Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Ther Adv Urol ; 16: 17562872241249603, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38779495

RESUMO

Bladder paraganglioma is a rare neuroendocrine neoplasm, either functional or non-functional, arising from the urinary bladder. Functional variants present with catecholamine-related symptoms, while non-functional variants pose diagnostic challenges, mimicking urothelial carcinoma. Misdiagnosis risks underscore the importance of accurate identification for appropriate patient management. In this case, a 52-year-old man, diagnosed incidentally with hypertension and reported occasional post-micturition tachycardia, underwent abdominal ultrasound for known hepatic cyst follow-up, revealing an oval hypoechoic bladder mass. Initial consideration of bladder urothelial carcinoma prompted further investigation with contrast-enhanced CT scan and cystoscopy that confirmed extrinsic mass nature, and subsequent robotic-assisted partial cystectomy was performed. Histologically, the removed mass exhibited characteristic features of bladder paraganglioma. Postoperative recovery was uneventful, with resolution of post-micturition tachycardia at 1 month. Follow-up includes endocrinological evaluation and a 6-month CT scan. In conclusion, bladder paraganglioma should be considered in para-vesical mass differentials. This case highlights the importance of meticulous history collection, even in asymptomatic patients, the need for a multidisciplinary approach for accurate diagnosis and management of this rare condition, and the robotic approach as a viable option.

2.
Life (Basel) ; 13(8)2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37629548

RESUMO

MRE has become a standard imaging test for evaluating patients with small bowel pathology, but the indications, interpretation of imaging findings, methodology, and appropriate use must be standardized and widely known. Several signs of small bowel damage in inflammatory and non-inflammatory small bowel pathology include strictures, abscess, inflammatory activity, sinus tract, wall edema, fistula, mucosal lesions, and mesentery fat hypertrophy, all of which are widely and accurately explained by MRE. MRE is a non-invasive modality that accurately assesses the intra-luminal, parietal, and extra-luminal small bowel. The differential MRE appearance allows us to distinguish between different small bowel pathologies, such as neoplastic and non-neoplastic small bowel diseases. The purpose of this paper is to present the MRE technique, as well as the interpretation of imaging findings, through the approach of a rigorous stepwise methodology.

4.
Clin Exp Med ; 23(3): 759-766, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36129558

RESUMO

Juvenile idiopathic arthritis (JIA) is a common pediatric rheumatic disease. Renal manifestations have been rarely observed in JIA, although amyloidosis could be a renal complication in systemic JIA (sJIA). To investigate renal damage in JIA children and to establish the relationship with treatment. Blood urea nitrogen (BUN), creatinine, cystatin C (CysC), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), urinary albumin excretion (UAE), estimated glomerular filtration rate (eGFR), and renal resistive index (RRI) were assessed in 49 JIA children (9 boys/40 girls, mean age 10.3 ± 3.8 years) and in 49 healthy controls (24 boys/25 girls, mean age 11.3 ± 3.4 years). Twenty-two JIA patients were on methotrexate (MTX) therapy (group A) and 27 on biologic drugs (group B). CysC and BUN (respectively, 0.8 ± 0.1 vs. 0.7 ± 0.1 mg/dl; 13.3 ± 2.9 vs. 11.7 ± 1.4 mg/dl) were higher (p ≤ 0.001) whereas creatinine and eGFR (respectively, 0.5 ± 0.1 vs. 0.6 ± 0.1 mg/dl; 99.2 ± 10.5 vs. 122.5 ± 19.8 ml/min/1.73 m2) were lower in JIA children as compared to controls (p < 0.001). UAE resulted higher in patients than in controls (p = 0.003). Mean RRI was higher in JIA children than controls (0.7 ± 0.04 vs. 0.6 ± 0.04; p < 0.001). Group B showed higher mean RRI than group A (0.7 ± 0.1 vs. 0.7 ± 0.04; p < 0.001). Associations were found between RRI and ESR, JADAS-27, disease state, BMI-SDS (p < 0.001), CRP (p = 0.003) and eGFR (p = 0.001). JIA children had reduced eGFR, increased UAE and higher RRI values, than controls. RRIs were higher in patients on biologic drugs than MTX group and were associated with inflammation indexes and disease state, suggesting a direct effect of the disease.


Assuntos
Artrite Juvenil , Masculino , Feminino , Criança , Humanos , Adolescente , Artrite Juvenil/complicações , Artrite Juvenil/tratamento farmacológico , Creatinina , Metotrexato/uso terapêutico , Rim , Inflamação/complicações
5.
Insights Imaging ; 12(1): 100, 2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34259932

RESUMO

Gallbladder metastasis (GM) is a rare condition, often with a late diagnosis or detected upon autopsy. There is no extensive literature on the imaging diagnosis of GM. Here we present a comprehensive review of the literature with the aim of helping to interpret the clinical findings and imaging features of such patients. Few studies on GM are reported in literature. GM by melanoma accounts for about 55.6% of cases. The remaining cases origin from breast cancer (13.6%), hepatocellular carcinoma (13.6%), renal cell carcinoma (6.8%), lung cancer (4.5%), lymphoma (3.5%) and gastric cancer (2.4%). The most common clinical presentation of GM is abdominal pain from cholecystitis due to obstruction of the cystic duct. The main ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) findings that clinicians and radiologists should consider in their everyday medical activity were discussed. The diagnosis of GM was often achieved through a combination of more than one imaging modality. In more than 90% of cases, the diagnosis of GM is often late and combined with other organs involvement in the terminal stage of the malignancy. The knowledge of the clinical features and different imaging techniques through careful evaluation of the gallbladder can help to achieve early diagnosis and avoid misdiagnosis or false negative results.

6.
Arch Ital Urol Androl ; 93(1): 64-67, 2021 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-33754611

RESUMO

INTRODUCTION: Testicular cancers represent about 5% of all urological malignancies and 1-1.5% of all male neoplasms. Most of the testicular cancers are localized (68%) at diagnosis. Bulky masses in the scrotum are rare. We present a rare case of bulky testicular cancer with retroperitoneal spread through the inguinal canal. CASE REPORT: A 44-year-old man came to the emergency department referring weakness and the presence of a scrotal mass. At physical examination, a voluminous mass was found, with necrotic phenomena within the scrotum. Abdomen was tense and sore. Abdominal CT scan revealed a bulky testicular mass spreading to the retroperitoneal space through the inguinal canal with node enlargement. Patient underwent orchiectomy with excision of infiltrated scrotum skin. Histologic diagnosis confirmed a typical form seminoma. The patient was then treated with a cisplatin-based chemotherapy, with a partial response. The patient recently relapsed and he is being treated with a new line of chemotherapy and subsequent surgery with or without radiotherapy. CONCLUSIONS: We described a rare presentation of testicular cancer. This case highlights the importance of a multidisciplinary approach to rare testis tumour presentation and early diagnosis for testicular cancers.


Assuntos
Canal Inguinal/patologia , Neoplasias Retroperitoneais/patologia , Seminoma/patologia , Neoplasias Testiculares/patologia , Adulto , Humanos , Masculino , Invasividade Neoplásica , Neoplasias Retroperitoneais/complicações , Neoplasias Retroperitoneais/terapia , Seminoma/complicações , Seminoma/terapia , Neoplasias Testiculares/complicações , Neoplasias Testiculares/terapia , Úlcera/complicações
7.
Sci Rep ; 11(1): 5379, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33686147

RESUMO

Neoadjuvant chemo-radiotherapy (CRT) followed by total mesorectal excision (TME) represents the standard treatment for patients with locally advanced (≥ T3 or N+) rectal cancer (LARC). Approximately 15% of patients with LARC shows a complete response after CRT. The use of pre-treatment MRI as predictive biomarker could help to increase the chance of organ preservation by tailoring the neoadjuvant treatment. We present a novel machine learning model combining pre-treatment MRI-based clinical and radiomic features for the early prediction of treatment response in LARC patients. MRI scans (3.0 T, T2-weighted) of 72 patients with LARC were included. Two readers independently segmented each tumor. Radiomic features were extracted from both the "tumor core" (TC) and the "tumor border" (TB). Partial least square (PLS) regression was used as the multivariate, machine learning, algorithm of choice and leave-one-out nested cross-validation was used to optimize hyperparameters of the PLS. The MRI-Based "clinical-radiomic" machine learning model properly predicted the treatment response (AUC = 0.793, p = 5.6 × 10-5). Importantly, the prediction improved when combining MRI-based clinical features and radiomic features, the latter extracted from both TC and TB. Prospective validation studies in randomized clinical trials are warranted to better define the role of radiomics in the development of rectal cancer precision medicine.


Assuntos
Aprendizado de Máquina , Imageamento por Ressonância Magnética , Modelos Biológicos , Terapia Neoadjuvante , Neoplasias Retais , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia
8.
Can Assoc Radiol J ; 72(4): 714-727, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32436394

RESUMO

The Liver Imaging Reporting and Data System (LI-RADS) is a recently developed classification aiming to improve the standardization of liver imaging assessment in patients at risk of developing hepatocellular carcinoma (HCC). The LI-RADS v2017 implemented new algorithms for ultrasound (US) screening and surveillance, contrast-enhanced US diagnosis and computed tomography/magnetic resonance imaging treatment response assessment. A minor update of LI-RADS was released in 2018 to comply with the American Association for the Study of the Liver Diseases guidance recommendations. The scope of this review is to provide a practical overview of LI-RADS v2018 focused both on the multimodality HCC diagnosis and treatment response assessment.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Diagnóstico por Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Imagem Multimodal/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Sistemas de Informação em Radiologia/estatística & dados numéricos , Resultado do Tratamento
9.
Eur Radiol ; 31(6): 3874-3883, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33211143

RESUMO

OBJECTIVES: (1) To investigate whether a contrast-free biparametric MRI (bp-MRI) including T2-weighted images (T2W) and diffusion-weighted images (DWI) can be considered an accurate alternative to the standard multiparametric MRI (mp-MRI), consisting of T2, DWI, and dynamic contrast-enhanced (DCE) imaging for the muscle-invasiveness assessment of bladder cancer (BC), and (2) to evaluate how the diagnostic performance of differently experienced readers is affected according to the type of MRI protocol. METHODS: Thirty-eight patients who underwent a clinically indicated bladder mp-MRI on a 3-T scanner were prospectively enrolled. Trans-urethral resection of bladder was the gold standard. Two sets of images, set 1 (bp-MRI) and set 2 (mp-MRI), were independently reviewed by four readers. Descriptive statistics, including sensitivity and specificity, were calculated for each reader. Receiver operating characteristic (ROC) analysis was performed, and the areas under the curve (AUCs) were calculated for the bp-MRI and the standard mp-MRI. Pairwise comparison of the ROC curves was performed. RESULTS: The AUCs for bp- and mp-MRI were respectively 0.91-0.92 (reader 1), 0.90 (reader 2), 0.95-0.90 (reader 3), and 0.90-0.87 (reader 4). Sensitivity was 100% for both protocols and specificity ranged between 79.31 and 89.66% and between 79.31 and 83.33% for bp-MRI and mp-MRI, respectively. No significant differences were shown between the two MRI protocols (p > 0.05). No significant differences were shown accordingly to the reader's experience (p > 0.05). CONCLUSIONS: A bp-MRI protocol consisting of T2W and DWI has comparable diagnostic accuracy to the standard mp-MRI protocol for the detection of muscle-invasive bladder cancer. The experience of the reader does not significantly affect the diagnostic performance using VI-RADS. KEY POINTS: • The contrast-free MRI protocol shows a comparable accuracy to the standard multiparametric MRI protocol in the bladder cancer muscle-invasiveness assessment. • VI-RADS classification helps non-expert radiologists to assess the muscle-invasiveness of bladder cancer. • DCE should be carefully interpreted by less experienced readers due to inflammatory changes representing a potential pitfall.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Neoplasias da Bexiga Urinária , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Masculino , Músculos , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade , Neoplasias da Bexiga Urinária/diagnóstico por imagem
10.
J Ultrasound ; 23(4): 481-485, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32886344

RESUMO

Vascular anomalies are classified as vascular tumors (VT) and vascular malformations (VM). VTs are divided according to their clinical behavior, while VMs are classified according to their flow characteristics, histopathologic features, and associations with other anomalies. Sonography emerges as the diagnostic imaging method of first choice for assessing abdominal wall disorders and masses, thus representing a valuable tool for the diagnosis and follow-up of abdominal wall VMs. In this review, we report a case of abdominal wall arteriovenous malformation (AVM) in a 17-year old and briefly discuss the cases of abdominal wall VMs.


Assuntos
Parede Abdominal/irrigação sanguínea , Parede Abdominal/diagnóstico por imagem , Malformações Arteriovenosas/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Adolescente , Malformações Arteriovenosas/terapia , Meios de Contraste , Embolização Terapêutica , Feminino , Humanos , Angiografia por Ressonância Magnética , Tomografia Computadorizada por Raios X/métodos
11.
In Vivo ; 34(4): 1981-1986, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32606170

RESUMO

AIM: To delineate cervical cancer gross tumor volume (GTV) on T2-magnetic resonance imaging (MRI) and apparent diffusion coefficient (ADC) maps, assessing volumes and inter-observer agreement between two observers. PATIENTS AND METHODS: A radiologist and a radiation oncologist delineated GTV on T2 (T2GTV) and ADC (ADCGTV) sequences. Dice similarity index (DICE) and Bland-Altman analysis were used to estimated concordance. RESULTS: Mean T2GTV and ADCGTV volumes were 43.84±71.47 cc and 37.28±68.92 cc according to the radiologist, and 43.4±70.44 cc and 36.65±69.21 cc according to the radiation oncologist. ADC led to statistically significantly smaller volumes compared to T2. The mean DICE index was 0.86 for T2GTV and 0.84 for ADCGTV The Bland-Altman plots globally showed concordance. CONCLUSION: GTV delineation was smaller in the ADC maps compared to T2-MRI, reaching an almost perfect agreement between observers. Thanks to this acceptable variability, adding functional imaging might provide more information for tumor delineation, improving reproducibility for image-guided adaptive radiotherapy.


Assuntos
Neoplasias do Colo do Útero , Feminino , Humanos , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Carga Tumoral , Neoplasias do Colo do Útero/diagnóstico por imagem
12.
Clin Genitourin Cancer ; 18(5): 409-415.e1, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32273236

RESUMO

BACKGROUND: The Vesical Imaging Reporting and Data System (VI-RADS) was recently introduced as a standardized approach to reporting multiparametric magnetic resonance imaging (mpMRI) for bladder cancer. We aimed to prospectively analyze its routine use and its diagnostic performance in discriminating non-muscle-invasive bladder cancer (NMIBC) and muscle-invasive bladder cancer (MIBC). PATIENTS AND METHODS: A total of 38 patients with diagnosis of suspect bladder cancer at cystoscopy underwent bladder mpMRI before transurethral resection of the bladder (TURB). Bladder tumors were categorized according to the VI-RADS. After TURB, the VI-RADS score was compared with histological report for each lesion separately. Receiving operating characteristic and decision curve analyses were used to assess its accuracy and clinical utility. RESULTS: A total of 68 lesions were included, of which 7 (10.3%) were MIBC. The pooled accuracy was 90.0% (95% confidence interval [CI], 75.4%-98.7%). The best threshold was estimated as VI-RADS 4, showing a sensitivity of 85.7% (95% CI, 57.1%-100%) and a specificity of 86.9% (95% CI, 78.7%-95.1%). Decision curve analyses showed that using VI-RADS ≥4 improved the net benefit compared with any default strategy for threshold probabilities of MIBC up to ∼40%, which is a reasonable clinical threshold for planning further treatments. CONCLUSIONS: Our prospective study shows that the use of VI-RADS as a standardized reporting method is appealing and could be considered in clinical practice owing to its high accuracy.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Neoplasias da Bexiga Urinária , Cistoscopia , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/cirurgia
13.
Curr Probl Diagn Radiol ; 49(6): 392-397, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31248709

RESUMO

PURPOSE: To assess the added value of diffusion weighted imaging (DWI) with intermediate (500 s/mm2) and high (1000 s/mm2) b values when combined to conventional contrast-enhanced magnetic resonance imaging (MRI) in identifying peritoneal neoplastic involvement. METHODS: Twenty-four patients with peritoneal carcinomatosis from gastrointestinal or gynecological tumors were retrospectively evaluated. All patients underwent peritonectomy with hyperthermic intraoperative chemotherapy and 1.5 T MRI including DWI with 500 s/mm2 and 1000 s/mm2 b values within 1 month from surgery. Images were independently reviewed by 2 radiologists with different experience in abdominal MRI in 3 separate reading sessions, the first including conventional MR images alone (T2-weighted, T1-weighted pre- and post gadolinium injection), the second conventional MRI and DWI with a b value of 500 s/mm2 (b 500-DWI), and the third conventional MRI and DWI with a b value of 1000 s/mm2 (b 1000-DWI). Apparent diffusion coefficient maps were included in the DWI analyses. Peritoneal dissemination was assessed in 9 anatomical sites, including right and left subphrenic space, paracolic gutters, small bowel mesentery, greater omentum, gastric-bowel serosa, free peritoneal surfaces, rectosigmoid-colon mesentery, and pelvis. The presence or absence of peritoneal dissemination for each patient and for each site was scored using a 5-point confidence scale. Sensitivity, specificity, and area under the curve (AUC) for identifying per-site peritoneal implants were calculated for each reader at each reading session. Interobserver agreement was evaluated using kappa statistics. RESULTS: For both readers, the sensitivity and AUC values resulting from combined interpretation of conventional MRI and DWI (both b500-DWI and b1000-DWI) were significantly higher than those of conventional MRI alone (P < 0.001). The added value of DWI was greater for the less experienced reader (sensitivity 0.55, specificity 0.73, AUC 0.64 on conventional MRI; sensitivity 0.75, specificity 0.72, AUC 0.74 on b500-DWI; sensitivity 0.87, specificity 0.72, AUC 0.80 on b1000-DWI) than for the more experienced reader (sensitivity 0.63, specificity 0.75, AUC 0.70 on conventional MRI; sensitivity 0.76, specificity 0.77, AUC 0.77 on b500-DWI; sensitivity 0.85, specificity 0.72, AUC 0.79 on b1000-DWI), although the differences between the 2 observers were not statistically significant. Interobserver agreement resulted to be fair (κ = 0.30) when dealing with conventional MRI alone. The addition of b500-DWI and b1000-DWI to conventional MRI allowed to reach a substantial agreement (κ = 0.75). CONCLUSIONS: The combined interpretation of high b value DWI and conventional MRI provides increased sensitivity and diagnostic performance in detection of peritoneal carcinomatosis in oncologic patients.


Assuntos
Carcinoma/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Peritoneais/diagnóstico por imagem , Idoso , Carcinoma/terapia , Terapia Combinada , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neoplasias Peritoneais/terapia , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Abdom Radiol (NY) ; 44(11): 3595-3605, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31444557

RESUMO

PURPOSE: To compare tumor detectability and conspicuity of standard b = 1000 s/mm2 (b1000) versus ultrahigh b = 2000 s/mm2 (b2000) diffusion-weighted imaging (DWI) in rectal cancer. METHODS: Fifty-five patients for a total of 81 3T DWI-MR scans were retrospectively evaluated by two differently experienced readers. A comparison between b1000 and b2000 for tumor detectability and conspicuity was performed. The conspicuity was qualitatively and quantitatively assessed by using three-point scale and whole tumor volume manual delineation, respectively. Receiver-operating characteristic curve (ROC) with area under the curve (AUC) analysis provided diagnostic accuracy in tumor detectability of restaging MR scans. Qualitative scores and quantitative features including mean signal intensity, variance, 10th percentile and 90th percentile, were compared using the Wilcoxon test. Interobserver agreement (IOA) for qualitative and quantitative data was calculated using Cohen's Kappa and intraclass correlation coefficient (ICC) respectively. RESULTS: Diagnostic accuracy was comparable between b1000 and b2000 for both readers (p > 0.05). Overall quality scores were significantly better for b2000 than b1000 (2.29 vs 1.65 Reader 1, p = 0.01; 2.18 vs 1.69 Reader 2, p = 0.04). IOA was equally good for both b values (k = 0.86 b1000, k = 0.86 b2000). Quantitative analysis revealed more uniform signal (measured in variance) of b2000 in both healthy surrounding tissue (p < 0.05) and tumor (p < 0.05), with less outliers (measured using 10th and 90th percentile). Additionally, b2000 offered lower mean signal intensity in tissue sorrounding the tumor (p < 0.05). Finally, ICC improved from 0.92 (b1000) to 0.97 (b2000). CONCLUSION: Ultrahigh b value (b2000) may improve rectal cancer conspicuity and introbserver agreement maintaining comparable diagnostic accuracy to standard b1000.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Retais/diagnóstico por imagem , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Retais/patologia , Estudos Retrospectivos , Sensibilidade e Especificidade
15.
Acta Oncol ; 58(4): 439-447, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30632876

RESUMO

BACKGROUND: Due to the high soft tissue resolution, magnetic resonance imaging (MRI) could improve the accuracy of pancreatic tumor delineation in radiation treatment planning. A multi-institutional study was proposed to evaluate the impact of MRI on inter-observer agreement in gross tumor volume (GTV) and duodenum delineation for pancreatic cancer compared with computer tomography (CT). MATERIAL AND METHODS: Two clinical cases of borderline resectable (Case 1) and unresectable (Case 2) pancreatic cancer were selected. In two sequential steps, diagnostic contrast-enhanced CT scan and MRI sequences were sent to the participating centers. CT-GTVs were contoured while blinded to MRI data sets. DICE index was used to evaluate the spatial overlap accuracy. RESULTS: Thirty-one radiation oncologists from different Institutions submitted the delineated volumes. CT- and MRI-GTV mean volumes were 21.6 ± 9.0 cm3 and 17.2 ± 6.0 cm3, respectively for Case 1, and 31.3 ± 15.6 cm3 and 33.2 ± 20.2 cm3, respectively for Case 2. Resulting MRI-GTV mean volume was significantly smaller than CT-GTV in the borderline resectable case (p < .05). A substantial agreement was shown by the median DICE index for CT- and MRI-GTV resulting as 0.74 (IQR: 0.67-0.75) and 0.61 (IQR: 0.57-0.67) for Case 1; a moderate agreement was instead reported for Case 2: 0.59 (IQR:0.52-0.66) and 0.53 (IQR:0.42-0.62) for CT- and MRI-GTV, respectively. CONCLUSION: Diagnostic MRI resulted in smaller GTV in borderline resectable case with a substantial agreement between observers, and was comparable to CT scan in interobserver variability, in both cases. The greater variability in the unresectable case underlines the critical issues related to the outlining when vascular structures are more involved. The integration of MRI with contrast-enhancement CT, thanks to its high definition of tumor relationship with neighboring vessels, could offer a greater accuracy of target delineation.


Assuntos
Neoplasias Gastrointestinais/diagnóstico por imagem , Neoplasias Gastrointestinais/patologia , Imageamento por Ressonância Magnética/métodos , Variações Dependentes do Observador , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Carga Tumoral
16.
Eur J Radiol Open ; 6: 56-59, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30671499

RESUMO

Hepatic steatosis is a frequent benign liver condition that can be idiopathic or secondary. The degree of fatty liver infiltration can be focal, diffuse or patchy. In this study, we present two patients with hepatic steatosis and multiple nodular liver lesions, due to fatty infiltration and fatty sparing respectively, mimicking a primary tumor or metastases ("pseudotumors"). Since the differential diagnosis of this kind of lesions can be difficult based on imaging alone, the knowledge of Contrast-Enhanced Ultrasound (CEUS) and Magnetic Resonance Imaging (MRI) findings may help radiologists to avoid an incorrect diagnosis of liver tumor, and unnecessary biopsies.

17.
J Appl Clin Med Phys ; 20(1): 321-330, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30586479

RESUMO

OBJECTIVE: To assess the radiation dose and image quality of ultra-low dose (ULD)-CT colonography (CTC) obtained with the combined use of automatic tube current (mAs) modulation with a quality reference mAs of 25 and sinogram-affirmed iterative reconstruction (SAFIRE), compared to low-dose (LD) CTC acquired with a quality reference mAs of 55 and reconstructed with filtered back projection (FBP). METHODS: Eighty-two patients underwent ULD-CTC acquisition in prone position and LD-CTC acquisition in supine position. Both ULD-CTC and LD-CTC protocols were compared in terms of radiation dose [weighted volume computed tomography dose index (CTDIvol ) and effective dose], image noise, image quality, and polyp detection. RESULTS: The mean effective dose of ULD-CTC was significantly lower than that of LD-CTC (0.98 and 2.69 mSv respectively, P < 0.0001) with an overall dose reduction of 63.2%. Image noise was comparable between ULD-CTC and LD-CTC (28.6 and 29.8 respectively, P = 0.09). There was no relevant difference when comparing image quality scores and polyp detection for both 2D and 3D images. CONCLUSION: ULD-CTC allows to significantly reduce the radiation dose without meaningful image quality degradation compared to LD-CTC.


Assuntos
Algoritmos , Doenças do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doenças do Colo/patologia , Doenças do Colo/radioterapia , Humanos , Posicionamento do Paciente , Decúbito Ventral , Dosagem Radioterapêutica , Estudos Retrospectivos
18.
Insights Imaging ; 9(4): 405-412, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29675627

RESUMO

Magnetic resonance imaging (MRI) allows to non-invasively evaluate rectal cancer staging and to assess the presence of "prognostic signs" such as the distance from the anorectal junction, the mesorectal fascia infiltration and the extramural vascular invasion. Moreover, MRI plays a crucial role in the assessment of treatment response after chemo-radiation therapy, especially considering the growing interest in the new conservative policy (wait and see, minimally invasive surgery). We present a practical overview regarding the state of the art of the MRI protocol, the main signs that radiologists should consider for their reports during their clinical activity and future perspectives. TEACHING POINTS: • MRI protocol for rectal cancer staging and re-staging. • MRI findings that radiologists should consider for reports during everyday clinical activity. • Perspectives regarding the development of latest technologies.

19.
Eur J Radiol ; 101: 17-23, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29571792

RESUMO

BACKGROUND: MRI plays a crucial role to identify men with a high likelihood of clinically significant prostate cancer who require immediate biopsy. The added value of DCE MRI in combination with T2-weighted imaging and DWI is controversial (risks related to gadolinium administration, duration of MR exam, financial burden, effects on diagnostic performance). A comparison of a biparametric and a standard multiparametric MR imaging protocol, taking into account the different experience of the readers, may help to choose the best MR approach regarding diagnostic performance. PURPOSE: To determine the added value of dynamic contrasted-enhanced imaging (DCE) over T2-weighted imaging (T2-WI) and diffusion weighted imaging (DWI) for the detection of clinically significant prostate cancer, and to evaluate how it affects the diagnostic performance of three readers with different grade of experience in prostate imaging. MATERIALS AND METHODS: Eighty-five patients underwent prostate MR examination at 1.5 T MR scanner performed because of elevated prostate-specific antigen level and/or suspicion of prostate cancer at digital rectal examination. Two MR images sets (Set 1 = biparametric, Set 2 = multiparametric) were retrospectively and independently scored by three radiologists with 7, 3 and 1 years of experience in prostate MR imaging respectively, according to PI-RADS v2. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated by dichotomizing reader scores. Receiver operating characteristic (ROC) analysis was performed and areas under the curve (AUCs) were calculated for each reader and image set. A comparison of ROC curves was performed to test the difference between the areas under the ROC curves among the three readers. RESULTS: There was no significant difference regarding the detection of clinically significant tumor among the three readers between the two image sets. The AUC for the bi-parametric and multi-parametric MR imaging protocol was respectively 0.68-0.72 (Reader 1), 0.72-0.70 (Reader 2) and 0.60-0.54 (Reader 3). ROC curve comparison revealed no statistically significant differences for each protocol among the most experienced (Reader 1) and the other readers (Readers 2-3). CONCLUSION: The diagnostic accuracy of a bi-parametric MR imaging protocol consisting of T2-weighted imaging and DWI is comparable with that of a standard multi-parametric imaging protocol for the detection of clinically significant prostate cancer. The experience of the reader does not significantly modify the diagnostic performance of both MR protocols.


Assuntos
Próstata/patologia , Neoplasias da Próstata/diagnóstico , Idoso , Biópsia/métodos , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Exame Retal Digital/métodos , Métodos Epidemiológicos , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem
20.
Oncol Lett ; 15(2): 1823-1828, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29434879

RESUMO

Increased knowledge regarding the heterogeneity of Prostate Cancer (PC) and its variable outcomes has generated controversy over the best clinical approach. Nowadays, it is well-known that patient outcomes and clinical management may be improved by an efficient organization of the national health care system. The Interdisciplinary Group for Oncological Care (GICO) for PC patients was created by our healthcare management company in September 2010. Since then, a multidisciplinary internal report was applied to PC patients. This report highlights our methodology and experience of planning a GICO, and illustrates the results obtained for the management of PC patients before and after the adopted GICO criteria in a single institution, the SS Annunziata Hospital (Chieti, Italy).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA