Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Thorac Imaging ; 34(5): 338-344, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30801452

RESUMO

OBJECTIVES: Left ventricular (LV) hypertrophy in resistant hypertensive patients is associated with a reduced intramyocardial perfusion. Renal sympathetic denervation (RDN) has been shown to reduce blood pressure (BP) and sympathetic tone. We aimed to prospectively investigate the effect of RDN on functional myocardial parameters and myocardial perfusion reserve (MPR) using cardiac magnetic resonance imaging (cMRI) in patients with resistant hypertension. METHODS: A total of 15 resistant hypertensive patients (11 male individuals, mean age 62±13 y) were included. Adenosine stress-induced cMRI was performed at baseline, 3, 6, and 12 months after RDN. RDN was performed using a single soft-tip radiofrequency catheter (Symplicity). cMRI semiquantitative perfusion analysis was performed using the upslope of myocardial signal enhancement to derive the myocardial perfusion reserve index. RESULTS: Both systolic-BP and diastolic-BP significantly decreased from 148±14 to 133±14 mm Hg and 87±14 to 80±10 mm Hg, respectively (P<0.05). LV septal wall thickness was significantly reduced (P<0.001). LV ejection fraction and MPR lacked significant trends 12 months after RDN. CONCLUSIONS: In this pilot study, RDN significantly reduced LV mass and LV septal wall thickness, as diagnosed by cMRI, with no significant changes in MPR. cMRI may help in diagnosing clinically relevant changes of functional myocardial parameters after interventional therapy in resistant hypertensive patients.


Assuntos
Coração/diagnóstico por imagem , Hipertensão/complicações , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/cirurgia , Imageamento por Ressonância Magnética/métodos , Simpatectomia/métodos , Feminino , Seguimentos , Coração/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/patologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Projetos Piloto , Estudos Prospectivos , Artéria Renal , Resultado do Tratamento
2.
JACC Cardiovasc Imaging ; 7(3): 267-77, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24529887

RESUMO

OBJECTIVES: The aim of this study was to determine the feasibility of computed tomography (CT)-based dynamic myocardial perfusion imaging for the assessment of myocardial ischemia and infarction compared with cardiac magnetic resonance (CMR). BACKGROUND: Sequential myocardial CT perfusion imaging has emerged as a novel imaging technique for the assessment of myocardial hypoperfusion. METHODS: We prospectively enrolled subjects with known coronary artery disease who underwent adenosine-mediated stress dynamic dual-source CT (100 kV, 320 mAs/rot) and CMR (3-T). Estimated myocardial blood flow (eMBF) and estimated myocardial blood volume (eMBV) were derived from CT images, using a model-based parametric deconvolution technique. The values were independently related to perfusion defects (ischemic and/or infarcted myocardial segments) as visually assessed during rest/stress and late gadolinium enhancement CMR. Conventional measures of diagnostic accuracy and differences in eMBF/eMBV were determined. RESULTS: Of 38 enrolled subjects, 31 (mean age 70.4 ± 9.3 years; 77% men) completed both CT and CMR protocols. The prevalence of ischemic and infarcted myocardial segments detected by CMR was moderate (11.6%, n = 56 and 12.6%, n = 61, respectively, of 484 analyzed segments, with 8.4% being transmural). The diagnostic accuracy of CT for the detection of any perfusion defect was good (eMBF threshold, 88 ml/mg/min; sensitivity, 77.8% [95% confidence interval (CI): 69% to 85%]; negative predictive value, 91.3% [95% CI: 86% to 94%]) with moderate positive predictive value (50.6% [95% CI: 43% to 58%] and specificity (75.41% [95% CI: 70% to 79%]). Higher diagnostic accuracy was observed for transmural perfusion defects (sensitivity 87.8%; 95% CI: 74% to 96%) and infarcted segments (sensitivity 85.3%; 95% CI: 74% to 93%). Although eMBF in high-quality examinations was lower but not different between ischemic and infarcted segments (72.3 ± 18.7 ml/100 ml/min vs. 73.1 ± 31.9 ml/100 ml/min, respectively, p > 0.05), eMBV was significantly lower in infarcted segments compared with ischemic segments (11.3 ± 3.3 ml/100 ml vs. 18.4 ± 2.8 ml/100 ml, respectively; p < 0.01). CONCLUSIONS: Compared with CMR, dynamic stress CT provides good diagnostic accuracy for the detection of myocardial perfusion defects and may differentiate ischemic and infarcted myocardium.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Infarto do Miocárdio/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Idoso , Doença da Artéria Coronariana/fisiopatologia , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional
3.
Invest Radiol ; 47(6): 332-8, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22543970

RESUMO

PURPOSE: The aim of this study was to investigate if a quantitative evaluation of a magnetic resonance (MR) perfusion examination of the myocardium can achieve a comparable diagnostic accuracy as a semiquantitative evaluation. METHODS: A total of 31 patients with suspected coronary artery disease underwent MR imaging and conventional coronary angiography. Stenoses with a diameter reduction between 50% and 75% were evaluated by an intracoronary pressure wire examination (fractional flow reserve) for assessment of their hemodynamic relevance. A 0.05 mmol/kg contrast material bolus (gadopentetate dimeglumine) was applied during adenosine-induced stress (140 µg/kg/min) and at rest with a flow rate of 5 mL/s. Signal intensity time curves of the first-pass MR perfusion images, acquired at rest and under adenosine stress with a Saturation Recovery-turbo Fast Low Angle Shot Magnetic Resonance Imaging sequence, were analyzed by Argus Dynamic Signal Analysis (Siemens Healthcare, Erlangen, Germany). For the semiquantitative evaluation, the upslope value of a linear fit from the foot point to the signal maximum was calculated for 18 segments (signal intensity units per second). For the quantitative evaluation, a model-independent deconvolution was used to calculate coronary blood flow (MBF in mL/100 g/min). For each segment for the stress and rest examination, upslope value and MBF were determined. In addition, the ratio of the stress and rest value for each segment was determined (myocardial perfusion reserve index [MPRI]). The mean value of the 2 segments with the lowest value was calculated for each patient. Coronary artery stenosis greater than 75% or greater than 50% with positive fractional flow reserve less than 0.75 was considered as hemodynamically relevant. Receiver-operator-curves were calculated. RESULTS: The values of the area under the ROC curves were 0.74, 0.66, and 0.92 for the US(Stress), US(Rest), and US(MPRI) evaluations (semiquantitative evaluation). The values for the MBF(Stress), MBF(Rest), and MBF(MPRI) evaluations (quantitative evaluation) were 0.92, 0.68, and 0.84, respectively. Comparing US(MPRI) and MBF(Stress), identical values and no significant difference were found for the area under the ROC curves. CONCLUSION: A quantitative evaluation using a model-free deconvolution provides identical diagnostic performance when only a stress examination is used, much similar to a semiquantitative evaluation, if both stress and rest examinations are used.


Assuntos
Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Eur Radiol ; 19(11): 2771-8, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19504106

RESUMO

The purpose of this study was to establish and evaluate contrast-enhanced MR-lymphangiography (MRL) at 3.0 T for detection and visualization of abnormalities of the peripheral lymphatic system. Sixteen patients were examined with a highly resolved isotropic T1w-3D-GRE-(FLASH) sequence (TR 3.76 ms/TE 1.45 ms/FA 30 degrees /voxel-size 0.8 x 0.8 x 0.8 mm(3)) at 3T after intracutaneous injection of gadolinium-diethylene-triamine-pentaacetic-acid. Two radiologists evaluated overall image quality, contrast between lymph vessels and background tissue, venous contamination, visualized levels, and fat-saturation-homogeneity on 3D maximum-intensity projections. Overall image quality was good to excellent, and all examinations were diagnostic except one, where contrast medium was injected subcutaneously instead of intracutaneously. Overall image quality was good to excellent in 12/16 cases, depiction of lymph vessels was good to excellent in 15/16 cases. Venous contamination was always present, but diagnostically problematical in only one case. Instant lymphatic drainage was observed in unaffected extremities, reaching the pelvic level after approximately 10 min. Lymphatic drainage was considerably delayed in lymphedematous extremities. Ectatic lymph vessels, entrapment, and diffuse drainage of contrast medium correlated with impaired lymphatic drainage. In conclusion, MRL at 3.0 T provides very high spatial resolution and anatomical detail of normal and abnormal peripheral lymph vessels. MRL may thus become a valuable tool for microsurgical treatment planning and monitoring.


Assuntos
Vasos Linfáticos/patologia , Linfedema/patologia , Linfocele/patologia , Linfografia/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Meios de Contraste/farmacologia , Estudos de Viabilidade , Feminino , Gadolínio DTPA/farmacologia , Humanos , Linfonodos/patologia , Linfedema/diagnóstico , Linfocele/diagnóstico , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA