas/cirurgia , Masculino , Pessoa de Meia-Idade , Neoplasias Orofaríngeas/cirurgia , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA