Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ultrasound Obstet Gynecol ; 63(4): 529-535, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38051135

RESUMO

OBJECTIVE: To assess whether the cannula insertion site on the maternal abdomen during fetal endoscopic tracheal occlusion (FETO) for congenital diaphragmatic hernia (CDH) was associated with preterm prelabor rupture of membranes (PPROM) before balloon removal. METHODS: This was a multicenter retrospective study of consecutive pregnancies with isolated left- or right-sided CDH that underwent FETO in four centers between January 2009 and January 2021. The site for balloon insertion was categorized as above or below the umbilicus. One propensity score was analyzed in both groups to calculate an average treatment effect (ATE) by inverse probability of treatment weighting. Logistic regression and Cox proportional hazard regression including the ATE weights were performed to examine the effect size of entry point on the frequency and timing of PPROM before balloon removal. RESULTS: A total of 294 patients were included. The mean ± SD gestational age at PPROM was 33.45 ± 2.01 weeks and the mean rate of PPROM before balloon removal was 25.9% (76/294). Gestational age at FETO was later in the below-umbilicus group (mean ± SD, 29.47 ± 1.29 weeks vs 29.00 ± 1.25 weeks; P = 0.002) and the duration of FETO was longer in the above-umbilicus group (median, 14.49 min (interquartile range (IQR), 8.00-21.00 min) vs 11.00 min (IQR, 7.00-14.49 min); P = 0.002). After balancing for possible confounding factors, trocar entry point below the umbilicus did not increase the risk of PPROM before balloon removal (adjusted odds ratio, 1.56 (95% CI, 0.89-2.74); P = 0.120) and had no effect on the timing of PPROM before balloon removal (adjusted hazard ratio, 1.56 (95% CI, 0.95-2.55); P = 0.080). CONCLUSION: There was no evidence that uterine entry site for FETO was correlated with the risk of PPROM before balloon removal. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Oclusão com Balão , Ruptura Prematura de Membranas Fetais , Hérnias Diafragmáticas Congênitas , Gravidez , Recém-Nascido , Feminino , Humanos , Lactente , Hérnias Diafragmáticas Congênitas/cirurgia , Fetoscopia , Cânula , Estudos Retrospectivos , Traqueia/cirurgia
2.
Ultrasound Obstet Gynecol ; 58(6): 804-812, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34468062

RESUMO

Gastroschisis (GS) is a congenital abdominal wall defect, in which the bowel eviscerates from the abdominal cavity. It is a non-lethal isolated anomaly and its pathogenesis is hypothesized to occur as a result of two hits: primary rupture of the 'physiological' umbilical hernia (congenital anomaly) followed by progressive damage of the eviscerated bowel (secondary injury). The second hit is thought to be caused by a combination of mesenteric ischemia from constriction in the abdominal wall defect and prolonged amniotic fluid exposure with resultant inflammatory damage, which eventually leads to bowel dysfunction and complications. GS can be classified as either simple or complex, with the latter being complicated by a combination of intestinal atresia, stenosis, perforation, volvulus and/or necrosis. Complex GS requires multiple neonatal surgeries and is associated with significantly greater postnatal morbidity and mortality than is simple GS. The intrauterine reduction of the eviscerated bowel before irreversible damage occurs and subsequent defect closure may diminish or potentially prevent the bowel damage and other fetal and neonatal complications associated with this condition. Serial prenatal amnioexchange has been studied in cases with GS as a potential intervention but never adopted because of its unproven benefit in terms of survival and bowel and lung function. We believe that recent advances in prenatal diagnosis and fetoscopic surgery justify reconsideration of the antenatal management of complex GS under the rubric of the criteria for fetal surgery established by the International Fetal Medicine and Surgery Society (IFMSS). Herein, we discuss how conditions for fetoscopic repair of complex GS might be favorable according to the IFMSS criteria, including an established natural history, an accurate prenatal diagnosis, absence of fully effective perinatal treatment due to prolonged need for neonatal intensive care, experimental evidence for fetoscopic repair and maternal and fetal safety of fetoscopy in expert fetal centers. Finally, we propose a research agenda that will help overcome barriers to progress and provide a pathway toward clinical implementation. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Parede Abdominal/cirurgia , Fetoscopia/tendências , Feto/cirurgia , Gastrosquise/cirurgia , Intestinos/cirurgia , Parede Abdominal/embriologia , Feminino , Fetoscopia/métodos , Feto/anormalidades , Feto/embriologia , Gastrosquise/embriologia , Humanos , Intestinos/embriologia , Seleção de Pacientes , Gravidez
3.
Ultrasound Obstet Gynecol ; 57(3): 378-385, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32924187

RESUMO

OBJECTIVE: To evaluate the neonatal outcome of fetuses with isolated right-sided congenital diaphragmatic hernia (iRCDH) based on prenatal severity indicators and antenatal management. METHODS: This was a retrospective review of prospectively collected data on consecutive cases diagnosed with iRCDH before 30 weeks' gestation in four fetal therapy centers, between January 2008 and December 2018. Data on prenatal severity assessment, antenatal management and perinatal outcome were retrieved. Univariate and multivariate logistic regression analysis were used to identify predictors of survival at discharge and early neonatal morbidity. RESULTS: Of 265 patients assessed during the study period, we excluded 40 (15%) who underwent termination of pregnancy, two cases of unexplained fetal death, two that were lost to follow-up, one for which antenatal assessment of lung hypoplasia was not available and six cases which were found to have major associated anomalies or syndromes after birth. Of the 214 fetuses with iRCDH included in the neonatal outcome analysis, 86 were managed expectantly during pregnancy and 128 underwent fetal endoscopic tracheal occlusion (FETO) with a balloon. In the expectant-management group, lung size measured by ultrasound or by magnetic resonance imaging was the only independent predictor of survival (observed-to-expected lung-to-head ratio (o/e-LHR) odds ratio (OR), 1.06 (95% CI, 1.02-1.11); P = 0.003). Until now, stratification for severe lung hypoplasia has been based on an o/e-LHR cut-off of 45%. In cases managed expectantly, the survival rate was 15% (4/27) in those with o/e-LHR ≤ 45% and 61% (36/59) for o/e-LHR > 45% (P = 0.001). However, the best o/e-LHR cut-off for the prediction of survival at discharge was 50%, with a sensitivity of 78% and specificity of 72%. In the expectantly managed group, survivors with severe pulmonary hypoplasia stayed longer in the neonatal intensive care unit than did those with mildly hypoplastic lungs. In fetuses with an o/e-LHR ≤ 45% treated with FETO, survival rate was higher than in those with similar lung size managed expectantly (49/120 (41%) vs 4/27 (15%); P = 0.014), despite higher prematurity rates (gestational age at birth: 34.4 ± 2.7 weeks vs 36.8 ± 3.0 weeks; P < 0.0001). In fetuses treated with FETO, gestational age at birth was the only predictor of survival (OR, 1.25 (95% CI, 1.04-1.50); P = 0.02). CONCLUSIONS: Antenatal measurement of lung size can predict survival in iRCDH. In fetuses with severe lung hypoplasia, FETO was associated with a significant increase in survival without an associated increase in neonatal morbidity. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Oclusão com Balão/estatística & dados numéricos , Fetoscopia/estatística & dados numéricos , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Hérnias Diafragmáticas Congênitas/embriologia , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adulto , Oclusão com Balão/métodos , Feminino , Fetoscopia/métodos , Idade Gestacional , Hérnias Diafragmáticas Congênitas/cirurgia , Humanos , Recém-Nascido , Modelos Logísticos , Pulmão/diagnóstico por imagem , Pulmão/embriologia , Imageamento por Ressonância Magnética/estatística & dados numéricos , Valor Preditivo dos Testes , Gravidez , Resultado da Gravidez/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos , Taxa de Sobrevida , Traqueia/embriologia , Traqueia/cirurgia , Resultado do Tratamento , Conduta Expectante/estatística & dados numéricos
4.
Ultrasound Obstet Gynecol ; 57(1): 105-112, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33012007

RESUMO

OBJECTIVE: To investigate the efficacy and safety of the 'smart' tracheal occlusion (Smart-TO) device in fetal lambs with diaphragmatic hernia (DH). METHODS: DH was created in fetal lambs on gestational day 70 (term, 145 days). Fetuses were allocated to either pregnancy continuation until term (DH group) or fetoscopic endoluminal tracheal occlusion (TO), performed using the Smart-TO balloon on gestational day 97 (DH + TO group). On gestational day 116, the presence of the balloon was confirmed on ultrasound, then the ewe was walked around a 3.0-Tesla magnetic resonance scanner for balloon deflation, which was confirmed by ultrasound immediately afterwards. At term, euthanasia was performed and the fetus retrieved. Efficacy of occlusion was assessed by the lung-to-body-weight ratio (LBWR) and lung morphometry. Safety parameters included tracheal side effects assessed by morphometry and balloon location after deflation. The unoccluded DH lambs served as a comparator. RESULTS: Six fetuses were included in the DH group and seven in the DH + TO group. All balloons deflated successfully and were expelled spontaneously from the airways. In the DH + TO group, in comparison to controls, the LBWR at birth was significantly higher (1.90 (interquartile range (IQR), 1.43-2.55) vs 1.07 (IQR, 0.93-1.46); P = 0.005), while on lung morphometry, the alveolar size was significantly increased (mean linear intercept, 47.5 (IQR, 45.6-48.1) vs 41.9 (IQR, 38.8-46.1) µm; P = 0.03); whereas airway complexity was lower (mean terminal bronchiolar density, 1.56 (IQR, 1.0-1.81) vs 2.23 (IQR, 2.14-2.40) br/mm2 ; P = 0.005). Tracheal changes on histology were minimal in both groups, but more noticeable in fetal lambs that underwent TO than in unoccluded lambs (tracheal score, 2 (IQR, 1-3) vs 0 (0-1); P = 0.03). CONCLUSIONS: In fetal lambs with DH, TO using the Smart-TO balloon is effective and safe. Occlusion can be reversed non-invasively and the deflated intact balloon expelled spontaneously from the fetal upper airways. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Oclusão com Balão/métodos , Hérnias Diafragmáticas Congênitas/terapia , Animais , Feminino , Fetoscopia , Humanos , Gravidez , Ovinos , Traqueia/diagnóstico por imagem , Traqueia/patologia
5.
Ultrasound Obstet Gynecol ; 56(4): 522-531, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32602968

RESUMO

OBJECTIVE: One of the drawbacks of fetal endoscopic tracheal occlusion (FETO) for congenital diaphragmatic hernia is the need for a second invasive intervention to re-establish airway patency. The 'Smart-TO' device is a new balloon for FETO that deflates spontaneously when placed in a strong magnetic field, therefore overcoming the need for a second procedure. The safety and efficacy of this device have not yet been demonstrated. The aim of this study was to investigate the reversibility, local side effects and occlusiveness of the Smart-TO balloon, both in a simulated in-utero environment and in the fetal lamb model. METHODS: First, the reversibility of tracheal occlusion by the Smart-TO balloon was tested in a high-fidelity simulator. Following videoscopic tracheoscopic balloon insertion, the fetal mannequin was placed within a 1-L water-filled balloon to mimic the amniotic cavity. This was held by an operator in front of their abdomen, and different fetal and maternal positions were simulated to mimic the most common clinical scenarios. Following exposure to the magnetic field generated by a 1.5-T magnetic resonance (MR) machine, deflation of the Smart-TO balloon was assessed by tracheoscopy. In cases of failed deflation, the mannequin was reinserted into a water-filled balloon for additional MR exposure, up to a maximum of three times. Secondly, reversibility, occlusiveness and local effects of the Smart-TO balloon were tested in vivo in fetal lambs. Tracheal occlusion was performed in fetal lambs on gestational day 95 (term, 145 days), either using the balloon currently used in clinical practice (Goldbal2) (n = 5) or the Smart-TO balloon (n = 5). On gestational day 116, the presence of the balloon was assessed by tracheoscopy. Deflation was performed by puncture (Goldbal2) or MR exposure (Smart-TO). Six unoccluded fetal lambs served as controls. Following euthanasia, the lung-to-body-weight ratio (LBWR), lung morphometry and tracheal circumference were assessed. Local tracheal changes were measured using a hierarchical histologic scoring system. RESULTS: Ex vivo, Smart-TO balloon deflation occurred after a single MR exposure in 100% of cases in a maternal standing position with the mannequin at a height of 95 cm (n = 32), 55 cm (n = 8) or 125 cm (n = 8), as well as when the maternal position was 'lying on a stretcher' (n = 8). Three out of eight (37.5%) balloons failed to deflate at first exposure when the maternal position was 'sitting in a wheelchair'. Of these, two balloons deflated after a second MR exposure, but one balloon remained inflated after a third exposure. In vivo, all Smart-TO balloons deflated successfully. The LBWR in fetal lambs with tracheal occlusion by a Smart-TO balloon was significantly higher than that in unoccluded controls, and was comparable with that in the Goldbal2 group. There were no differences in lung morphometry and tracheal circumference between the two balloon types. Tracheal histology showed minimal changes for both balloons. CONCLUSIONS: In a simulated in-utero environment, the Smart-TO balloon was effectively deflated by exposure of the fetus in different positions to the magnetic field of a 1.5-T MR system. There was only one failure, which occurred when the mother was sitting in a wheelchair. In healthy fetal lambs, the Smart-TO balloon is as occlusive as the clinical standard Goldbal2 system and has only limited local side effects. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Manuseio das Vias Aéreas/métodos , Oclusão com Balão , Fetoscopia/métodos , Espectroscopia de Ressonância Magnética/uso terapêutico , Reoperação/métodos , Animais , Modelos Animais de Doenças , Feminino , Hérnias Diafragmáticas Congênitas/embriologia , Hérnias Diafragmáticas Congênitas/cirurgia , Humanos , Gravidez , Ovinos , Treinamento por Simulação , Traqueia/embriologia , Traqueia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA